You are on page 1of 108

CALORIFIERS

& BUFFER TANKS

P R I C E L I S T 3
The Cordivari group has a proven industrial tradition and is now one of the most
important manufacturers in the heating and plumbing industry in Italy.
Founded in 1972 by Ercole Cordivari, the group is producing calorifiers & buffer
tanks, solar thermal systems, compressed air receivers, design radiators, chimney
flues and food containers. The Cordivari plants are situated on an area of 200.000
square meters and with turnover of more than 80 million euro.
Thanks to its development strategies all addressed to the new technologies and to
the training of new human resources, Cordivari is equipped with modern structures
and advanced production processes. Technological, ergonomic and ecological
choises allows to work respecting the human being and its environment. UNI
EN ISO 14001:2004 environment managing systems and UNI EN ISO 9001:2008
Quality system are perfectly integrated to grant and ensure companies main goal
and values.
The highly qualified management, the constant research for innovative solutions
and the extremely customer-oriented company policy stand for the leading market
position and the exclusive know-how in the field of integrated heating systems
that the Cordivari group has acquired.
All this is the result of a continuous commitment to achieving Customer
Satisfaction.

Cav. Ercole Cordivari


PLANNING

Cordivari has been the first Hvac Italian company having its quality Planning is the most important activity of Cordivari’s production
systems certified UNI EN ISO 9001: 2008 – Customer satisfaction-, processes. The main technical characteristics of each product is
now integrated with the new environment certification UNI EN ISO always defined in accordance with the market requirements.
14001:2004.

TECHNOLOGY

CERTIFICATIONS
Since ever Cordivari has been in line with the most important national and international company and product certifications. Cordivari products
comply with all European directives such as the P.E.D., in which respect all calorifiers and pressure vessels are manufactured.

2
QUALITY CONTROL ON 100% OF THE OUTPUT

Production cycles contemplate wonderful fusion between industrial automation and handicraft finishing. Each single product is manufactured
by state of the art technology production lines and checked carefully by our experienced technicians at the end of the production process.

ENVIRONMENT FRIENDLY PRODUCTION PHILOSOPHY

To produce in total harmony with the environment is the challenge that the Company has been targeting since its foundation. The use of
recyclable materials like stainless steel (that is not only long lasting and ecological but overall a guarantee of total hygiene) and only ecological
coating powders, is a guarantee and testimony of this philosophy.

PRODUCTS IN CONFORMITY TO EUP DIRECTIVE


ENERGY USING PRODUCTS - 2005/32/CE

3
GUIDE WHEN CHOOSING A CALORIFIER
DOMESTIC HOT WATER

A calorifier is an indirect water heating appliance (i.e. one that features Cordivari offers a wide and varied range of calorifiers and buffers,
at least one heat exchanger) which accumulates heat so as to handle to provide the most suitable product to any need and also allow
consumption rates that may vary greatly over a period of time, while simultaneous use of more energy sources.
also limiting the power used by the generators.

¨ ¨ ¨
Calorifiers with traditional boilers: Calorifiers with biomass boilers: Calorifiers with condensing boilers:
These products are designed for use with conventional The selection of a calorifier while operating in conjunction Condensing boilers are highly efficient and ecologically
boilers which use water as a heating medium in a sealed with a biomass boiler must take account of fact that friendly. They operate at optimum performance when the
or open expansion circuit. The heat exchangers are excessively low return water temperatures could reduce flow water temperature is limited which results in the
designed to handle high flow rates on the primary side the lifespan of the boiler. In addition, a calorifier with return water temperature being as low as possible. This
to ensure that the heat transfer will be efficient while a larger accumulation volume than normal will be more will ensure that the latent heat is
at the same time avoiding excessively low return water suitable as it will act as a buffer which will be beneficial extracted out of the combustion products which will
temperatures. to the biomass boiler. maximise the efficiency of the system.

¨ ¨ ¨
Calorifiers with solar systems: Calorifiers with heat pumps: Calorifiers with steam boilers:
The heat exchange coil surface area is a critical issue Calorifiers operating in conjunction with air-to-water The use of saturated steam as a heating medium to
when interfacing solar thermal systems with calorifiers or water-to-water heat pumps must have extremely produce domestic hot water, although little used in the
due to limited primary flow rates and oversized heat exchange surface areas to ensure that housing sector, is a solution which is still employed in
temperatures. The calorifier must also be capable of heat exchange will take place even when there is a industrial environments where the steam is already in
acting as a buffer to harness the solar energy throughout limited difference in temperature between the primary use for the manufacturing process. Technically speaking,
daylight hours. circuit and secondary stored water. This will maximise steam calorifiers are charactorised by relatively small
the COP (coefficiency of performance) of the heat pump. heat exchangers, as on one hand the steam gives
high heat exchange coefficients and on the other hand
the exchangers usually operate with considerable
differences in temperature between the primary and
secondary circuits.
The use of steam demands a more stringent safety
regeime than the use of low pressure hot water systems
as steam boilers, depending on their capacity and design
pressures, are classified as higher risk and therefore
must comply with the European Pressure Equipment

¨
Directive.

Calorifiers operating with more than one energy source:


The demand to heat a calorifier using more than one
energy source, while at the same time keeping the
various circuits separate, has become much more
common in recent times with the advent of renewable
technologies which usually need to be backed-up with
conventional boilers. In these cases, calorifiers with a
number of heat exchangers are used with the design
ensuring that excellent thermal stratification will be
achieved with minimal interference between the various
heat sources.

4
GUIDE WHEN CHOOSING STORAGE TANKS
DOMESTIC HOT WATER HOT WATER FOR HEATING

A storage tank is a well insulated tank that is inserted in heating Cordivari offers a wide range of storage tanks, which include both
systems powered by a biomass generator. It has the dual function standard versions and a number of combined versions to be used
of allowing the generator to operate in a regular manner, restricting as a single appliance, acting both as a storage tank and to produce
the number of stoppages, and of creating a thermal stabiliser for the domestic hot water.
heating system, thus improving working comfort considerably.

¨ ¨ ¨ ª

Central heating systems with one or more boilers Central heating systems with one or more boilers Combined central heating system and domestic
which are plumbed together and do not generate which are plumbed together in conjunction with hot water production with one or more boilers
domestic hot water. solar power which is connected to either one which are plumbed together.
or two coil type heat exchangers. Domestic hot
water is not generated in these tanks.

¨ ª ¨ ª

Combined central heating system and domestic Combined central heating system and domestic
hot water production with one or more boilers hot water production with one or more boilers
which are plumbed together in conjunction with which are plumbed together in conjunction with
solar power. solar power.

MI
SISTE LARI
ICI SO
TERM

0
201
INO ue
LIST rmiq
ALO s The
GO
CAT
ème

Domestic Hot Water producion (D.H.W.) Heating Water Production Product component nt of a complete Sun Solut
Solution Solar
Thermal System
Please refer Sun Solution Cordivari catalogue

5
CALORIFIERS WITH EXTRACTABLE HEAT EXCHANGER

PIASTRATERM® AND ACCUMULATION TANKS

CALORIFIERS CALORIFIERS WITH FIXED HEAT EXCHANGERS

BOLLYTERM HP (with Heat Pump)

TANK IN TANK CALORIFIERS


HOT WATER

BUFFERS
S
K

MULTI FUEL ENERGY CYLINDERS

PUFFERMAS®
N
A

COMUNICATING BUFFER
T
E

COMBI
R
U

ECO-COMBI
S
S
E

ACCESSORIES
R
P

GALVANIZED CHILLED WATER TANKS


INERTIAL
TANKS

CHILLED WATER TANK AND HEATING TANKS

EXPANSION VESSELS
PRESSURE
WATER

TANKS

ACCESSORIES

TECHNICAL SUPPORT

REGULATIONS
Pag. 12

Pag. 30

Pag. 34

Pag. 38

(3)

Pag. 42
H2(5)
15°

H1(1)

(2)(4) 0
45°

Pag. 46

Pag. 50

Pag. 52

Pag. 54

Pag. 58

Pag. 65

Pag. 75

Pag. 78

350

355
Pag. 80
1”
Gas M

Pag. 84

Pag. 85

Pag. 98
DELIVERY TIME SYMBOLS
A new codification system has been introduced to identify the products in prompt delivery In order to easily choose the most suitable product according to
for customized products delivery time will be agreed when ordering. your needs, Cordivari introduces a useful symbols system that
identify the product according to the best solution for user.

PROMPT DELIVERY
Grey highlighted products are
dispatched in 1-5 working days.
(Delivery time excluded)

NOVITÀ

EXTRA 1 -2- 3 Extractable PUFFER 2 Thermographic images that show PUFFERMAS® Plate Heat Exchanger
Heat exchanger for EASY STRATIFICATION how a system works with a Easy
legionellosis-prophylaxis BUFFER Stratification Buffer

NOVITÀ

STORAGE TANKS DHW Corrugated Pipe NEW “EXTRA PLUS” RANGE BOLLYTERM HP Themodynamical calorifier INTERKA SOLARE
ECO-COMBI 3 WITH EXTRACTABLE (Heat Pump) with Heat Pump
FINNED COILS

Legionellosis prophylaxis heat exchanger Pressures


Curved pipes ensure: Pressures from 8 to 10 bars ensure that the calorifier is suitable
• a real heating of the entire quantity of water in an homogenous way also for big installation
• real reduction of legionellosis bacteria’s diffusion
• energy saving

Crash-absorbing flange covers Electrical heating integration


The new soft flange cover allows to control the flange at any Available as accessories electrical immersions with thermostat
time without operating on the connections and protection grade IP45 are supplied as integrational heater
for calorifiers. The heater are in Stainless Steel, available for
voltage 220 V - 400 V , and with power from 1,5 to 18 Kw.

New BOLLYTERM HP Titanium electronic anode


New thermodynamical producer of Domestic Hot Water with Available only as accessories. It doesn’t need periodic controls
Heat Pump. Thanks to the integration with the solar system the ensuring a real and regular protection, for long time. It is not
best of renewable energies are achieved . subject to consumption or replacement.

New "Labyrinth Spreader" (Cordivari patented): Cathode protection (equipped)


Guarantees excellent performances thanks to the perfect Cordivari calorifiers are equipped with Magnesium Anode
stratification of the water re-entering the tank. already mounted , that allows just with a visual checking the
real consumption of the magnesium bar, without necessarily
draining the calorifier.

Drain ECO-COMBI 2 “DOMUS”


Drain pipe is welded as standard, in order to have an easier It is the innovative solution that join production and storage of
installation and a total drain sanitary hot water and heating water.
The New Eco Combi 2 Domus has been developed to satisfy
specific needs of combined solar system for small-medium
locations.

8
TECHNICAL INNOVATION FOR A BETTER HANDLING
Calorifiers Support and handle system for all capacities equal or over 1500 lts (version Polywarm®). Already mounted under the calorifiers, there is a special
support, called “skirt” with holes to move it with forklift, so that you can easily handle them without using pallets, other support, or cranes.

1- Insulation ready to be open


2- Opening Insulation with support skilt and handling
3- Handling
4- Particular of calorifier backview

PATENTED
1 2 3 4

TECHNICAL INNOVATION FOR WATER HYGIENE


5 TECHNICAL SOLUTION OF CORDIVARI PRODUCTS 1 PUFFERMAS®
For a total hygenical protection the PUFFERMAS® buffer tank uses accumulated
AGAINST LEGIONELLOSYS: heating water to exchange heat energy with domestic water throgh the MACS®,
Cordivari proposes various technical solution to prevent legionellosis bacteria’s station. The continuosly production of D.H.W. without any accumulation of domestic
diffusion in the Sanitary hot water, ensuring Health and drinkableness. water grant total prevention against Legionellosys.
Plate heat
Primary Exchanger
Circuit

Sanitary
Circuit

2 DOUBLE-BOTTOM CALORIFERS 3 HEAT EXCHANGER FOR LEGIONELLOSIS-PROPHYLAXIS


Cordivari propose on BOLLY 2 DF an exchanging double-bottom: where DHW at the Cordivari Heat Exchanger , with tubes bent to the bottom, is able to heat the complete
bottom part of the calorifier can be kept at safe temperature to prevent any bacterial quantity of water in an homogenous way, also in the bottom area of the calorifier. This
diffusions. will ensure complete healthiness of the sanitary hot water

Bended heat
exchanger

4 COMBINED WATER HEATERS 5 “EASY CONTROL” ELECTRONIC DISPLAY


Storage of sanitary water in the combined calorifier (V2), is totally soaked in the “EASY CONTROL” Electronic Display mounted on Cordivari calorifiers allows also to
Primary Circuit (V1) being so at the safe temperature for legionellosis-phophylaxis. plan periodically sanitary water heating in order to ensure its healthiness.

D.H.W. storage
H7 (11) (13)
H6 (10)

H10 (12)
H4 (6) (8)
H5 (9)
Primary circuit
H9 (7) storage
H

H3 (5)

H8 (15)

WHAT IS LEGIONELLOSIS
70 Immediate bacterium death

90% Bacterium death


60 (within 2 minutes )
90% Bacterium death Legionnaire’s deseases means all the infections caused by legionellosis bacteria.
50 (within 2 hours )
You can take it simply breathing infected vaporized water, and in such case it can cause the death.
40 Legionellosis can widespread with temperatures between 25° up to 42°C reaching its ideal temperature at 37° C
Perfect temperature
for bacterium growing
30 To avoid any risk , water tank has to accumulate at high “safety temperature”
20
Bacterium are alive
10 but they are not reactive

9
MATERIALS AND COATINGS
FOR D.H.W. AND HYGIENE
STAINLESS STEEL 316L
Material with high performances, entirely hygienic and atossic, suitable for Domestic
Hot Water (D. M. 174 del 06.04.04)

POLYWARM®
Internal coating with high performance for entirely hygienic, highly resistant to
thermal and impact shocks.
ANVER 2003 award winner. Suitable for Domestic Hot Water (D. M. 174 del
06.04.04)

10
CALORIFIERS &
BUFFER TANKS

11
BOL. EXTRA 1 XXC VT
INSULATED STAINLESS STEEL 316L CALORIFIERS WITH 1 EXTRACTABLE HEAT EXCHANGER

STAINLESS STEEL 316L Capacity


BOL. EXTRA1 XXC VT Heat Exchanger
Weight
STAINLESS STEEL 316L EXCHANGER Surface
[liters] ART. NR. Price [€] [m2] [Kg]
200 3072052300002 2.102,00 0,5 59
300 2.381,00 0,75 74

EXTRA 1 L
3072052300003

IGNITION TIME
500 3072052300004 3.018,00 1 98
1000 3072052300006 5.021,00 2 176
1 00
1500 3072052300007 8.050,00 3 264
2000 3072052300008 9.827,00 4 327
3000 3072052300010 on request 5 511
4000 3072052300011 on request 8 676
5000 3072052300013 on request 10 779

1500 3072052301007 6.978,00 1,5 242

EXTRA 1 M
IGNITION TIME 2000 3072052301008 8.250,00 2 307
STORAGE EXCHANGER 3000 3072052301010 on request 2,5 499
1 30
Pmax Tmax Pmax Tmax 4000 3072052301011 on request 4 647
8 bar 95° C 12 bar 99° C 5000 3072052301013 on request 5 743
For those products available on request , prices and delivery time should be agreed when ordered

PROMPT DELIVERY
Grey highlighted products are
dispatched in 1-5 working days.
(Delivery time excluded)

Technical descriptions Insulation Heat exchanger:


Stainless Steel 316L vertical calorifier suitable for drinkable 50 mm soft polyurethane foam. Thermal conductivity: Curved Legionella prophylaxis type in Stainless Steel 316L
water according to to D.M N 174 dated 16 04 04. 0.038 W/mK. suitable for potable water in accordance with D.M. N°
The thermal exchanger is ensured by the innovative Heat 174 dated 16 04 04.
External lining
Exchanger for legionellosis-prophilaxis, with tubes bent to SCAI red Ral 3000 complete with upper trims and flange Thanks to the Antilegionella heat exchanger the ignition
the bottom, reducing legionellosis bacteria’s diffusion and cover. time refers to the total volume of the tank. With straight
improving the heating performance. exchanger time refers to 85% of the volume.
Drain pipe
Application External confluence through jointable pipe. Cathode protection
Production and Storage of sanitary hot water for domestic Magnesium anode with Anoden-tester which facilitates an
and industrial uses. Warranty easy check of the magnesium bar condition. For capacity >
- 5 years
See general sales conditions and warranty. 1500lt n°2 magnesium anode.

Gasket-Flange Plate
- Silicone gaskets suitable for alimentary use for max
temperature up to 200° C. (D.M. n.174 dated 2004);
- Corrosion proofing flange cover.

Datas have been calculated on following basis:


1) Primary circuit at 80°C and proper energy source;
2) Production of DHW in continue way from 10 to 45°C.
3) DHW that can be taken in the fist 10’ and in the first hour from storage at 60°C, input 10°C and output 45°C;
4) Sanitary water not scaling.
Even if tanks are tested to resist from Max temperature 60°C to 95°C, the local legislation has always to be observed during the use.

Continous Storage DHW produced in the first DHW produced in the Flow
Capacity Ignition Time Output Exchanger pressure loss
production of DHW volume 10 Min. first hour rate
[liters] [min] [KW] [lt/h] [liters] [liters] [liters] [m3/h] [mm.c.a.] [mbar]
200 49 18 455 190 347 635 2 309 30,3
300 48 28 701 285 524 968 3 372 36,5
EXTRA 1 L

500 60 38 947 480 844 1443 4 419 41,1


1000 54 86 2127 995 1776 3123 10 1380 135,3
1500 53 133 3290 1490 2677 4761 15 2295 225,1
2000 52 180 4453 1975 3564 6384 20 2996 293,8
3000 65 216 5361 2975 5144 8539 20 2436 238,9
4000 57 330 8168 3890 6918 12092 20 3896 382,1
5000 60 401 9921 4890 8639 14923 20 4707 461,6

1500 95 59 1813 1490 2431 3579 15 4346 426,2


EXTRA 1 M

2000 98 94 2328 1975 3209 4684 15 5210 510,0


3000 121 116 2871 2975 4729 6547 15 3779 370,6
4000 102 180 4453 3890 6299 9120 20 2996 293,8
5000 108 216 5348 4890 7877 11264 20 2436 238,9

12
CONNECTIONS

De 1 Drain 3/4’’ Gas F (from 200 to 1000 Lt)


Df 2 Domestic Cold Water Circuit Inlet

CALORIFIERS
(14) Alternative Domestic Cold Water Circuit Inlet
3
or connection for more boilers
4 Primary Circuit Outlet
5 Heat Exchanger Flange
H17 (11) 6 Primary Circuit Inlet
(12) (13)
H16 (10) 7 Connection for thermostat 1/2" Gas F
H15 (9) 8 Connection for magnesium anode 1” 1/4 Gas F
Connection for 2nd Anode 1” 1⁄4 Gas F
9
(only for capacity > 1500 Lt)
10 Connection for electrical immersion resistance 1” 1/2 Gas F
A

11 - 13 Connection for recirculation or for Domestic Hot water delivery


H

12 Connection for thermometer 1/2" Gas F


H7 (8)
H6 (7) 14 Domestic Hot Water Circuit Outlet
H4 (5) 16 Air Ventil Heat Exchanger 3/8” Gas F

On request:
H2 (2) (3) "EASY CONTROL” Electronic Display mounted
and connected.
Available as accessories - Euro 408,00 – see
page 70
H1 (1)
0

(16)
H5 (6)
(14)
(1) (2) (11) (3) (13)
H3 (4)

(7) (10) (12) (8) (9)

(4) (5) (6) (16)


P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

Net 2-3
Capacity Df De H A H1 H2 H3 H4 H5 H6 H7 H15 H16 H17 5 1 14
Volume 11-13
[liters] [liters] [mm] Connections Gas F

200 188 450 550 1441 1463 64 316 351 401 451 511 751 // 1066 1176 Øe 300 3/4" 1"1/4 1"1/4

300 289 550 650 1550 1578 123 400 435 485 535 595 835 // 1150 1260 Øe 300 3/4" 1"1/4 1"1/4

500 497 650 750 1841 1873 114 416 451 501 551 611 976 // 1370 1526 Øe 300 3/4" 1"1/4 1"1/4

1000 1037 850 950 2192 2235 89 454 499 589 679 739 1139 // 1660 1814 Øe 380 3/4" 1"1/2 1"1/2

1500 1489 950 1050 2495 2540 72 480 525 615 705 765 1290 // 1935 2090 Øe 380 1" 1"1/2 2"

2000 2052 1100 1200 2517 2576 54 535 612 717 822 892 867 1957 1905 2082 Øe 430 1" 2" 2"

3000 2983 1250 1350 2891 2958 82 603 688 793 898 968 993 2233 2249 2408 Øe 430 1" 2" 2"

4000 4003 1450 1550 2860 2950 57 642 715 820 925 995 1000 2210 2163 2335 Øe 430 1" 2" 2"

5000 4935 1600 1700 2925 3032 36 646 732 837 942 1012 1017 2237 2207 2362 Øe 430 1" 2" 2"

13
BOL. EXTRA 1 WRC/WXC VT
INSULATED POLYWARM® CALORIFIERS WITH 1 EXTRACTABLE HEAT EXCHANGER

BOL. EXTRA1 WRC VT BOL. EXTRA1 WXC VT Heat Exchan-


Capacity Weight
COPPER EXCHANGER STAINLESS STEEL 316L EXCHANGER ger Surface
[liters] ART. NR. Price [€] ART. NR. Price [€] [m2] [Kg]
POLYWARM®

200 3072162350002 1.008,00 3072162360002 1.079,00 0,5 61


300 3072162350003 1.185,00 3072162360003 1.273,00 0,75 74

EXTRA 1 L
IGNITION TIME
500 3072162350004 1.490,00 3072162360004 1.570,00 1 108
800 3072162350005 1.825,00 3072162360005 2.030,00 1,5 156
1 00
1000 3072162350006 2.131,00 3072162360006 2.413,00 2 198
1500 3072162350007 2.789,00 3072162360007 3.180,00 3 264
2000 3072162350008 3.626,00 3072162360008 3.976,00 4 334
3000 3072162350009 4.568,00 3072162360009 5.021,00 5 519
4000 3072162350010 6.083,00 3072162360010 6.730,00 8 633
5000 3072162350012 7.291,00 3072162360012 7.730,00 10 775

1500 3072162351007 2.444,00 3072162361007 2.812,00 1,5 242

EXTRA 1 M
IGNITION TIME 2000 3072162351008 3.192,00 3072162361008 3.387,00 2 307
STORAGE EXCHANGER 3000 3072162351009 4.063,00 3072162361009 4.365,00 2,5 507
1 30
Pmax Tmax Pmax Tmax 4000 3072162351010 5.404,00 3072162361010 5.804,00 4 604
8 bar 90° C 12 bar 99° C 5000 3072162351012 6.295,00 3072162361012 6.714,00 5 734

PROMPT DELIVERY
Grey highlighted products are
dispatched in 1-5 working days.
(Delivery time excluded)

Technical descriptions
Carbon steel Polywarm® coated vertical calorifier suitable Insulation Heat exchanger:
for drinkable water according to to D.M N 174 dated 16 50 mm soft polyurethane foam. Thermal conductivity: Curved Legionella prophylaxis type in Stainless Steel 316L
0.038 W/mK.
04 04. or Copper suitable for potable water in accordance with
The thermal exchanger is ensured by the innovative Heat External lining D.M. N° 174 dated 16 04 04.
Exchanger for legionellosis-prophilaxis, with tubes bent to SCAI red Ral 3000 complete with upper trims and flange Thanks to the Antilegionella heat exchanger the ignition
the bottom, reducing legionellosis bacteria’s diffusion and cover. time refers to the total volume of the tank. With straight
improving the heating performance. exchanger time refers to 85% of the volume.
Drain pipe
Application External confluence through jointable pipe. Cathode protection
Production and Storage of sanitary hot water for domestic Magnesium anode with Anoden-tester which facilitates an
and industrial uses. Warranty
- 5 years easy check of the magnesium bar condition. For capacity >
See general sales conditions and warranty. 1500lt n°2 magnesium anode.
Electronic anode on request (see page 71)

Gasket-Flange Plate
- Silicone gaskets suitable for alimentary use for max
temperature up to 200° C. (D.M. n.174 dated 2004);
- Corrosion proofing flange cover.

Datas have been calculated on following basis:


1) Primary circuit at 80°C and proper energy source;
2) Production of DHW in continue way from 10 to 45°C.
3) DHW that can be taken in the fist 10’ and in the first hour from storage at 60°C, input 10°C and output 45°C;
4) Sanitary water not scaling.
Even if tanks are tested to resist from Max temperature 60°C to 95°C, the local legislation has always to be observed during the use.
Continous Storage DHW produced in the first DHW produced in the Flow
Capacity Ignition Time Output Exchanger pressure loss
production of DHW volume 10 Min. first hour rate
3
[liters] [min] [KW] [lt/h] [liters] [liters] [liters] [m /h] [mm.c.a.] [mbar]
200 49 18 455 190 347 635 2 309 30,3
300 48 28 701 285 524 968 3 372 36,5
EXTRA 1 L

500 60 38 947 480 844 1443 4 419 41,1


800 59 59 1466 740 1301 2230 6 718 70,4
1000 54 86 2127 995 1776 3123 10 1380 135,3
1500 53 133 3290 1490 2677 4761 15 2295 225,1
2000 52 180 4453 1975 3564 6384 20 2996 293,8
3000 65 216 5361 2975 5144 8539 20 2436 238,9
4000 57 330 8168 3890 6918 12092 20 3896 382,1
5000 60 401 9921 4890 8639 14923 20 4707 461,6

1500 95 59 1813 1490 2431 3579 15 4346 426,2


EXTRA 1 M

2000 98 94 2328 1975 3209 4684 15 5210 510,0


3000 121 116 2871 2975 4729 6547 15 3779 370,6
4000 102 180 4453 3890 6299 9120 20 2996 293,8
5000 108 216 5348 4890 7877 11264 20 2436 238,9

14
CONNECTIONS

De 1 Drain 3/4’’ Gas F (from 200 to 1000 Lt)


Df 2 Domestic Cold Water Circuit Inlet

CALORIFIERS
(14) 3
Alternative Domestic Cold Water Circuit Inlet
or connection for more boilers
4 Primary Circuit Outlet
5 Heat Exchanger Flange
H17 (11) 6 Primary Circuit Inlet
(12) (13) 7 Connection for thermostat 1/2" Gas F
H16 (10)
8 Connection for magnesium anode 1” 1/4 Gas F
H15 (9) Connection for 2nd Anode 1” 1⁄4 Gas F
9
(only for capacity over 1500 Lt)
10 Connection for electrical immersion resistance 1” 1/2 Gas F
11 - 13 Connection for recirculation or for Domestic Hot water delivery
A

12 Connection for thermometer 1/2" Gas F


H

14 Domestic Hot Water Circuit Outlet


H7 (8) 15 Drain 1” Gas F (only for capacities >1000 lt)
H6 (7) 16 Air Ventil Heat Exchanger 3/8” Gas F
H4 (5) On request:
"EASY CONTROL” Electronic Display mounted
and connected.
H2 (2) (3) Available as accessories - Euro 408,00 – see
page 70

H1 (1) (15)
0

(16) Tanks from 1500 to 5000 liters (Polywarm® version)


have two gripps on the bottom which allows the use
H5 (6)
(14) of forklift when handling.
(1) (2) (11) (3) (13)
H3 (4)

(7) (10) (12) (8) (9)


H1 (15)

(4) (5) (6) (15) (16)


P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

Net 2-3
Capacity Df De H A H1 H2 H3 H4 H5 H6 H7 H15 H16 H17 5 14
Volume 11-13
[liters] [liters] [mm] Conn. Gas F

200 188 450 550 1441 1463 64 316 351 401 451 511 751 // 1066 1176 Øe 300 1”1/4 1”1/4

300 289 550 650 1550 1578 123 400 435 485 535 595 835 // 1150 1260 Øe 300 1”1/4 1”1/4

500 497 650 750 1841 1873 114 416 451 501 551 611 976 // 1370 1526 Øe 300 1”1/4 1”1/4

800 789 750 850 2138 2174 101 433 478 568 658 718 1118 // 1638 1793 Øe 380 1”1/4 1”1/4

1000 1037 850 950 2192 2235 89 454 499 589 679 739 1139 // 1660 1814 Øe 380 1”1/2 1”1/2

1500 1489 950 1050 2497 2540 106 492 537 627 717 777 1302 // 1947 2102 Øe 380 1”1/2 2”

2000 2052 1100 1200 2574 2630 93 535 655 760 865 935 909 2000 1945 2125 Øe 430 2” 2”

3000 2983 1250 1350 2917 2982 137 603 723 828 933 1003 1028 2268 2285 2443 Øe 430 2” 2”

4000 4003 1450 1550 2922 3010 112 642 762 867 972 1042 1047 2257 2210 2382 Øe 430 2” 2”

5000 4935 1600 1700 2959 3061 92 646 766 871 976 1046 1051 2271 2241 2396 Øe 430 2” 2”

15
BOL. EXTRA 2 XXC VT
INSULATED STAINLESS STEEL 316L CALORIFIERS WITH 2 EXTRACTABLE HEAT EXCHANGERS

STAINLESS STEEL 316L BOL. EXTRA2 XXC VT


Capacity
STAINLESS STEEL 316L EXCHANGER
[liters] ART. NR. Price [€]
200 3082052300001 2.628,00
300 3082052300002 3.162,00
500 3082052300003 3.888,00
1000 3082052300005 6.453,00
1500 3082052300006 9.188,00
2000 3082052300007 on request
3000 3082052300009 on request
4000 3082052300010 on request
5000 3082052300012 on request
Even if tanks are tested to resist from Max temperature
60°C to 95°C, the local legislation has always to be
observed during the use.
STORAGE EXCHANGER
Pmax Tmax Pmax Tmax
For those products available on request , prices and
8 bar 95° C 12 bar 99° C
delivery time should be agreed when ordered.

Technical descriptions Insulation Heat exchangers:


Stainless Steel 316L vertical calorifier suitable for drinkable 50 mm soft polyurethane foam. Thermal conductivity: - Lower Legionellosis prophylaxis coil
water according to to D.M N 174 dated 16 04 04. 0.038 W/mK. Stainless Steel 316L Curved Pipe, suitable for drinking
The thermal exchanger is ensured by the innovative Heat water according to D.M N 174 dated 16 04 04.
External lining
Exchanger for legionellosis-prophilaxis, with tubes bent to SCAI red Ral 3000 complete with upper trims and flange - Upper straight
the bottom, reducing legionellosis bacteria’s diffusion and cover. Stainless Steel 316L
improving the heating performance.
Drain pipe Cathode protection
Application External confluence through jointable pipe Magnesium anode with Anoden-tester which allows to
Production and storage of Sanitary Hot Water for civil and check easily the real consumption of the magnesium bar.
industrial systems, based on a double energy sources, such Warranty For capacity > 1500lt n°2 magnesium anode.
as solar panels combined with an integration source. - 5 years
See general sales conditions and warranty.
Gasket-Flange Plate
- Silicone gaskets suitable for alimentary use for max
temperature up to 200° C. (D.M. n.174 dated 2004);
- Corrosion proofing flange cover.

Heat Exchangers Surface Calorifier


Capacity
Lower Upper Weight
[liters] [m2] [Kg]

200 0,5 0,5 76,8

300 0,75 0,75 96,6

500 1,5 1,5 134,0

1000 3 2 223,3

1500 3 3 312,1

2000 4 4 396,8

3000 5 5 582,4

4000 8 8 771,4

5000 10 10 891,8
For graphics and exchanger pressure loss data see page 92

16
CONNECTIONS
De
Df 1 Drain 3/4” Gas F (from 200 to 1000lt)
(18) 2 Domestic Cold Water Circuit Inlet

CALORIFIERS
Alternative Domestic Cold Water Circuit Inlet
3
or connection for more boilers
4 Primary Circuit Outlet – Lower Exchanger
H17 (15) 5 Lower exchanger Flange
(16) (17) 6 Primary Circuit – Inlet Lower exchanger
H16 (14)
7-12 Connection for thermostat 1/2" Gas F
H15 (13)
8 Connection for magnesium anode 1” 1/4 Gas F
9 Primary Circuit Outlet – Upper Exchanger
H11 (12) 10 Upper Exchanger Flange
11 Primary Circuit Inlet – Upper Exchanger
A

H9 (10) Connection for the 2nd anode 1”1/4 Gas F


13
(available only on >1500 lt )
H

H7 (8)
14 Connection for electrical immersion resistance 1”1/2 Gas F

H6 (7) 15-17 Connection for recirculation or for Domestic Hot water delivery
H4 (5) 16 Connection for thermometer 1/2” Gas F

H2 (2) (3) 18 Domestic Hot water outlet


19-20 Air Ventil Heat Exchagers 3/8” Gas F
21 Drain 1” Gas F (only for capacities >1000 lt)

H1 (1)
0

(20)
H10 (11)

H8 (9)

(19)
H5 (6)
(18)
(1) (2) (15) (3) (17)
H3 (4)

(7) (12) (14) (16) (8) (13)

(4) (5) (6) (9) (10)


(11) (19) (20) (21)
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

Net 2-3 4-6


Cap. Df De H A H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11 H15 H16 H17 5-10 18
Volume 15-17 9-11
[liters] [liters] [mm] Connections Gas F

200 188 450 550 1441 1463 64 316 351 401 451 511 701 801 851 901 961 // 1066 1176 Øe 300 1”1/4 1” 1”1/4

300 289 550 650 1550 1578 123 400 435 485 535 595 785 885 935 985 1045 // 1150 1260 Øe 300 1”1/4 1” 1”1/4

500 497 650 750 1841 1873 114 416 451 501 551 611 801 901 951 1001 1061 // 1370 1526 Øe 300 1”1/4 1” 1”1/4

1000 1037 850 950 2192 2235 89 454 499 589 679 739 989 1049 1139 1229 1289 // 1660 1814 Øe 380 1”1/2 2” 1”1/2

1500 1489 950 1050 2497 2540 106 493 538 628 718 778 1128 1213 1303 1393 1453 // 1948 2103 Øe 380 1”1/2 2” 2”

2000 2052 1100 1200 2574 2630 93 535 655 760 865 935 909 1225 1330 1435 1505 2000 1945 2125 Øe 430 2” 2” 2”

3000 2983 1250 1350 2917 2982 137 604 724 829 934 1004 1028 1424 1529 1634 1704 2269 2285 2444 Øe 430 2” 2” 2”

4000 4003 1450 1550 2922 3010 112 642 762 867 972 1042 1047 1304 1567 1514 1742 2257 2210 2382 Øe 430 2” 2” 2”

5000 4935 1600 1700 2959 3061 92 646 766 871 976 1046 1051 1466 1571 1676 1746 2271 2241 2396 Øe 430 2” 2” 2”

17
BOL. EXTRA 2 WRC/WXC VT
INSULATED POLYWARM® CALORIFIERS WITH 2 EXTRACTABLE HEAT EXCHANGERS

BOL. EXTRA2 WRC VT BOL. EXTRA2 WXC VT


Capacity
COPPER EXCHANGER STAINLESS STEEL 316L EXCHANGER
[liters] ART. NR. Price [€] ART. NR. Price [€]
POLYWARM®

200 3082162350001 1.403,00 3082162360001 1.545,00


300 3082162350002 1.605,00 3082162360002 1.772,00
500 3082162350003 2.168,00 3082162360003 2.363,00
800 3082162350004 2.787,00 3082162360004 3.115,00
1000 3082162350005 3.165,00 3082162360005 3.616,00
1500 3082162350006 3.993,00 3082162360006 4.468,00
2000 3082162350007 4.953,00 3082162360007 5.405,00
3000 3082162350009 6.279,00 3082162360009 7.255,00
4000 3082162350010 8.657,00 3082162360010 9.995,00
5000 3082162350012 10.282,00 3082162360012 11.071,00
Even if tanks are tested to resist from Max temperature 60°C to 90°C, the local
legislation has always to be observed during the use.

