5mm THK FICEM BOARD

1.6MM THK LEAD

4.5mm THK FICEM BOARD

4" METAL STUD VERTICAL @ 600mm SPACING

4" METAL STUD HORIZONTAL


@ 1200mm SPACING 1.6 MM THK LEAD

4" METAL STUD HORIZONTAL


@1200mm SPACING 4" METAL STUD HORIZONTAL @ 1200mm SPACING

1.6mm THK LEAD

4.5mm THK FICEM BOARD

FFL

ISOMETRIC VIEW DETAIL


SCALE: NTS

DRYWALL SECTION DETAIL


SCALE: NTS