Water Meter

A Water Meter is a mechanical device to measure the flow rate of a water pump.
[The Water meter comprises a rotor with helical blades inserted axially in the flow, much like a ducted fan; it can be
considered a type of turbine water meter. They are commonly referred to as helix meters, and are popular at larger sizes.]

This installation guide is intended for


experienced and trained personnel
only.

Changing the measuring insert is only


Attention
Attention allowed for authorized personnel!
Damaging the seal or sticker will
immediately void the warranty.

Installation instructions

• The water meter can be installed in any position • The flow meter must always be filled full
with the direction of the flow as indicated by with water
the arrow cast in the meter body with the
register face upwards • The flow meter must be protected against
pressure shocks in the pipe
• Thoroughly flush the pipes before
installing the meter • The pipe pressure and water temperature
must not exceed the values shown on the
• It is important that you observe the required type plate
calming section (see below)
• All flow control components (e.g. valves)
• If the water is soiled, fit a strainer in the should be installed after the flow meter
pipe before the meter

• Install the water meter in a frost proof position at


the lowest possible point of the installation
to avoid air accumulating Working conditions

• The water meter must be installed in the Water temperature: 0 … 40°C


pipe without mechanical stress (from bended Water pressure: up to 16 bar
or twisted connection pipes, etc.)

• Flange seals must not protrude into the


pipe

• On completion of installation, fill the pipe


slowly to prevent pressure shocks damaging
the measuring insert

V14110
6

All specifications and information are given with good intent, errors are possible and products may be subject to change without notice.
Pictures may differ from actual products depending on local market requirements and regulations.
Water Meter
Calming sections

The water meter must have 10 nominal diameters straight pipe ahead of the meter and 5 nominal
diameters straight pipe after to insure a correct flow measurement.

Technical Data
Nominal Diameter DN 40 65 80 100 125 150 200
Maximum flow rate m³/h Q_max 20 50 80 120 200 300 500
Nominal flow rate m³/h Q_n 10 25 40 60 100 150 250
Transition flow rate m³/h Q_t 3.0 5.0 8,0 12 20 30 50
Minimum flow rate m³/h Q_min 0.7 0.75 1.2 1.8 3.0 4.5 7.5
Maximum reading m³ 999999.999 9999999.99
Minimum reading m³ 0.001 0.001 0.001 0.001 0.001 0.01 0.1

V14110
6

All specifications and information are given with good intent, errors are possible and products may be subject to change without notice.
Pictures may differ from actual products depending on local market requirements and regulations.
Water Meter
Dimensions

Nominal Diameter DN 40 65 80 100 125 150 200


Length mm L 260 200 225 250 250 300 350
(250*) (300*) (360*) (430*)
Height mm H 225 242 252 262 275 325 355
Working height mm H1 303 313 323 333 346 396 436
Height mm G 360 360 360 360 360 420 420
Outside Diameter mm D 150 185 200 220 250 285 340
Circlediameter mm D1 110 145 160 180 210 240 295
Connecting bolt quantity nxM 4xM16 4xM16 8xM16 8xM16 8xM16 8xM20 12xM2
*Other body length for selection

Accuracy Curve

V14110
6

All specifications and information are given with good intent, errors are possible and products may be subject to change without notice.
Pictures may differ from actual products depending on local market requirements and regulations.
Water Meter
The Accuracy Curve shows the imprecision in percent for different flow rates. In regular operation
the deviation is between -2% and +2%.

Special Version (with reed switch pulser)

- It is a turbine Removable Element water meter for industrial and irrigation application in size
40mm to 150mm for cold meter

- The special version WP-40 ~ 150 water meter is equipped with a reed switch assembly which
can be connected to remote reading systems after breaking the meter seal.

- The reed switch pulser sends out electrical signals per a preset water quantity requiring
power from an external source

Working Conditions

Working conditions, dimensions and technical data are the same as the common water meter

Electric Data

Data Output Option

- The special meter comes in two model variations, which indicate different pulse rates

- To choose the variation best suited to your needs, please consult the table below.

Reed switch pulse A group signals for each


Position of special pointer X0.01 X0.1
Water quantity for each circle 0.1m³ 1m³
DN 40 / 65/ 80 /100 /125 •
DN 150 / 200 •