STORAGE EXCHANGER
PROMPT DELIVERY
Pmax Tmax Pmax Tmax Grey highlighted products are
8 bar 90° C 12 bar 99° C dispatched in 1-5 working days.
(Delivery time excluded)

Technical descriptions Insulation Heat exchangers:


Carbon steel Polywarm® coated vertical calorifier suitable 50 mm soft polyurethane foam. Thermal conductivity: - Lower Legionellosis prophylaxis coil
for drinkable water according to to D.M N 174 dated 16 0.038 W/mK. Stainless Steel 316L or Copper Curved Pipe, suitable for
04 04. drinking water according to D.M N 174 dated 16 04 04.
External lining
The thermal exchanger is ensured by the innovative Heat SCAI red Ral 3000 complete with upper trims and flange - Upper straight coil
Exchanger for legionellosis-prophilaxis, with tubes bent to cover. Stainless Steel 316L or Copper Pipe
the bottom, reducing legionellosis bacteria’s diffusion and
improving the heating performance. Drain pipe Cathode protection
External confluence through jointable pipe Magnesium anode with Anoden-tester which allows to
Application check easily the real consumption of the magnesium bar.
Production and storage of Sanitary Hot Water for civil and Warranty For capacity > 1500lt n°2 magnesium anode.
industrial systems, based on a double energy sources, such - 5 years
as solar panels combined with an integration source. See general sales conditions and warranty. Electronic anode on request (see page 71)

Gasket-Flange Plate
- Silicone gaskets suitable for alimentary use for max
temperature up to 200° C. (D.M. n.174 dated 2004);
- Corrosion proofing flange cover.

Heat Exchangers Surface Calorifier


Capacity
Lower Upper Weight
[liters] [m2] [Kg]

200 0,5 0,5 79,8

300 0,75 0,75 96,6

500 1,5 1,5 149

800 2 2 199

1000 3 2 247,3

1500 3 3 314,1

2000 4 4 403,8

3000 5 5 492,4

4000 8 8 729,4

5000 10 10 887,8
For graphics and exchanger pressure loss data see page 92

18
CONNECTIONS
De
Df 1 Drain 3/4” Gas F (from 200 to 1000lt)
(18) 2 Domestic Cold Water Circuit Inlet

CALORIFIERS
Alternative Domestic Cold Water Circuit Inlet
3
or connection for more boilers
4 Primary Circuit Outlet – Lower Exchanger
H17 (15) 5 Lower exchanger Flange
(16) (17) 6 Primary Circuit Inlet – Lower exchanger
H16 (14)
7-12 Connection for thermostat 1/2" Gas F
H15 (13)
8 Connection for magnesium anode 1” 1/4 Gas F
9 Primary Circuit Outlet – Upper Exchanger
H11 (12) 10 Upper Exchanger Flange
11 Primary Circuit Inlet – Upper Exchanger
A

H9 (10) Connection for the 2nd anode 1”1/4 Gas F


13
(available only on >1500 lt )
H

H7 (8)
14 Connection for electrical immersion resistance 1”1/2 Gas F

H6 (7) 15-17 Connection for recirculation or for Domestic Hot water delivery
H4 (5) 16 Connection for thermometer 1/2” Gas F

H2 (2) (3) 18 Domestic Hot water outlet


19-20 Air Ventil Heat Exchagers 3/8” Gas F
21 Drain 1” Gas F (only for capacities >1000 lt)

H1 (1)
0

(20)
H10 (11)

H8 (9)

(19)
Tanks from 1500 to 5000 liters (Polywarm® version)
H5 (6) have two gripps on the bottom which allows the use
(18)
(1) (2) (15) (3) (17) of forklift when handling.
H3 (4)

(7) (12) (14) (16) (8) (13)


H1 (21)

(4) (5) (6) (9) (10)


(11) (19) (20) (21)

Net 2-3 4-6


Cap. Df De H A H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11 H15 H16 H17 5-10 18
Volume 15-17 9-11
[liters] [liters] [mm] Connections Gas F

200 188 450 550 1441 1463 64 316 351 401 451 511 701 801 851 901 961 // 1066 1176 Øe 300 1”1/4 1” 1”1/4

300 289 550 650 1550 1578 123 400 435 485 535 595 785 885 935 985 1045 // 1150 1260 Øe 300 1”1/4 1” 1”1/4

500 497 650 750 1841 1873 114 416 451 501 551 611 801 901 951 1001 1061 // 1370 1526 Øe 300 1”1/4 1” 1”1/4

800 789 750 850 2138 2174 101 433 478 568 658 718 898 1028 1118 1208 1268 // 1638 1793 Øe 380 1”1/4 2” 1”1/4

1000 1037 850 950 2192 2235 89 454 499 589 679 739 989 1049 1139 1229 1289 // 1660 1814 Øe 380 1”1/2 2” 1”1/2

1500 1489 950 1050 2497 2540 106 493 538 628 718 778 1128 1213 1303 1393 1453 // 1948 2103 Øe 380 1”1/2 2” 2”

2000 2052 1100 1200 2574 2630 93 535 655 760 865 935 909 1225 1330 1435 1505 2000 1945 2125 Øe 430 2” 2” 2”

3000 2983 1250 1350 2917 2982 137 604 724 829 934 1004 1028 1424 1529 1634 1704 2269 2285 2444 Øe 430 2” 2” 2”

4000 4003 1450 1550 2922 3010 112 642 762 867 972 1042 1047 1304 1567 1514 1742 2257 2210 2382 Øe 430 2” 2” 2”

5000 4935 1600 1700 2959 3061 92 646 766 871 976 1046 1051 1466 1571 1676 1746 2271 2241 2396 Øe 430 2” 2” 2”

19
BOL. EXTRA3 WRC/WXC VT
INSULATED POLYWARM® CALORIFIERS WITH 3 EXTRACTABLE HEAT EXCHANGERS

BOL. EXTRA3 WRC VT BOL. EXTRA3 WXC VT


Capacity
COPPER EXCHANGER STAINLESS STEEL 316L EXCHANGER
[liters] ART. NR. Price [€] ART. NR. Price [€]
POLYWARM®

200 3092162350001 1.884,00 3092162360001 2.067,00


300 3092162350002 2.161,00 3092162360002 2.414,00
500 3092162350003 2.679,00 3092162360003 2.956,00
800 3092162350004 3.419,00 3092162360004 3.713,00
1000 3092162350005 3.913,00 3092162360005 4.278,00
1500 3092162350006 4.635,00 3092162360006 5.068,00
2000 3092162350007 6.002,00 3092162360007 6.515,00
3000 3092162350009 7.738,00 3092162360009 8.421,00
4000 3092162350010 10.112,00 3092162360010 11.441,00
5000 3092162350012 11.878,00 3092162360012 13.687,00
STORAGE EXCHANGER
Pmax Tmax Pmax Tmax PROMPT DELIVERY
8 bar 90° C 12 bar 99° C Grey highlighted products are
dispatched in 1-5 working days.
(Delivery time excluded)

Technical descriptions Insulation Heat exchangers:


Cordivari offers one type of coating/material for vertical 50 mm soft polyurethane foam. Thermal conductivity: - Lower Legionellosis prophylaxis coil
Extra3 Sanitary Hot Water Heaters with 3 extractable Heat 0.038 W/mK. Stainless Steel 316L or Copper Curved Pipe,
Exchangers: suitable for drinking water according to D.M N
External lining 174 dated 16 04 04
- Carbon steel Inside coated with Polywarm® according to SCAI red Ral 3000 complete with upper trims and flange - Upper and middle coils
D.M N 174 dated 16 04 04 cover. Straight Stainless Steel 316L or Copper Pipe
The thermal exchanger is ensured by the innovative Heat Drain pipe Cathode protection
Exchanger for legionellosis-prophilaxis, with tubes bent to External confluence through jointable pipe Magnesium anode with Anoden-tester which allows to
the bottom, reducing legionellosis bacteria’s diffusion and check easily the real consumption of the magnesium bar.
improving the heating performance. Warranty For capacity > 1500lt n°2 magnesium anode.
- 5 years Electronic anode on request (see page 71)
Application See general sales conditions and warranty
Production and storage of Sanitary Hot Water for civil Gasket-Flange Plate
and industrial systems, based on multy-energy sources,
such as solar panels combined with heat pump and an - Silicone gaskets suitable for alimentary use for max
integration source. temperature up to 200° C. (D.M. n.174 dated 2004);
- Corrosion proofing flange cover.

P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

Heat Exchangers Surface Calorifier


Capacity
[m2] Weight
[liters] Lower Middle Upper Total Surface [Kg]

200 0,75 0,5 0,5 1,75 90

300 1 1 0,75 2,75 109

500 1,5 1,5 1 4 144

800 2 2 1 5 212

1000 3 2 1,5 6,5 247

1500 3 3 1,5 7,5 325

2000 4 4 2 10 478

3000 5 5 3 13 608

4000 8 8 4 20 836

5000 10 10 5 25 994
For graphics and exchanger pressure loss data see page 92

20
De
CONNECTIONS
Df 1 Drain 3/4” Gas F (from 200 lt to 1.000 lt)
(21) 2 Domestic Cold Water Circuit Inlet
Alternative Domestic Cold Water Circuit Inlet
3
or connection for more boilers

CALORIFIERS
4 Primary Circuit Outlet – Lower Exchanger
H17 (15) 5 Lower exchanger Flange
(16) (17) (18) 6 Primary Circuit Inlet – Lower exchanger
H15 (13) 7-12 Connection for thermostat 1/2" Gas F
H13 (14) 8 Connection for magnesium anode 1” 1/4 Gas F
9 Primary Circuit Outlet – Middle Exchanger
10 Middle exchanger flange
H11 (12) ANODEN TESTER 11 Primary Circuit Inlet – Middle Exchanger
Connection to 2nd anode 1”1/4 Gas F
13
H9 (10) (available only on >1500 lt)
A

14 Upper Exchanger Flange


H

H7 (8) 15-18 Connection for recirculation or for Domestic Hot water delivery
16-17 Connection for thermometer/thermostat 1/2” Gas F
H6 (7) 19 Primary Circuit Outlet – Upper Exchanger
20 Primary Circuit Inlet – Upper Exchanger
H4 (5)
21 Domestic Hot water outlet
H2 (2) (3) 22 Drain 1” Gas F (only for capacities >1000 lt)
23-24-25 Air Ventil Heat Exchagers 3/8” Gas F

H1 (1)
0
(25)
H14 (20)
H12 (19)

(24)
H10 (11)

H8 (9)

(23) Tanks from 1500 to 5000 liters (Polywarm® version) have


H5 (6) two gripps on the bottom which allows the use of forklift
(21) when handling.
(1) (2) (15) (3) (18)
H3 (4)

(7) (12) (16) (8) (13) (17)


H1 (22)

(4) (5) (6) (9) (10) 5)


(11) (14) (19) (20)
(22) (23) (24) (25)

Net 2-3 4-6 19


Cap. Weight Df De H A H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11 H12 H13 H14 H15 H17 5-10 14 21
Vol. 15-18 9-11 20
[liters] [liters] [Kg] [mm] [mm] Øe Connections Gas F

200 188 90 450 550 1441 1463 64 316 351 401 451 511 631 701 751 801 861 1061 1111 1161 // 1176 300 300 1”1/4 1” 1” 1”1/4

300 289 109 550 650 1550 1578 123 400 435 485 535 595 715 785 835 885 945 1145 1195 1245 // 1260 300 300 1”1/4 1” 1” 1”1/4

500 497 144 650 750 1841 1873 114 416 451 501 551 611 801 926 976 1026 1086 1351 1401 1451 // 1526 300 300 1”1/4 1” 1” 1”1/4

800 789 212 750 850 2138 2174 101 433 478 568 658 718 898 978 1068 1158 1268 1518 1568 1618 // 1793 380 300 1”1/4 2” 1” 1”1/4

1000 1037 247 850 950 2192 2235 89 454 499 589 679 739 989 1049 1139 1229 1289 1549 1639 1729 // 1814 380 380 1”1/2 2” 2” 1”1/2

1500 1489 325 950 1050 2498 2540 106 493 538 628 718 778 1128 1213 1303 1393 1453 1838 1928 2018 // 2103 380 380 1”1/2 2” 2” 2”

2000 2052 478 1100 1200 2575 2630 93 535 655 760 865 935 909 1230 1335 1440 1505 1795 1885 1975 2000 2125 430 380 2” 2” 2” 2”

3000 2983 608 1250 1350 2919 2982 137 604 724 829 934 1004 1028 1424 1529 1634 1704 2139 2229 2319 2068 2444 430 380 2” 2” 2” 2”

4000 4003 836 1450 1550 2925 3010 112 642 762 867 972 1042 1047 1380 1485 1590 1662 2107 2167 2317 1967 2382 430 430 2” 2” 2” 2”

5000 4935 994 1600 1700 2959 3061 92 646 766 871 976 1046 1051 1466 1571 1676 1746 2076 2181 2286 2271 2396 430 430 2” 2” 2” 2”

21
BOL. EXTRA1 WRC VT VAP.
INSULATED POLYWARM® CALORIFIERS WITH 1 STEAM OR HOT WATER HEAT EXCHANGER

BOL. EXTRA1 WRC VT VAP.


Capacity
POLYWARM®

COPPER EXCHANGER
[liters] ART. NR. Price [€]
200 3069162350051 1.370,00
300 3069162350052 1.481,00
500 3069162350053 1.734,00
800 3069162350054 2.212,00
1000 3069162350055 2.679,00
1500 3069162350056 3.494,00
2000 3069162350057 4.013,00
3000 3069162350058 6.165,00
4000 3069162350059 7.323,00
STORAGE EXCHANGER
5000 3069162350060 8.215,00
Pmax Tmax Pmax Tmax
8 bar 90 °C 12 bar 191,6 °C

Technical descriptions Insulation Heat exchanger


The calorifiers work with the steam produced by the 50 mm soft polyurethane foam. Thermal conductivity: Copper heat exchanger suitable for drinking water in
system. They are realized in carbon steel with internal 0.038 W/mK. accordance with D.M. N° 174 dated 06.04.04. Full
Polywarm® coating, an innovative thermoplastic internal compliance with P.E.D. categories Art. 3.3, Cat I & Cat II
corrosion proofing, composed by resins suitable for External lining suitable for saturated steam.
drinkable water, according to D.M N 174 dated 16 04 04. SCAI RED RAL 3000 complete with upper trims and flange
cover. Cathode protection
Application Magnesium anode with Anoden-tester which allows
Production and storage of sanitary hot water for civil and Drain pipe to easily check which is the real consumption of the
industrial use. External confluence through jointable pipe. magnesium bar.
Capacity >1500 lt have two magnesium anode.
Corrosion-proofing Warranty Electronic anode on request (see page 71)
Internal polywarm coating suitable for drinkable water D.L. - 5 years - See general sales conditions and warranty
n. 108 del 25.01.92. Gasket-Flange Plate
Particularly suitable for solar systems - CEFLEX gum for food use max temperature 192°;
- Corrosion proofing flange cover.

P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

Data have been calculated on primary at saturated steam and production of DHW in continue way from 10° to 45°C with storage at 60°C
Even if tanks are tested to resist from Max temperature from 60°C to 90°C, local laws and regulations should always be respected during their use.

Capacity Heat Exchangers Surface Production of DHW Output Weight


PED Category
[liters] [m2] l/h l/10 mm Ignition Time [min] [KW] [Kg]

200 0,5 2209 596 6 92 68 Art. 3.3

300 0,75 3313 894 6 138 83 Art. 3.3

500 1 4418 1306 8 184 106 Cat. I

800 1,5 6627 1959 8 276 168 Cat. I

1000 2 8836 2613 8 368 191 Cat. I

1500 3 13254 3919 8 552 250 Cat. I

2000 3 13254 4489 10 552 367 Cat. I

3000 5 22090 7102 9 920 491 Cat. II

4000 5 22090 8242 12 920 663 Cat. II

5000 5 22090 9382 15 920 793 Cat. II

22
De CONNECTIONS
Df 1 Drain 3/4” Gas F (from 200 lt to 1.000 lt)
(14) 2 Domestic Cold Water Circuit Inlet
Alternative Domestic Cold Water Circuit Inlet
3

CALORIFIERS
or connection for more boilers
4 Condensate draining system
5 Exchanger flange
H17 (11)
6 Steam inlet
(12) (13)
H16 (10) 7 Connection for thermostat 1/2" Gas F
8 Connection for magnesium anode 1” 1/4 Gas F
H15 (9)
Connection to 2nd anode 1”1/4 Gas F
9
(available only on >1500 lt)
Connection for electrical immersion resistance
10
1”1/2 Gas F
Connection for recirculation or for Domestic Hot
A

11-13
water delivery
H

12 Connection for thermometer 1/2” Gas F


H7 (8)
H6 (7) 14 Domestic Hot water outlet

H4 (5) 15 Drain 1” Gas F (only for capacities >1000 lt)

H2 (2) (3)

H1 (1)
0

Tanks from 1500 to 5000 liters (Polywarm® version)


(14) H5 (6) have two gripps on the bottom which allows the use
(1) (2) (11) (3) (13)
of forklift when handling.
H3 (4)

(7) (10) (12) (8) (9)


H1 (15)

(4) (5) (6) (15)

Net 2-3
Cap. Weight Df De H A H1 H2 H3 H4 H5 H6 H7 H15 H16 H17 5 4-6 14
Volume 11-13
[liters] [Kg] [liters] [mm] [mm] [mm] Connections Gas F

200 68 188 450 550 1441 1463 64 316 351 401 451 511 751 // 1066 1176 Øe 300 DN25 PN16 1"1/4 1"1/4

300 83 289 550 650 1550 1578 123 400 435 485 535 595 835 // 1150 1260 Øe 300 DN25 PN16 1"1/4 1"1/4

500 106 497 650 750 1841 1873 114 416 451 501 551 611 976 // 1370 1526 Øe 300 DN25 PN16 1"1/4 1"1/4

800 168 789 750 850 2138 2174 101 433 478 568 658 718 1118 // 1638 1793 Øe 380 DN50 PN16 1"1/4 1"1/4

1000 191 1037 850 950 2192 2235 89 454 499 589 679 739 1139 // 1660 1814 Øe 380 DN50 PN16 1"1/2 1"1/2

1500 250 1489 950 1050 2498 2540 106 493 538 628 718 777 1302 // 1947 2102 Øe 380 DN50 PN16 1"1/2 2"

2000 367 2052 1100 1200 2575 2630 93 535 655 760 865 935 909 2000 1945 2125 Øe 430 DN50 PN16 2" 2"

3000 491 2983 1250 1350 2919 2982 137 604 724 829 934 1003 1028 2268 2285 2443 Øe 430 DN50 PN16 2" 2"

4000 663 4003 1450 1550 2925 3010 112 642 762 870 972 1042 1047 2257 2210 2382 Øe 430 DN50 PN16 2" 2"

5000 793 4935 1600 1700 2959 3061 92 646 766 871 976 1046 1051 2271 2241 2396 Øe 430 DN50 PN16 2" 2"

23
BOL. EXTRA1 WRC VT PLUS
INSULATED POLYWARM® CALORIFIERS WITH 1 EXTRACTABLE FINNED HEAT EXCHANGER

BOL. EXTRA1 WRC VT PLUS


Capacity
COPPER EXCHANGER
[liters] ART. NR. Price [€]
POLYWARM®

200 3072162352002 968,00


300 3072162352003 1.104,00
500 3072162352004 1.344,00
800 3072162352005 1.852,00
1000 3072162352006 2.029,00
1500 3072162352007 2.909,00
2000 3072162352008 3.590,00

PROMPT DELIVERY
Grey highlighted products are
STORAGE EXCHANGER dispatched in 1-5 working days.
Pmax Tmax Pmax Tmax (Delivery time excluded)
8 bar 90° C 12 bar 99° C

BOL. EXTRA2 WRC VT PLUS


INSULATED POLYWARM® CALORIFIERS WITH 2 EXTRACTABLE FINNED HEAT EXCHANGERS

BOL. EXTRA2 WRC VT PLUS


Capacity
COPPER EXCHANGER
[liters] ART. NR. Price [€]
POLYWARM®

200 3082162352001 1.358,00


300 3082162352002 1.447,00
500 3082162352003 1.752,00
800 3082162352004 2.298,00
1000 3082162352005 2.609,00
1500 3082162352006 3.612,00
2000 3082162352007 4.483,00
3000 3082162352009 5.682,00
4000 3082162352010 7.280,00
I
SISTEM LARI
Product component of a complete Sun un TERM
ICI SO 5000 3082162352012 8.553,00
STORAGE EXCHANGER
Solution Solar Thermal System PROMPT DELIVERY
Pmax Tmax Pmax Tmax Please refer Sun Solution Cordivari 201
0
Grey highlighted products are
8 bar
INO ue
ermiq
LIST
90° C 12 bar 99° C catalogue CAT
ALO
èmes
Th GO

dispatched in 1-5 working days.


(Delivery time excluded)

BOL. EXTRA3 WRC VT PLUS


INSULATED POLYWARM® CALORIFIERS WITH 3 EXTRACTABLE FINNED HEAT EXCHANGERS

BOL. EXTRA3 WRC VT PLUS


Capacity
COPPER EXCHANGER
[liters] ART. NR. Price [€]
POLYWARM®

200 3092162352001 1.749,00


300 3092162352002 1.829,00
500 3092162352003 2.113,00
800 3092162352004 2.856,00
1000 3092162352005 3.196,00
1500 3092162352006 4.041,00
2000 3092162352007 5.390,00
3000 3092162352009 6.746,00
4000 3092162352010 8.431,00
STORAGE EXCHANGER 5000 3092162352012 9.699,00

Pmax Tmax Pmax Tmax


8 bar 90° C 12 bar 99° C

Technical descriptions Insulation Heat exchanger:


The heat exchange is ensured by the innovative double 50 mm soft polyurethane foam. Thermal conductivity: Double spirals copper finned tubes, suitable for drinking
spiral copper finned tubes exchanger. 0.038 W/mK. water according to D.M N 174 dated 16 04 04.
These calorifiers, thanks to this high performance
Exchanger working with low temperature Primary Circuit, External lining Cathode protection
are particularly suitable for forced circulation Solar SCAI RED RAL 3000 complete with upper trims and flange Magnesium anode with Anoden-tester which allows to
System. They are realized in carbon steel with internal cover. check easily the real consumption of the magnesium bar.
Polywarm® coating suitable for drinking water according For capacity > 1500lt n°2 magnesium anode.
Electronic anode on request (see page 71)
to D.M N 174 dated 16 04 04. Drain pipe
External confluence through jointable pipe. Gasket-Flange Plate
Application
Production and Storage of sanitary hot water for domestic Warranty - Silicone gaskets suitable for alimentary use for max
and industrial uses. - 5 years (Polywarm®) temperature up to 200° C. (D.M. n.174 dated 2004);
See general sales conditions and warranty - Corrosion proofing flange cover.

24
Thermal power data are referred to ∆t=50 (as a difference between the inlet temperature of Primary circuit and inlet temperature of the Secondary one).

FOR DIMENSIONAL DATA PLEASE SEE EXTRA 1 TABLE AT PAGE 15


De
EXCHANGER 1 Output Df
Capacity Df De H A
Diameter Surface ∆t=50°C (14)

[liters] [mm] [m2] [Kw]


200 450 550 1441 1463 ø e 300 0,76 15 H17 (11)

CALORIFIERS
(12) (13)
300 550 650 1550 1578 ø e 300 0,94 19 H16 (10)
H15 (9)
500 650 750 1841 1873 ø e 300 1,58 24 ANODEN TESTER

800 750 850 2138 2174 ø e 380 2,63 29

A
1000

H
850 950 2192 2235 ø e 380 3,17 35
H7 (8)
1500 950 1050 2498 2540 ø e 380 4,54 50 H6 (7)
H4 (5)
2000 1100 1200 2575 2630 ø e 430 5,26 56
H2 (2) (3)

H1 (1)
0

FOR DIMENSIONAL DATA PLEASE SEE EXTRA 2 TABLE AT PAGE 17


De
EXCHANGER 1 EXCHANGER 2 Total Output Df
Capacity Df De H A
Diameter Surface Diameter Surface Surface ∆t=50°C (18)

[liters] [mm] [m2] [mm] [m2] [m2] [Kw]


200 450 550 1441 1463 ø e 300 0,76 ø e 300 0,76 1,52 30 H17 (15)
(16) (17)
300 550 650 1550 1578 ø e 300 0,94 ø e 300 0,76 1,7 34 H16 (14)
H15 (13)
500 650 750 1841 1873 ø e 300 1,58 ø e 300 0,76 2,34 39
800 750 850 2138 2174 ø e 380 2,63 ø e 380 0,94 3,57 48 H11 (12) ANODEN TESTER

A
1000 850 950 2192 2235 ø e 380 3,17 ø e 380 1,58 4,75 59 H9 (10)

H
1500 950 1050 2498 2540 ø e 380 4,54 ø e 380 2,27 6,81 77 H7 (8)

2000 1100 1200 2575 2630 ø e 430 5,26 ø e 430 3,17 8,43 91 H6 (7)
H4 (5)
3000 1250 1350 2919 2982 ø e 430 5,26 ø e 430 4,54 9,8 106
H2 (2) (3)
4000 1450 1550 2925 3010 ø e 430 5,26 ø e 430 5,26 10,52 112
5000 1600 1700 2959 3061 ø e 430 6,34 ø e 430 6,34 12,68 140
H1 (1)
0

FOR DIMENSIONAL DATA PLEASE SEE EXTRA 3 TABLE AT PAGE 21


De
EXCHANGER 1 EXCHANGER 2 EXCHANGER 3 Total Output Df
Capacity Df De H A
Diameter Surface Diameter Surface Diameter Surface Surface ∆t=50°C (21)

[liters] [mm] [m2] [mm] [m2] [mm] [m2] [m2] [Kw]


200 450 550 1441 1463 ø e 300 0,76 ø e 300 0,76 ø e 300 0,76 2,28 45 H17 (15)
(16) (17) (18)

300 550 650 1550 1578 ø e 300 0,94 ø e 300 0,76 ø e 300 0,76 2,46 49 H13 (14)
H15 (13)

500 650 750 1841 1873 ø e 300 1,58 ø e 300 0,76 ø e 300 0,76 3,10 54
H11 (12)
800 750 850 2138 2174 ø e 380 2,63 ø e 300 0,94 ø e 300 0,76 4,33 63 ANODEN TESTER
A

1000 850 950 2192 2235 ø e 380 3,17 ø e 380 1,58 ø e 380 0,94 5,69 78 H9 (10)
H

H7 (8)
1500 950 1050 2498 2540 ø e 380 4,54 ø e 380 2,27 ø e 380 1,58 8,39 101
H6 (7)
2000 1100 1200 2575 2630 ø e 430 5,26 ø e 380 4,54 ø e 430 2,63 12,43 120
H4 (5)
3000 1250 1350 2919 2982 ø e 430 5,26 ø e 380 4,54 ø e 430 3,17 12,97 141
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

H2 (2) (3)

4000 1450 1550 2925 3010 ø e 430 5,26 ø e 430 5,26 ø e 430 4,54 15,06 162
5000 1600 1700 2959 3061 ø e 430 6,34 ø e 430 6,34 ø e 430 5,26 17,94 196 H1 (1)
0

Tanks from 1500 to 5000 liters have two


gripps on the bottom which allows the use of
forklift when handling.

25
BOL. EXTRA HP
INSULATED POLYWARM® CALORIFIERS WITH 1 EXTRACTABLE FINNED HEAT EXCHANGER (IDEAL FOR HEAT PUMPS)

Capacity BOL. EXTRA HP Weight

[liters] ART. NR. Price [€] [Kg]


POLYWARM®

300 3072162370001 1.578,00 73


500 3072162370002 2.078,00 103
STORAGE EXCHANGER
800 3072162370003 2.599,00 155
Pmax Tmax Pmax Tmax
1000 3072162370004 2.865,00 175
8 bar 90° C 12 bar 99° C

Technical descriptions External lining Heat exchanger:


The heat exchange is ensured by the innovative double SCAI RED RAL 3000 complete with upper trims and flange Double spirals copper finned tubes, suitable for drinking
spiral copper finned tubes exchanger with an high cover. water according to D.M N 174 dated 16 04 04.
exchanging surface relating to the calorifiers volume.
These calorifiers are realized in carbon steel with internal Drain pipe Cathode protection
Polywarm® coating suitable for drinking water according External confluence through jointable pipe. Magnesium anode with Anoden-tester which allows to
to D.M N 174 dated 16 04 04. check easily the real consumption of the magnesium bar.
For capacity > 1500lt n°2 magnesium anode.
Warranty Electronic anode on request (see page 71)
Application - 5 years (Polywarm®)
Production and Storage of sanitary hot water for domestic See general sales conditions and warranty
and industrial uses. Gasket-Flange Plate
- Silicone gaskets suitable for alimentary use for max
Insulation temperature up to 200° C. (D.M. n.174 dated 2004);
50 mm soft polyurethane foam. Thermal conductivity: - Corrosion proofing flange cover.
0.038 W/mK.

THERMAL INFORMATION REFERRED TO INLET PRIMARY TEMPERATURE 65° C


Continous Storage DHW produced in the DHW produced in the Exchanger pressure
Capacity Heat exchangers surface Ignition Time Output Flow rate
production of DHW volume first 10 Min. first hour. loss
[liters] [m2] [min] [Kw] [liters/h] [liters] [liters] [liters] [m3/h] [mm.c.a.] [mbar]
300 3,06 22 42 1032 285 457 1317 2 1186 116
500 5,26 23 71 1745 480 771 2225 2,5 3186 313
800 7 30 87 2138 740 1096 2878 3 5530 542
1000 7 38 87 2138 995 1351 3133 3 5530 542
Datas have been calculated on following basis:
1) Primary circuit at 65°C and proper energy source;
2) Production of DHW in continue way from 10 to 45°C;
3) DHW that can be taken in the fist 10’ and in the first hour from storage at 45° C, input 10°C and output 45°C;
4) Sanitary water not scaling.

THERMAL INFORMATION REFERRED TO INLET PRIMARY TEMPERATURE 55° C


Continous Storage DHW produced in the DHW produced in the Exchanger pressure
Capacity Heat exchangers surface Ignition Time Output Flow rate
production of DHW volume first 10 Min. first hour. loss
[liters] [m2] [min] [Kw] [liters/h] [liters] [liters] [liters] [m3/h] [mm.c.a.] [mbar]
300 3,06 37 26 639 285 391 924 2 1186 116
500 5,26 38 45 1106 480 664 1586 2,5 3186 313
800 7 43 54 1327 740 961 2067 3 5530 542
1000 7 64 54 1327 995 1216 2322 3 5530 542
Datas have been calculated on following basis:
1) Primary circuit at 55°C and proper energy source;
2) Production of DHW in continue way from 10 to 45°C;
3) DHW that can be taken in the fist 10’ and in the first hour from storage at 45° C, input 10°C and output 45°C;
4) Sanitary water not scaling.

