You are on page 1of 7

SPECIFICATION NO.

: C-46201-L179-1 SCHEDULE-
GTP(1)
Page 1 of 3

INSULTOR PACKAGE-C FOR 400 kV D/C TRANSMISSION LINES


ASSOCIATED WITH EAST – WEST TRANSMISSION CORRIDOR
STRENGTHENING SCHEME
(Guaranteed Technical Particulars for Disc Insulators)

Bidder's Name & Address: To


Power Grid Corporation of India Ltd.
Plot No.2, Sector-29,
Gurgaon, Haryana - 122 001

Guaranteed Technical Particulars for Disc Insulators Units:


S. Description Unit 120 KN 160 KN
No. Disc Disc
Insulator Insulator
1. Name & Address of manufacturer

2. Weight of single disc Kg.


3. Size and Designation of pin ball shank mm
4. Diameter of disc mm
5. Tolerance on Diameter + mm
6. Ball to ball spacing between Disc mm
7. Tolerance on spacing + mm
8. Minimum nominal creepage distance of mm
single disc
9. Tolerance on creepage distance + mm
10. Electromechanical Strength of disc kN
11. Material of Shell(Porcelain/Toughened
glass)
12. Head thickness of shell mm
13. Power frequency flashover voltage of
single disc
a) dry kV(rms)
b) wet kV(rms)
14. Power frequency withstand voltage of
single disc
a) dry kV(rms)
b) wet kV(rms)
15. Power frequency puncture voltage of kV(rms)
single disc
16. Impulse flashover voltage of single disc
(dry)
a) Positive kV(peak)
b) Negative kV(peak)
17. Impulse withstand voltage of single disc
(dry)
a) Positive kV(peak)
kV(peak)
Section IV – Bidding Forms Insulator Package-C for 400 kV D/C Transmission Lines
associated with East – West Transmission Corridor Strengthening
Scheme
SPECIFICATION NO. : C-46201-L179-1 SCHEDULE-
GTP(1)
Page 2 of 3

S. Description Unit 120 KN 160 KN


No. Disc Disc
Insulator Insulator
b) Negative

Guaranteed Technical Particulars for Disc Insulators Units:


S. Description Unit 120 KN 160 KN
No. Disc Disc
Insulator Insulator
18. Steepness of impulse voltage which the kV/mic
disc insulators can withstand in steep ro sec
wave front test
19. Visible discharge voltage of single disc kV(rms)
(dry)
20. Maximum RIV at 1 MHZ and 10kV AC Micro-
(rms) voltage of single disc volts
21. Purity of zinc used for galvanizing %
22. No. of dips in standard preece test
a) Socket No.
b) Ball pin No.
23. Axial and Radial run out (According to
IEC)
a) As per pointer A mm
b) As per pointer B mm
24. Drawings enclosed Yes/
No

Date:.................... (Signature)
……….........................................
Place:................... (Printed Name) .........................................
….

(Designation) ....…..........................................

(Common Seal) …..........................................

Section IV – Bidding Forms Insulator Package-C for 400 kV D/C Transmission Lines
associated with East – West Transmission Corridor Strengthening
Scheme
SPECIFICATION NO. : C-46201-L179-1 SCHEDULE-
GTP(1)
Page 3 of 3

INSULTOR PACKAGE-C FOR 400 kV D/C TRANSMISSION LINES ASSOCIATED


WITH EAST – WEST TRANSMISSION CORRIDOR STRENGTHENING SCHEME
(Guaranteed Technical Particulars for Disc Insulators)
Bidder's Name & Address: To. Power Grid Corporation of India
Ltd.
Plot No.2, Sector-29,
Gurgaon, Haryana - 122 001
Guaranteed Technical Particulars of Insulator Strings (with Disc Insulators)
alongwith Hardware Fittings:
Sl. Description Unit Single ‘I’ Double Single Single
No. Suspens- Tension suspens- Tension
ion string String ion pilot String
(1x23) (2x23) string (1x24)
(1x23)
1 Power frequency withstand kV (rms)
voltage of string with arcing
horns, corona control rings/
grading rings under wet
condition
2 Switching Surge withstand
voltage (Wet)
a) Positive kV (peak)
b) Negative kV (peak)
3 Impulse withstand voltage
(dry)
a) Positive kV (Peak)
b) Negative kV (peak)
4 Impulse flashover voltage (dry)
a) Positive kV (Peak)
b) Negative kV (Peak)
5 Minimum Corona extinction kV (rms)
voltage under dry condition
6 RIV at 1 MHZ when the string Microvolt
is energized at 305kV (rms)
under dry condition
7 Mechanical strength of kN
complete insulator string
alongwith hardware fittings
8 Maximum voltage distribution %
across any disc of line to earth
voltage
9 Dimensioned drawings of Yes/No
insulator strings enclosed.
Date: (Signature) ............................................
Place : (Printed Name) ..................................
(Designation) .......................................

