Data sheet 3WL1350-4DG62-1AA2-Z A05+C22+K07

Fixed-mounted circuit breaker 3-pole, Size 3, IEC In=5000 A up to


690 V, 50/60 Hz AC Icu=100 kA at 500 V Rear horizontal connection
Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in
Ground fault/N protection integrated With manual operating
mechanism with storage with mechanical request without 1st
auxiliary release without 2nd auxiliary release 2NO+2NC A05=
Version for 1000 V C22= Ready indicator K07= Tripped signaling
contact, 1 CO not possible with option F02

Model
Product brand name SENTRON
Product designation ACB
Design of the product IEC 60947-2
Design of the operating mechanism Pushbutton
Type of the driving mechanism Manual operating mechanism with mechanical closing
Type of the driving mechanism / motor drive No

3WL1350-4DG62-1AA2-Z A05+C22+K07 Subject to change without notice


Page 1/7 07/23/2020 © Copyright Siemens
Design of the overcurrent release ETU27B

General technical data


Number of poles 3
Size of the circuit-breaker 3
Usage category B
circuit-breaker / Design 3WL1

Voltage
Rated insulation voltage Ui 1 000 V
Operating voltage
● at AC / at 50/60 Hz / rated value 1 000 V

Protection class
Protection class IP IP20
Protection class IP / on the front IP20
protection function of the overcurrent release LSING

Dissipation
Power loss [W] / for rated value of the current / at AC 210 W
/ in hot operating state / per pole

Current
Operating current / at 45 °C / rated value 5 000 A
Continuous current / rated value 5 000 A
Adjustable pick-up value current
● of instantaneous short-circuit trip unit / initial 50 000 A
value
● of instantaneous short-circuit trip unit / Full- 50 000 A
scale value

Main circuit
Operating frequency
● 1 / rated value 50 Hz
● 2 / rated value 60 Hz
Operating current
● at 40 °C / rated value 5 000 A
● at 50 °C / rated value 5 000 A
● at 55 °C / rated value 5 000 A
● at 60 °C / rated value 5 000 A
● at 65 °C / rated value 5 000 A
● at 70 °C / rated value 5 000 A

Auxiliary circuit
Number of NC contacts / for auxiliary contacts 2
Number of NO contacts / for auxiliary contacts 2

Suitability

3WL1350-4DG62-1AA2-Z A05+C22+K07 Subject to change without notice


Page 2/7 07/23/2020 © Copyright Siemens
Suitability for use Plant / motor protection

Product details
Product component
● Trip indicator Yes
● Voltage trigger No
● undervoltage release No
Product extension / optional / motor drive Yes

Product function
Product function
● Ground fault protection Yes
● Phase failure detection Yes

Display and operation


Display version without display

Short circuit
Operational short-circuit current breaking capacity
(Ics)
● at 415 V / rated value 100 kA
● at 500 V / rated value 100 kA
● at 690 V / rated value 85 kA
● at 1000 V / rated value 85 kA
Maximum short-circuit current breaking capacity (Icu)
● at 415 V / rated value 100 kA
● at 500 V / rated value 100 kA
● at 690 V / rated value 100 kA
● at 1000 V / rated value 85 kA

Connections
Arrangement of electrical connectors / for main Main connection rear side horizontal
current circuit
Type of electrical connection / for main current circuit busbar connection

Mechanical Design
Height 439 mm
Width 704 mm
Depth 337 mm
Mounting type fixed mounting

Environmental conditions
Ambient temperature / during operation
● minimum -40 °C
● maximum 70 °C
Ambient temperature / during storage
● minimum -40 °C

3WL1350-4DG62-1AA2-Z A05+C22+K07 Subject to change without notice


Page 3/7 07/23/2020 © Copyright Siemens
● maximum 80 °C

Certificates
Reference code
● acc. to DIN EN 61346-2 Q
● acc. to DIN EN 81346-2 Q

General Product Approval Declaration of Test Certificates Shipping Ap-


Conformity proval
Miscellaneous Special Test Certi-
ficate

Shipping Approval other


CCS / China Classi- Environmental Con-
fication Society firmations

other
Manufacturer De- Confirmation Miscellaneous
claration

Further information
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3WL1350-4DG62-1AA2-Z A05+C22+K07
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3WL1350-4DG62-1AA2-Z A05+C22+K07
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3WL1350-4DG62-1AA2-Z A05+C22+K07
CAx-Online-Generator
http://www.siemens.com/cax
Tender specifications
http://www.siemens.com/specifications

3WL1350-4DG62-1AA2-Z A05+C22+K07 Subject to change without notice


Page 4/7 07/23/2020 © Copyright Siemens
5.5

30
275

327.5
451
437

275

30
150
123.5

76
270 205 20 130 210 210

680 12 130 45

150 106

210 127

230

30

30

30 160

13
.5
35

11

12.5

139 248

704

3WL1350-4DG62-1AA2-Z A05+C22+K07 Subject to change without notice


Page 5/7 07/23/2020 © Copyright Siemens
L / L+
L1

L2

L3

-Q
X8.11

X6.2

X6.4
X6.6
X8.12

X7.12

X6.12
X7.14

X6.10

-A1 ETU27B

I> S

-S20

I >> I

N N

In = 5000A
Ir = 2000A-5000A
Isd = 6250A-60000A
Ii = 50000A
IN = In / OFF
Ig = 400A / 600A / 800A / 1000A / 1200A / OFF

-Q1

-S1 -S2

-T1

-T2

-T3

-F5 -S24
X8.10

X7.13

X6.11
X8.9

X6.5

X6.9

X6.1

X6.3
L1

L2

L3

N / L-

L (Long Time Delay / Überlastschutz); S (Short Time Delay / Kurzschlussschutz, kurzzeitverzögert); I (Instantaneous / Kurzschlussschutz, unverzögert);
N (Neutral Protection / Neutralleiterschutz); G (Ground Fault Protection / Erdschlussschutz); F5 (Maglatch for trip unit / Auslösemagnet);
S1 - S8 (Auxiliary switch / Hilfsschalter); S20 (Ready to close signalling switch / Einschaltbereitschaftsmeldeschalter);
S24 (1st trip signalling switch K07 (Reset position) / Erster Ausgelöstmeldeschalter K07 (Reset Position));

3WL1350-4DG62-1AA2-Z A05+C22+K07 Subject to change without notice


Page 6/7 07/23/2020 © Copyright Siemens
last modified: 06/09/2020

3WL1350-4DG62-1AA2-Z A05+C22+K07 Subject to change without notice


Page 7/7 07/23/2020 © Copyright Siemens