26
CONNECTIONS
De 1 Drain 3/4" Gas F

CALORIFIERS
2 Domestic Cold Water Circuit Inlet
Df
Alternative Domestic Cold Water Circuit Inlet
H10 (13) 3
or connection for more boilers
4 Primary circuit oulet 1"1/4 Gas M
5 Exchanger flange
6 Primary circuit inlet 1"1/4 Gas M
H7 (10) 7 Connection for thermostat 1/2" Gas F
(11) (12) Connection for electrical immersion resistance 1”1/2
8
Gas F
9 Connection for magnesium anode 1” 1/4 Gas F
Connection for recirculation or for Domestic Hot water
10-12
delivery
A

H6 (9) 11 Connection for thermometer 1/2" Gas F


H5 (8) 13 Domestic Hot water outlet
H

H4 (7)
H3 (4) (6)
(5) (6) (4)
(1) (13) (3)
H2 (2) (3)
(2) (10) (12)

H1 (1)
(7) (11) (9)
0
(4) (5) (6) (8)

Capacity Heat exchangers surface Df De H A H1 H2 H3 H4 H5 H6 H7

[liters] [m2] [mm]


300 3,06 550 650 1550 1575 123 400 485 595 835 885 1260
500 5,26 650 750 1841 1868 114 416 551 701 901 976 1526
800 7 750 850 2138 2169 101 433 568 718 918 1118 1793
1000 7 850 950 2192 2229 89 454 589 739 939 1139 1814

EXTRA HP CALORIFIER IDEAL FOR HEAT PUMP


LEGEND
A Sanitary cold water inlet
B Sanitary hot water users
C Heating system
3
B D Recirculation
E Drain
1 Extra HP water heater
2 Heat pump
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

1 3 Thermostatic mixer
4 Hydraulic safety group
ANODEN TESTER

D 5 Expanding vase
6 Circulator
6 7 Mixing system
Connection for electrical integration 1"1/2
8
Gas F

8 6 6
7

C
A
4
5
E 2

27
BOL. EXTRA1 XXC OR
HORIZONTAL INSULATED STAINLESS STEEL 316L CALORIFIERS WITH 1 EXTRACTABLE HEAT EXCHANGER (AVAILABLE ON REQUEST)

STAINLESS STEEL 316L BOL. EXTRA1 XXC OR Exchanger


Capacity Price
STAINLESS STEEL 316L EXCHANGER Surface
[liters] ART. NR. [€] [m2]
200 3072051400002 on request 0,5
300 3072051400003 on request 0,75
500 3072051400004 on request 1
1000 3072051400006 on request 2
1500 3072051400007 on request 3
2000 3072051400008 on request 4
3000 3072051400010 on request 5
4000 3072051400011 on request 8
5000 3072051400013 on request 10
STORAGE EXCHANGER
Datas have been calculated with primary circuit at 80°C, production of DHW in continue way
Pmax Tmax Pmax Tmax
from 10 to 45°C with storage at 60 °C and insulation of 50 mm.
8 bar 95° C 12 bar 99° C

BOL. EXTRA1 WRC/WXC OR


HORIZONTAL INSULATED POLYWARM® CALORIFIERS WITH 1 EXTRACTABLE HEAT EXCHANGER
POLYWARM®

BOL. EXTRA1 WRC OR BOL. EXTRA1 WXC OR Exchanger


Capacity
COPPER EXCHANGER STAINLESS STEEL 316L EXCHANGER Surface
[liters] ART. NR. Price [€] ART. NR. Price [€] [m2]
200 3072161420001 1.130,00 3072161430001 1.209,00 0,5
300 3072161420002 1.328,00 3072161430002 1.426,00 0,75
500 3072161420003 1.670,00 3072161430003 1.759,00 1
800 3072161420004 2.045,00 3072161430004 2.274,00 1,5
1000 3072161420005 2.387,00 3072161430005 2.703,00 2
STORAGE EXCHANGER 1500 3072161420006 3.124,00 3072161430006 3.562,00 3
Pmax Tmax Pmax Tmax 2000 3072161420007 4.062,00 3072161430007 4.454,00 4
8 bar 90° C 12 bar 99° C 3000 3072161420008 5.116,00 3072161430008 5.623,00 5
4000 3072161420009 6.814,00 3072161430009 7.538,00 8
5000 3072161420011 8.166,00 3072161430011 8.658,00 10
Datas have been calculated with primary circuit at 80°C, production of DHW in continue way from 10 to
45°C with storage at 60 °C and insulation of 50 mm.

Datas have been calculated on following basis:


1) Primary circuit at 80°C and proper energy source;
2) Production of DHW in continue way from 10 to 45°C.
3) DHW that can be taken in the fist 10’ and in the first hour from storage at 60°C, input 10°C and output 45°C;
4) Sanitary water not scaling.
Even if tanks are tested to resist from Max temperature 60°C to 95°C, the local legislation has always to be observed during the use.
Continous Storage DHW produced in the first DHW produced
Capacity Ignition Time Output Flow rate Exchanger pressure loss
production of DHW volume 10 Min. in the first hour
3
[liters] [min] [Kw] [lt/h] [lt] [lt/10’] [lt/60’] [m /h] [mm.c.a.] [mbar]
200 49 18 455 190 347 635 2 309 30,3
300 48 28 701 285 524 968 3 372 36,5
500 60 38 947 480 844 1443 4 419 41,1
(*) 800 59 59 1466 740 1301 2230 6 718 70,4
1000 54 86 2127 995 1776 3123 10 1380 135,3
1500 53 133 3290 1490 2677 4761 15 2295 225,1
2000 52 180 4453 1975 3564 6384 20 2996 293,8
3000 65 216 5361 2975 5144 8539 20 2436 238,9
4000 57 330 8168 3890 6918 12092 20 3896 382,1
5000 60 401 9921 4890 8639 14923 20 4707 461,6
(*) Versione Inox non disponibile

28
CONNECTIONS
1 Primary Circuit Outlet
2 Primary Circuit Inlet
3 Connection for magnesium anode

CALORIFIERS
4-5 Connection for instrumentation 1/2" Gas F
6-7 Domestic Hot water outlet
8 Connection for recirculation
9 - 10 Domestic Cold Water Circuit Inlet
Connection to 2nd anode 1”1/4 Gas F
11
(available only on >1500 lt)
12 Air Ventil Heat Exchanger 3/8" Gas F

ANODEN TESTER

0 L1 L5 L2
(9) (7) (11) (10) (6) 200
(11)

(4) (5) H6(4)(5)


45°

(3)
De

(8) H5 (3)
(12)

H
(2) H4 (2)
H3
(1) H2 (1)

H1 (9) (10)
0
L3 L L4 I

Technical descriptions Insulation Heat exchanger:


Cordivari offers two types of coating/material suitable for 50 mm soft polyurethane foam. Thermal conductivity: Legionellosis prophylaxis coil
drinking water according to D.M N 174 dated 16 04 04 0.038 W/mK. Stainless Steel 316L or Copper Curved Pipe, suitable for
drinking water according to D.M N 174 dated 16 04 04.
for horizontal Extra1 Sanitary Hot Water Heaters with 1
External lining
extractable Heat Exchanger: SCAI red Ral 3000. Cathode protection
- Stainless Steel 316L for the whole tank (available on Magnesium anode with Anoden-tester which allows to
request) Drain pipe check easily the real consumption of the magnesium bar.
For capacity > 1500lt n°2 magnesium anode.
- Carbon steel with internal Polywarm® coating External confluence through jointable pipe Electronic anode on request (see page 71)
Application Warranty Gasket-Flange Plate
Production and Storage of sanitary hot water for domestic - 5 years (Stainless Steel 316L / Polywarm®)
and industrial uses. - Silicone gaskets suitable for alimentary use for max
See general sales conditions and warranty
temperature up to 200° C. (D.M. n.174 dated 2004);
- Corrosion proofing flange cover.
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

Capacity De L H L1 L2 L3 L4 L5 H1 H2 H3 H4 H5 H6 I 1-2 4-5 3-8 6-7-9-10 11

[liters] [mm] Connections Gas F


200 450 1534 601 294 1094 359 1029 - 41 191 241 291 446 446 364 1" 1/2'' 1''1/4 1''1/4 -
300 550 1585 760 320 1120 390 1050 - 100 287 337 387 555 619 419 1" 1/2'' 1''1/4 1''1/4 -
500 650 1874 855 345 1395 440 1300 - 95 332 382 432 600 664 477 1" 1/2'' 1''1/4 1''1/4 -
800 750 2191 951 375 1675 505 1545 - 91 297 387 477 666 766 577 2'' 1/2'' 1''1/4 1''1/2 -
1000 850 2201 1046 408 1708 538 1578 - 86 226 316 406 561 866 636 2'' 1/2'' 1''1/2 1''1/2 -
1500 950 2571 1142 424 1974 579 1819 - 72 247 337 427 597 952 760 2'' 1/2'' 2'' 2'' -
2000 1100 2626 1283 470 2020 610 1880 858 63 263 368 473 663 1018 849 2'' 1/2'' 2'' 2'' 1''1/4
3000 1250 2956 1524 495 2295 695 2095 945 154 324 429 534 829 1184 981 2'' 1/2'' 2'' 2'' 1''1/4
4000 1450 3066 1707 560 2360 665 2255 1010 137 307 412 517 912 1267 1101 2'' 1/2'' 2'' 3'' 1''1/4
5000 1600 3107 1845 583 2383 783 2183 1033 125 305 410 515 975 1330 1189 2'' 1/2'' 2'' 3'' 1''1/4

29
PIASTRATERM®
INSULATED POLYWARM® CALORIFIERS WITH PLATE HEAT EXCHANGER

1 PIASTRATERM® INCLUDES:
1
POLYWARM®

Sanitary water storage tank (from 200 to 2000 lt)


2
5
Plate exchanger (PHC) from 9 to 33 plates in stainless steel AISI
2 316L
3
Technical features:
• Easy operation on the heat exchanger.
• High efficiency thermal exchange.
• Easy installation.
4 • Several possibilities to change the proportion between the
storage’s volume and the power of the exchanger.

STORAGE EXCHANGER PHC D.H.W. HARDNESS


3 Circulation pump suitable for sanitary hot water
Pmax Tmax Pmax Tmax F max
8 bar 90° C 12 bar 99° C 30°F
4 Piping and connections

ON REQUEST:
5 "EASY CONTROL” Electronic Display

Technical descriptions
The Piastraterm calorifiers are used for the production and External lining Gasket-Flange Plate
storage of domestic hot water (DHW) and have the inside coating Red SCAI Ral 3000 complete with black top and flange cover. - Silicone gaskets suitable for alimentary use for max temperature
in Polywarm that is suitable for drinkable water according to D.M up to 200° C. (D.M. n.174 dated 2004);
N 174 dated 16 04 04. Circulation pump for sanitary hot water Drain
particularly resistant to limestone. External confluence through jointable pipe. - Polywarm® coated flange cover.

Application Cathode protection Warranty


Production and Storage of sanitary hot water for domestic and Magnesium anode with Anoden-tester which allows to check 5 years (Polywarm®)
industrial uses. easily the real consumption of the magnesium bar. See general sales conditions and warranty
Heat exchanger
Insulation Plate-to-plate Stainless Steel Aisi 316L exchanger with insulated
50 mm soft polyurethane foam. Thermal conductivity: 0.038 W/ casing rated between 43 Kw and 244 Kw.
mK.

Datas have been calculated on following basis:


1) Primary circuit at 80°C;
2) Production of DHW in continue way from 10 to 45°C.
Capacity NUMBER OF PLATE EXCHANGER PHC 3120
[liters] ART. NR.

9 13 17 21 25 29 33
200 3170161701001 3170161701002 3170161701003 3170161701004 3170161701005 -- --
€ 2.422,00 € 2.494,00 € 2.556,00 € 2.618,00 € 2.679,00 -- --
9 13 17 21 25 -- --
300 3170161701011 3170161701012 3170161701013 3170161701014 3170161701015 -- --
€ 2.543,00 € 2.615,00 € 2.667,00 € 2.759,00 € 2.800,00 -- --
9 13 17 21 25 29 33
500 3170161701021 3170161701022 3170161701023 3170161701024 3170161701025 3170161701026 3170161701027
€ 2.687,00 € 2.760,00 € 2.821,00 € 2.884,00 € 2.946,00 € 3.007,00 € 3.078,00

9 13 17 21 25 29 33
800 3170161701031 3170161701032 3170161701033 3170161701034 3170161701035 3170161701036 3170161701037
€ 3.014,00 € 3.087,00 € 3.148,00 € 3.252,00 € 3.305,00 € 3.400,00 € 3.497,00

9 13 17 21 25 29 33
1000 3170161701041 3170161701042 3170161701043 3170161701044 3170161701045 3170161701046 3170161701047
€ 3.317,00 € 3.390,00 € 3.451,00 € 3.513,00 € 3.575,00 € 3.637,00 € 3.699,00

-- -- 17 21 25 29 33
1500 -- -- 3170161701053 3170161701054 3170161701055 3170161701056 3170161701057
-- -- € 4.085,00 € 4.148,00 € 4.210,00 € 4.274,00 € 4.337,00

-- -- 17 21 25 29 33
2000 -- -- 3170161701063 3170161701064 3170161701065 3170161701066 3170161701067
-- -- € 4.535,00 € 4.646,00 € 4.711,00 € 4.822,00 € 4.888,00

Output [Kw] 43 76 109 143 176 210 244


D.H.W. [lt/h] 1054 1862 2671 3504 4312 5145 5978

30
CONNECTIONS
De 1 Drain 3/4” Gas F (from 200 lt to 1000 lt)
Df 2 Domestic Cold Water Circuit Inlet
Alternative Domestic Cold Water Circuit Inlet

CALORIFIERS
(14) 3
or connection for more boilers
5 Blind flange for inspection
7 Connection for thermostat 1/2" Gas F

H10 (11) (12) (13) 8 Connection for magnesium anode 1” 1/4 Gas F

Connection to 2nd anode 1”1/4 Gas F


H9 (10) 9
H11 (16) (available only on >1500 lt)
H8 (9) 10 Connection for electrical immersion resistance 1”1/2 Gas F
11 Primary circuit inlet
12 Connection for thermometer 1/2" Gas
H

13 Connection for recirculation


H7 (8) 14 Domestic Hot water outlet

H6 (7) 15 Drain 1” Gas F (only for capacities >1000 lt)


16 Primary circuit outlet
H4 (5)
On request:
H2 (2) (3) "EASY CONTROL” Electronic Display mounted
and connected.
Available as accessories - Euro 408,00 – see
page 70
H1 (1)
0

Tanks from 1500 to 5000 liters (Polywarm® version)


have two gripps on the bottom which allows the use
(1) (2) (14) of forklift when handling.
(11) (16) (3) (13)

(7) (10) (12) (8) (9)


H1 (15)
(5) (15)
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

Net 2-3
Capacity Df De H H1 H2 H4 H6 H7 H8 H9 H10 H11 5 14
Volume 11-13
[liters] [liters] [mm] Connections Gas F

200 188 450 550 1441 64 316 401 511 751 // 1066 1176 945 Øe 300 1"1/4 1"1/4

300 289 550 650 1550 123 400 485 595 835 // 1150 1260 1029 Øe 300 1"1/4 1"1/4

500 497 650 750 1841 114 416 501 611 976 // 1370 1526 1295 Øe 300 1"1/4 1"1/4

800 789 750 850 2138 101 433 568 718 1118 // 1638 1793 1562 Øe 380 1"1/4 1"1/4

1000 1037 850 950 2192 89 454 589 739 1139 // 1660 1814 1583 Øe 380 1"1/2 1"1/2

1500 1489 950 1050 2498 107 493 628 778 1303 // 1947 2103 1872 Øe 380 1"1/2 2"

2000 2052 1100 1200 2575 94 535 760 935 909 2000 1945 2125 1894 Øe 430 2" 2"

31
VASO INERZ. XC VT
INSULATED STAINLESS STEEL 316L D.H.W. ACCUMULATION TANK

STAINLESS STEEL 316L


Capacity VASO INERZ. XC VT Weight

[liters] ART. NR. Price [€] [Kg]


200 3060052140002 1.761,00 49
300 3060052140003 1.976,00 62
500 3060052140004 2.540,00 85
1000 3060052140006 4.151,00 155
1500 3060052140007 6.773,00 213
2000 3060052140008 9.382,00 258
3000 3060052140009 on request 346
4000 3060052140010 on request 528
5000 3060052140011 on request 665

Pmax Tmax
8 bar 95° C

VASO INERZ. WC VT
INSULATED POLYWARM® D.H.W. ACCUMULATION TANK

Capacity VASO INERZ. WC VT Weight


POLYWARM®

[liters] ART. NR. Price [€] [Kg]


200 3060161620002 719,00 49
300 3060161620003 812,00 62
500 3060161620004 964,00 85
800 3060161620005 1.268,00 118
1000 3060161620006 1.445,00 155
1500 3060161620007 2.155,00 213
2000 3060161620008 2.705,00 258
3000 3060161620009 3.446,00 346
4000 3060161620010 4.497,00 528
5000 3060161620011 5.280,00 665
Pmax Tmax
8 bar 90° C PROMPT DELIVERY
Grey highlighted products are
dispatched in 1-5 working days.
(Delivery time excluded)

32
De
Df
(14) CONNECTIONS
1 Drain 3/4” Gas F (from 200 to 1000 lt)
2 Domestic Cold Water Circuit Inlet

3 Delivery to external heat exchanger

CALORIFIERS
H17 (11) (12) (13)
5 Blind flange for inspection
H16 (10)
7 Connection for thermostat 1/2" Gas F
H15 (9)
8 Connection for magnesium anode 1” 1/4 Gas F
ANODEN TESTER
Connection to 2nd anode 1”1/4 Gas F
9
(available only on >1500 lt)
10 Connection for electrical immersion resistance 1”1/2 Gas F
11 Connection for recirculation
12 Connection for 1/2" Gas thermometer
H7 (8)
H6 (7) 13 Backflow external heat exchanger
14 Domestic Hot water outlet
H4 (5) 15 Drain 1” Gas F (only for capacities >1000 lt)

On request:
H2 (2) (3) "EASY CONTROL” Electronic Display mounted
and connected.
Available as accessories - Euro 408,00 – see
page 70
H1 (1)
0

(14)
(1) (2) (11) (3) (13)
Tanks from 1500 to 5000 liters (Polywarm® version)
have two gripps on the bottom which allows the use of
forklift when handling.

(7) (10) (12) (8) (9) H1 (15)

(5) (15)

Technical descriptions External lining Cathode protection


Cordivari offers two types of coating/material suitable for Red SCAI Ral 3000 complete with top and flange cover. Magnesium anode Anoden Tester which allows to check
drinking water according to D.M. N° 174 dated 16/04/04 easily the real consumption of the magnesium bar. For
for Accumulation Tanks: Drain capacity > 1500lt n°2 magnesium anode.
Drain outside thanks to a connected pipe. Electronic anode on request only for Polywarm® version
- Stainless Steel 316L (see page 71)
- Carbon steel with internal Polywarm® coating Gasket-Flange Plate
Warranty
Application Silicone gaskets suitable for alimentary use for max - 5 years (Stainless Steel 316L)
Storage of sanitary hot water for domestic and industrial temperature up to 200° C. (D.M. n.174 dated 2004); - 5 years (Polywarm®)
uses. • XC VT : stainless steel 316L flange cover See general sales conditions and warranty.
• WC VT : Polywarm® coated flange cover
Insulation
50 mm soft polyurethane foam. Thermal conductivity:
0.038 W/mK.
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

Net 2-3
Capacity Df De H A H1 H2 H4 H6 H7 H15 H16 H17 5 14
Volume 11-13
[liters] [liters] [mm] Connections Gas F

200 188 450 550 1441 1463 64 316 401 511 751 // 1066 1176 Øe 300 1"1/4 1"1/4
300 289 550 650 1550 1578 123 400 485 595 835 // 1150 1260 Øe 300 1"1/4 1"1/4
500 497 650 750 1841 1873 114 416 501 611 976 // 1370 1526 Øe 300 1"1/4 1"1/4
800 789 750 850 2138 2174 101 433 568 718 1118 // 1638 1793 Øe 380 1"1/4 1"1/4
1000 1037 850 950 2192 2235 89 454 589 739 1139 // 1660 1814 Øe 380 1"1/2 1"1/2
1500 1489 950 1050 2497 2540 106 492 627 777 1302 // 1947 2102 Øe 380 1"1/2 2"
2000 2052 1100 1200 2574 2630 93 535 760 935 909 2000 1945 2125 Øe 430 2" 2"
3000 2982 1250 1350 2917 2982 137 603 828 1003 1028 2268 2285 2443 Øe 430 2" 2"
4000 4003 1450 1550 2922 3010 112 642 867 1042 1047 2257 2210 2382 Øe 430 2" 2"
5000 4934 1600 1700 2959 3061 92 646 871 1046 1051 2271 2241 2396 Øe 430 2" 2"

33
BOL. BOLLY1 XSB/XSC VT
STAINLESS STEEL 316L CALORIFIERS WITH SINGLE FIXED COIL AND HARD FOAM INSULATION

STAINLESS STEEL 316L Capacity BOL. BOLLY1 XSB VT


Heat exchangers
Output Ignition timing DHW Production Weight
surface
80/10-45 80/10-45 80/10-60 80/10-45 80/60-10-45
[liters] ART. NR. Price [€] [m2] [Kg]
[KW] [min] [min] [lt/h] [lt/10’]

150 3105052010001 1.751,00 1 26,5 14,9 27,3 651 280 64

200 3105052010002 1.903,00 1,4 36,7 14,4 26,3 904 379 73

300 3105052010003 2.534,00 1,7 43,9 18,0 32,9 1083 523 94

500 3105052010005 3.505,00 2,6 66,9 20,0 36,0 1653 847 160

Heat exchangers
Capacity BOL. BOLLY1 XSC VT Output Ignition timing DHW Production Weight
surface
80/10-45 80/10-45 80/10-60 80/10-45 80/60-10-45
[liters] ART. NR. Price [€] [m2] [Kg]
[KW] [min] [min] [lt/h] [lt/10’]
STORAGE EXCHANGER
(*) 800 3103052010006 4.898,00 3 75,0 34,0 48,0 1842 1221 161
Pmax Tmax Pmax Tmax
10 bar 95° C 12 bar 99° C (*) 1000 3103052010007 5.570,00 3,5 87,5 38,0 52,4 2150 1501 205
8 bar - 1000 lt -
Datas have been calculated on following basis: primary hot water at 80°, DHW from 10° to 45° and storage at 60°
(*) on 800 and 1000 Lt polyurethane soft foam insulation.

BOL. BOLLY1 WSB/WSC VT


POLYWARM® CALORIFIERS WITH SINGLE FIXED COIL AND HARD FOAM INSULATION
Heat exchangers
Capacity BOL. BOLLY1 WSB VT Output Ignition timing DHW Production Weight
surface
80/10-45 80/10-45 80/10-60 80/10-45 80/60-10-45
[liters] ART. NR. Price [€] [m2] [Kg]
[KW] [min] [min] [lt/h] [lt/10’]
POLYWARM®

150 3105162320001 729,00 1 26,5 14,9 27,3 651 280 64

200 3105162320002 812,00 1,4 36,7 14,4 26,3 904 379 73

300 3105162320003 947,00 1,7 43,9 18,0 32,9 1083 523 94

400 3105162320004 1.205,00 1,9 50,9 20,7 37,8 1256 666 139

500 3105162320005 1.253,00 2,6 66,9 20,0 36,0 1653 847 160

Heat exchangers
Capacity BOL. BOLLY1 WSC VT Output Ignition timing DHW Production Weight
surface
80/10-45 80/10-45 80/10-60 80/10-45 80/60-10-45
[liters] ART. NR. Price [€] [m2] [Kg]
[KW] [min] [min] [lt/h] [lt/10’]
STORAGE EXCHANGER
(*) 800 3103162320006 2.004,00 3 75,0 34,0 48,0 1842 1221 161
Pmax Tmax Pmax Tmax
10 bar 90° C 12 bar 99° C (*) 1000 3103162320007 2.233,00 3,5 87,5 38,0 52,4 2150 1501 205
8 bar - 1000 lt -
Datas have been calculated on following basis: hot water at 80°, DHW from 10° to 45° and storage at 60°
(*) on 800 and 1000 Lt polyurethane soft foam insulation.

I
PROMPT DELIVERY
SISTEM LARI
Product component of a complete Sun un TERM
ICI SO Grey highlighted products are
Solution Solar Thermal System dispatched in 1-5 working days.
Please refer Sun Solution Cordivari (Delivery time excluded)
0
201
LIST mique
INO

catalogue CAT
ALO
tèmes
GO Ther

For graphics and exchanger pressure loss data see page 92

3/4” 3/4”

3/4” ADDITIONAL FINNED COIL 3/4” ADDITIONAL FINNED COIL.


WITH FLANGE PLATE AND GASKET.

ART. NR. DESCRIPTION Price [€] ART. NR. DESCRIPTION Price [€]
Additional finned coil for BOLLY Polywarm® Additional copper finned coil
5221000910001 333,00 5205000060002 270,00
Surface=0,94m2 - Diam.=145 mm - L=370 mm Surface=0,94m2 - Diam.=145 mm - L=370 mm
AVAILABLE FOR CAPACITY OVER LT. 300, ONLY.
Additional finned coil for BOLLY Inox
5221000010001 366,00
Surface=0,94m2 - Diam.=145 mm - L=370 mm
AVAILABLE FOR CAPACITY OVER LT. 300, ONLY.

34
CONNECTIONS
1 Drain 3/4” Gas F
2 Primary circuit outlet
3 Connection for thermostat 1/2" Gas F

CALORIFIERS
4 Blind flange for inspection
5 Domestic Cold Water Circuit Inlet
6 Connection for thermostat 1/2" Gas F
De
7 Primary circuit inlet
Df
8 Connection for magnesium anode 1” 1/4 Gas F
9 Connection for recirculation
(13) 10 Connection for Instrumentation 1/2" Gas F
11 Connection for electrical immersion resistance 1”1/2 Gas F
12 Connection for thermometer 1/2" Gas
13 Domestic Hot water outlet
H11 (12)
On request:
"EASY CONTROL” Electronic Display mounted
H10 (11) and connected.
Available as accessories - Euro 408,00 – see
H8 (9) H9 (10) page 70
H7 (8)
H6 (7)

H5 (6) (5)

(13)
H3 (3) (4) (2) (7) (9) (1) (4) (8) (11)
H2 (2)
H4 (5)

H1 (1) (3) (6) (10) (12)


0

Technical descriptions
Cordivari offers two types of coating/material, all suitable Insulation Cathode protection
to drinkable water according to D.M. N° 174 dated Hard foam insulation until 500 litres. (*) On 800 and 1000 Magnesium anode Anoden-tester which allows to
16/04/04. litres calorifiers soft foam with 100 mm thickness check easily the real consumption of the magnesium bar
- Tank and heat exchanger in Stainless Steel 316L Electronical anode on demand – only for Polywarm® (see
- Tank and heat exchangers in carbon steel coated with External lining page 71)
Polywarm®. Galvanized sheet cover.
The special shape of the fixed coil guarantees the total On 800 and 1000 lt SCAI grey Gasket-Flange Plate
heating of water. Silicone gaskets suitable for alimentary use for max
Drain pipe
Application External confluence through jointable pipe. temperature up to 200° C. (D.M. n.174 dated 2004);
Production and Storage of sanitary water. • XSB/XSC VT : stainless steel 316L flange cover
Warranty • WSB/WSC VT : Polywarm® coated flange cover
Heat exchanger: - 5 years (Stainless Steel 316L)
1 fixed coil in Stainless Steel 316L (XSB version) or in - 5 years (Polywarm®) Adjustable Supporting feet
Polywarm® coated carbon steel (WSB). See general sales conditions and warranty.
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

Even if the tanks are tested from 60° up to 95° C the local legislation has always to be observed.

Capacity Df De H A H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11 4 2-7 5 9 13

[liters] [mm] Connections Gas F

150 400 500 1410 1496 53 270 310 205 650 850 895 980 850 1050 1170 Øi 120 1" 3/4" 3/4" 1"1/4

200 450 550 1430 1532 53 280 320 215 730 920 985 1050 920 1100 1180 Øi 120 1" 1" 3/4" 1"1/4

300 550 650 1480 1616 53 305 375 240 665 855 910 1015 885 1065 1205 Øi 160 1" 1" 1" 1"1/4

400 600 700 1760 1894 53 320 390 255 745 940 990 1090 960 1330 1470 Øi 160 1" 1" 1" 1"1/4

500 650 750 1780 1931 53 330 405 265 890 1080 1122 1225 1095 1340 1480 Øi 160 1" 1" 1" 1"1/4

(*) 800 750 950 2158 2358 101 428 483 493 1148 1304 1375 1478 1418 1618 1808 Øi 160 1"1/4 1" 1" 1"1/4

(*) 1000 850 1050 2192 2431 89 439 499 524 1069 1279 1339 1439 1429 1639 1819 Øi 160 1"1/4 1"1/4 1" 1"1/2

35
BOL. BOLLY2 XSB/XSC VT
STAINLESS STEEL 316L CALORIFIERS WITH TWIN FIXED COILS AND HARD FOAM INSULATION

STAINLESS STEEL 316L


Capacity BOL. BOLLY2 XSB VT P. Max

[liters] ART. NR. Price [€] [Bar]

150 3135052010001 1.901,00 10


200 3135052010002 2.267,00 10
300 3135052010003 2.893,00 10
500 3135052010005 4.020,00 10

Press. MAX
Capacity BOL. BOLLY2 XSC VT
accumulo
[liters] ART. NR. Price [€] [Bar]
STORAGE EXCHANGER
Pmax Tmax Pmax Tmax
(*) 800 3138052010006 5.613,00 10

Vedi Tab. 95° C 12 bar 99° C (*) 1000 3138052010007 6.581,00 8

(*) on 800 and 1000 Lt 100 mm polyurethane soft foam insulation

BOL. BOLLY2 WSB/WSC VT For graphics and exchanger pressure


POLYWARM® CALORIFIERS WITH TWIN FIXED COILS AND HARD FOAM INSULATION loss data see page 92

Capacity BOL. BOLLY2 WSB VT P. Max


POLYWARM®

[liters] ART. NR. Price [€] [Bar]

150 3135162320001 870,00 10


200 3135162320002 940,00 10
300 3135162320003 1.099,00 10
400 3135162320004 1.332,00 10
500 3135162320005 1.461,00 10

Capacity BOL. BOLLY2 WSC VT P. Max


I
SISTEM LARI [liters] ART. NR. Price [€] [Bar]
ICI SO
STORAGE EXCHANGER Product component of a complete Sun un TERM

Pmax Tmax Pmax Tmax Solution Solar Thermal System (*) 800 3138162320106 2.074,00 10
Please refer Sun Solution Cordivari
Vedi Tab. 90° C 12 bar 99° C LIST mique
INO
201
0
(*) 1000 3138162320107 2.303,00 8
catalogue C ATA
èm
LO GO
es Th
er

(*) on 800 and 1000 Lt 100 mm polyurethane soft foam insulation


PROMPT DELIVERY
Grey highlighted products are
dispatched in 1-5 working days.
(Delivery time excluded)

LOWER EXCHANGER UPPER EXCHANGER


Heat Exchanger Ignition Heating Heat exchangers Ignition Weight
Capacity Output DHW Production Output DHW Production
Surface timing volume surface timing
80/10-45 80/10-45 80/10-60 80/10-45 80/60-10-45 80/10-45 80/10-45 80/10-60 80/10-45 80/60-10-45
[liters] [m2] [lt] [m2] [Kg]
[KW] [min] [min] [lt/h] [lt/10’] [KW] [min] [min] [lt/h] [lt/10’]
150 1 26,5 14,9 27,3 651 280 52 0,44 11,9 11,2 20,9 289 107 68
200 1,4 36,7 14,4 26,3 904 379 53 0,41 11,4 11,9 22,1 277 106 77
300 1,7 43,9 18,0 32,9 1083 523 104 0,70 19,4 13,8 25,4 475 198 105
400 1,9 50,9 20,7 37,8 1256 666 177 1,34 36,4 12,6 23,1 897 351 154
500 2,6 66,9 20,0 36,0 1653 847 170 0,96 26,6 16,5 30,3 654 303 167
(*) 800 3 75,0 34,0 48,0 1842 1221 269 1,30 36,3 19,0 30,3 895 457 181
(*) 1000 3,5 87,5 38,0 52,4 2150 1501 340 1,80 49,5 17,7 32,3 1222 592 235
Datas have been calculated on following basis: primary hot water at 80°, DHW from 10° to 45° and storage at 60°

3/4” 3/4”

3/4” ADDITIONAL FINNED COIL 3/4” ADDITIONAL FINNED COIL.


WITH FLANGE PLATE AND GASKET.

ART. NR. DESCRIPTION Price [€] ART. NR. DESCRIPTION Price [€]
Additional finned coil for BOLLY Polywarm® Additional copper finned coil
5221000910001 333,00 5205000060002 270,00
Surface=0,94m2 - Diam.=145 mm - L=370 mm Surface=0,94m2 - Diam.=145 mm - L=370 mm
AVAILABLE FOR CAPACITY OVER LT. 300, ONLY.
Additional finned coil for BOLLY Inox
5221000010001 366,00
Surface=0,94m2 - Diam.=145 mm - L=370 mm
AVAILABLE FOR CAPACITY OVER LT. 300, ONLY.

36
CONNECTIONS
1 Drain 3/4” Gas F
2 Lower heat exchanger outlet
3 Connection for thermostat 1/2" Gas F

CALORIFIERS
4 Blind flange for inspection
5 Domestic Cold Water Circuit Inlet
6 Connection for thermostat 1/2" Gas F
7 Lower heat exchanger inlet
Connection for
8
magnesium anode 1”1/4 Gas F
9 Connection for electrical immersion resistance 1”1/2 Gas F
De 10 Upper heat exchanger outlet
11 Connection for Instrumentation 1/2" Gas F
Df 12 Connection for recirculation
(16) 13 Upper heat exchanger inlet
14 Connection for Instrumentation 1/2" Gas F
Connection for 2nd magnesium anode 1”1/4 Gas F (only for 800
15
and 1000 lt.)
16 Domestic Hot water outlet
H12 (13) H13 (14) (15)
On request:
H11 (12) "EASY CONTROL” Electronic Display mounted
A

and connected.
H10 (11) Available as accessories - Euro 408,00 – see
H9 (10) page 70
H8 (9)
H6 (7) H7 (8)
(5)
H

H5 (6)

(2) (7) (10) (16) (1) (4)


H3 (3) (4) (12) (13) (8) (15)
H2 (2)
H4 (5)

H1 (1) (3) (6)


0 (9) (11) (14)

Technical descriptions Insulation Cathode protection


Cordivari offers two types of materials, all suitable Hard foam insulation until 500 litres. (*) On 800 and 1000 Magnesium anode Anoden-tester which allows to
to drinkable water according to D.M. N° 174 dated litres tanks soft foam with 100 mm thickness. check easily the real consumption of the magnesium bar
16/04/04. Electronical anode on demand – only for Polywarm® (see
- Tank and heat exchanger in Stainless Steel 316L External lining page 71)
- Tank and heat exchangers in carbon steel coated with Galvanized sheet cover.
Polywarm®. On 800 and 1000 lt SCAI grey Gasket-Flange Plate
The special shape of the fixed coil guarantees the total
heating of water. Drain pipe Silicone gaskets suitable for alimentary use for max
External confluence through jointable pipe. temperature up to 200° C. (D.M. n.174 dated 2004);
Application • XSB/XSC VT : stainless steel 316L flange cover
Production and Storage of sanitary water. Warranty • WSB/WSC VT : Polywarm® coated flange cover
- 5 years (Stainless Steel 316L)
Heat exchanger: - 5 years (Polywarm®) Adjustable Supporting feet
2 fixed coils in Stainless Steel 316L (XSB version) or in in See general sales conditions and warranty.
Polywarm® coated carbon steel (WSB).
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

Even if the tanks are tested from 60° up to 95° C the local legislation has always to be observed.
2-7
Capacity Df De H A H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11 H12 H13 4 5 12 16
10-13
[liters] [mm] Connections Gas F

150 400 500 1410 1496 53 270 310 205 650 850 880 910 940 1030 1060 1180 1180 Øi 120 1" 3/4" 3/4" 1"1/4

200 450 550 1430 1532 53 280 320 215 730 920 960 970 1010 1100 1110 1200 1200 Øi 120 1" 3/4" 3/4" 1"1/4

300 550 650 1480 1616 53 305 375 240 665 855 895 945 975 1070 1095 1215 1225 Øi 160 1" 1" 1" 1"1/4

400 600 700 1760 1894 53 320 390 255 745 940 960 1010 1040 1230 1250 1480 1480 Øi 160 1" 1" 1" 1"1/4

500 650 750 1780 1931 53 330 405 265 890 1080 1110 1160 1200 1290 1320 1490 1490 Øi 160 1" 1" 1" 1"1/4

(*) 800 750 950 2158 2360 101 428 483 493 1103 1304 1338 1388 1423 1573 1598 1788 1808 Øi 160 1"1/4 1" 1" 1"1/4

(*) 1000 850 1050 2192 2440 89 439 499 524 1069 1279 1319 1364 1399 1609 1584 1819 1819 Øi 160 1"1/4 1"1/4 1" 1"1/2

37
BOL. BOLLY2 WSB/WSC-DF
POLYWARM® CALORIFIERS WITH DOUBLE BOTTOM AND TWIN COIL FIXED EXCHANGER AND HARD FOAM INSULATION

Capacity BOL. BOLLY2 WSB-DF P. Max

[liters] ART. NR. Price [€] [Bar]

300 3135162320103 1.411,00 10


400 3135162320104 1.734,00 10
500 3135162320105 1.896,00 10

Capacity BOL. BOLLY2 WSC-DF P. Max

(*) 800 3138162320006 2.537,00 10


(*) 1000 3138162320007 2.870,00 8

STORAGE EXCHANGER
Pmax Tmax Pmax Tmax
Vedi Tab. 90° C 12 bar 99° C

Technical descriptions Insulation Warranty


Carbon steel Polywarm® coated calorifier suitable for Hard foam insulation until 500 litres. (*) On 800 and 1000 - 5 years
drinkable water in accordance to D.M. n.174 dated 2004. litres tanks soft foam with 100 mm thickness. See general sales conditions and warranty
The double bottom allows to have a bigger heat exchanger
External lining Cathode protection
surface and to fight efficiently against the legionellosis, as SCAI grey complete with top and flange cover. Magnesium anode Anoden-tester which allows to
the whole tank is heated. check easily the real consumption of the magnesium bar
Heat exchanger Electronical anode on demand (see page 71)
Application Special Double Bottom to heat the entire domestic water
Production and Storage of sanitary hot water for domestic volume in conjuction with serpentine design twin coils for Gasket-Flange Plate
and industrial uses with double energy source. maximum surface area and heat exchange. - Silicone gaskets suitable for alimentary use for max
Manufactured in Polywarm® coating suitable for drinkable
Corrosion-proofing water according to D.M. n.174 dated 2004.
temperature up to 200° C. (D.M. n.174 dated 2004);
Polywarm, suitable for drinking water. - Polywarm® coated flange cover.
Particularly suitable for thermal solar systems.

Even if the tanks are tested from 60° up to 90°C the local legislation has always to be observed.

LOWER EXCHANGER UPPER EXCHANGER


Ignition Ignition Weight
Capacity Heat exchangers surface Output DHW Production Heat exchangers surface Output DHW Production
timing timing
[liters] [m2] [KW] [min] [lt/h] [lt/10’] [m2] [KW] [min] [lt/h] [lt/10’] [Kg]

300 2,1 55,56 18,6 1341,20 622,26 0,70 18,20 15,4 406,00 191,33 118

400 2,35 58,75 23,0 1442,90 735,22 1,34 33,50 14,0 823,49 299,67 129

500 3,15 79,95 21,3 1935,00 923,65 0,96 24,00 19,7 589,87 276,27 150

(*) 800 3,59 89,75 28,4 2204,26 1117,38 1,30 32,50 21,0 798,00 383,00 199

(*) 1000 4,6 115,00 28,9 2825,71 1470,95 1,40 35,00 22,0 860,00 477,00 244

3/4” 3/4”

3/4” ADDITIONAL FINNED COIL 3/4” ADDITIONAL FINNED COIL.


WITH FLANGE PLATE AND GASKET.

ART. NR. DESCRIPTION Price [€] ART. NR. DESCRIPTION Price [€]
®
Additional finned coil for BOLLY Polywarm Additional copper finned coil
5221000910001 333,00 5205000060002 270,00
Surface=0,94m2 - Diam.=145 mm - L=370 mm Surface=0,94m2 - Diam.=145 mm - L=370 mm
AVAILABLE FOR CAPACITY OVER LT. 300, ONLY. AVAILABLE FOR CAPACITY OVER LT. 300, ONLY.

38
De
CONNECTIONS
Df 1 Lower exchanger outlet
(16) 2 Connection for thermostat 1/2" Gas F
3 Blind flange for inspection

CALORIFIERS
4 Domestic Cold Water Circuit Inlet
H11 (13)
5 Connection for thermostat 1/2" Gas F
H11 (13) H12 (14) (15)
6 Lower exchanger inlet
7 Connection for magnesium anode 1”1/4 Gas F
H10 (12)
H9 (11) 8 Connection for electrical immersion resistance 1”1/2 Gas F
ANODEN TESTER

9 Upper exchanger outlet


H8 (9) H7 (8) 11 Connection for Instrumentation 1/2" Gas F
A

H5 (6) H6 (7) 12 Connection for recirculation


H

13 Upper exchanger inlet


H4 (5) 14 Connection for Instrumentation 1/2" Gas F
Connection for 2nd magnesium anode 1”1/4 Gas F (only for 800
15
and 1000 lt.)
16 Domestic Hot water outlet
H3 (4) H2 (2) (3)

H1 (1)

0
(4)

(1) (6) (9) (16)


(3) (7) (15)
(12) (13)

(2) (5) (8)


(11) (14)

Cordivari propose on BOLLY 2 DF an


exchanging double-bottom: where
DHW at the bottom part of the boiler
can be kept at safe temperature to
prevent any bacterial diffusions.
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

Capacity Df De H A H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11 H12 3 1-4-6-9-13-16

[liters] [mm] Connections Gas F

300 550 670 1520 1660 210 405 440 715 895 925 965 985 1105 1105 1225 1235 Øi 160 1”

400 600 720 1795 1935 217 415 440 785 965 1010 1050 1065 1245 1275 1485 1495 Øi 160 1”

500 650 790 1835 1200 239 440 460 930 1110 1142 1180 1205 1325 1335 1505 1515 Øi 160 1”

800 750 950 2187 1285 272 482 492 1102 1327 1367 1407 1422 1572 1597 1797 1807 Øi 160 1”1/4

1000 850 1050 2183 1425 304 505 530 1030 1280 1295 1360 1420 1450 1595 1770 1770 Øi 160 1” 1/4

39
BOL. BOLLYTERM HP
THERMODYNAMIC CALORIFIER WITH HEAT PUMP NEW

Room Average electrical Electrical


Heat Pump
Capacity BOL. BOLLYTERM HP temperature power absorbed by integration
thermal output
min/max the Heat Pump power
[liters] ART. NR. Price [€] [°C] [W] [W] [W]

200 3180162330002 3.380,00


7/32 1940 655 1500
300 3180162330003 3.550,00

Heat Exchanger Suggested Solar Room Average electrical Electrical


BOL. BOLLYTERM HP Heat Pump
Capacity Surface for Solar Collectors temperature power absorbed by integration
(with 1 fixed coil) thermal output
collector circuit surface min/max the Heat Pump power
[liters] ART. NR. Price [€] [m2] [m2] [°C] [W] [W] [W]
STORAGE EXCHANGER
200 3181162330002 3.505,00 0,8 4
Pmax Tmax Pmax Tmax 7/32 1940 655 1500
10 bar 90° C 12 bar 99° C 300 3181162330003 3.760,00 1,2 6

HEAT PUMP TECHNICAL DATA


Inlet and Minimum
Power Max water Coolant Acoustic Max pipes
Coolant C.O.P. outlet air pipes
supplier temperature Pressure level lenght
I
SISTEM LARI (45° C) capacity diameter
ICI SO
Product component of a complete Sun un TERM
[V / Ph / Hz] [°C] [type] [g] db (A) [m3/h] [m] [mm]
Solution Solar Thermal System
Please refer Sun Solution Cordivari 201
0

mique
230 / 1 / 50 60 R134a 950 52 3,25 450 10 160
INO
LIST

catalogue CAT
ALO
èmes
GO Ther

Technical descriptions Insulation Cathode protection


Carbon steel Polywarm® coated thermodynamic calorifier suitable Hard ecological foam polyurethane. Sufaces are treated with a Magnesium anode Anoden-tester which allows to check easily
for drinkable water in accordance to D.M. n.174 dated 2004. special detaching substance so that the insulation can be easly the real consumption of the magnesium bar.
removed when the technical life of the calorifier is finished. Electronical anode on demand (see page 71)
Application
Production and Storage of sanitary hot water for domestic and External lining Gasket-Flange Plate
industrial uses with double energy source. SCAI grey. - Silicone gaskets suitable for alimentary use for max temperature
Drain pipe up to 200° C. (D.M. n.174 dated 2004);
Heat exchanger (only integrated coil version): - Polywarm® coated flange cover.
1 fixed coil in carbon steel coated with Polywarm® suitable for External confluence through jointable pipe.
drinkable water according to D.M. n.174 dated 2004. Warranty
- 5 years for the calorifier
Electrical resistance (included): - 2 years for Heat Pump
Power: 1500 Watt - "plug&play" model See general sales conditions and warranty.

New BOLLYTERM HP is a thermodynamical producer of D.H.W. with integrated Heat Pump. Integration coil is equipped to be used with a solar system being so integrated by solar energy.
Heat Pump principle is based on the use of a special gas that under the compression first and then the A convenient and ecological way to use all natural resources such as Sun and Air.
expansion allows to obtain a real meduim C.O.P. value of > 3.

WITH NEW BOLLYTERM HP IT'S NOW POSSIBLE TO:


• REFRESH
• DEHUMIDIFY

40
BOLLYTERM HP
De CONNECTIONS
Int 1 Drain 3/4” Gas F
2 Connection for electrical immersion resistance 1”1/2 Gas F
3 Domestic Cold Water Circuit Inlet 1" Gas F

CALORIFIERS
4 Connection for Instrumentation 1/2" Gas F
5 Blind flange for inspection ø 170
6 Connection for Instrumentation 1/2" Gas F
7 Additional connection 1" Gas F
8 Connection for anode
H8 (9) 9 Domestic Hot water outlet 1" Gas M
H6 (7) H7 (8)
H

H5 (6)
A

H4 (4) (5)

H3 (3)
H2 (2)
Capacity Df De Int H A H1 H2 H3 H4 H5 H6 H7 H8
H1 (1)
[liters] [mm]

Df 200 550 650 380 1620 1750 55 230 240 655 895 915 915 980

300 550 650 380 1920 2030 55 230 240 655 1165 1205 1205 1280

BOLLYTERM HP (with 1 fixed coil)


De CONNECTIONS
Int 1 Drain 3/4” Gas F
2 Domestic Cold Water Circuit Inlet 1" Gas F
3 Heat exchanger inlet 1" Gas F
4 Connection for Instrumentation 1/2" Gas F
5 Blind flange for inspection ø 170
6 Connection for Instrumentation 1/2" Gas F
7 Heat exchanger outlet 1" Gas F
8 Connection for Instrumentation 1/2" Gas F
H11 (13) 9 Integrazione elettrica 1" 1/2 Gas F
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

H9 (11) H10 (12) 10 Connection for Instrumentation 1/2" Gas F


H8 (10) 11 Additional connection 1" Gas F
12 Connection for anode
H

13 Domestic Hot water outlet 1" Gas M

H7 (8) (9)
A

H6 (7)

H5 (6)

H4 (4) (5)
H3 (3)
H2 (2)

Capacity Df De Int H A H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11


H1 (1)
[liters] [mm]
Df 200 550 650 380 1620 1750 55 240 295 365 500 570 600 895 915 915 980

300 550 650 380 1920 2030 55 240 305 375 565 715 745 1165 1205 1205 1280

41
BOL. INTERKA SOLARE
STAINLESS STEEL 316L/ POLYWARM® DOUBLE WALLED HARD FOAM INSULATED TANK IN TANK CALORIFIERS (for gravity Solar Thermal System)

BOL. INTERKA SOLARE BOL. INTERKA SOLARE Exchanger Double wall


Capacity Weight
Stainless Steel Polywarm® Surface volume
2
[liters] ART. NR. Price [€] ART. NR. Price [€] [m ] [liters] [Kg]
150 3068050981002 1.214,00 3068160981002 761,00 0,80 8,0 58
200 3068050981003 1.403,00 3068160981003 842,00 1,20 12,0 72
300 3068050981004 1.736,00 3068160981004 1.003,00 2,05 21,0 109

Stainless Steel Polywarm® I


SISTEM LARI
ICI SO
STORAGE EXCHANGER STORAGE EXCHANGER Product component of a complete Sun un TERM

Solution Solar Thermal System


Pmax Tmax Pmax Tmax Pmax Tmax Pmax Tmax
Please refer Sun Solution Cordivari
6 bar 6 bar
0
201

95° C 2,5 bar 99° C 90° C 2,5 bar 99° C catalogue èmes
CAT
ALO
GO
LIST
Ther
mique
INO

Technical descriptions Application Warranty


These tank in tank calorifiers are specifically planned for production Production and Storage of DHW. Expecially suitable for gravity - 5 years (Stainless Steel 316L)
and storage of Sanitary Hot Water in gravity circulation solar solar thermal systems installation. - 5 anni (Polywarm®)
thermal systems. Heat exchange is done thanks to the double wall See general sales conditions and warranty
covering the internal body of the tanks. The particular structure Insulation
and connections enable to install the tank directly on the Solar Insulated with 50 mm hard foam polyurethane, conductivity 0,035 Heat exchanger
Panel frame. W/m°C. – DHW tank in Stainless Steel AISI 316L and double wall for
They are realized in: primary circuit in carbon steel
– Stainless Steel 316L, suitable for storage of drinking water External lining – DHW tank in Polywarm® and double wall for primary circuit in
according to D.M N 174 dated 16 04 04. Metal grey RAL 7035 and polyurethane ABS side covers. carbon steel
– Polywarm® suitable for drinking water according to D.M N 174
dated 16 04 04. Cathode protection
Magnesium anode

(3)

(6*)(7)
Ø550

Ø450

(8)(9)

H1(1) H2(5) (1)(5)


15°

(2)(4) 0
45°

0 L1 (2)(3) L2 (4)

P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

CONNECTIONS
1 Domestic Cold Water Circuit Inlet 1" Gas F
In Solar Thermal Systems the use of a combined TP valve (Temperature and Pressure) is always recommended.
2 Solar collector connection 3/4" Gas F
3 Surge volume 1/2" Gas F
4 Solar collector connection 3/4" Gas F
Capacity L L1 L2 H1 H2 5 Domestic Hot water outlet 1" Gas F
[liters] [mm] 6 Connection for electrical integration (on request)
150 1227 343 783 88 100 7 Magnesium anode
200 1487 353 1043 88 100 8
Connection for instrumentation 1/2" Gas F
300 2172 343 1723 88 100 9

42
SOLAR THERMAL SYSTEM
DOMESTIC HOT WATER AND HEATING SYSTEM

CALORIFIERS
PRODUCTS IN CONFORMITY TO EUP DIRECTIVE
ENERGY USING PRODUCTS - 2005/32/CE

GRAVITY CIRCULATION SYSTEMS (WITH INTERKA SOLARE CALORIFIER)

FORCED CIRCULATION SYSTEMS (WITH BOLLY 1 CALORIFIER)

FORCED CIRCULATION SYSTEMS (WITH BOLLY 2 CALORIFIER)

FORCED CIRCULATION SYSTEMS (WITH COMBI / ECO-COMBI MULTI FUEL ENERGY CYLINDERS)

FORCED CIRCULATION SYSTEMS (WITH EXTRA PLUS CALORIFIER)

=<D2? 5 =

FORCED CIRCULATION SYSTEMS (WITH BOLLYTERM HP WITH HEAT PUMP)

FOR SOLAR THERMAL SYSTEMS PRODUCTS


SEE SOLAR THERMAL SYSTEMS CORDIVARI CATALOGUE

43
BOL. INTERKA XSB
STAINLESS STEEL 316L DOUBLE WALLED HARD FOAM INSULATED TANK IN TANK CALORIFIERS

STAINLESS STEEL 316L Heat exchangers DHW


Capacity BOL. INTERKA XSB Output Ignition Weight
surface timing Production
2
[liters] ART. NR. Price [€] [m ] [KW] [min] [lt/h] [lt/10’] [Kg]
80 3203050130001 966,00 0,36 8 27 190 112 24
100 3203050130002 1.054,00 0,54 11 24 263 144 30
150 3203050130003 1.241,00 0,82 15 26 372 212 41
200 3203050130004 1.500,00 1,00 20 25 508 285 49
300 3203050130005 1.766,00 1,75 24 31 606 401 65
Datas have been calculated on following basis. Hot Water at 80° C, DHW from 10° to 45° C and storage at 60° C

STORAGE EXCHANGER
Pmax Tmax Pmax Tmax
6 bar 95° C 1,5 bar 99° C

BOL. INTERKA WSB


POLYWARM® DOUBLE WALLED HARD FOAM INSULATED TANK IN TANK CALORIFIERS

Heat exchangers Ignition DHW


Capacity BOL. INTERKA WSB Output timing Weight
surface Production
POLYWARM®

2
[liters] ART. NR. Price [€] [m ] [KW] [min] [lt/h] [lt/10’] [Kg]
80 3203160310001 422,00 0,36 8 27 190 112 24
100 3203160310002 440,00 0,54 11 24 263 144 30
150 3203160310003 507,00 0,82 15 26 372 212 41
200 3203160310004 619,00 1,00 20 25 508 285 49
300 3203160310005 751,00 1,75 24 31 606 401 65
Datas have been calculated on following basis. Hot Water at 80° C, DHW from 10° to 45° C and storage at 60° C

STORAGE EXCHANGER PROMPT DELIVERY


Grey highlighted products are
Pmax Tmax Pmax Tmax dispatched in 1-5 working days.
6 bar 90° C 1,5 bar 99° C (Delivery time excluded)

44
CONNECTIONS
1 Connection for instrumentation 1/2" Gas F
2 Domestic Hot water outlet
3 Primary circuit inlet

CALORIFIERS
4 Primary circuit outlet
5 Domestic Cold water inlet
Connection for recirculation / electrical
6
heating 1”1/4 Gas F
Connection for magnesium anode
7
1”1/4 Gas F
L1 L2 L3 L4
(1) (2) (3) (4) (5)
0

(2) (3)

(6)
(7) (1)

180
De
Df

(6)
(7)

(4) (5)
L

Technical descriptions Application Heat exchanger:


Double walled tank in tank calorifiers are planned for Production and Storage of DHW for domestic and – DHW tank in Stainless Steel AISI 316L and double wall
production and storage of DHW, with 2 different types of industrial use. for primary circuit in carbon steel
materials/coating suitable for drinking water according to – DHW tank in Polywarm® and double wall for primary
D.M N 174 dated 16 04 04 : Insulation circuit in carbon steel
- Stainless Steel 316L Hard foam polyurethane, conductivity 0,035 W/K, with
- Carbon steel Polywarm® coated external lining in metal galvanized sheet and side covers. Cathode protection
Magnesium anode Simpletest which allows to check
Heat exchange is done thanks to the double wall which Warranty the real consumption of the anode simply by pushing the
covers the internal body of the tank - 5 years (Stainless Steel 316 L) valve. In case of water going out, change the anode.
With supports brackets interka are planned for installation - 5 years (Polywarm®) Electronical anode on demand only for INTERKA WSB (see
fixed on wall better in horizontal position. Vertical position, See general sales conditions and warranty. page 71)
even if possible, reduce the storage volume and thermal
performances.

Even if the tanks are tested from 90° up to 95° the local legislation
has always to been observed.
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

Capacity Df De L L1 L2 L3 L4 2-3-4-5

[liters] [mm] Connections Gas F

80 400 456 770 165 260 510 705 1"

100 400 456 920 165 260 660 755 1"

150 450 510 1086 173 268 818 913 1"

200 500 560 1170 190 285 885 980 1"

300 550 610 1590 200 295 1295 1390 1"

45
TERM. PUFFER VC /VC SERP. VT
HEATING WATER BUFFER TANK WITH OR WITHOUT HEAT EXCHANGER

Capacity TERM PUFFER VC VT

[liters] ART. NR. Price [€]

200 3251162281501 563,00


300 3251162281502 637,00
500 3251162281503 716,00
800 3251162281504 900,00
1000 3251162281505 983,00
1500 3251162281506 1.423,00
2000 3251162281507 1.816,00

STORAGE EXCHANGER 3000 3251162281680 2.972,00


Pmax Tmax Pmax Tmax 4000 3251162281681 3.911,00
3 bar 99° C 12 bar 99° C 5000 3251162281682 4.930,00
Coil version PROMPT DELIVERY
Grey highlighted products are
dispatched in 1-5 working days.
(Delivery time excluded)

TERM PUFFER VC VT (COIL VERSION)


Capacity Exchanger Surface
ART. NR. Price [€]
[liters] [m2]

300 3251162281201 1,0 790,00


500 3251162281202 2,1 983,00
800 3251162281203 2,5 1.144,00
1000 3251162281204 3,0 1.268,00
1500 3251162281205 3,7 1.859,00
2000 3251162281206 4,0 2.356,00
)
3000 3251162281670 6,4 3.776,00
4000 3251162281671 7,0 4.801,00
5000 3251162281672 7,8 5.735,00

PROMPT DELIVERY
Grey highlighted products are
dispatched in 1-5 working days.
(Delivery time excluded)

Technical descriptions Application Heat exchanger:


Buffers are used in units with a typically discontinuous energy Production and Storage of heating hot water. Used to improve In carbon steel
source .The buffer tank is connected with the heating system flexibility of pellets, stoves and burners.
and do not need any coating inside. Made in carbon steel outside Warranty
painted. - 2 years
Version with heat exchanger allows use together with a solar Insulation See general sales conditions and warranty
installation. Soft foam polyurethane 100mm, thermal conductivity 0,038W/mK
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

There is no need of any anti-corrosion treatment due to the fact with SCAI grey Ral 9006, complete with top cover.
that the buffer is in a closed circuit without any adding air.
External lining
Grey SCAI RAL 9006 and top cover.

For graphics and exchanger pressure loss data see page 92

46
CONNECTIONS
De
Df 1 -2
Heating return/To Generator 1” 1/2 Gas F
4 -5
(15)
3-6 Heating delivery/From Generator 1” 1/2 Gas F
7- 8 - 9
Connection for instrumentation 1/2" Gas F
10 - 12
11 Connection for electrical integration 1” 1/2 Gas F

H7 (3) (12) (6) 13 Heat exchanger outlet


14 Heat exchanger inlet
H6 (11)
15 Heating delivery/From Generator 1” 1/2 Gas F
H5 (10)
A

H4 (2) (5) H9 (14)


H

H3 (9)

H2 (8)

H1 (1) (7) (4)


H8 (13)

BUFFER TANKS
(13) (14)

(4) (15) (1)


(5) (2)
(6) (3)

(11)
(7) (8)
(9) (10) (12)

Coil version
1-2-3-4-5-
Capacity Df De H A H1 H2 H3 H4 H5 H6 H7 16 H8 H9 13 14
6-11-15
[liters] [mm] [mm] Connections Gas F
200 450 650 1349 1366 241 441 641 641 841 941 1041 1”1/2 - - - - -
300 550 750 1390 1414 255 455 655 605 855 955 1055 1”1/2 - 255 755 1” 1”
500 650 850 1720 1747 270 545 820 770 1095 1233 1370 1”1/2 - 270 990 1” 1”
800 790 990 1908 1946 308 612 916 924 1220 1372 1524 1”1/2 - 308 938 1”1/4 1”1/4
1000 790 990 2198 2231 308 646 983 1094 1321 1489 1658 1”1/2 - 308 1078 1”1/4 1”1/4
1500 950 1150 2301 2346 336 711 1086 1236 1461 1649 1836 1”1/2 - 336 1106 1”1/4 1”1/4
2000 1100 1300 2370 2430 371 758 1146 1321 1533 1726 1921 1”1/2 - 371 1071 1”1/4 1”1/4
3000 1250 1450 2854 2931 569 1019 1969 1769 1919 2144 2369 2” 1” 669 1649 1”1/4 1”1/4
4000 1450 1650 3060 3091 656 1106 1956 1706 2006 2231 2456 2” 2” 756 1666 1”1/4 1”1/4
5000 1600 1800 3152 3186 762 1195 1892 1592 2060 2276 2492 2” 2” 792 1702 1”1/4 1”1/4

47
TERM. PUFFER 2 STRATIFICAZIONE
EASY STRATIFICATION BUFFERS

LOWER UPPER
TERM. PUFFER 2
Capacity Heat exchangers Heat exchangers
Stratification Buffer
surface surface
Separator
stratification plate [liters] ART. NR. Price [€] [m2] [m2]

800 3251162282004 1.710,00 3,0 2,4


1000 3251162282005 1.933,00 4,0 2,4

STORAGE EXCHANGER
Pmax Tmax Pmax Tmax
3 bar 99° C 12 bar 99° C

Coil version

Technical descriptions Application External lining


Buffers are mainly used in special heating systems that have been Production and storage of central heating hot water. SCAI grey RAL 9006 with top soft PVC flange.
designed to take benefit of a discontinuous energy source , such They are used to improve reaction flexibility of the stoves,
as a fireplaces or wood stoves burners, fireplaces or in low content water heating systems. Heat exchanger:
Being connected to the heating system it doesn’t need any Ideally suited to biomass boiler in conjunction with solar thermal 2 fixed coils in carbon steel
corrosion proofing, it’s made in carbon steel and is raw inside and system.
painted outside. Warranty
It can be connected to a solar system thanks to the fixed coil. Insulation - 2 years
There is no need of any anti-corrosion treatment due to the fact Soft foam polyurethane ,100 mm thickness conductivity 0,038 W/ See general sales conditions and warranty
that the buffer is in a closed circuit without any adding air. mK.

For graphics and exchanger pressure loss data see page 92

EASY STRATIFICATION BUFFERS THERMOGRAPHY

1 2 3 4 5 6

SEQUENCE OF THERMOGRAPHIC IMAGES THAT SHOW HOW A SYSTEM WORKS WITH THE EASY STRATIFICATION BUFFER

1-2-3 PHASES 4-5-6 PHASES


The “stratification filling” circuit , connected to a solar panel start to heat the heating water in In the next phases The “stratification filling” circuit starts to heat sanitary hot water also in the
the upper part of the Buffer. It’s equipped with a separator plate that limits the heating hot water lower part of the buffer.
prepared in the upper part of the buffer mixes with the below storaged cold water.
Since early morning you can, so , use solar energy without waiting that the entire volume reaches
the right temperature.

48
De CONNECTIONS
Df 1 Heating return/To Generator 1” 1/2 Gas F
(19)
2
To Generator 1"1/2 Gas F
3

H12 (8) 4 Heating delivery/From Generator 1” 1/2 Gas F


(13) (4) 5 Connection for instrumentation 1/2" Gas F
H11 (18)
6
To Generator 1"1/2 Gas F
7
H10 (12)
8 Heating delivery/From Generator 1” 1/2 Gas F
H9 (3) (7) H8 (17)
9 Heating return/To Generator 1"1/2 Gas F
A

H7 (2) (6) 10
H6 (14)
H5 (11)
11
H

Connection for instrumentation 1/2" Gas F


H4 (16) 12
13
14 Connection for electrical integration 1"1/2 Gas F
H3 (10)
15 Lower exchanger outlet 1" Gas F
16 Lower exchanger inlet 1" Gas F

H2 (1) (5) (9) 17 Upper exchanger outlet 1" Gas F


H1 (15)
18 Upper exchanger inlet 1" Gas F
19 Heating delivery/From Generator 1” 1/2 Gas F

BUFFER TANKS
(19)
(1) (2) (3) (4) (9) (6) (7) (8)

(15) (16) (17) (18)


(14)
(5)
(10) (11)
(12) (13)
INTERNAL STRUCTURE OF STRATIFICATION BUFFER 2

New Easy Stratification Buffers improve the possibility to integrate and combine biomass energy source
and solar energy. In fact, this buffer with its double exchangers is able to be connected to the solar
circuit (called “stratificated filling ) , that allows to heat immediatelly only the upper part of the buffer Insulation in polyurethane thickness 100 mm
and only afterwards, the bottom part.
Since early morning you can use solar energy without waiting that the entire volume reachs the
temperature needed. In order to take fully advantage of the stratification principles the Easy Stratification
Upper fixed heat exchanger
Buffers are equipped with a separator plate positioned in the middle that limits the possibility to mix
the water between the top and bottom volume.

Separator stratification plate

Buffer
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

Lower fixed heat exchanger

Capacity Df De H A H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11 H12

[liters] [mm]
800 790 990 1908 1946 258 308 626 818 943 958 998 1118 1178 1261 1558 1578
1000 790 990 2198 2231 258 308 696 938 1083 1122 1158 1308 1338 1471 1748 1858

49
TERM. PUFFERMAS®
DOMESTIC HOT WATER STATION NEW
Max availability of DHW
TERM PUFFERMAS® VC VT Heat exchanger DHW Station max DHW Station max
Capacity TERM PUFFERMAWS VC VT (10-45°) with storage
with heat exchange surface power carriage
at 70°
[liters] ART. NR. Price [€] ART. NR. Price [€] [m2] [kW] [l/min] [liters]

500 3251162285703 2.511,00 3251162285603 2.761,00 2,1 70 kW 30 614


800 3251162285704 2.730,00 3251162285604 2.980,00 2,5 70 kW 30 983
1000 3251162285705 3.032,00 3251162285605 3.282,00 3,0 120 kW 50 1503
1500 3251162285706 3.500,00 3251162285606 3.750,00 3,7 120 kW 50 2254
Thermal values are referring to the following conditions
• Tank temperature 80° and suitable Energy source;
• Power and continuous DHW production from 10 to 45° C

STAINLESS STEEL PLATE


BUFFER TANK EXCHANGER
EXHANGER
Pmax Tmax Pmax Pmax Tmax
3 bar 99° C 6 bar 6 bar 99° C

Cordivari PUFFERMAS® System join the benefits of thermal storage with the comfort and Domestic Hot Water station (MACS): an external unit that immediately heat domestic water,
the convenience of an immediate production of DHW. using the heat energy stored in the Buffer thanks to the stainless steel plate exchanger, granting
PUFFERMAS is the innovative combination of two components : safety and comfort with the possibility to regulate outlet temperature.
The Multi-Heat Energy Buffer: a hot heating water tank, that works as thermal regulator allowing a
more regular working of the burner, limiting the stops and increasing working comfort.

Technical descriptions Application External lining


The immediate and fast production of D.H.W. granted by Immediate production of DHW with high perfomance and capacity, SCAI grey colour RAL9006 with top and flange cover in soft PVC.
the outside system steel plate exchange allow the following even if the installed power is not so much high.
benefits: Plate exchanger:
- to reduce dimensions of the water heater need it Insulation Plate in stainless steel. Insulated box in painted steel.
- easy maintenance Soft Foam polyurethane, thickness 100mm , conductivity 0,038W/
- easy maximum hygiene for anti-legionellosis bacteria’s mk. Warranty
- to produce more DHW than the quantity obtained by boiler with 2 years
similar capacity because heating hot water is stored See general sales conditions
at an highest temperature than DHW.
There is no need of any anti-corrosion treatment due to the fact
that the buffer is in a closed circuit without any adding air.

Optimize Performance
Performances are optimized thanks to the “Labyrinth Spreader” (Cordivari Patent) [Fig 1] that thanks to its spread shape allows a perfect stratification of the water that returns back from the plate exchange
to the tank:

Fig. 1 - Puffermas® stratification thermography

Fig. 2 - Normal buffer stratification thermography

50
De CONNECTIONS
Df 1 Heating return/To Generator 1"1/2 Gas F
(13) 2 Connection for instrumentation 1/2" Gas F
3 Heating return/To Generator 1"1/2 Gas F
4 Connection for instrumentation 1/2" Gas F
5 Connection for instrumentation 1/2" Gas F
H9 (15) 6
H7 (10)(11)(12) Heating return / To Generator / Heating delivery
7
H6 (9) 8 Connection for instrumentation 1/2" Gas F
9 Connection for electrical integration 1"1/2 F
H5 (8)
A

10 Heating delivery/From Generator 1” 1/2 Gas F


H4 (6)(7) 11 Connection for instrumentation 1/2" Gas F
H

H8 (14) H3 (5) 12
Heating delivery/From Generator 1” 1/2 Gas F
13
14 Primary circuit outlet from MACS®
H2 (4) 15 Primary circuit inlet from MACS®
16 Heat exchanger outlet
17 Heat exchanger inlet
H1 (1)(2)(3)

0
Domestic Hot Water station MACS® by Cordivari has been designed to
combine benefits from storage heating water with the comfort and safety

BUFFER TANKS
of immediate production of DHW.

(16) (17)

Plate heat
Primary exchangers
circuit
(1) (6) (3) (7) (12)
(10)

(14) (15)
Sanitary
(2) (4) (5) (9) circuit
(8) (11)

120 Kw 70 Kw
400 340
H11 (17)
400
620
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

H10 (16) A.C.S.

0
A.C.S.

Capacity Df De H A H1 H2 H3 H4 H5 H6 H7 H8 H9 14 - 15 H10 H11 16 - 17

[liters] [mm] Gas M [mm] Gas F

500 650 850 1720 1747 270 545 820 770 1095 1233 1370 670 1370 3/4" 270 990 1"

800 790 990 1908 1946 308 612 916 924 1220 1372 1524 824 1524 3/4" 308 938 1"1/4

1000 790 990 2198 2231 308 646 983 1094 1321 1489 1658 1057 1863 1" 308 1078 1"1/4

1500 950 1150 2301 2346 336 711 1086 1236 1461 1649 1836 1085 1891 1" 336 1106 1"1/4

51
COMMUNICATING BUFFER
HEATING WATER COMMUNICATING BUFFER TANK

Heat
Capacity COMMUNICATING BUFFER
exchanger surface
[liters] ART. NR. Price [€] [m2]

800 LEFT 3251162280214 1.210,00 -

800 RIGHT 3251162280204 1.210,00 -

800 RIGHT WITH EXCHANGER 3251162280104 1.461,00 2,5

1000 LEFT 3251162280215 1.320,00 -

1000 RIGHT 3251162280205 1.320,00 -

1000 RIGHT WITH EXCHANGER 3251162280105 1.637,00 3

BUFFER CONNECTING KIT


ART. NR. Pieces Capacity [liters] Price [€]
STORAGE EXCHANGER
5221000000023 3 800 80,00
Pmax Tmax Pmax Tmax
3 bar 95° C 12 bar 99° C 5221000000024 4 1000 107,00

In the system with biomass generators, the thermal accumulation (buffer) is very useful, because it New Communicating Buffer are the ideal solution for installation where there is a need of big
allows a regular operation of the boiler, and avoid interruptions due to the insufficient energy request thermal accumulation volume in small technician room.
from the heating installation. The communicating buffer Cordivari have adjustable foot support to facilitate the alignment during
The Cordivari buffer improves the operating comfort and gives to the system the same operating the installation, a complete range, with possibility to integrate a solar energy.
fluency as automatic gas/gas oil systems.

1000 liters 800 liters

With heat exchanger With heat exchanger

Technical descriptions Application Heat exchanger:


Production and storage of central heating water. Ideally Storage of heating hot water. They are mainly used to Carbon steel coil
suited to biomass boilers operating in conjunction with improve reaction flexibility of stoves, burners, or in low
solar thermal systems. The buffer storage capacity water contents systems. Warranty
facilitates the smooth running of the biomass boiler 2 years
even when there is insufficient energy usage in the Insulation See general sales conditions and warranty
building. 100 mm soft foam polyurethane thermal conductivity
The biomass boiler can also be limited in output capacity 0. 038W/mk. Adjustable Supporting feet.
and the results willbe similar to the performance which
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

is achieved with oil or gas boilers. External lining


There is no need of any anti-corrosion treatment due to SCAY grey RAL 9006 , top cover and PVC flange cover.
the fact that the buffer is in a closed circuit without any
adding air.

Capacity H A H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11 3-8


COMMUNICATING BUFFER
[lt] [mm]
800 LEFT 1908 1950 308 612 924 916 - 924 1220 - 1372 1524 1524 -
800 RIGHT 1908 1950 308 612 924 916 - 924 1220 - 1372 1524 1524 -
800 RIGHT WITH EXCHANGER 1908 1950 308 612 924 916 938 924 1220 - 1372 1524 1524 1"1/4

1000 LEFT 2198 2235 308 646 815 983 - 1094 1321 1321 1489 1658 1828 -
1000 RIGHT 2198 2235 308 646 815 983 - 1094 1321 1321 1489 1658 1828 -
1000 RIGHT WITH EXCHANGER 2198 2235 308 646 815 983 1078 1094 1321 1321 1489 1658 1828 1"1/4

52
(Note: Technical draws are referred to 1000 liters capacity models) CONNECTIONS
1 Preset link for couplings ø 76,1-75
2 Connection for instrumentation 1/2"Gas F
3 Heat exchanger outlet
4-9 Heating return/To Generator 1” 1/2 Gas F
5 Connection for instrumentation 1/2"Gas F
6 Preset link for couplings ø 76,1-75
7 Connection for instrumentation 1/2"Gas F
8 Heat exchanger inlet
10 Connection for instrumentation 1/2"Gas F
11 Preset link for couplings ø 76,1-75
12 Connection for electrical integration 1"1/2 Gas F
13 Connection for instrumentation 1/2"Gas F
14-16 Heating delivery/From Generator 1” 1/2 Gas F
15 Preset link for couplings ø 76,1-75

Ø 990 Ø 990
Ø 790 Ø 790
(16) (16)

H11 (15) H11 (15)

H10 (14) (13) H10 (13) (14)

H9 (12) H9 (12)

H8 (11) H8 (11)
A

A
H7 (10) H7 (10)
H6 (9) H6 (9)

BUFFER TANKS
H

H
H4 (7) H4 (7)

H3 (6) H3 (6)

H2 (5) H2 (5)

H1 H1
(4) (2) (1) (1) (2) (4)

0 0

Ø 990 Ø 990
Ø 790 Ø 790
(16) (16)

H11 (15) H11 (15)

H10 (14) (13) H10 (13) (14)

H9 (12) H9 (12)

H8 (11) H8 (11)
A

H7 (10) H7 (10)
H

H6 (9) H5 (8) H5 (8) H6 (9) H5 (8)


H4 (7) H4 (7)

H3 (6) H3 (6)

H2 (5) H2 (5)

H1 H1
(4) (2) (1) (1) (2) (4) H1 (3)

0 0 0

(16) (16)
(1)(6)(11)(15) (1)(6)(11)(15)

(2)(5)(7)(10)(13) (2)(5)(7)(10)(13)

(3)(8) (12)
(4) (12) (4)
(9)(14) (9)(14)

53
TERM. COMBI1 XC/WC
MULTI-HEAT ENERGY BUFFER WITH TANK IN TANK CALORIFIER - COMBI 1

Net volume DHW DHW


Capacity TERM. COMBI1 XC TERM. COMBI1 WC Weight
storage (V1) volume (V2) surface (V2)
2
[liters] ART. NR. Price [€] ART. NR. Price [€] [liters] [liters] [m ] [Kg]

570 3270162283051 2.285,00 3270162283001 1.533,00 406 146 1,3 109


800 3270162283052 2.681,00 3270162283002 1.736,00 602 191 1,6 133
1000 3270162283053 2.936,00 3270162283003 1.837,00 706 226 1,8 150
1500 -- -- 3270162283004 2.401,00 984 412 2,5 228
2000 -- -- 3270162283005 2.991,00 1380 566 3,1 290
PROMPT DELIVERY
Grey highlighted products are
dispatched in 1-5 working days.
(Delivery time excluded)

Stainless Steel 316L Polywarm®

BUFFER TANK D.H.W. TANK (V2) D.H.W. TANK (V2)


Pmax Tmax Pmax Tmax Pmax Tmax
3 bar 99° C 6 bar 95°C 6 bar 90°C

Note: During installation always take care to fill first tank V2 (DHW) before tank V1 (Buffer).
In working operating condition avoid that the pressure of the buffer exceed the one of the DHW more than 1,5 bar.
CONNECTIONS

1
De Heating return/To Generator 1” 1/2 Gas F
Df 2

3
5 Connection for instrumentation 1/2” Gas F

H13 (15) (16) 6


8 Connection for electrical integration 2” Gas F
(22)
10 Connection for instrumentation 1/2” Gas F
H11 (13)
H10 (12) 11
H9 (10) Heating return/To Generator / Heating delivery
12
13 Connection for instrumentation 1/2” Gas F
H

H7 (11)
H6 (8) 15
Heating delivery / From Generator 1” 1/2 Gas F
A

16
H4 (6)
17 Air Ventil 1/2” Gas F
H3 (5)
(20)
(18) 18 Domestic Cold Water Circuit Inlet 3/4” Gas F
H2 (3) (17)
(15) (11) (1) (16) (12) (2)
(22) 19 Domestic Cold Water Circuit Outlet 3/4” Gas F
H1 (1) (2) (21) (19) 20 Recirculation 3/4" Gas F
21 Connection for instrumentation 1/2” Gas F
0
22 Chain magnesium anode
(13) (10) (8)
(6) (5) (3)
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

Technical descriptions Insulation Warranty


Multi-Heat Energy tanks are used in units with a typically 100 mm soft foam, thermal conductivity 0.038W/mK with SCAI Buffer 2 years
discontinuous energy source for double use: heating system and grey and top cover. DHW Tank (V2) (either Stainless Steel or Polywarm) 5 years
sanitary hot water system. See general sales conditions and warranty
The carbon steel buffer is connected with the heating system and External lining
do not need any corrosion proofing. SCAI grey RAL 9006 and top cover. Cathode protection
The inside sanitary tank can be either Stainless Steel Inox 316L The special shape of the new chain magnesium anode allows to
or Polywarm, both suitable for drinking water according to D. M. Heat exchanger check the real consumption of the magnesium bar also in low ceiling
n.174 del 06.04.04 1 DHW Polywarm® coated inner tank. technician rooms.

Application
Production and Storage of hot water (heating) and sanitary water.
Used to improve flexibility of pellets, stoves and burners.

Capacity Df De H A H1 H2 H3 H4 H6 H7 H9 H10 H11 H13

[liters] [mm]
570 650 850 1910 1957 220 445 603 760 920 1035 1225 1260 1420 1610
800 790 990 1880 1944 238 463 581 698 838 944 1078 1160 1278 1558
1000 790 990 2170 2226 228 463 621 778 963 1084 1388 1420 1638 1838
1500 950 1150 2260 2332 276 511 724 936 1056 1164 1436 1498 1686 1886
2000 1100 1300 2360 2448 321 546 724 901 1071 1185 1471 1533 1721 1951

54
TERM. COMBI2 XC /WC
MULTI-HEAT ENERGY BUFFER WITH 1 FIX COIL AND TANK IN TANK CALORIFIER - COMBI 2

Net volume DHW DHW


Lower fix coil Lower fix coil
Capacity TERM. COMBI2 XC TERM. COMBI2 WC storage volume surface Weight
volume surface
(V1) (V2) (V2)

[liters] ART. NR. Price [€] ART. NR. Price [€] [liters] [liters] [m2] [liters] [m2] [Kg]

570 3270162283151 2.499,00 3270162283101 1.633,00 388 146 1,3 18 2,8 131
800 3270162283152 2.949,00 3270162283102 1.931,00 582 191 1,6 20 3,1 160
1000 3270162283153 3.065,00 3270162283103 2.160,00 681 226 1,8 24 3,7 184
1500 -- -- 3270162283104 2.770,00 952 412 2,5 32 4,9 267
2000 -- -- 3270162283105 3.495,00 1345 566 3,1 35 5,4 336

PROMPT DELIVERY
Grey highlighted products are
dispatched in 1-5 working days.
(Delivery time excluded)

I
Stainless Steel 316L Polywarm®
SISTEM LARI
ICI SO
Product component of a complete Sun un TERM
BUFFER TANK TANK (V2) TANK (V2) EXCHANGER
Solution Solar Thermal System
Please refer Sun Solution Cordivari Pmax Tmax Pmax Tmax Pmax Tmax Pmax Tmax
0
201
mique
INO

3 bar
LIST

catalogue CAT
ALO
tèmes
GO Ther
s 99° C 6 bar 95°C 6 bar 90°C 12 bar 99°C

Note: During installation always take care to fill first tank V2 (DHW) before tank V1 (Buffer).
In working operating condition avoid that the pressure of the buffer exceed the one of the DHW more than 1,5 bar.
CONNECTIONS

1 Heating return/To Generator 1” 1/2 Gas F

BUFFER TANKS
2 Heat exchanger inlet 1” Gas F De
3 Connection for instrumentation 1/2” Gas F Df

4 Heating return/To Generator 1” 1/2 Gas F

5
Connection for instrumentation 1/2” Gas F
6
H13 (15) (16)
7 Heat exchanger outlet 1” Gas F
8 Connection for electrical integration 2” Gas F
10 Connection for instrumentation 1/2” Gas F H11 (13)
(22) H10 (12)
11 Heating return 1” 1/2 Gas F H9 (10)
12 2nd Generator delivery 1” 1/2 Gas F
13 Connection for instrumentation 1/2” Gas F
H

H7 (11)
15 H6 (8)
H5 (7)
Heating delivery / From Generator 1” 1/2 Gas F A
16 H4 (6)

17 Connection for instrumentation 1/2” Gas F (20) H3 (5)


(18)
(17)
18 Domestic Cold Water Circuit Inlet 3/4” Gas F (15) (11) (1) (16) (12) (2) H2 (3)
(22)
19 Domestic Cold Water Circuit Outlet 3/4” Gas F (21) (19)
H1 (1) (2) (4)
20 Recirculation 3/4” Gas F
(7) (2) 0
21 Connection for instrumentation 1/2” Gas F
(13) (10) (8)
22 Chain magnesium anode (6) (5) (3)
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

Technical descriptions Insulation Cathode protection


Multi-Heat Energy tanks are used in units with a typically 100 mm soft foam polyurethane, thermal conductivity 0.038W/ The special shape of the new chain magnesium anode allows to
discontinuous energy source for double use: heating system and mK. check the real consumption of the magnesium bar also in low ceiling
sanitary hot water system. technician rooms.
The carbon steel buffer is connected with the heating system and External lining
do not need any corrosion proofing. SCAI grey RAL 9006 and top cover. Warranty
The inside sanitary tank can be either Stainless Steel Inox 316L Buffer 2 years
or Polywarm, both suitable for drinking water according to D. M. Heat exchanger V2 Tank (either Stainless Steel or Polywarm) 5 years
n.174 del 06.04.04. 1 DHW Polywarm® coated inner tank. See general sales conditions and warranty
1 fixed coil in carbon steel.
Application
Production and Storage of hot water (heating) and sanitary water.
Used to improve flexibility of pellets, stoves and burners.

Capacity Df De H A H1 H2 H3 H4 H5 H6 H7 H9 H10 H11 H13

[liters] [mm]
570 650 850 1910 1957 220 445 603 760 860 920 1035 1225 1260 1420 1610
800 790 990 1880 1944 238 463 581 698 798 838 944 1078 1160 1278 1558
1000 790 990 2170 2226 228 463 621 778 908 963 1084 1388 1420 1638 1838
1500 950 1150 2260 2332 276 511 724 936 996 1056 1164 1436 1498 1686 1886
2000 1100 1300 2360 2448 321 546 724 901 1001 1071 1185 1471 1533 1721 1951

55
TERM. COMBI3 XC /WC
MULTI-HEAT ENERGY BUFFER WITH 2 FIX COILS AND TANK IN TANK CALORIFIER - COMBI 3

Stainless Steel 316L Polywarm®

BUFFER TANK TANK (V2) TANK (V2) EXCHANGER


Pmax Tmax Pmax Tmax Pmax Tmax Pmax Tmax
3 bar 99° C 6 bar 95°C 6 bar 90°C 12 bar 99°C

Net
DHW DHW Lower Lower Upper Upper
volume
Capacity TERM. COMBI3 XC TERM. COMBI3 WC volume surface fix coil fix coil fix coil fix coil Weight
storage (V2)
(V2) volume surface volume surface
(V1)
[liters] ART. NR. Price [€] ART. NR. Price [€] [liters] [liters] [m2] [liters] [m2] [liters] [m2] [Kg]
570 3270162283251 2.703,00 3270162283201 1.899,00 375 146 1,3 18 2,8 12 1,9 162
800 3270162283252 3.142,00 3270162283202 2.181,00 566 191 1,6 20 3,1 16 2,4 195
1000 3270162283253 3.410,00 3270162283203 2.409,00 661 226 1,8 24 3,7 20 3,1 226
1500 -- -- 3270162283204 3.090,00 929 412 2,5 32 4,9 23 3,5 322
2000 -- -- 3270162283205 3.797,00 1318 566 3,1 35 5,4 27 4,1 397
PROMPT DELIVERY
Grey highlighted products are
dispatched in 1-5 working days.
(Delivery time excluded)

Technical descriptions Insulation Cathode protection


Multi-Heat Energy tanks are used in units with a typically 100 mm soft foam polyurethane, thermal conductivity 0.038W/ The special shape of the new chain magnesium anode allows to
discontinuous energy source for double use: heating system and mK. check the real consumption of the magnesium bar also in low ceiling
sanitary hot water system. technician rooms.
The carbon steel buffer is connected to the heating system and do External lining
not need any corrosion proofing. SCAI grey RAL 9006 and top cover. Warranty
The inside sanitary tank can be either Stainless Steel 316L or Buffer 2 years
Polywarm, both suitable for drinking water according to D. M. Heat exchanger V2 Tank (either Stainless Steel or Polywarm) 5 years
n.174 del 06.04.04. 1 DHW Polywarm® coated inner tank. See general sales conditions and warranty.
2 fixed coils in carbon steel.
Application
Production and Storage of hot water (heating) and sanitary water.
Used to improve flexibility of pellets, stoves and burners.

I
SISTEM LARI
ICI SO
Product component of a complete Sun un TERM

Solution Solar Thermal System


Note: During installation always take care to fill first tank V2 (DHW) before tank V1 (Buffer). Please refer Sun Solution Cordivari 0
201

In working operating condition avoid that the pressure of the buffer exceed the one of the DHW more than 1,5 bar. catalogue CAT
ALO
èmes
GO
LIST
Ther
mique
INO

CONNECTIONSS
De
Df 1 Heating return/To Generator 1” 1/2 Gas F
2 Lower heat exchanger inlet 1” Gas F
3 Connection for instrumentation 1/2” Gas F
4 Heating return/To Generator 1” 1/2 Gas F
H13 (15) (16)
5
H12 (14) Connection for instrumentation 1/2” Gas F
6
(22)
H11 (13)
7 Lower heat exchanger outlet 1” Gas F
H10 (12) 8 Connection for electrical integration 2” Gas F
H9 (10)
9 Upper heat exchanger inlet 1” Gas F
H8 (9) 10 Connection for instrumentation 1/2” Gas F
H

H7 (11)
11 Heating return 1”1/2 Gas F
H6 (8)
H5 (7) 12 2nd Generator delivery 1”1/2 Gas F
(20)
A

H4 (6) (18)
(17) 13 Connection for instrumentation 1/2” Gas F
(15) (11) (1) (16) (14) (12)
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

H3 (5) (22) (9) (4) 14 Upper heat exchange outlet 1” Gas F


(21)
(19) 15
H2 (3)
Heating delivery / From Generator 1” 1/2 Gas F
16
H1 (1) (2) (4) (7) (2)
17 Connection for instrumentation 1/2” Gas F
(13) (10) (8) 18 Domestic Cold Water Circuit Inlet 3/4” Gas F
0 (6) (5) (3)
19 Domestic Cold Water Circuit Outlet 3/4” Gas F
20 Recirculation 3/4” Gas F
21 Connection for instrumentation 1/2” Gas F
22 Chain magnesium anode

Capacity Df De H A H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11 H12 H13

[liters] [mm]
570 650 850 1910 1957 220 445 603 760 860 920 1035 1020 1225 1260 1420 1460 1610
800 790 990 1880 1944 238 463 581 698 798 838 944 958 1078 1160 1278 1398 1558
1000 790 990 2170 2226 228 463 621 778 908 963 1084 1118 1388 1420 1638 1678 1838
1500 950 1150 2260 2332 276 511 724 936 996 1056 1164 1206 1436 1498 1686 1726 1886
2000 1100 1300 2360 2448 321 546 724 901 1001 1071 1185 1241 1471 1533 1721 1761 1951

56
COMBI 1 - 2 - 3 D.H.W. HEAT EXCHANGER TECHNICAL PERFORMANCES

COMPLETE HEATED STORAGE VOLUME UPPER PART HEATED STORAGE VOLUME

Max sanitary water Max sanitary water Max sanitary water Max sanitary water
Sanitary
DHW exchanger produced from 10° to 45° produced from 10° to 45° produced from 10° to 45° produced from 10° to 45°
Capacity Circuit DHW volume
surface with storage at 65° and with storage at 65° and with storage at 65° and with storage at 65° and
Volume
boiler on boiler off boiler on boiler off

[lt] [lt] [lt] [m2] [lt/min] [lt] [lt/min] [lt]

10 lt/min: 239 lt 10 lt/min: 179 lt


570 406 146 1,3 3,0 1,86
25 lt/min: 213 lt 25 lt/min: 160 lt
10 lt/min: 320 lt 10 lt/min: 240 lt
800 602 191 1,6 3,5 2,17
25 lt/min: 280 lt 25 lt/min: 210 lt
10 lt/min: 389 lt 10 lt/min: 291 lt
1000 706 226 1,8 4,1 2,26
25 lt/min: 330 lt 25 lt/min: 250 lt
10 lt/min: 753 lt 10 lt/min: 565 lt
1500 984 412 2,5 5,6 3,36
25 lt/min: 614 lt 25 lt/min: 461 lt
10 lt/min: 1083 lt 10 lt/min: 812 lt
2000 1380 566 3,1 6,8 4,08
25 lt/min: 852 lt 25 lt/min: 639 lt

POWERS OF FIXED HEAT EXCHANGERS FOR COMBI 2 AND COMBI 3

Output of the lower heat exchangers Combi 2 and 3 depending on the average DeltaT between primary and accumulation considering (considering flow rate at 3 m3/h)

120 Thermal output is given in both KW or kcal/h in terms of average temperature


100000 difference between primary and secondary circuit, all for a range of primary 3

BUFFER TANKS
m3/h. For example, a Combi2 of 1000 liters Capacity with a water flow of 3 m3/h
2000
100 at 80 ° C inlet and outlet at 70 ° C, has on the storage of water an average
1500
80000
temperature of 60 °, the mean difference of temperature will be (80 +70) / 20-60
= 15 ° and therefore you can exchange up to approximately 32 KW.
80
1000
in KCal/h
in KW

Output [KCal/h]

60000
Output [Kw]

800
60
Potenza

Potenza

570

40000
40

20000
20

0 0
0 5 10 15 20 25 30 35
Delta T medio
Average Delta T°C
[°C]

Output of the upper heat exchangers Combi 3 depending on the average Delta T between primary and accumulation (considering flow rate at 3 m3/h)

120
100000

100

80000

2000
80
in KCal/h
in KW

1500
Output [KCal/h]

60000
Output [Kw]

60 1000
Potenza

Potenza

800
40000
40 570

20000
20

0 0
0 5 10 15 20 25 30 35
Delta T medio
Average Delta T°C
[°C]

57
ECO-COMBI 1
MULTI-HEAT ENERGY BUFFER ECO-COMBI 1 WITH STAINLESS STEEL 316 L SANITARY WATER CORRUGATED PIPE

Net volume DHW DHW corrugated pipe


Capacity ECO-COMBI 1 Weight
storage volume surface
2
[liters] ART. NR. Price [€] [lt] [lt] [m ] [Kg]

570 3270162282201 2.097,00 527 31 5,3 95


800 3270162282202 2.458,00 770 33,4 5,8 116
1000 3270162282203 2.919,00 897 45,5 7,8 167
1250 3270162282204 3.143,00 1200 45,5 7,8 180
1500 3270162282205 3.547,00 1372 55,3 9,5 235
2000 3270162282206 4.444,00 1885 72,2 12,3 343

BUFFER CORRUGATED D.H.W. STAINLESS STEEL PIPE


Pmax Tmax Pmax

3 bar 99° C 6 bar

Technical descriptions suitable for drinking water in accordance with D.M. n.174 del
Multi-Heat Energy tanks are used in units with a typically 06.04.04 Insulation
discontinuous energy source for double use: heating system and The particular shape of the internal exchanger is avoiding any 100 mm soft foam polyurethane , thermal conductivity 0.038W/
sanitary hot water system. Eco Combi 1 can be used in problem relating to the storage of sanitary hot water (less, mK.
stagnation,bacterium etc ) and ensure high heating exchange
•Heating system with a biomass generator as energy source , performances. External lining
combining the possibility to produce hot water for sanitary use. In fact , as the internal exchanger is made by a continuous SCAI grey RAL 9006 . Top and flange cover.
In such case , storage heating volume allows the generator to conduction of spiral pipes , the renewed water is ensured on each
regularly work , limiting number of stops due to the inadeguate delivery. Heat exchangers:
energy request of the heating system. Moreover, it limits the 1 D.H.W. corrugated coil in stainless steel 316L.
emission of smoke and the creation of corrosive condensate Application
(smokes side), being a thermal range that will increase the Production and Storage of hot water (heating) istant production Warranty
working comfort results. of sanitary water. Used to improve reaction flexibility of pellets, Buffer 2 years
• Sanitary hot water production systems for domestic and sanitary stoves and burners. Stainless steel coil : 5 Years
use where heating water is stored. In this system , the high See general sales terms and conditions
potentiality of the Eco Combi allows to obtain a good production Material
of hot sanitary water even if temperatures of the primary system Buffer in carbon steel , raw inside, painted outside . Accessories for circulation kit are available – see page 74
are not so high (i.e using heating pumps as primary source and D.H.W. corrugated coil in stainless steel 316L.
solar source as support)
Being connected to the heating system the buffer tank doesn’t
need any anti-corrosion treatment, therefore it is in carbon steel,
the internal corrugated coil is in stainless steel 316L and it is

De
Df
(14)

CONNECTIONS
1 Domestic Cold Water Circuit Inlet 1” Gas M
H14 (11) (13)
H13 (10) 2 Heating return/To Generator 1”1/2 Gas F

3 Connection for instrumentation 1/2” Gas F


H11 (12)
4 Heating return/To Generator 1”1/2 Gas F
H10 (6) (8)
H9 (9) 5 Connection for instrumentation 1/2” Gas F
H7 (7)
H

Heating return/To Generator / Heating delivery


6-8
1”1/2 Gas F
A

H5 (5) 7 Connection for electrical integration 2” Gas F


P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

9 Connection for instrumentation 1/2” Gas F


H4 (15) (2) (6) (4) (8) 10 Domestic Hot Water Circuit Outlet 1” Gas M
(1)(10) (11) (14) (13)
11 Heating delivery/From Generator 1”1/2 Gas F
H3 (2) (3) (4)
H1 (1) 12 Connection for instrumentation 1/2” Gas F
13
Heating delivery/From Generator 1”1/2 Gas F
0 (3) (5) (7) 14
(9) (12) (15) 15 Connection for instrumentation 1/2” Gas F

Capacity Df De H A H1 H3 H4 H5 H7 H9 H10 H11 H13 H14

[liters] [mm]
570 650 850 1920 1945 230 350 505 660 1045 1170 1211 1320 1470 1600
800 790 990 1890 1930 248 378 533 688 918 1038 1110 1238 1398 1518
1000 790 990 2180 2210 248 388 608 828 1098 1288 1350 1538 1698 1808
1250 900 1100 2252 2292 297 437 656 876 1146 1336 1405 1606 1751 1856
1500 950 1150 2300 2345 296 456 676 896 1196 1386 1455 1611 1776 1886
2000 1100 1300 2372 2430 330 500 720 940 1230 1420 1489 1645 1810 1920

58
ECO-COMBI 2
MULTI-HEAT ENERGY BUFFER ECO-COMBI 2 WITH 1 FIX COILS AND STAINLESS STEEL 316 L D.H.W. CORRUGATED PIPE

Net volume DHW DHW Corrugated Fix coil Fix coil


Capacity ECO-COMBI 2 Weight
storage (V1) volume (V2) pipe surface volume surface
2 2
[liters] ART. NR. Price [€] [lt] [lt] [m ] [lt] [m ] [Kg]

570 3270162282211 2.325,00 511 31 5,3 13 2 118


800 3270162282212 2.649,00 750 33,4 5,8 16,3 2,5 142
1000 3270162282213 3.098,00 872 45,5 7,8 20,7 3,1 202
1250 3270162282214 3.367,00 1174 45,5 7,8 20,7 3,1 216
1500 3270162282215 3.794,00 1341 55,3 9,5 25,3 3,8 278
2000 3270162282216 4.602,00 1848 72,2 12,3 29,6 4,5 394

PROMPT DELIVERY BUFFER D.H.W. CORRUGATED STAINLESS STEEL PIPE FIX COIL
Grey highlighted products are
dispatched in 1-5 working days. Pmax Tmax Pmax Pmax Tmax
(Delivery time excluded) 3 bar 99° C 6 bar 12 bar 99°C

Technical descriptions carbon steel, the internal corrugated coil is in stainless steel Insulation
Multi-Heat Energy tanks are used in units with a typically 316L and it is suitable for drinking water in accordance with D.M. 100 mm soft foam polyurethane , thermal conductivity 0.038W/
discontinuous energy source for double use: heating system and n.174 del 06.04.04 mK.
sanitary hot water system. Eco Combi 1 can be used in The particular shape of the internal exchanger is avoiding any
problem relating to the storage of sanitary hot water (less, External lining
•Heating system with a biomass generator as energy source , stagnation,bacterium etc ) and ensure high heating exchange SCAI grey RAL 9006. Top and flange cover.
combining the possibility to produce hot water for sanitary use. performances.
In such case , storage heating volume allows the generator to In fact , as the internal exchanger is made by a continuous Heat exchangers:
regularly work , limiting number of stops due to the inadeguate conduction of spiral pipes , the renewed water is ensured on each - 1 carbon steel fix coil for primary water.
energy request of the heating system. Moreover, limiting the sanitary hot water delivery. - 1 D.H.W. corrugated coil in stainless steel 316L.
emission of the grade of smoke and the creation of corrosive
condensate (smokes side), it becomes a thermal range that will Application Warranty
increase the working comfort results. Production and storage of sanitary heating hot water. Buffer: 2 years

BUFFER TANKS
• Sanitary hot water production systems for domestic and sanitary Instant production of DHW. Stainless steel coil : 5 years
use where heating water is stored. In this system , the high They are mainly used to improve reaction flexibility of stoves, See general sales terms and conditions
potentiality of the Eco Combi allows to obtain a good production burner and woodstoves.
of hot sanitary water even if temperatures of the primary system Accessories for circulation kit are available – see page 74
are not so high (i.e using heating pumps as primary source and Material
solar source as support) Buffer in carbon steel , raw inside, painted outside .
Being connected to the heating system the accumulation tank DHW corrugated coil in stainless steel 316L.
doesn’t need any anti-corrosion treatment, therefore it is in

I
SISTEM LARI
Product component of a complete Sun un TERM
ICI SO De
Solution Solar Thermal System Df
Please refer Sun Solution Cordivari
LIST mique
INO
201
0
(14)
catalogue CAT
ALO
èmes
GO Ther

CONNECTIONS NS
1 Domestic Cold Water Circuit Inlet 1" Gas M
H14 (11) (13)
2 Heating return/To Generator 1"1/2 Gas F H13 (10)
3 Connection for instrumentation 1/2” Gas F H11 (12)
4 Heating return/To Generator 1"1/2 Gas F
5 Connection for instrumentation 1/2” Gas F H10 (6) (8)
Heating return / To Generator H9 (9)
6-8
/ Heating delivery 1”1/2 Gas F H7 (7)
H

7 Connection for electrical integration 2” Gas F


9 Connection for instrumentation 1/2” Gas F H6 (16)
A

10 Domestic Hot Water Circuit Outlet 1" Gas M H5 (5)


P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

11 Heating delivery/From Generator 1”1/2 Gas F


H4 (17) (1) (2) (6) (14) (4) (8) (13)
12 Connection for instrumentation 1/2” Gas F (10) (11) (15) (16)
13 H3 (2) (3) (4)
Heating delivery / From Generator 1”1/2 Gas F
14 H2 (15)
H1 (1)
15 Heat exchanger inlet 1" Gas F
16 Heat exchanger outlet 1" Gas F
17 Connection for instrumentation 1/2” Gas F 0 (3) (5) (7)
(9) (12) (17)

Capacity Df De H A H1 H2 H3 H4 H5 H6 H7 H9 H10 H11 H13 H14

[liters] [mm]
570 650 850 1920 1945 230 247 350 505 660 720 1045 1170 1211 1320 1470 1600
800 790 990 1890 1930 248 278 378 533 688 751 918 1038 1110 1238 1398 1518
1000 790 990 2180 2210 248 288 388 608 828 890 1098 1288 1350 1538 1698 1808
1250 900 1100 2252 2292 297 336 437 656 876 938 1146 1336 1405 1606 1751 1856
1500 950 1150 2300 2345 296 356 456 676 896 958 1196 1386 1455 1611 1776 1886
2000 1100 1300 2372 2430 330 400 500 720 940 1003 1230 1420 1489 1645 1810 1920

59
ECO-COMBI 3
MULTI-HEAT ENERGY BUFFER ECO-COMBI 3 WITH 2 FIX COILS AND STAINLESS STEEL 316 L D.H.W. CORRUGATED PIPE

DHW
Net volume DHW Lower Lower Upper Upper
Capacity ECO-COMBI 3 Corrugated Weight
storage (V1) volume (V2) Fix coil volume Fix coil surface Fix coil volume Fix coil surface
pipe surface
[liters] ART. NR. Price [€] [lt] [lt] [m2] [lt] [m2] [lt] [m2] [Kg]

570 3270162282221 2.481,00 503 31 5,3 13 2 8 1,25 132


800 3270162282222 2.812,00 738 33,4 5,8 16,3 2,5 11,8 1,8 165
1000 3270162282223 3.233,00 855 45,5 7,8 20,7 3,1 16,3 2,5 231
1250 3270162282224 3.579,00 1131 45,5 7,8 20,7 3,1 16,3 2,5 244
1500 3270162282225 4.036,00 1324 55,3 9,5 25,3 3,8 16,8 2,8 307
2000 3270162282226 4.800,00 1829 72,2 12,3 29,6 4,5 19,1 2,8 427

D.H.W. CORRUGATED PROMPT DELIVERY


BUFFER FIX COIL
STAINLESS STEEL PIPE Grey highlighted products are
Pmax Tmax Pmax Pmax Tmax dispatched in 1-5 working days.
3 bar 99° C 6 bar 12 bar 99°C (Delivery time excluded)

Technical descriptions doesn’t need any anti-corrosion treatment, therefore it is in Insulation


Multi-Heat Energy tanks are used in units with a typically carbon steel, the internal corrugated coil is in stainless steel 100 mm soft foam polyurethane, thermal conductivity 0.038W/
discontinuous energy source for double use: heating system and 316L and it is suitable for drinking water in accordance with D.M. mK.
sanitary hot water system. Eco Combi 1 can be used in n.174 del 06.04.04
The particular shape of the internal exchanger is avoiding any External lining
•Heating system with a biomass generator as energy source , problem relating to the storage of sanitary hot water (less, SCAI grey RAL 9006 . Top and flange cover
combining the possibility to produce hot water for sanitary use. stagnation,bacterium etc ) and ensure high heating exchange
In such case , storage heating volume allows the generator to performances. Heat exchangers:
regularly work , limiting number of stops due to the inadeguate In fact , as the internal exchanger is made by a continuous - 2 coils in carbon steel for primary water.
energy request of the heating system. Moreover, limiting the conduction of spiral pipes , the renewed water is ensured on each - 1 D.H.W. corrugated coil in stainless steel 316L.
emission of the grade of smoke and the creation of corrosive sanitary hot water delivery.
condensate (smokes side), it becomes a thermal range that will Warranty
increase the working comfort results. Application Buffer 2 years
Production and storage of sanitary heating hot water. Stainless steel coil : 5 years
• Sanitary hot water production systems for domestic and sanitary Instant production of DHW. See general sales terms and conditions
use where heating water is stored. In this system , the high They are mainly used to improve reaction flexibility of stoves,
potentiality of the Eco Combi allows to obtain a good production burner and woodstoves. Accessories for circulation kit are available – see page 74
of hot sanitary water even if temperatures of the primary system
are not so high (i.e using heating pumps as primary source and Material
solar source as support) Buffer in carbon steel , raw inside, painted outside .
Being connected to the heating system the accumulation tank DHW corrugated coil in stainless steel 316L.

I
SISTEM LARI
ICI SO
Product component of a complete Sun un TERM

Solution Solar Thermal System


De Please refer Sun Solution Cordivari 201
0
LIST mique
INO

Df catalogue èmes
CAT
ALO
GO Ther

(14)
CONNECTIONSS
1 Domestic Cold Water Circuit Inlet 1" Gas M

2 Heating return/To Generator 1"1/2 Gas F


H14 (11) (13)
H13 (10) 3 Connection for instrumentation 1/2” Gas F
H12 (18) 4 Heating return/To Generator 1”1/2 Gas F
H11 (12)
5 Connection for instrumentation 1/2” Gas F
H10 (6) (8)
Heating return/To Generator
H9 (9) 6-8
/ Heating delivery 1”1/2 Gas F
H7 (7) H8 (17) 7 Connection for electrical integration 2” Gas F
9 Connection for instrumentation 1/2” Gas F
H

10 Domestic Hot Water Circuit Outlet 1" Gas M


H6 (16)
A

H5 (5) 11 Heating delivery/From Generator 1”1/2 Gas F


P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

H4 (19) 12 Connection for instrumentation 1/2” Gas F


(1) (2) (6) (4) (8) (13) (15) 13
(10) (11) (16) (17) (18) Heating delivery/From Generator 1”1/2 Gas F
(14) 14
H3 (2) (3) (4)
H2 (15) 15 Heat exchanger inlet 1" Gas F
H1 (1)
16 Heat exchanger outlet 1" Gas F
17 Upper heat exchanger inlet 1" Gas F
0 18 Upper heat exchanger outlet 1" Gas F
(3) (7) (5) 19 Connection for instrumentation 1/2” Gas F
(9) (12) (19)

Capacity Df De H A H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11 H12 H13 H14

[liters] [mm]
570 650 850 1920 1945 230 247 350 505 660 720 1045 1060 1170 1211 1320 1361 1470 1600
800 790 990 1890 1930 248 278 378 533 688 751 918 938 1038 1110 1238 1282 1398 1518
1000 790 990 2180 2210 248 288 388 608 828 890 1098 1113 1288 1350 1538 1586 1698 1808
1250 900 1100 2252 2292 297 336 437 656 876 938 1146 1168 1336 1405 1606 1641 1751 1856
1500 950 1150 2300 2345 296 356 456 676 896 958 1196 1261 1386 1455 1611 1648 1776 1886
2000 1100 1300 2372 2430 330 400 500 720 940 1003 1230 1295 1420 1489 1645 1682 1810 1920

60
ECO-COMBI 1 - 2 - 3 D.H.W. HEAT EXCHANGER TECHNICAL PERFORMANCES

COMPLETE HEATED STORAGE VOLUME UPPER PART HEATED STORAGE VOLUME

Max sanitary water Max sanitary water Max sanitary water Max sanitary water
Sanitary
DHW corrugated produced from 10° to 45° produced from 10° to 45° produced from 10° to 45° produced from 10° to 45°
Capacity Circuit DHW volume
pipe surface with storage at 65° and with storage at 65° and with storage at 65° and with storage at 65° and
Volume
boiler on boiler off boiler on boiler off

[lt] [lt] [lt] [m2] [lt/min] [lt] [lt/min] [lt]

10 lt/min: 400 lt 10 lt/min: 115 lt


570 503 31 5,3 34 18
25 lt/min: 257 lt 25 lt/min: 85 lt
10 lt/min: 587 lt 10 lt/min: 218 lt
800 738 33,4 5,8 37 23
25 lt/min: 377 lt 25 lt/min: 160 lt
10 lt/min: 800 lt 10 lt/min: 294 lt
1000 855 45,5 7,8 50 27
25 lt/min: 541 lt 25 lt/min: 216 lt
10 lt/min: 922 lt 10 lt/min: 310 lt
1250 1131 45,5 7,8 50 28
25 lt/min: 592 lt 25 lt/min: 230 lt
10 lt/min: 1194 lt 10 lt/min: 345 lt
1500 1324 55,3 9,5 57 34
25 lt/min: 735 lt 25 lt/min: 258 lt
10 lt/min: 1657 lt 10 lt/min: 463 lt
2000 1829 72,2 12,3 74 44
25 lt/min: 1142 lt 25 lt/min: 340 lt

POWERS OF FIXED HEAT EXCHANGER FOR ECO-COMBI 2 AND ECO-COMBI 3


Output of the lower heat exchangers EcoCombi 2 and 3 depending on the average DeltaT between primary and accumulation (considering flow rate at 3 m3/h)
120

BUFFER TANKS
100000 Thermal exchangeable powers are given in both KW or kcal/h in terms of average
temperature difference between primary and secondary circuit, all for a range of
100
primary 3 m3/h. For example, a Eco Combi2 of 1000 liters Capacity with a water
2000
flow of 3 m3/h at 80 ° C inlet and outlet at 70 ° C, has on the storage of water an
80000
average temperature of 60 °, the mean difference of temperature will be (80 +70)
/ 20-60 = 15 ° and therefore you can exchange up to approximately 29,9 KW.
80
1500
KCal/h
[KCal/h]
KW

60000
[Kw]
Outputin

1000-1250
Outputin

60
Potenza

Potenza

800
40000
40 570

20000
20

0 0
0 5 10 15 20 25 30 35
Delta T Delta
Average medioT °C
[°C]

Output of the upper heat exchangers Eco Combi 3 depending on the average Delta T between primary and accumulation (considering flow rate at 3 m3/h)
60
50000
1500-2000

50
1000-1250
40000

40
KCal/h
[KCal/h]
KW

800 30000
[Kw]
Outputin

Outputin

30
Potenza

Potenza

570
20000
20

10000
10

0 0
0 5 10 15 20 25 30 35
Average
Delta Delta°C
T medio T [°C]

61
ECO-COMBI 2 DOMUS
MULTI-HEAT ENERGY BUFFER WITH 1 FIX COIL AND 1 STAINLESS STEEL 316L SANITARY WATER CORRUGATED PIPE

Solar DHW Heat Continous production Continous production


Maximum solar
Capacity ECO-COMBI DOMUS exchanger exchanger of DHW 10/45°C with of DHW 10/45°C with Weight
panels surface
surface surface storage at 60°C storage at 50°C
[liters] ART. NR. Price [€] [m2] [m2] [m2] [lt/min.] [lt/min.] [Kg]

200 3270162282501 1.755,00 1 1,4 5 11 8 118


300 3270162282502 2.007,00 1,2 2,5 6 23 16 142
500 3270162282503 2.478,00 2 3,5 10 38 26 202

BUFFER TANK DHW CORRUGATED STAINLESS STEEL PIPE FIX COIL


Pmax Tmax Pmax Pmax Tmax
3 bar 99° C 6 bar 12 bar 99°C

Technical descriptions • Sanitary hot water production systems for domestic and Insulation
Eco Combi Domus range has been developed to satisfy combined sanitary use where only the heating water is stored supplied by 70 mm hard foam polyurethane, thermal conductivity 0.038W/
solar system needs for medium and small areas. two energy sources . mK.
Application suggested for: In this system, the high performance of the sanitary exchanger
• Combined heating and sanitary hot water system with two allows to obtain good production of hot sanitary water even External lining
Energy sources (i.e. a biomass generator with thermal solar) with low temperatures of the primary system (i.e using heating SCAI grey RAL 9006 . Top and flange cover.
hydraulically separated and with the possibility to produce hot pumps)
water for sanitary use . Heat exchangers:
In this case the storage heating volume allows the generator Application - 1 fixed coil in carbon steel for primary water.
to regularly work, limiting number of interruption due to the Production and storage of sanitary heating hot water. - 1 D.H.W. corrugated coil in stainless steel 316L.
inadeguate energy request of the heating system, limiting also Instant production of DHW.
the smoking issues and corrosive condensation of smoking side. They are mainly used to improve reaction flexibility of stoves, Warranty
• Combined heating and hot sanitary water systems , where you burner and woodstoves. Buffer 2 years
want to install a solar panel on traditional heating system: the Stainless steel coil : 5 years
heating can be managed with “ increasing backflow temperature” Material See general sales terms and conditions.
and the production of hot sanitary water can be supported by the - Buffer in carbon steel , raw inside, painted outside .
instantaneous boiler. - DHW corrugated coil in stainless steel 316L.

CONNECTIONS
1 Domestic Cold Water Circuit Inlet 1/2" Gas F
2-5 Heating return/To Generator 1"1/2 Gas F
3 Connection for instrumentation 1/2” Gas F
4 Heat exchanger outlet 1" Gas F
De 6 Connection for instrumentation 1/2” Gas F
Df 7 Heating return/To Generator
(16) 8 / Heating delivery 1"1/2 Gas F
9 Heat exchanger inlet 1" Gas F
10 Connection for instrumentation 1/2” Gas F
11 Connection for electrical integration 1"1/2 Gas F
H9 (12)(13) H10 (14)(15)
12
Heating delivery/From Generator 1"1/2 Gas F
13
14 Connection for instrumentation 1/2” Gas F
H8 (11) 15 Domestic Hot Water Circuit Outlet 1/2" Gas F
H6 (9) H7 (10)
16 Heating delivery/From Generator 1"1/2 Gas F
H5 (8)
H

H4 (7)
A

H3 (6)

(16)
(5)(7)(12) (2)(8)(13)
H2 (5)(4)(3)(2) H1 (1)

0
(4)(9) (1)(11)(15)

(3)(6)(10)(14)

Capacity Df De H A H1 H2 H3 H4 H5 H6 H7 H8 H9 H10

[liters] [mm]
200 450 590 1348 1497 216 241 541 591 691 811 841 811 1041 1068
300 550 690 1390 1579 240 255 555 605 705 795 855 795 1055 1067
500 650 790 1719 1918 250 270 640 770 870 990 1010 1040 1370 1392

62
ECO-COMBI 2 DOMUS INSTALLATION
This layout is used for existing installation as the buffer connection to DHW and the heating systems power control that manage the solar systems and the “ high backflow temperature” through the
are really simple and easy . motorized diverting valve VD1

It simply works and it allows you to use solar energy for DHW production (the wide exchanging area Motorized diverting valve VD2 that handle sanitary water can be managed by a simple thermostat ,
allows to work also with a low Delta T value ) or in case it will not reach the temperature needed, the and to regulate your room temperature you don’t need nothing more than what you normally use ( i.e.
flow is delivered to the burner entrance in order to use solar energy as pre-heating on-off or modulating thermostat the act on the burner )

Furthermore the connection of “high back flow temperature” to the heating systems let you use
Ø 790
solar energy also for room temperature . In this case the heating backflow temperature is compared Ø 650
with the temperature inside the buffer and if this will be higher then heating backflow temperature, Ø 690
3-way bypass valve will work so that the pre-heating water taken from the buffer will come back to Ø 590 Ø 550
Ø 450
the burner

Connecting the heating outlet to the buffer middle connection you can choose to store part or the
energy produced only for sanitary use.

1700
1348

1390

1719
This installation is mainly suitable for heating systems with low backflow temperatures such as low
Delta T radiators, electrical stoves, heating panels

The particular connection of “high backflow temperature”, in case of an high solar energy contribution,
doesn’t allow to take benefit of a condensing boiler. This installation can be regulated with a top

S1

BUFFER TANKS
4

5 2 C
S3

T
VD2
B

LEGEND
A Sanitary water Inlet
VD1 B Sanitary water users
S4 C Heating System
1 Buffer
2 Gas Burner
3 Hydraulic safety group
3 4 Solar panels
A 5 Top solar circulation group
S1, S2, S3, S4 Power probe TOP
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

S2 VD1 Sanitary diverting valve


VD2 Heating diverting valve

ECO-COMBI 2 DOMUS D.H.W. HEAT EXCHANGER TECHNICAL PERFORMANCES


COMPLETE HEATED STORAGE VOLUME UPPER PART HEATED STORAGE VOLUME

Sanitary Max sanitary water produced Max sanitary water Max sanitary water produced Max sanitary water
DHW corrugated
Capacity Circuit from 10° to 45° with storage at produced from 10° to 45° with from 10° to 45° with storage at produced from 10° to 45° with
pipe surface
Volume 65° and boiler on storage at 65° and boiler off 65° and boiler on storage at 65° and boiler off
[lt] [lt] [m2] [lt/min] [lt] [lt/min] [lt]
10 lt/min: 67 lt 10 lt/min: 36 lt
200 2,8778 1,4 12,5 7,5
25 lt/min: 42 lt 25 lt/min: 23 lt
10 lt/min: 115 lt 10 lt/min: 63 lt
300 5,1389 2,5 26,7 16,0
25 lt/min: 65 lt 25 lt/min: 35 lt
10 lt/min: 192 lt 10 lt/min: 105 lt
500 7,1944 3,5 43,7 26,5
25 lt/min: 107 lt 25 lt/min: 58 lt

63
A full range of spare parts and accessories for improving and optimizing Cordivari
products.

HEAT EXCHANGERS

ELECTRONIC DISPLAY

ANODES

INSULATIONS

ELECTRICAL IMMERSIONS

64
ACCESSORIES
ACCESSORIES
CALORIFIERS &
BUFFER TANKS

65
ACCESSORIES FOR CALORIFIERS AND BUFFER TANKS

LOWER HEAT EXCHANGER FOR EXTRA 1,2 3 VT CALORIFIERS


The “antilegionella” coil, which is the heat exchanger with tubes bent to the bottom is an efficient innovation installed as a standard on every
Cordivari’s Extra boilers. This reduces the diffusion of legionellosis bacteria’s.

Advantages
• The legionellosis-prophylaxis protection coil can heat the complete quantity of water in an homogenous way. Even in the bottom area of the
Def

boiler which is impossible with traditional heat exchanger.


• Possibility of using lower capacity boilers for the same quantity of hot water needed.

B
A

STAINLESS STEEL 316 L COPPER


ANTI-LEGIONELLOSIS PROPHYLAXIS COIL ANTI-LEGIONELLOSIS PROPHYLAXIS COIL

Heat AVAILABLE FOR AVAILABLE FOR


exchange Output Def A B Price Price
surface ART. NR. ART. NR.

[m2] [Kw] [mm] [€] [€]

• EXTRA1 WXC 200 - EXTRA1 XXC 200


0,5 18 300 350 240 5204000010100 383,00 5204000060230 • EXTRA1 WRC 200 - EXTRA1 ZRC 200 261,00
• EXTRA2 WXC 200 - EXTRA2 XXC 200

• EXTRA1 WXC 300 - EXTRA1 XXC 300 • EXTRA1 WRC 300 - EXTRA1 ZRC 300
0,75 28 300 350 240 5204000010101 • EXTRA2 WXC 300 - EXTRA2 XXC 300 426,00 5204000060231 • EXTRA2 WRC 300 326,00
• EXTRA3 WXC 200

• EXTRA1 WXC 500 - EXTRA1 XXC 500 • EXTRA1 WRC 500 - EXTRA1 ZRC 500
1 38 300 371 261 5204000010102 477,00 5204000060232 380,00
• EXTRA3 WXC 300 • EXTRA3 WRC 300

• EXTRA2 WXC 500 - EXTRA3 WXC 500 • EXTRA2 WRC 500


1,5 59 300 561 311 5204000010113 xxx,00 5204000060242 xxx,00
EXTRA2 XXC 500 - EXTRA3 XXC500 • EXTRA3 WRC 500

• EXTRA1 WXC 800 • EXTRA1 WRC 800 - EXTRA1 ZRC 800


1,5 59 380 496 336 5204000010103 786,00 5204000060233 537,00
EXTRA1/M WXC 1500 - EXTRA1M XXC 1500 • EXTRA1/M WRC 1500 - EXTRA1M ZRC 1500

• EXTRA1 WXC 1000 - EXTRA1 XXC 1000 • EXTRA1 WRC 1000 - EXTRA1 ZRC 1000
2 86 380 496 336 5204000010104 847,00 5204000060234 692,00
• EXTRA2 WXC 800 • EXTRA2 WRC 800

2 94 430 595 415 5204000010110 • EXTRA1/M WXC 2000 - EXTRA1/M XXC 2000 943,00 5204000060240 • EXTRA1/M WRC 2000 - EXTRA1/M ZRC 2000 766,00

2,5 116 430 616 436 5204000010111 • EXTRA1/M WXC 3000 - EXTRA1/M XXC 3000 1.007,00 5204000060241 • EXTRA1/M WRC 3000 - EXTRA1/M ZRC 3000 834,00

• EXTRA1 WXC 1500 - EXTRA1 XXC 1500 • EXTRA1 WRC 1500 - EXTRA1 ZRC 1500
• EXTRA2 WXC 1000 - EXTRA2 WXC 1500 • EXTRA2 WRC 1000 - EXTRA2 WRC 1500
3 133 380 607 452 5204000010105 1.215,00 5204000060235 935,00
EXTRA2 XXC 1000 - EXTRA2 XXC 1500 EXTRA2 ZRC 1000 - EXTRA2 ZRC 1500
• EXTRA3 WXC 1000 - EXTRA3 WXC 1500 • EXTRA3 WRC 1000 - EXTRA3 WRC 1500

• EXTRA1 WXC 2000 - EXTRA1 XXC 2000


• EXTRA1 WRC 2000 - EXTRA1 ZRC 2000
EXTRA1/M WXC 4000 - EXTRA1/M XXC 4000
4 180 430 636 457 5204000010106 1.704,00 5204000060236 EXTRA1/M WRC 4000 - EXTRA1/M ZRC 4000 1.251,00
• EXTRA2 WXC 2000 - EXTRA2 XXC 2000
• EXTRA2 WRC 2000 - EXTRA3 WRC 2000
• EXTRA3 WXC 2000

• EXTRA1 WXC 3000 - EXTRA1 XXC 3000


• EXTRA1 WRC 3000 - EXTRA1 ZRC 3000
EXTRA1/M WXC 5000 - EXTRA1/M XXC 5000
5 216 430 678 498 5204000010107 2.022,00 5204000060237 EXTRA1/M WRC 5000 - EXTRA1/M ZRC 5000 1.586,00
• EXTRA2 WXC 3000 - EXTRA2 XXC 3000
• EXTRA2 WRC 3000 - EXTRA3 WRC 3000
• EXTRA3 WXC 3000

• EXTRA1 WXC 4000 - EXTRA1 XXC 4000 • EXTRA1 WRC 4000 - EXTRA1 ZRC 4000
8 330 430 1250 598 5204000010108 • EXTRA2 WXC 4000 - EXTRA2 XXC 4000 3.134,00 5204000060238 • EXTRA2 WRC 4000 2.190,00
• EXTRA3 WXC 4000 • EXTRA3 WRC 4000

• EXTRA1 WXC 5000 - EXTRA1 XXC 5000


• EXTRA1 WRC 5000 - EXTRA1 ZRC 5000
10 401 430 1550 538 5204000010109 • EXTRA2 WXC 5000 - EXTRA2 XXC 5000 3.804,00 5204000060239 2.676,00
• EXTRA2 WRC 5000 - EXTRA3 WRC 5000
• EXTRA3 WXC 5000

66
ACCESSORIES FOR CALORIFIERS AND BUFFER TANKS

MIDDLE AND UPPER HEAT EXCHANGER FOR EXTRA 2 AND 3 VT AND EXTRA 1 OR CALORIFIERS
Def

STAINLESS STEEL 316 L COPPER


STRAIGHT COIL STRAIGHT COIL

Heat AVAILABLE FOR AVAILABLE FOR


Out-
exch. Def A Price Price
put ART. NR. ART. NR.
surf.
[m2] [Kw] [mm] [€] [€]
• EXTRA2 WXC 200
• EXTRA1 WXC OR 200 • EXTRA1 WRC OR 200 • EXTRA2 WRC 200
0,5 18 300 445 5204000010074 EXTRA2 XXC 200 • EXTRA3 WXC 200 352,00 5204000060200 • EXTRA3 WRC 200 249,00
EXTRA1 XXC OR 200 EXTRA1 ZRC OR 200 • EXTRA3 WRC 200
• EXTRA3 WXC 200

• EXTRA1 WXC OR 300 • EXTRA2 WXC 300 • EXTRA1 WRC OR 300


0,75 28 300 445 5204000010075 • EXTRA3 WXC 300 390,00 5204000060201 • EXTRA2 WRC 300 • EXTRA3 WRC 300 311,00
EXTRA1 XXC OR 300 EXTRA2 XXC 300 EXTRA1 ZRC OR 300

• EXTRA1 WXC OR 500 • EXTRA3 WXC 500 • EXTRA1 WRC OR 500 • EXTRA3 WRC 500
1 38 300 475 5204000010076 • EXTRA3 WXC 300 432,00 5204000060202 • EXTRA3 WRC 300 362,00
EXTRA1 XXC OR 500 • EXTRA 3 WXC 800 EXTRA1 ZRC OR 500 • EXTRA 3 WRC 800

• EXTRA2 WXC 500


• EXTRA2 WRC 500
1,5 300 690 5204000010077 --- EXTRA2 XXC 500 --- 742,00 5204000060203 --- --- 482,00
• EXTRA3 WRC 500
• EXTRA3 WXC 500

• EXTRA1 WXC OR 800 • EXTRA3 WXC 1000 • EXTRA1 WRC OR 800 • EXTRA3 WRC 1000
1,5 59 380 600 5204000010078 --- 791,00 5204000060204 511,00
EXTRA1 XXC OR 800 EXTRA3 WXC 1500 EXTRA1 ZRC OR 800 EXTRA3 WRC 1500

ACCESSORIES
• EXTRA2 WXC 800
• EXTRA2 WRC 800
EXTRA2 WXC 1000
• EXTRA1 WXC OR 1000 • EXTRA1 WRC OR 1000 EXTRA2 WRC 1000
2 86 380 560 5204000010079 EXTRA2 XXC 1000 • EXTRA3 WXC 2000 797,00 5204000060205 • EXTRA3 WRC 2000 663,00
EXTRA1 XXC OR 1000 EXTRA1 ZRC OR 1000 • EXTRA3 WRC 800
• EXTRA3 WXC 1000
EXTRA3 WRC 1000
EXTRA 3 WXC 800

• EXTRA2 WXC 1500


• EXTRA1 WXC OR 1500 • EXTRA1 WRC OR 1500 • EXTRA2 WRC 1500
3 133 380 720 5204000010080 EXTRA2 XXC 1500 • EXTRA3 WXC 3000 1.149,00 5204000060206 • EXTRA3 WRC 3000 909,00
EXTRA1 XXC OR 1500 EXTRA1 ZRC OR 1500 • EXTRA3 WRC 1500
• EXTRA3 WXC 1500

• EXTRA2 WXC 2000


• EXTRA1 WXC OR 2000 • EXTRA1 WRC OR 2000 • EXTRA2 WRC 2000
4 180 430 750 5204000010081 EXTRA2 XXC 2000 • EXTRA3 WXC 4000 1.628,00 5204000060207 • EXTRA3 WRC 4000 1.197,00
EXTRA1 XXC OR 2000 EXTRA1 ZRC OR 2000 • EXTRA3 WRC 2000
• EXTRA3 WXC 2000

EXTRA2 WXC 3000


• EXTRA1 WXC OR 3000 • EXTRA1 WRC OR 3000 • EXTRA2 WRC 3000
5 216 430 780 5204000010082 EXTRA2 XXC 3000 • EXTRA3 WXC 5000 1.923,00 5204000060208 • EXTRA3 WRC 5000 1.475,00
EXTRA1 XXC OR 3000 EXTRA1 ZRC OR 3000 • EXTRA3 WRC 3000
EXTRA3 WXC 3000

EXTRA2 WXC 4000


• EXTRA1 WXC OR 4000 • EXTRA1 WRC OR 4000 • EXTRA2 WRC 4000
8 330 430 1250 5204000010083 EXTRA2 XXC 4000 --- 2.969,00 5204000060209 --- 2.018,00
EXTRA1 XXC OR 4000 EXTRA1 ZRC OR 4000 • EXTRA3 WRC 4000
EXTRA3 WXC 4000

EXTRA2 WXC 5000


• EXTRA1 WXC OR 5000 • EXTRA1 WRC OR 5000 • EXTRA2 WRC 5000
10 401 430 1510 5204000010084 EXTRA2 XXC 5000 --- 3.520,00 5204000060210 --- 2.426,00
EXTRA1 XXC OR 5000 EXTRA1 ZRC OR 5000 • EXTRA3 WRC 5000
EXTRA3 WXC 5000

67
ACCESSORIES FOR CALORIFIERS AND BUFFER TANKS

COPPER FINNED AND TINNED HEAT EXCHANGERS (AVAILABLE ON EXTRA PLUS)

Heat exchanger COPPER FINNED AND TINNED COIL


De L P Capacity
surface AVAILABLE ON EXTRA PLUS Price [€]

[m2] [mm] [Gas] [lt] ART. NR.


0,76 142 400 1” 0,60 5205000060003 175,00
0,94 142 410 1” 0,54 5205000060002 270,00
1,58 170 440 1” 1,21 5205000060004 344,00
2,27 170 570 1” 1,79 5205000060005 527,00
2,63 190 570 1” 2,07 5205000060006 556,00
3,17 190 665 1” 2,51 5205000060007 577,00
4,54 190 750 1” 1/4 3,60 5205000060008 932,00
5,26 190 850 1” 1/4 4,14 5205000060009 1.001,00
6,34 190 980 1” 1/4 5,10 5205000060010 1.211,00

COPPER FINNED AND TINNED HEAT EXCHANGERS (AVAILABLE ON EXTRA HP)

Heat exchanger COPPER FINNED AND TINNED COIL


De L P Capacity
surface AVAILABLE ON EXTRA HP Price [€]

[m2] [mm] [Gas] [lt] ART. NR.


3,06 190 560 1” 1/4 2,46 5205000060011 634,00
5,26 250 650 1” 1/4 4,23 5205000060012 1.074,00
7 250 750 1” 1/4 5,63 5205000060013 1.255,00

ART. NR. CONTROFLANGE Suitable for the following coils [m2] Price [€]
5212000911002 C/SOST. D.300X10,0 POLW. 2 ATT. 1" 0,76 - 0,94 - 1,58 120,00
5212000911003 C/SOST. D.380X10,0 POLW. 2 ATT. 1" 0,76 - 0,94 - 1,58 - 2,27 - 2,63 - 3,17 125,00
5212000911004 C/SOST. D.380X10,0 POLW. 2 ATT.1"1/4 4,54 - 5,26 - 6,34 125,00
5212000911005 C/SOST. D.430X10,0 POLW. 2 ATT.1"1/4 4,54 - 5,26 - 6,34 130,00
5212000911006 C/SOST. D.430X10,0 POLW. 2 ATT. 1" 0,76 - 0,94 - 1,58 - 2,27 - 2,63 - 3,17 140,00
5212000911009 C/SOST.L. 650 D.300X10,0 POLW. 2 ATT. 1" 2,27 - 2,63 - 3,17 125,00
5212000911010 C/SOST.L. 750 D.300X10,0 POLW. 2 ATT.1"1/4 4,54 - 5,26 - 6,34 125,00
5212000911011 D.380X10,0 POLW.2 ATT.1"1/4 3,06 - 5,26 D. 250 - 7 120,00
5212000911012 D.300X10,0 POLW.2 ATT.1"1/4 3,06 120,00

FLANGE PLATE FOR “EXTRA 1,2,3” CALORIFIERS AND ACCUMULATION TANKS


The Flange plate includes 2 sleeve collars for the connection to the operating system. This allows the circulation of the liquid within the heat exchanger’s serpentine doing the real separation between the
incoming liquid and the outgoing one. The flange plate is in carbon steel. Blind flange for accumulation tank in Polywarm®.

ART. NR. Price [€] Diameter [mm] ART. NR. Price [€] Diameter [mm]
5206000310001 57,00 300 5206000910201 57,00 300
5206000310002 73,00 380 5206000910202 73,00 380
5206000310003 85,00 430 5206000910203 85,00 430
Version for EXTRA 1 - 2 - 3 Blind version for Accumulation Tank

GASKET FOR FLANGE PLATE


The function of the EPDM gasket is to connect between them components and extractible heat exchanger. Sold by pair, this includes the gasket with crosspiece which is placed between the flange plate and
the heat exchanger’s plate. The gasket without crosspiece is placed between heat exchanger’s plate and the boiler’s flange.

PAIR OF GASKET FOR BOILERS EXTRA 1,2,3 PAIR OF GASKET FOR BOILER EXTRA 1 STEAM
ART. NR. Price [€] Diameter [mm] ART. NR. Price [€] Diameter [mm]
5021220400015 16,00 300 5021220460011 17,00 300
5021220400016 26,00 380 5021220460012 27,00 380
5021220400017 30,00 430 5021220460013 31,00 430
Pair composed of one gasket with crosspiece and one Pair composed of one gasket with crosspiece and
without. one without.
Silicone gaskets suitable for alimentary use for max Made in CEFLEX gum for max. temperature up to
temperature up to 200° C. (D.M. n.174 dated 2004). 192°.

SELECTION OF THE FLANGE PLATE AND GASKET FOR “EXTRA 1,2,3” CALORIFIERS
Flange plate Extra 1 Extra 2 Extra 3
diameter LOWER heat exchanger LOWER heat exchanger UPPER heat exchanger LOWER heat exchanger MIDDLE heat exchanger UPPER heat exchanger
[mm] [lt]
300 From 200 to 500 From 200 to 500 From 200 to 500 From 200 to 500 From 200 to 500 From 200 to 500
380 From 800 to 1500 From 800 to 1500 From 800 to 1500 From 800 to 1500 From 800 to 1500 From 800 to 1500
430 From 2000 to 5000 From 2000 to 5000 From 2000 to 5000 From 2000 to 5000 From 2000 to 5000 From 2000 to 5000

68
ACCESSORIES FOR CALORIFIERS AND BUFFER TANKS

ADDITIONAL COPPER FINNED COIL


The additional copper finned coil is available for Bolly, Bolly2, Bolly2 Double Bottom ≥ 300 lt.

3/4” 3/4”

3/4” ADDITIONAL FINNED COIL 3/4” ADDITIONAL FINNED COIL.


WITH FLANGE PLATE AND GASKET.

ART. NR. DESCRIPTION Price [€] ART. NR. DESCRIPTION Price [€]
Additional finned coil for BOLLY Polywarm® Additional copper finned coil
5221000910001 333,00 5205000060002 270,00
Surface=0,94m2 - Diam.=145 mm - L=370 mm Surface=0,94m2 - Diam.=145 mm - L=370 mm
Additional finned coil for BOLLY Inox AVAILABLE FOR CAPACITY OVER LT. 300, ONLY.
5221000010001 366,00
Surface=0,94m2 - Diam.=145 mm - L=370 mm
AVAILABLE FOR CAPACITY OVER LT. 300, ONLY.

FAST HEAT EXCHANGER

Price Surface External exchanger diameter Altezza H 1-2 3-4 5


Model ART. NR.
[€] [m2] [mm] [mm] Connections
24000 3681160120001 397,00 0,5 320 1” 1/2 1/2” 3/8”
35000 3681160120002 452,00 0,7 175 425 1” 1/2 1/2” 3/8”
45000 3681160120003 521,00 0,9 525 1” 1/2 1/2” 3/8”

Primary DHW Primary DHW


Exchanged Power Exchanged Power
Model Capacity Production Capacity Production
[Kcal/h] [Kw] [lt/h] [lt/h] [Kcal/h] [Kw] [lt/h] [lt/h]
24000 24200 28,14 1880 480 24147 28,08 1880 685
35000 35651 41,46 2150 709 35335 41,09 2150 1004
45000 45124 52,48 2380 897 44554 51,82 2380 1267

Technical descriptions Application CONNECTIONS


Fast Heat Exchanger consists in a double spiral copper coil closed in carbon Fast production of sanitary hot water.
1 Primary inlet
steel. Its particular internal shape , imposing the two fluids to circulate in Material
opposite current, granting a fast and efficient heating exchange. Carbon steel 2 Primary outlet
They are mainly used in thermo-hydraulic field , they are well used to prepare Heat exchanger 3 Secondary inlet
the DHW with fireplaces or to biomass generator. Fixed Heat Exchanger with double spiral copper coil. 4 Secondary outlet
Warranty 5 Air clearing
2 years -See general sales terms and conditions

OPENED EXPANSION TANKS – STAINLESS STEEL AISI 304 / GALVANIZED


Opened Expansion tanks are used as safety accessories in the heating systems where, due to legal reason it is vorbidden to install closed expansion tanks systems. In Italy, for the water fireplaces, they are
still one of the most simple and economic solution. Expansion tank is composed by a cover unit where all the security piping of outlet pipe for too full , supplying and systems charge , should arrive. Its rule
is to merge the water in excess due caused by temperature increase. Expansion Tank should be placed on the higher point reached by the water and should have an expanding volume not less the expansion
volume developed by all the water contained into the system , whose value should be declared in the project.
Expansion volume need it in the system is calculated by the following formula:

ACCESSORIES
“Ve = C x e”
Where C is the water contained into the system and “e" is equal to the difference between the expansion factor of the water at the minimum conceivable temperature with sleeping system and the expansion
factor of the water at boiling temperature of atmospheric pressure. Considering the first water temperature equal to 10°C and the boiling one at 100° C
“e” = 0.0431
If need you can connect more than one tanks all together.
Open Polyeth
Polyethylene expansion tank. Galvanized
Stainless Steel 316 L
(See Cordivari
Cordiv TANKS catalogue)

Capacity STAINLESS STEEL 316 L GALVANIZED Dimension


[lt] ART. NR. Price [€] ART. NR. Price [€] [mm]
30 3941014010001 177,00 3941164010001 45,00 275x455x245
50 3941014010002 234,00 3941164010002 56,00 276x455x430

CONNECTING SCHEME
CORDIVARI EXPANSION TANKS
TA DETAILS OPENED EXPANSION TANK
OUTLET PIPE AND TOO FULL
SECURITY HOLE Ø 30
SECURITY PIPES

TOO FULL/OUTLET 1” FEMALE


EXPANSION VOLUME
FLOATING ½” FEMALE
SYSTEM INLET 1” FEMALE SUPPLYING PIPE

STORAGE VOLUME
FOR 30 LTS MODEL , EXPANSION VOLUME IS 7.5 LTS
FROM GENERATOR
TO GENERATOR

FOR 50 LTS MODEL , EXPANSION VOLUME IS 30 LTS

69
ACCESSORIES FOR CALORIFIERS AND BUFFER TANKS

DOMESTIC HOT WATER MODULE MACS®


Domestic Hot Water station MACS® by Cordivari has been designed to combine benefits from storage heating water with the comfort and safety of immediate production of DHW.

MACS® station MACS® station The MACS® station is connected to the Buffer Tanks, thanks to a circulator, the heated water
TECHNICAL DATA is moved to a stainless steel plate exchanger to the buffer mounted, which instantly heats the
70 Kw 120 Kw
domestic water, using the heat of 'thermal storage” ensuring maximum hygiene and comfort,
Primary circuit maximium flow rate (inlet) 1.200 l/h 1620 l/h with the possibility to adjust the outlet DHW temperature. Station MACS ® thus enables the
production of Domestic Hot Water (SHW) instantly, with high flows and high efficinecy, without
D.H.W. maximium flow rate (outlet) 1.800 l/h ∆P 0,5 bar 3.000 l/h ∆P 0,5 bar the support of an installed sourcer to meet the very high peak power required during production.
At the same time requires no accumulation of DHW, with following advantages:
D.H.W. temperature set 45÷55 °C 45°C - 50°C
• reducing overall dimensions
Maximum working pressure 6 bar 6 bar
• total hygiene
Power supply 230 V AC, 93 W 230 V AC, 132 W
• easy maintenance
Minimal D.H.W. request to activate MACS® station 2 l/m 2,8 l/m
• Reduction of Legionellosis risk.
Minimal D.H.W. request to disactivate MACS®
1,3 l/m 1,1 l/m
station (when working)
MACS® station also reduces volumes as a single buffer tank is also producing DHW, thus
Insulated D.H.W. case dimanesion (LxHxW) 340x400x165 mm 630x410x180 mm eliminating the volume of traditional calorifiers. In fact, the amount of DHW that can be
produced by the MACS® station is equal if not superior to those obtained from a calorifiers with
Connections ¾" M 1" F / ¾" F same capacity of accumulation because the heating hot water is stored at a higher temperature
compared to temoperature of DHW.

120 Kw 70 Kw External lining


Painted metal sheet internally insulated
400 340
Heat exchanger
Inox plate heat exchanger
Plate heat
Warranty Primary exchanger
400

2 years circuit
See general sales terms and conditions.
620

A.C.S.

Sanitary
A.C.S.
circuit

DHW station DHW station DHW production (at 10-45°C)


Price
ART.NR. Description maximum output maximum flow rate with 70°C storage
[Kw] [lt/min] [lt/min] [€]
3316006700001 DOMESTIC HOT WATER STATION 70 KW 70 30 24 1.190,00
3316006700002 DOMESTIC HOT WATER STATION 120 KW 120 50 41 2.350,00

EASY CONTROL: ELECTRONIC DISPLAY FOR CALORIFIERS


Features

• Possibility to programme, for each day of the week, 4 different accumulation temperature;
• Antilegionellosis programme with possibility to set time and temperature of the antilegionellosis
cicles.
• Hot sanitary water of the thermostatic control with saving energy function.
• Control of the temperature’s probe of the calorifier.
• Control of the anode.
• Control of the eventual electrical immersion (up to 3000W).
• Control of recycling pump also with timer.

Complete with temperature probe ART. NR. Price [€]


Version for existing system 5220280000001 359,00
Installed version on EXTRA 1 - BOLLY 1 - ACCUMULATION TANKS 5005000310001 408,00

70
ACCESSORIES FOR CALORIFIERS AND BUFFER TANKS

ANODES
The calorifiers proof corrosion is guaranteed not only by the internal coating material but also by the anodes.
As standard, Cordivari provides its calorifiers with Anoden-tester and with electronic anode on demand.

MAGNESIUM ANODES
The simpletest magnesium anodes allows, without emptying the calorifiers,
to check the consumption of magnesium bar simply by acting on the button. Any
leakage, acknowledges that the anode must be replaced. The new chain magnesium
anodes, allows a comfortable maintenance and replacement due to their special
flexible structure, especially in case of installation of calorifiers in premises with
Anode with Magnesium low ceiling.
Simpletest insuled cap anode chain

Dimension SUITABLE FOR


ART. NR. Price [€] DESCRIPTION CONNECTIONS EXTRA1,2,3 INTERKA BOLLY2 e
INTERKA BOLLY
[mm] Accumulation SOLARE BOLLY2 DF COMBI
Polywarm Polywarm
Tanks, Polywarm Polywarm Polywarm
5200000040021 41,00 SIMPLETEST 32 x 200 - - 80/100/150 - - -

5200000040023 47,00 SIMPLETEST 32 x 350 - - 200/300 - - -

5200000040033 44,00 INSULATED CAP + GASKET 32 x 350 200/300 - - 150 150 -

5200000040034 47,00 INSULATED CAP + GASKET 32 x 450 - - - 300/200 300/200


1”1/4
5200000040035 52,00 INSULATED CAP + GASKET 32 x 520 500 - - 400 400/800 (x2)

5200000040036 66,00 INSULATED CAP + GASKET 32 x 650 800/2000 (x2) - - 500/800 500/1000 (x2)

5200000040037 73,00 INSULATED CAP + GASKET 32 x 800 3000 (x2) - - 1000 -


1500/4000 (x2)
5200000040038 77,00 INSULATED CAP + GASKET 32 x 900 5000 (x2) - - - - -
570/800
5200000040039 37,00 CHAIN (4 el.) with INSULATED CAP + Gasket 22 x 631 3/4” - - - - - 1000/1500/2000
5200000040006 22,00 M8 32 x 200 - 150 - - - -
M8
5200000040007 29,00 M8 32 x 400 - 200/300 - - - -

ELECTRONIC ANODE WITH TITANIUM IMPRESSED ELECTRICITY

Only for Polywarm® calorifiers and accumulation tanks

Electronic Anode FITTED FOR


ART. NR. Price [€] Dimensions - length Connections Extra1,2,3 Interka Polywarm, Bolly2 e
[mm] Bolly Polywarm
Vasi Inerz. Polywarm Interka Solare Polywarm Bolly 2 DF Polywarm
5200000000008 173,00 L. 200 200, 300 80, 100, 120, 150, 200, 300 150, 200, 300 150, 200, 300

ACCESSORIES
5200000000009 215,00 L. 500 500, 800 - 500 500
5200000000011 263,00 L. 400 1”1/4 Gas 1000, 1500 - 800, 1000 -
5200000000012 392,00 DOPPIO L. 400 - - - 800, 1000
5200000000013 477,00 DOPPIO L. 800 2000,3000,4000,5000 - - 200

• Use • Operating conditions


The Titanium electronic anode is , by opposite to the normal one, not subject to consumption and The input disposal is positioned in a insulated box and it’s equipped with a light led, located on front
doesn’t need any maintenance or replacement . The protection against corrosion is obtained ensuring side. Green light=working OK – Red light = Wrong working.
the electrolyte power through the continuous energy produced by the titanium bar. In this last case is necessary to take the electrical plug away and get in touch with an installer , that
will provide to put everything in goods order.

• Advantage
Active protection through the power given by the titanium anode
• Material High level working flexibility, in order to fit to the different internal coatings and to the water capacity,
The anode is composed by a Titanium rod, with its active final part, that has to be connected to the ensured by an automatic regulation of the working electricity .
vessel. Definitive and easy protection. It is important anyway to check that the electricity is constantly
This system ensures the good working and a long life both to the anode and the cilinder. working. Cancelation of any worries and maintenance problems and costs.

ANODEN-TESTER
It is the new system to keep easily under control by seeing the consumption of the magnesium anode. You have just to
push the button to check if the anode has to be replaced. Included with the anoden-tester, cap and boss.

ART. NR. Price [€]


5221000000017 37,00

71
ACCESSORIES FOR CALORIFIERS AND BUFFER TANKS

SOFT INSULATION
Insulation are realized in polyurethane soft foam 50 mm – 0.038 W/mK For Interka boiler tops are 2
The external lining insulation in red SCAI RAL 3000 or grey RAL 9006 For Extra 2 boiler we supply with one more flange cover kit
Complete with top and flange cover For Extra 3 boiler we supply with two more flange cover kits

50 MM. SOFT POLYURETHANE FOAM 50 MM. SOFT POLYURETHANE FOAM 100 MM. SOFT POLYURETHANE FOAM
COLOR RED RAL 3000 COLOR RED RAL 3000 COLOR GREY RAL 9006
EXTRA 1, EXTRA 2, EXTRA 3,
EXTRA 1 (Horizontal version) BOLLY 2 Double Bottom
EXTRA PLUS, EXTRA HP, VASO INERZIALE
Model Diameter Insulation Model Diameter Insulation Model Diameter Insulation Price
Price [€] Price [€]
[lt] [mm] sp = 50 mm [lt] [mm] sp = 50 mm [lt] [mm] sp = 100 mm [€]

200 450 5202320620001 163,00 200 450 5202310620001 179,00 800 750 5215320620152 436,00
300 550 5202320620002 188,00 300 550 5202310620002 228,00 1000 850 5215320620153 523,00
500 650 5202320620003 240,00 500 650 5202310620003 293,00
800 750 5202320620004 310,00 800 750 5202310620004 340,00
1000 850 5202320620005 335,00 1000 850 5202310620005 408,00
1500 950 5202320620006 456,00 1500 950 5202310620006 502,00
2000 1100 5202320620007 528,00 2000 1100 5202310620007 582,00
3000 1250 5202320620008 569,00 3000 1250 5202310620008 627,00
4000 1450 5202320620009 674,00 4000 1450 5202310620009 740,00
5000 1600 5202320620011 742,00 5000 1600 5202310620011 816,00

100 MM. SOFT POLYURETHANE FOAM 100 MM. SOFT POLYURETHANE FOAM 100 MM. SOFT POLYURETHANE FOAM
COLOR GREY RAL 9006 COLOR GREY RAL 9006 COLOR GREY RAL 9006
COMMUNICATING BUFFER BUFFER TANKS STRATIFICATION BUFFER TANK

Model Diameter Insulation Model Diameter Insulation Model Diameter Insulation


Price [€] Price [€] Price [€]
[lt] [mm] sp = 100 mm [lt] [mm] sp = 100 mm [lt] [mm] sp = 100 mm

800 790 (SX) 5215320620272 330,00 200 450 5215320620085 199,00 800 790 5215320620257 330,00
800 790 (DX) 5215320620270 330,00 300 550 5215320620013 236,00 1000 790 5215320620258 382,00
1000 790 (SX) 5215320620273 382,50 500 650 5215320620014 275,00
1000 790 (DX) 5215320620271 382,50 800 790 5215320620015 322,00
1000 790 5215320620016 375,00
1500 950 5215320620017 443,00
2000 1100 5215320620018 544,00
3000 1250 5215320620194 790,00
4000 1450 5215320620195 970,00
5000 1600 5215320620196 1020,00

72
ACCESSORIES FOR CALORIFIERS AND BUFFER TANKS

SOFT INSULATION

100 MM. SOFT POLYURETHANE FOAM 100 MM. SOFT POLYURETHANE FOAM 100 MM. SOFT POLYURETHANE FOAM
COLOR GREY RAL 9006 COLOR GREY RAL 9006 COLOR GREY RAL 9006
COMBI 1 - COMBI 2 - COMBI 3 ECO COMBI 1 - ECO COMBI 2 - ECO COMBI 3 ECO COMBI DOMUS

Model Diameter Insulation Model Diameter Insulation Model Diameter Insulation


Price [€] Price [€] Price [€]
[lt] [mm] sp = 100 mm [lt] [mm] sp = 100 mm [lt] [mm] sp = 100 mm

570 650 5215320620189 339,00 570 650 5215320620067 339,00 200 450 5215320620239 199,00
800 800 5215320620190 379,00 800 790 5215320620068 379,00 300 550 5215320620240 236,00
1000 800 5215320620191 438,00 1000 790 5215320620069 438,00 500 650 5215320620241 275,00
1500 950 5215320620192 510,00 1250 900 5215320620070 480,00
2000 1100 5215320620193 644,00 1500 950 5215320620071 510,00
2000 1100 5215320620072 644,00

TOP AND FLANGE COVERS

TOP COVERS
SOFT PVC HEAD WITH HOLE SOFT PVC HEAD
TO COVER THE FLANGE TO COVER BLIND FLANGE
BOLLY 1 - BOLLY 2 - BOLLY 2 DF

ACCESSORIES
Model Diameter Insulation Use for heat exchanger with Use for heat exchanger with
Price [€] ART. NR. Price [€] ART. NR. Price [€]
[lt] [mm] sp = 50 mm flange diameter [mm] blind flange diameter [mm]

150 513 5209000630002 17,00 300 5211000620001 32,00 300 5211000620006 32,00
200 561 5209000630003 18,00 380 5211000620002 37,00 380 5211000620007 37,00
300 672 5209000630005 27,00 430 5211000620003 38,00 430 5211000620008 38,00
400 720 5209000630006 28,00
500 790 5209000630010 32,00

73
ACCESSORIES FOR CALORIFIERS AND BUFFER TANKS

VALVES KIT
RECYCLE KIT ECO COMBI PRIMARY SECURITY VALVE
ART. NR. Price [€] ART. NR. SETTING Price [€]
5221000000019 56,00 5302000000021 2,5 bar 17,00
Attacco 3/4” Attacco 1/2” M x 1/2” F per Interka solare

RECYCLE KIT AND MIXER ECO COMBI TP SECURITY VALVE


ART. NR. Price [€] ART. NR. SETTING Price [€]
5221000000020 206,00 5302000000020 90°C/6bar 40,00
Attacco 3/4” M Connections 1/2” M x 1/2” F.
Avoiding over temperature when there is no withdrawing of DHW.

DRAWING TUBE FOR SANITARY HOT WATER


Flexible tube in Stainless steel for withdrawing Sanitary hot water which is placed on the superior connection where the water reach the highest temperature. Standard on the bottom area: incoming Sanitary hot water.

Length
CODICE Connections Price [€]
[mm]
5221000000006 1”1/4 Gas M 226 mm 29,00
5221000000007 1”1/2 Gas M 339 mm 35,00
5221000000008 2” Gas M 339 mm 41,00
5221000000009 2” Gas M 617 mm 50,00
5221000000010 3” Gas M 617 mm 64,00

THERMOMETER
With 1/2” gas connection - from 0°-120° C

ART. NR. Description Price [€] Diameter [mm]


5032240000107 Thermometer - 10 units box 135,00 60

ELECTRICAL IMMERSIONS KIT

R
Electric heaters can be used as integration on calorifiers and tanks, stainless steel heaters,
protection class IP45 supplied with thermostat, safety thermostat reset user and 2 mt of
electrical cable wired and without plug. L

Tension Output Length L Connection R


ART. NR. Price [€]
Volt [Kw] [mm] Gas M
5240000000034 189,00 1,5 400
220 V
5240000000035 195,00 2 500 1”1/2
MONOPHASE
5240000000036 199,00 3 600

Electric heaters can be used as integration on calorifiers and tanks, heating elements in
INCOLOY 800, protection class IP45 supplied with thermostat, safety thermostat manual
reset and 2 mt of electrical cable wired and without plug.
Tension Output Length L Connection R
R

ART. NR. Price [€]


[Volt] [Kw] [mm] Gas M 4-9 Kw
5240000000027 294,00 4 415
L
5240000000028 298,00 5 500
400 V
1”1/2
THREEPHASE
5240000000029 303,00 6 600

5240000000030 308,00 9 750

5240000000031 322,00 12 750


R

12-18 Kw
400 V
5240000000032 337,00 15 800 2"
THREEPHASE
L
5240000000033 342,00 18 800

74
INERTIAL
TANKS

FOR COMPRESSED AIR RECEIVERS PRODUCTS


SEE COMPRESSED AIR RECEIVERS CORDIVARI CATALOGUE

75
ACQ. REF. ZC 20 VT
VERTICAL GALVANIZED CHILLED WATER TANK

ACQ. REF. ZC 20 VT
Capacity
(WITH INSULATION 20 MM)

[liters] ART. NR. Price [€]

100 3001162130001 279,00


200 3001162130002 341,00
300 3001162130003 438,00
500 3001162130004 630,00
800 3001162130005 916,00
1000 3001162130006 1.090,00
1500 3001162130007 1.540,00
2000 3001162130008 1.995,00
3000 3001162130009 2.664,00
4000 3001162130010 4.378,00
WORKING PRESSURE OPERATING TEMPERATURE 5000ø1600 3001162130012 5.465,00
Pmax Tmax Available on request with Class 1 self-estinguishing insulation
6 bar -10° / +50° C

Technical descriptions Application Insulation


Vertical Chilled water tanks are used for air conditioning Storage of chilled water for ac installations. 20 mm fixed polyethylene – not subject to condensation. Not self-
installations in order to increase the thermal inertia and, for those estinguishing version.
installations without a low water-capacity, avoiding that the External lining
chilling generator is continually working. Blue skai with plastic black caps for connections Warranty
These tanks are galvanized inside and outside, with immersion in 2 years
a pool of fused zinc with pureness over 98,25% (Uni EN 1179). See general sales terms and conditions.

De
(2)

H4 (3) (7) (4)

H3 (8)
A

CONNECTIONS
H

1 Drain
2 Safety valve
3
4
Connections to the system
H2 (5) (6) 5
6
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

7
Instrumentation 1/2” Gas F
8
H1 (1)
0

Capacity De H A H1 H2 H3 H4 1-2 3-4-5-6


[liters] [mm] Connections Gas F

100 400 1007 1020 73 287 592 792 1” 1/4 1” 1/2


200 450 1407 1420 68 297 927 1177 1” 1/4 1” 1/2
300 550 1519 1535 129 404 994 1244 1” 1/4 2”
500 650 1811 1825 121 441 1241 1491 1” 1/4 3”
800 750 2108 2125 108 458 1458 1758 1” 1/4 3”
1000 850 2162 2180 96 479 1479 1779 1” 1/2 3”
1500 950 2473 2495 113 538 1748 2048 2” 3”
2000 1100 2544 2570 95 564 1774 2074 2” 3”
3000 1250 2889 2920 140 664 1964 2364 2” 4”
4000 1450 2996 3030 116 706 2006 2406 2” 4”
5000 Ø 1600 1600 3087 3125 97 742 2042 2442 2” 4”

76
ACQ. REF. ZC 20 OR
HORIZONTAL GALVANIZED CHILLED WATER TANK

ACQ. REF. ZC 20 OR
Capacity
(WITH INSULATION 20 MM)

[liters] ART. NR. Price [€]

100 3001161030001 306,00


200 3001161030002 409,00
300 3001161030003 506,00
500 3001161030004 702,00
800 3001161030005 998,00
1000 3001161030006 1.188,00
1500 3001161030007 1.678,00
2000 3001161030008 2.241,00
3000 3001161030009 2.933,00
4000 3001161030010 4.660,00
5000ø1600 3001161030012 6.014,00 WORKING PRESSURE OPERATING TEMPERATURE

Available on request with Class 1 self-estinguishing insulation Pmax Tmax


6 bar -10° / +50° C

Technical descriptions Application Insulation


Horizontal Chilled water tanks are used for air conditioning Storage of chilled water for ac installations. 20 mm fixed polyethylene – not subject to condensation. Not self-
installations in order to increase the thermal inertia and, for those estinguishing version.
installations without a low water-capacity, avoiding that the External lining
chilling generator is continually working. Blue skai with plastic black caps for connections Warranty
These tanks are galvanized inside and outside, with immersion in 2 years
a pool of fused zinc with pureness over 98,25% (Uni EN 1179). See general sales terms and conditions.

0 L1 (4) (7) (3) L2 (6) (5)


(3) (5)
H3

CONNECTIONS
1 Drain
2 Safety valve
De

3 H2 (1) (7) (8) (2)


4 INERTIAL
Connections to the system
5 TANKS
6
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

7 H1 (4) (6)
Instrumentation 1/2” Gas F 0
8

L3 L4 (8) L5
L

Capacity De L L1 L2 L3 L4 L5 H1 H2 H3 1-2 3-4-5-6


[liters] [mm] Connections Gas F

100 400 935 215 720 290 415 645 63 293 523 1” 1/4 1” 1/2
200 450 1340 230 1110 335 480 1005 61 316 571 1” 1/4 1” 1/2
300 550 1390 275 1115 365 525 1025 115 425 760 1” 1/4 2”
500 650 1690 320 1370 415 570 1275 105 470 855 1” 1/4 3”
800 750 2000 350 1650 480 650 1520 101 516 951 1” 1/4 3”
1000 850 2066 383 1683 513 683 1553 96 561 1046 1” 1/2 3”
1500 950 2360 425 1935 560 725 1800 82 597 1142 2” 3”
2000 1100 2450 470 1980 590 770 1860 73 663 1283 2” 3”
3000 1250 2750 525 2225 675 925 2075 154 829 1524 2” 4”
4000 1450 2880 590 2290 740 990 2140 137 912 1707 2” 4”
5000 Ø 1600 1600 2990 645 2345 795 1045 2195 125 975 1845 2” 4”

77
ACQ. REF. ZB VT
VERTICAL GALVANIZED CHILLED WATER TANK BOX INSULATION

ACQ. REF. ZB VT
Capacity
(BOX FIXED INSULATION)

[liters] ART. NR. Price [€]

100 3001162310001 356,00


200 3001162310002 472,00
300 3001162310003 584,00
500 3001162310004 849,00
800 3001162310005 1.215,00
1000 3001162310006 1.299,00

PROMPT DELIVERY
Grey highlighted products are
dispatched in 1-5 working days.
(Delivery time excluded)

WORKING PRESSURE OPERATING TEMPERATURE

Pmax Tmax
6 bar -10° / +50° C

Technical descriptions Application Insulation


Chilled tanks are used for installations in order to increase the thermal Storage of chilled water for Air Conditioning installations. Injected polyurethan with a special products which eases the removal
inertia and, for those installations with low water-capacity, avoiding of the insulation at the end of the technical lifetime of the product..
that the chilling generator is continually working. External lining
These tanks are galvanized inside and outside, with immersion in Galvanized sheet cover. Color grey. Warranty
a pool of fused zinc with pureness over 98,25% (Uni EN 1179). 2 years
See general sales terms and conditions.

De
Df

(2)

H4 (3) (7) (4)

H3 (8)
A

CONNECTIONS
H

1 Drain
2 Safety valve
3
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

4
Connections to the system
H2 (5) (6) 5
6
7
Instrumentation 1/2’’ gas F
H1 (1) 8

Capacity Df De H A H1 H2 H3 H4 1-2 3-4-5-6


[liters] [mm] Connections Gas F

100 400 457 1007 1015 73 287 592 792 1” 1/4 1” 1/2
200 450 513 1407 1458 68 297 927 1177 1” 1/4 1” 1/2
300 550 620 1519 1641 129 404 994 1244 1” 1/4 2”
500 650 720 1811 1949 121 441 1241 1491 1” 1/4 3”
800 750 830 2108 2266 108 458 1458 1758 1” 1/4 3”
1000 850 930 2162 2354 96 479 1479 1779 1” 1/2 3”

78
ACQ.R/C GB VT
VERTICAL INERTIAL HOT/COLD WATER TANK BOX

ACQ. R/C. GB VT
Capacity
(BOX WITHOUT INTERNAL COATING)

[liters] ART. NR. Price [€]

100 3001162310501 327,00


200 3001162310502 434,00
300 3001162310503 537,00
500 3001162310504 743,00
800 3001162310505 1.064,00
1000 3001162310506 1.139,00

WORKING PRESSURE OPERATING TEMPERATURE

Pmax Tmax
6 bar -10° / +95° C

Technical descriptions Application Insulation


These tanks are used for the accumulation for hot or cold water heating Storage of chilled water for Air Conditioning installations. Expanded solid Polyurethane, ecological an without damageable gas
system. In this way they avoid that the generator or compressor is for the environment. Surfaces are treated with a special stain-remover
continually working. External lining that makes easy the remove of the insulation at the end of the technical
This item is manufactured in raw carbon steel on the inside with anti- Galvanized sheet cover. Color grey. life of the product.
rust finish on the connections. They do not need any internal anti-
corrsion treatment since only primary circuit (heating) water can Warranty
be stored. 2 years
See general sales terms and conditions.

De
Df

(2)

H4 (3) (7) (4)

H3 (8)
A

CONNECTIONS
H

1 Drain
INERTIAL
TANKS
2 Safety valve
3
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

4
Connections to the system
5 H2 (5) (6)
6
7
Instrumentation 1/2’’ gas F
8 H1 (1)

Capacity Df De H A H1 H2 H3 H4 1-2 3-4-5-6


[liters] [mm] Connections Gas F

100 400 457 1007 1015 73 287 592 792 1” 1/4 1” 1/2
200 450 513 1407 1458 68 297 927 1177 1” 1/4 1” 1/2
300 550 620 1519 1641 129 404 994 1244 1” 1/4 2”
500 650 720 1811 1949 121 441 1241 1491 1” 1/4 3”
800 750 830 2108 2266 108 458 1458 1758 1” 1/4 3”
1000 850 930 2162 2354 96 479 1479 1779 1” 1/2 3”

79
VASO MEMB. V PED VT
VERTICAL PAINTED DIAPHRAGMS EXPANSION VESSEL WITH MEMBRANE (DIR. 97/23/CE-P.E.D.)

Capacity VASO MEMB. V PED VT


[liters] CODICE Price [€]
50 3911162241007 111,00
80 3911162241002 143,00
100 3911162241003 147,00
200 3911162241004 343,00
300 3911162241005 535,00
500 3911162241006 769,00
Accessories see page 84

WORKING PRESSURE
Pmax 10 bar

Technical descriptions Documents attached


V PED VT Diaphragms expansion vessels with membrane are used for Material • CE Certificate
lifted water system and they represent a pressurised water lung that, if External cover : painted carbon steel • User Instructions
duly dimensioned , reduces pump cycling.
The peculiarity of this product is the physic separation between water Diaphragms Warranty
and air made by the diaphragms. Elastic EPDM foodstuff membrane suitable for drinking water. 2 years
See general sales terms and conditions.
Application Certifications
Perfect to ensure water deliveries to the top floors of the building or V PED VT Diaphragms expansion vessels with membrane are preduced
to work in case of insufficient water supplied by waterworks, or to in accordance with safety disposal of Direttiva 97/23/CE (P.E.D.) in
stabilize pressure in the domestic water supply by absorbing expansion terms of pressurized.
when the water is heated. They are CE labelled.

De

(1)

Temp.
Capacity De H H1 1 2 3
min/max
[liters] [mm] Connections Gas °C
50 400 627 91 1” M - -10/+99
H

Air inlet valve


80 455 741 88 1” M - -10/+99
100 450 872 88 1/2” 1” M Water -10/+99
200 550 1104 68 1/2” 1” 1/4 F in/out Air inlet -10/+99
Instrumentation
300 650 1254 150 1/2” 1” 1/4 F valve 0/+50
H1

500 750 1511 144 1/2” 1” 1/4 F 0/+50


(3)

(2)
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

VASO MEMB. V PED • PAINTED EXPANSION VESSEL WITH MEMBRANE (DIR. 97/23/CE-P.E.D.)

350

355

1”
WORKING PRESSURE OPERATING TEMPERATURE Liters ART. NR. VERSION Price [€] Gas M
Pmax 8 bar Tmax -10/+99 °C 24 3901190610001 Painted 26,00

80
VASO MEMB. V PED OR
HORIZONTAL PAINTED DIAPHRAGMS EXPANSION VESSEL WITH MEMBRANE (DIR. 97/23/CE-P.E.D.)

Capacity VASO MEMB. V PED OR


[liters] CODICE Price [€]
50 3911161341007 117,00
80 3911161341002 149,00
100 3911161341003 152,00
200 3911161341004 359,00
300 3911161341005 567,00
500 3911161341006 782,00
Accessories see page 84

WORKING PRESSURE
Pmax 10 bar

Technical descriptions Documents attached


V PED OR Diaphragms expansion vessels with membrane are used for Material • CE Certificate
lifted water system and they represent a pressurised water lung that, if External cover : painted carbon steel • User Instructions
duly dimensioned , reduces pump cycling.
The peculiarity of this product is the physic separation between water Diaphragms Warranty
and air made by the diaphragms. Elastic EPDM foodstuff membrane suitable for drinking water. 2 years
See general sales terms and conditions.
Application Certifications
Perfect to ensure water deliveries to the top floors of the building or V PED OR Diaphragms expansion vessels with membrane are preduced
to work in case of insufficient water supplied by waterworks, or to in accordance with safety disposal of Direttiva 97/23/CE (P.E.D.) in
stabilize pressure in the domestic water supply by absorbing expansion terms of pressurized.
when the water is heated. They are CE labelled.

(3)
Temp.
Capacity De H L 1 2 3
min/max
[liters] [mm] Connections Gas °C
50 400 424 538 1” M - -10/+99
Air inlet valve (1) (2)
De

H
80 455 478 655 1” M - -10/+99
100 450 473 783 1/2” 1” M Water -10/+99
200 550 583 1066 1/2” 1” 1/4 F in/out Air inlet -10/+99
Instrumentation
300 650 807 1080 1/2” 1” 1/4 F valve 0/+50
500 750 900 1350 1/2” 1” 1/4 F 0/+50
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

MOTOR SUPPORT PLATE MOTOR SUPPORT PLATE


50/80/100/200 liters 300/500 liters
WATER PRESSURE

234
183
40

TANKS
36

63÷157

N°2 2holes
fori ØØ10
10 N°N°
2 holes
2 foriØØ9 9
142 80
62÷146
65
11
88÷175
10

49

205
68÷135
180

11
10

72÷135 84÷172

81
VASO MEMB. Z PED VT
VERTICAL GALVANIZED DIAPHRAGMS EXPANSION VESSEL WITH MEMBRANE (DIR. 97/23/CE-P.E.D.)

Capacity VASO MEMB. Z PED VT


[liters] CODICE Price [€]
50 3911161991007 111,00
80 3911161991002 135,00
100 3911161991003 168,00
200 3911161991004 345,00
300 3911161991005 556,00
500 3911161991006 791,00
Accessories see page 84

WORKING PRESSURE
Pmax 10 bar

Technical descriptions Certifications


Z PED VT Diaphragms expansion vessels with membrane are used for Material Z PED VT Diaphragms expansion vessels with membrane are preduced
lifted water system and they represent a pressurised water lung that, if External cover : galvanized carbon steel in accordance with safety disposal of Direttiva 97/23/CE (P.E.D.) in
duly dimensioned , reduces pump cycling. terms of pressurized.
The peculiarity of this product is the physic separation between water Diaphragms They are CE labelled.
and air made by the diaphragms. Elastic EPDM foodstuff membrane suitable for drinking water.
Documents attached
Application • CE Certificate
Perfect to ensure water deliveries to the top floors of the building or • User Instructions
to work in case of insufficient water supplied by waterworks, or to
stabilize pressure in the domestic water supply by absorbing expansion Warranty
when the water is heated. 2 years
See general sales terms and conditions.

De

(1)

Temp.
Capacity De H H1 1 2 3
min/max
[liters] [mm] Connections Gas °C
H

50 400 627 91 1” M - -10/+99


Air inlet valve
80 455 741 88 1” M - -10/+99
100 450 872 88 1/2” 1” M Water -10/+99
200 550 1104 68 1/2” 1” 1/4 F in/out Air inlet -10/+99
Instrumentation
300 valve
H1

650 1254 150 1/2” 1” 1/4 F 0/+50


500 750 1511 144 1/2” 1” 1/4 F 0/+50
(3)

(2)
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

VASO MEMB. V PED • GALVANIZED EXPANSION VESSEL WITH MEMBRANE (DIR. 97/23/CE-P.E.D.)

350

355

1”
WORKING PRESSURE OPERATING TEMPERATURE Liters ART. NR. VERSION Price [€] Gas M
Pmax 8 bar Tmax -10/+99 °C 24 3901190600001 Galvanized 46,00

82
VASO MEMB. Z PED OR
HORIZONTAL GALVANIZED DIAPHRAGMS EXPANSION VESSEL WITH MEMBRANE (DIR. 97/23/CE-P.E.D.)

Capacity VASO MEMB. Z PED OR


[liters] CODICE Price [€]
50 3911160991007 117,00
80 3911160991002 145,00
100 3911160991003 174,00
200 3911160991004 380,00
300 3911160991005 581,00
500 3911160991006 818,00
Accessories see page 84

WORKING PRESSURE
Pmax 10 bar

Technical descriptions Certifications


Z PED OR Diaphragms expansion vessels with membrane are used for Material Z PED OR Diaphragms expansion vessels with membrane are preduced
lifted water system and they represent a pressurised water lung that, if External cover : galvanized carbon steel in accordance with safety disposal of Direttiva 97/23/CE (P.E.D.) in
duly dimensioned , reduces pump cycling. terms of pressurized.
The peculiarity of this product is the physic separation between water Diaphragms They are CE labelled.
and air made by the diaphragms. Elastic EPDM foodstuff membrane suitable for drinking water.
Documents attached
Application • CE Certificate
Perfect to ensure water deliveries to the top floors of the building or • User Instructions
to work in case of insufficient water supplied by waterworks, or to
stabilize pressure in the domestic water supply by absorbing expansion Warranty
when the water is heated. 2 years
See general sales terms and conditions.

(3)
Temp.
Capacity De H L 1 2 3
min/max
[liters] [mm] Connections Gas °C
50 400 424 538 1” M - -10/+99
Air inlet valve (1) (2)
De

H
80 455 478 655 1” M - -10/+99
100 450 473 783 1/2” 1” M Water -10/+99
200 550 583 1066 1/2” 1” 1/4 F in/out Air inlet -10/+99
Instrumentation
300 650 807 1080 1/2” 1” 1/4 F valve 0/+50
500 750 900 1350 1/2” 1” 1/4 F 0/+50
P.E.D. product planned and produced in conformity to the article 3.3 of directive 92/23/CE

MOTOR SUPPORT PLATE MOTOR SUPPORT PLATE


50/80/100/200 liters 300/500 liters
WATER PRESSURE

234
183
40

TANKS
36

63÷157

N°2 2holes
fori ØØ10
10 N°N°
2 holes
2 foriØØ9 9
142 80
62÷146
65
11
88÷175
10

49

205
68÷135
180

11
10

72÷135 84÷172

83
ACCESSORIES FOR PRESSURE TANKS

MANOMETERS
Scale Red signal at Pressure level indicator installed on pressurized equipment
Price
ART. NR. Connections [€] in order to obtain an indication in real time on the tank
[Bar] [Bar]
pressure.
5300000000001 1/4” 0/10 6 12,00 All manometer are supplied with a red coloured indicator
5300000000002 1/4” 0/16 8 12,00 for maximal level.
5300000000003 1/4” 0/16 10 12,00
5300000000004 1/4” 0/16 12 12,00
5300000000005 1/4” 0/10 5 12,00
5300000000006 1/4” 0/16 11 12,00

ELASTIC EPDM FOODSTUFF DIAPHRAGMS


The elastic membrane in EPDM foodstuff use are mounted on
Price
ART. NR. Description [€] membrane autoclaves in order to divide the liquid from the
gaseous phase. Doing so the circulating water is pure giving to
5700000410106 for vessel of 24 lt - 10 units box 70,00 the system the warranty to be suitable for drinking
5700000410002 for vessel from 60 to 80 - produced up to 2002 on request
5700000410107 for vessels 100 lt with flange Ø137 mm - 5 units box 200,00
5700000410003 for vessels 200-300 liters and 100 liters with flange Ø254 mm 89,00
5700000410004 for vessels 500 liters 147,00
5700000410108 for vessel from 50-60 liters - produced up to 2003 - 5 units box 120,00
5700000410109 for vessel from 80 liters - produced up to 2003 - 5 units box 190,00

84
85
TECHNICAL SUPPORT
& REGULATIONS
EXAMPLE OF TECHNICAL SCHEMES

BOLLYTERM HP INSTALLATION

6 5 LEGEND
A Sanitary water Inlet
B Domestic hot water users

B 1 Calorifier
1 7 2 Solar circulation group
2
3 Heat exchanger
4 Electrical immersion
5 Integrated Heat Pump

4 6 Solar panels
7 Anode
3

PUFFERMAS® INSTALLATION
LEGEND
A Sanitary water Inlet
B Domestic hot water users
C To the heating systems
1 Calorifier
2 Gas/Gasoil burner
3 Biomass energy source
4 Opened expansion tank
5 Circulation group
6 Hydraulic safety group
7 7 Solar panels
8 Solar circulation group
4

2 8

9 1 5

3
5
5

B
6
10 A
5

86
EXAMPLE OF TECHNICAL SCHEMES

CALORIFIER EXTRA 2 PLUS INSTALLATION

C
LEGEND
A Sanitary water Inlet
B Domestic hot water users 8
C To the heating systems 1
D 10
D Re-circulation
E Drain
1 Calorifier 13 9
2 Burner 7
3 Expansion tank
4 Circulation group
5 Hydraulic safety group
6 Safety valve 9
7 Thermostat connection
8 Thermometer connection
9 Magnesium anode A
10 Connection for electrical immersion
11 Thermostatic mixer 7
12 Solar panels E
13 Solar circulation group

CALORIFIER EXTRA HP (WITH HEAT PUMP) INSTALLATION

LEGEND
A Sanitary water Inlet
B Domestic hot water users
C Heating systems
D Re-circulation
E Drain
1 Calorifier
2 Heat Pump
3 3 Thermostatic mixer
B 4 Hydraulic safety group
5 Expansion tank
6 Circulation group
7 Mixing group
1 8 Connection for electrical immersion
ANODEN TESTER

D
6

8 6 6
7

C
A
TECHNICAL SUPPORT

4
& REGULATIONS

5
E 2

87
EXAMPLE OF TECHNICAL SCHEMES

PIASTRATERM® INSTALLATION

8
C

1
B

4 10 D

6 4

4
2

3 LEGEND
1 Accumulation tank
2 Burner
9
3 Expansion tank
5
4 Circulation group
A 5 Hydraulic safety group
3
6 Easy Control display
7 Anode
Thermostat mixer with by-pass valve (normally a closed
E 8 one
with 220 volt spool )
9 Safety valve
10 Exchanger
A Sanitary water Inlet
B Domestic hot water users
C To the heating systems
D Re-circulation
E Drain

88
EXAMPLE OF TECHNICAL SCHEMES

BOLLY2 DF INSTALLATION

B
12 11

8
3
9
4 D
16 14
10
LEGEND
A Domestic water inlet 9
4
B Domestic hot water users
15
C To the heating system
2
D Re-circulation 6 9
E Drain
A
1 Calorifier
5 7
2 Burner 3
3 Expansion tank
4 Circulation group E
5 Hydraulic safety group
6 Safety valve (2 fixed coil exchangers and double-bottom)
7 Thermostat connection
8 Thermometer connection
9 Magnesium anode
10 Connection for electrical immersion
11 Thermostatic mixer
12 Solar panel
14 Thermostat connection
15 Thermostat connection
16 Solar circulation group TECHNICAL SUPPORT
& REGULATIONS

Particular of double-bottom in Bolly 2 DF

89
EXAMPLE OF TECHNICAL SCHEMES

COMBI 2 AND COMBI 3 INSTALLATIONS


Combi and Eco Combi are a valid for solar system and allow to combine different energy sources , such as condensation burners ,
fireplaces , stoves etc,

With Combi and Eco Combi you can use up to 4 energy sources considering also the electrical sources to combine production of hot
sanitary water and domestic heating. In the following drawing you’ll find :

• connection of solar system to the lower coil


• connection to biomass generator (fireplace, pellets stove, wood stove ) to the storage
• connection of traditional burner to the upper part of the tank:
1) Hydraulic separation on the 3 energy sources circuits;
2) Optimization of the stratification in the internal storage;
3) Use of the COMBI and ECO COMBI storage as thermal absorber (as far as biomass generator is concerned) and as
energy storage ( as far as solar panels are concerned)

Installation Drawing with COMBI2

Storage water is heated by solar panels , by biomass generator


5
or by traditional burner.
While heating system is directly connected with the accumulator
Integrated Stainless Steel or Polywarm Water Heater contains
B Sanitary Hot Water.
The system is controlled by a BASIC Electronic Display , while
6 bar
biomass generator pump is controlled by a bulb thermostat.
A The thermostat controls circulation pumps of domestic heating.
The proposed drawing can be used both with radiators’ heating
6
7 system and with floor heating system, inserting a thermostatic
control.
The Multi Heat Energy Buffer COMBI2 is available also in COMBI1
4 version .
8
2 This can integrate only the burner, or the COMBI3 that allows to
combine biomass generator and burner.

OPPURE...
LEGEND
A Domestic cold water inlet
5 B Domestic cold water users
C C Heating system
1 Buffer tank
3 2 Gas/Gasoil burner
5
5
3 Biomassl energy source
4 Opened expansion tank
5 Circulation group
6 Hydraulic safety group
7 Solar panels
8 Solar circulation group

Installation Drawing with COMBI3

Solar panels and biomass energy source will heat the water and
in case of need they will be supported by the traditional burner.
The heating system is directly connected to the storage, the
stainless steel or Polywarm® DHW inner tank will contain sanitary
hot water.
BASIC Electronic Display controls the solar system and traditional
burner pump. Biomass generator pump is controlled by a bulb
thermostat.
The environment thermostat will control circulation pumps of
domestic heating
7
6 The proposed drawing can be used both with radiators’ heating
system and with floor heating system, inserting a thermostatic
control.
B 8

6 bar 4 The Multi Heat Energy Buffer COMBI3 is available also in COMBI2
A and COMBI1 version that can integrate only the burner, or to
combine biomass generator with solar system.
2

LEGEND
5 A Domestic cold water inlet
B Domestic cold water users
1
C Heating system
5
1 Buffer tank
2 Gas/Gasoil burner
C
3
3 Biomassl energy source
4 Opened expansion tank
5
5 5 Circulation group
6 Hydraulic safety group
7 Solar panels
8 Solar circulation group

90
EXAMPLE OF TECHNICAL SCHEMES

ECO-COMBI 2 AND ECO-COMBI 3 INSTALLATIONS

Installation Drawing with ECO-COMBI2

Hydraulic drawing of a Multi-energy water Heater Eco Combi


2 used in a heating system and sanitary hot water production
system having as main energy source a fireplace and solar panel
and as secondary source a pellet stove. This scheme can be used
only if the generator can work with an opened expansion tank ( on
this subject please see what stated by producer)
In such installation , the Multi-energy water Heater Eco Combi
7 2 act as thermal absorber of the heating system and producer of
sanitary hot water
4
LEGEND
8 2
1 Buffer tank
2 Burner for integration

OPPURE...
3 Fireplace or other discontinuous working energy sources
C
4 Expansion tank

5 5 Heating system circulator group

6 Domestic water system circulator group


3 7 Solar panel
5 8 Solar circulation group
5
9 Hydraulic Safety group
10 Expansion tank
5
B A Domestic cold water inlet
6 B Domestic hot water users
A
C Heating system

Installation Drawing with ECO-COMBI3

Solar panels and biomass energy source will heat the water and
in case of need they will be supported by the traditional burner
The heating system is directly connected to the storage. The
corrugated stainless steel coil with its high exchanging area will
ensure production of sanitary hot wate.
BASIC Electronic Display controls the solar system and traditional
burner pump.
Biomass generator pump is controlled by a bulb thermostat.
The environment thermostat controls circulation pumps of
4 domestic heating.
7
The proposed drawing can be used both with radiators’ heating
system and with ground heating system, inserting a thermostatic
control.
8
The Multi Heat Energy Buffer ECO COMBI3 is available also in
ECO COMBI2 that can integrate only the burner, or to combine
biomass generator with solar system.

3
5 LEGEND
A Domestic cold water inlet
C
5 B Domestic cold water users
C Heating system
5 1 Buffer tank
2
2 Gas/Gasoil burner
5 3 Biomassl energy source
1
TECHNICAL SUPPORT

5 4 Opened expansion tank


& REGULATIONS

B
5 Circulation group
6
6 Hydraulic safety group
A
7 Solar panels
8 Solar circulation group

91
HEAT EXCHANGER PRESSURE LOSS
STRAIGHT HEAT EXCHANGERS 0,5 / 0,75 / 1 m2
Flow rate [lt/min]

The following flowcharts report the pressure loss of the extractable curved
legionellosis prophylaxis or straight Cordivari heat exchangers.
0,5 m2 We can easily observe , the pressure fall in relation to the capacity (expressed
in m3/h or in lt/min ).
Obviously you should add to this value the dispersion of the other part of the
system.
[mm.c.a.]

[mbar]
0,75 m2

1 m2

Flow rate [m3/h]

STRAIGHT HEAT EXCHANGERS 1,5 / 2 / 3 m2


Flow rate [lt/min]
0 50 100 150 200 250 300
5000
2
1,5 m
4500 450,0

4000 400,0

3500 350,0
2 m2
3000 300,0
[mm.c.a.]

[mbar]

2500 3 m2 250,0

2000 200,0

1500 150,0

1000 100,0

500 50,0

0 0,0
0 2 4 6 8 10 12 14 16 18
Flow rate [m3/h]

STRAIGHT HEAT EXCHANGERS 4 / 5 / 8 / 10 m2

Flow rate [lt/min]

10 m2

8 m2

4 m2
[mm.c.a.]

[mbar]

5 m2

Flow rate [m3/h]

92
HEAT EXCHANGER PRESSURE LOSS
CURVED LEGIONELLOSIS PROPHYLAXIS CORDIVARI HEAT EXCHANGERS 0,5 / 0,75 / 1 m2
Flow rate [lt/min]

0,5 m2

0,75 m2
[mm.c.a.]

[mbar]
1 m2

Flow rate [m3/h]

CURVED LEGIONELLOSIS PROPHYLAXIS CORDIVARI HEAT EXCHANGERS 1,5 / 2 / 2(Ø 430) / 2,5 / 3 m2
Flow rate [lt/min]
0 50 100 150 200 250 300
7000

6000 2 m2 500,0
ø 430

5000 1,5 m2 400,0


2,5 m2
4000
[mm.c.a.]

300,0
[mbar]

2 m2
2
3000 3m
200,0
2000

100,0
1000

0 0,0
0 2 4 6 8 10 12 14 16 18
Flow rate [m3/h]

CURVED LEGIONELLOSIS PROPHYLAXIS CORDIVARI HEAT EXCHANGERS 4 / 5 / 8 / 10 m2


Flow rate [lt/min]

10 m2

8 m2

4 m2
[mm.c.a.]

[mbar]

5 m2
TECHNICAL SUPPORT
& REGULATIONS

Flow rate [m3/h]

93
HEAT EXCHANGER PRESSURE LOSS
The following flowcharts report the pressure loss of the fixed heat exchangers. We can easily observe , the pressure fall in relation to the capacity (expressed in m3/h or in lt/min )
Obviously you should add to this value the dispersion of the other part of the system.

FIXED EXCHANGERS (BOLLY 1 POLYWARM®/ BOLLY 2 POLYWARM®)


Flow rate [lt/min]
0 20 40 60 80 100 120 140
400 Exchanger Pressure Loss for :
4000
BOLLY1 WSB - WSC
350
BOLLY2 WSB - WSC (lower exchanger)
3500

300
3000

250 2500

[mm.c.a.]
[mbar]
]

200 2000
[

150 1500

100 1000

50 500

0 0
0 1 2 3 4 5 6 7 8 9

Flow rate [m3/h]

FIXED EXCHANGERS (BOLLY 2 POLYWARM®)


Flow rate [lt/min]
0 20 40 60 80 100 120 140
200
2000
Exchanger Pressure Loss for :
180 BOLLY2 WSB - WSC (Upper Exchanger)

160

1500
140
[mm.c.a.]

120
[mbar]

100 1000

80

60

500
40

20

0 0
0 1 2 3 4 5 6 7 8 9

Flow rate [m /h] 3

FIXED EXCHANGERS (BOLLY 1 STAINLESS STEEL - BOLLY 2 STAINLESS STEEL)


Flow rate [lt/min]
0 20 40 60 80 100 120 140
550
Exchanger Pressure Loss for :
BOLLY1 XSB - XSC
500
5000 BOLLY2 XSB - XSC (lower exchanger)
450

400
4000

350
[mm.c.a.]
[mbar]

300 3000
]

250
[

200 2000

150

100 1000

50

0 0
0 1 2 3 4 5 6 7 8 9
Flow rate [m /h] 3

94
HEAT EXCHANGER PRESSURE LOSS

FIXED EXCHANGERS (COIL VERSION BUFFER)


Flow rate [lt/min]
0 20 40 60 80 100 120 140
450
4500 Exchanger Pressure Loss for :
PUFFER CS

15 00
400

20
4000

00
50 0
350
3500

00
300
3000

10

[mm.c.a.]
250 0
80
[mbar]

2500

200
0

2000
30

150 1500

100 1000

50 500

0 0
0 1 2 3 4 5 6 7 8 9

Flow rate [m3/h]

FIXED EXCHANGERS (STRATIFICATION BUFFER)


Flow rate [lt/min]
0 10 20 30 40 50 60 70 80 90

Exchanger Pressure Loss for :


800 PUFFER 2 STRATIFICATION BUFFER
.

8000
inf
00
10

700
7000
.

600
inf

6000
0
80

.
up
[mm.c.a.]

500
[mbar]

5000

0 0s
01
400 80 4000

300 3000

200 2000

100 1000

0 0
0 1 2 3 4 5 6 7 8 9

Flow rate [m3/h]

EXTRACTABLE COPPER FINNED COILS (EXTRA PLUS)


Flow rate [lt/min]

Exchanger Pressure Loss for :


0 5 10 15 20 25 EXTRA PLUS
500
5000

450
3,17
400
4000

350
2,63
2,27
[mm.c.a.]

300
[mbar]

3000

250
0,94
200
1,58 2000

150

100
0,76
1000
TECHNICAL SUPPORT

50
& REGULATIONS

0 0
0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6

Flow rate [m3/h]

95
HEAT EXCHANGER PRESSURE LOSS

LOWER FIXED EXCHANGERS (COMBI 2 - 3)


Flow rate [lt/min]

0 20 40 60 80 100 120 140 Exchanger Pressure Loss for :


1100 COMBI 2 - 3 XC / WC VT

1000
10000

900

800 8000

700

600

[mm.c.a.]
6000
[mbar]

500

400 4000

300

200 2000

100

0 0
0 1 2 3 4 5 6

Flow rate [m3/h]

UPPER FIXED EXCHANGERS (COMBI 3)


Flow rate [lt/min]
0 20 40 60 80 100 120 140
900 Exchanger Pressure Loss for :
9000 COMBI 3 XC / WC VT

800
8000

700
7000

600 6000

500 5000
[mm.c.a.]
[mbar]

400 4000

300 3000

200 2000

100 1000

0 0
0 1 2 3 4 5 6

Flow rate [m3/h]

96
HEAT EXCHANGER PRESSURE LOSS

LOWER FIXED EXCHANGERS (ECO-COMBI 2 - 3)


Flow rate [lt/min]

Exchanger Pressure Loss for :


0 10 20 30 40 50 60 70 80 90 ECO-COMBI 2 -3

800 8000

700 7000

600 6000

500 5000

[mm.c.a.]
[mbar]

400 4000

300 3000

200 2000

100 1000

0 0
0 1 2 3 4 5

Flow rate [m3/h]

UPPER FIXED EXCHANGERS (ECO-COMBI 3)


Flow rate [lt/min]

0 10 20 30 40 50 60 70 80 90 Exchanger Pressure Loss for :


600 ECO-COMBI 3
6000

500 5000

400 4000
[mm.c.a.]
[mbar]

300 3000

200 2000

100 1000

0 0
0 1 2 3 4 5

Flow rate [m3/h]


SUPPORTO TECNICO
E NORMATIVA

97
COMPANY CERTIFICATES

Quality Certificate UNI EN ISO 9001:2008 Environmental managing System Certificate UNI EN ISO
14001:2004

ITALIANS AND EUROPEAN LAWS AND REGULATIONS


Main laws and regulations concerning production and installation of pressurised tanks:

• prEN 12897 – technical details for storage of sanitary hot water and indirect heating systems

• Disposals 97/23/CE (P.E.D.) for pressurised equipment


• Domestic Regulation feb 25th, 2000 n 93 – Appliance 97/23/CE disposal

• DGLS february 25th 2000, n. 93 – Application of 97/23/CE.


• Decrete 1/12/2004 n. 329 - Installation of equipment and pressurized ensemble

• Law January 9th 1991, n. 10 – National energy plan, for energy saving and energy development for renewable energy source.

• D.P.R. 26-8-1993 n. 412 – applying regulation law 10/91.

• D.L. 25/01/1992, n.108 – application of disposal n. 89/109/CEE concerning material and object destinated to get in touch with foodstuffs

• D.M. del 21/03/1973 – Decrete Law concening water for human consumption

• D.M. 174 del 06/04/2004 Decrete Law concening water for human consumption delayed up to July 2007

• Disposals 87/404/CE air compressor tanks planning and production

98
PRODUCTS CERTIFICATIONS

CE Certificate in accordance with 97/23/CE regulations relevant CE Certificate in accordance with requirements of 97/23/CE CE Certificate in accordance with requirements of 97/23/
to autoclaves regulations for pressurized tanks (equipped autoclave) CE regulations for pressurized tanks (exchanging diaphragm
autoclaves)

Certificate in conformity for Domestic Hot Water of organic Test report of internal treatment for food use Polywarm® in Test report for gasket in silicone for food use in accordance with
coating for food uses Polywarm® granted by IPL (Institut Pasteur accordance with D.M. nr. 174 del 06/04/2004. D.M. nr. 174 del 06/04/2004.
de Lille)
SUPPORTO TECNICO
E NORMATIVA

99
REGULATIONS FOR A CORRECT INSTALLATIONS OF PRESSURE TANKS

INSTALLATION
Pressure tanks have always to be protected from weather condition, placed on a solid ground basis, checking before installing that there is enough space to extract and change the magnesium anode and the
other components and to ease the inspections. The location room for the pressure tank should have a sufficient access in order to avoid any destruction either in entry or exit of the tank.

OVERPRESSURE:
If the sanitary water installation exceeds the admissible values of pressure of the calorifier, a pressure regulator as far away as possible from the calorifier has to be installed.

• Calorifier with primary circuits fluid with temperature below 100° C


To avoid damaging on products due to sudden changes of pressure, it is always necessary to provide an expansion system.
According to “Raccolta R fasc. (R-1a)” Water Heater with primary circuit temperature below or equal to boiling secondary fluid at 0.5 bar pressure this expansion system can simply consist in a safety valve,
counterwight? or spring-loaded, which port has to be a diameter in millimetres not lower than:

where V is Volume of Calorifier in liters, minimum diameter 15mm. The valve must be calibrated at a pressure not exceeding the maximum working pressure of the calorifier and connected without any shut
off device.
Besides the safety valve is however recommended to install a closed expansion vessel with atoxic membrane, in order to avoid a continuous opening of valve.

• Calorifiers with primary circuit supplied by steam or hot water


a proper dimensioned expansion vessel must always be installed.On the secondary circuit of these calorifiers,
Furthermore, “Raccolta R. fasc. R-3-E” require that waterheaters, aimed for D.H.W. and technological use, whose heat exchanger is supplied by steam or hot water, must be compliant with the following
particular disposition .

Safety devices to be applied to the heater must be composed by one or more safety valve,, having discharge capacity related to the thermal power of heating coil coupled with thermal blowdown valve, or
valves, sized to same thermal power. It is allowed, if possible, to change the above mentioned blowdown valve with a “fuel shut-off” valve applied on the burner of steam, or hot water generator
In any case, as protection device, an automatic thermal circuit breaker lockout, operating on a thermal control device installed on the primary circuit of waterheater, must be applied.
Waterheater must have control device (thermometer / manometer) on the upper part, or on the DHW outlet.

CORROSION PROTECTION
To avoid electro-chemical corrosion - and in order to comply with the warranty’s conditions too - the cylinder has to be installed always with its cathode protection. Cordivari Srl gives according to the tank
version:
• Anoden-tester magnesium bar, which allows to check the real consumption of the magnesium bar just pushing on the "tester button".
• Simpletest Anode (easy checking acting on the relative valve - any water outlet indicates the immediate substitution of the anode)
• Standard anode, where it is necessary the visual checking of the magnesium bar.
As accessory (only for Polywarm® version) also available the electronic anode which do not need to be replaced and need only an uninterrupted electricity. It is also necessary, for warranty purposes too, that
the water never exceeds the values indicated on DPR 236/88. To avoid any galvanic currents tank grounding have to be done.

LEGIONELLOSIS
Legionellosis can widespread with temperatures between 30° and 45°. To avoid any risk water tank has to be accumulated at 60° and never reach temperature lower than 50°.

REFRIGERATED WATER ACCUMULATION TANK


• Do not use the tank for movable installation or for transportation
• Always install the tank as leveled
• To avoid any galvanic currents tank grounding have to be done.
• Before close the tank into rooms or other space it should be tested before
• In case of installation of the tank in room or loft it should equipped with apposite drains in order to avoid lack of water

ACCUMULATION SC TANKS
• On stainless steel tanks the composition of the water inside it should not exceed the value established by DPR 236/88;
• On Stainless steel tanks never use iron or galvanized joints
• Do not use the tank for movable installation or for transportation
• Always install the tank as levelled
• To avoid any galvanic currents tank grounding have to be done.
• Before close the tank into rooms or other space it should be tested before
• In case of installation of the tank in room or loft it should equipped with apposite drains in order to avoid lack of water

100
GENERAL SALES CONDITIONS AND WARRANTY

Sales of Cordivari’s products are made according to the conditions listed below. Exception should be agreed in written with Cordivari Srl.

1. Shipment
Goods are transported at buyer’s risk and peril, even if they are shipped free of carriage. Goods have to be checked at the delivery about unaltered packaging, missing or confused items in the presence
of the forwarder. Any claim has to be immediately communicated to the forwarder by appointing the shipment’s document and by registered mail within 3 days (otherwise the forwarder is cleared of his
responsibilities).

2. Delivery terms
Delivery terms are indicative. Failure to comply with the agreed delivery terms for any reasons will not entitle the buyer to any compensation, cancellation or modification of the order without our prior
consent. In case exceptional events like weather disaster, strikes or missing raw materials not predictable, Cordivari will decide the best decision to take. If the ordered goods will not be collected in the time
established, this material will be stored at buyer’s costs and risks.

3. Weight, measures, surfaces


Weights, measures, surfaces, shapes, sizes and other figures related to the products are merely indicative and Cordivari Srl may at any time modify them.

4. Order cancellation or modification


No orders shall be cancelled or modified even partially without the consent of Cordivari Srl. It will not be possible to modify the order when the production has already started. Some cost due to the
modifications or cancellation will be charge to the buyer.

5. Warranty
On all tanks in Stainless Steel 316L the warranty is 5 years
On all tanks with Polywarm coating the warranty is 5 years
The warranty is valid for the hole caused by corrosion and valid only if the products is set with the cathode protection in an efficient and permanent way. This last one has to be frequently checked. The
installation should respect the parameters in force about overpressure, corrosion, legionelosys according to the prescriptions previously listed in this catalogue. Basically the sanitary water productions units
have to comply with the UNI CTI 8065 directive about water treatment. The warranty is no more valid in case of non observance of this norm.
Warranty will be applicable at the following conditions:
- Materials must have been stored in good conditions and protected for the inclemency of the weather before installation
- Product did not have damages during transport, handling or installation.
- No alterations or reparations must be done without the prior consent of the seller
- The installation must have been done by professionals and in conformity with all instructions and standards written on the technical data sheets provided by Cordivari Srl.
- Accessories used must be original Cordivari materials
- The buyer must have paid all the bills within the pre-established deadlines
- No aggressive chemical substances must have been added to the water.
- Working pressure and temperature shown in the catalogue must correspond to the current usage pressure and temperature.
The warranty doesn't cover construction or dismantling cost to move the product from/to the installation place.
For all others accessories and items the warranty is 2 years, applicable at the same conditions listed above.

6. Payments
All invoices have to be paid according to agreed deadline. Any delay, even partially may suspend the planned deliveries. Overdue interest could be charged at current rates.

7. Goods’ property
Cordivari Srl remains owner of the delivered goods until they are not completely paid. In case of failure to proceed with the payment, Cordivari Srl can ask for the immediate return of the delivered goods,
keeping the partial paid amount as indennity, or even ask for a bigger amount should the damage be higher.

8. Prices
Prices are not binding and can be modified without communication at anytime. Stated prices are ex-works, except in case of written agreements. For some voluminous delivery Cordivari may charge some
packing extra-costs.

9. Orders
The minimum order is Euro 2.000,00. Given orders are binding to the buyer, who acknowledges of all our sales conditions.

10. Court authority


Controversy will be settled by Teramo court.

11. Notes
Translation of Cordivari General sales conditions and warranty terms, reported in this page, has been done from the Italian version. In case of possible controversy, the official Cordivari General sales condition
and warranty terms are the one reported in the Italian language, stated at the back of the Italian catalogues.

© Copyright Cordivari S.r.l.


All rights such as reproduction, diffusion and translation are reserved. Any part of this brochure can be reprinted or reproduced to any other form without a written authorization by Cordivari Srl. The present
catalogue substitutes and invalidates all previous editions. Cordivari reserves the right to modify in every moment products and figures reported in the catalogue and has no responsibility for any press
mistake.
TECHNICAL SUPPORT
& REGULATIONS

101
Mod. 03.10-E

CORDIVARI S.r.l. - Z. I. Pagliare 64020 Morro D’Oro (TE) - ITALY


CALORIFIERS - PRESSURE TANKS
C.F. Part.IVA e Reg.Imprese TE 00735570673 Rev. 04
Cap.Soc. Euro 4.000.000,00 i.v.
Tel: +39 085 80.40.713 - Fax: +39 085 80.40.273
PRICE REQUEST del 21/05/2010

DATE

COMPANY
NAME

CALORIFIERS BUFFERS COMPRESSED AIR RECEIVERS CHILLED WATER TANK


PRODUCT
MULTI-HEAT ENERGY D.H.W. INERTIAL
CATEGORY COMBI / ECO-COMBI ACCUMULATION TANK TANK NO PED

DESCRIPTION

DRAWING
TECHNICAL DETAILS
CAPACITY [lt]
DIAMETER [mm]
HEIGHT [mm]
VERTICAL
HORIZONTAL

POLYWARM®
STAINLESS STEEL
PRESSURE TEMPERATURE

SECONDARY SYSTEM (SANITARY)

©COPYRIGHT: This form cannot not be forwarded of reproduced without written authorization issued by Cordivari Srl
LIQUID PRESSURE
PRIMARY SYSTEM (HEATING)

LIQUID PRESSURE

INSULATION

REMARKS

&AXsEXPORT CORDIVARIIT

102
NOTES
5-2010 6301381340052 GB
DISCOVER THE WIDE RANGE OF CORDIVARI PRODUCTS:

SOLAR TANKS CHIMNEY FOOD COMPRESSED


DESIGN
THERMAL PIPES CONTAINERS AIR
RADIATORS
SYSTEM RECEIVERS

CALORIFIERS
CORDIVARI srl
Zona Industriale Pagliare
64020 Morro D’Oro (TE)
ITALY
C.F. Part.IVA e Reg.Impr.
TE n. 00735570673
Cap.Soc.`4.000.000,00 i.v.
Tel: +39 085 80.40.713
Fax: +39 085 80.40.273
www.cordivari.it
export2@cordivari.it

You might also like