Section IV – Bidding Forms Insulator Package-C for 400 kV D/C Transmission Lines
associated with East – West Transmission Corridor Strengthening
Scheme
SPECIFICATION NO. : C-46201-L179-1 SCHEDULE-
GTP(1)
Page 4 of 3

(Common Seal) ....................................

Section IV – Bidding Forms Insulator Package-C for 400 kV D/C Transmission Lines
associated with East – West Transmission Corridor Strengthening
Scheme
SPECIFICATION NO. : C-46201-L179-1 SCHEDULE-GTP(2)
Page 1 of 3

INSULTOR PACKAGE-C FOR 400 kV D/C TRANSMISSION LINES ASSOCIATED


WITH EAST – WEST TRANSMISSION CORRIDOR STRENGTHENING SCHEME
(Guaranteed Technical Particulars for Long Rod Insulators)

Bidder's Name & Address: To


Power Grid Corporation of India Ltd.
Plot No.2, Sector-29,
Gurgaon, Haryana - 122 001

Guaranteed Technical Particulars of Long Rod Insulators:

Sl. Description Unit 120 KN 160 KN


No. Long rod Long rod
Insulator Insulator
1 Name & Address of manufacturer

2 Weight of single unit Kg.


3 Size and Designation of Ball & mm
Socket assembly
4 Core diameter mm
5 Tolerance on Core Diameter +mm
6 Nominal length (Insulation mm
Spacing)
7 Tolerance on Nominal length +mm
8 Number of sheds Nos.
9 Sheds profile (type)
10 Shed spacing mm
11 Shed diameter mm
12 Tolerance on shed diameter +mm
13 Creepage distance mm
14 Tolerance on creepage distance mm
15 Guaranteed mechanical strength kN
16 Routine mechanical load kN
17 Material
a) Insulator
b) End Fittings

18 Power frequency withstand


voltage of single unit
a) Dry kV(rms)
b) Wet kV(rms)

19 Power Frequency flashover


voltage of single unit
a) Dry kV(rms)
b) Wet kV(rms)

20 Impulse withstand voltage of


Section IV – Bidding Forms Insulator Package-C for 400 kV D/C Transmission Lines
associated with East – West Transmission Corridor Strengthening
Scheme
SPECIFICATION NO. : C-46201-L179-1 SCHEDULE-GTP(2)
Page 2 of 3

Sl. Description Unit 120 KN 160 KN


No. Long rod Long rod
Insulator Insulator
single unit (Dry)
a) Positive kV(Peak)
b) Negative kV(Peak)
21 Impulse flashover voltage of
single unit (Dry)
a) Positive kV(Peak)
b) Negative kV(Peak)
22 Purity of zinc used for %
galvanizing and fittings
23 Number of dips which the end Nos.
fittings can withstand in standard
preece test
24 Axial/Radial run out & angular
displacement (According to IEC-
383) mm
a) As per Pointer B Degree
b) Angular displacement
25 Drawing enclosed Yes/No

Date: (Signature) ............................................

Place : (Printed Name) ..................................

(Designation) .......................................

(Common Seal) ....................................

Section IV – Bidding Forms Insulator Package-C for 400 kV D/C Transmission Lines
associated with East – West Transmission Corridor Strengthening
Scheme
SPECIFICATION NO. : C-46201-L179-1 SCHEDULE-GTP(2)
Page 3 of 3

INSULTOR PACKAGE-C FOR 400 kV D/C TRANSMISSION LINES ASSOCIATED


WITH EAST – WEST TRANSMISSION CORRIDOR STRENGTHENING SCHEME
(Guaranteed Technical Particulars for Long Rod Insulators)
Bidder's Name & Address: To
Power Grid Corporation of India Ltd.
Plot No.2, Sector-29,
Gurgaon, Haryana - 122 001
Guaranteed Technical Particulars of Insulator Strings (with Long Rod Insulators)
alongwith Hardware Fittings:
Sl. Description Unit single ‘I’ Double Single Single
No. Suspens- Tension suspens- Tension
ion string String ion pilot String
(1x3) (2x3) string (1x3)
(1x3)
1 Power frequency withstand kV (rms)
voltage of string with arcing
horns, corona control rings/
grading rings under wet
condition
2 Switching Surge withstand
voltage (Wet)
c) Positive kV (peak)
d) Negative kV (peak)
3 Impulse withstand voltage
(dry)
a) Positive kV (Peak)
b) Negative kV (peak)
4 Impulse flashover voltage
(dry)
a) Positive kV (Peak)
b) Negative kV (Peak)
5 Minimum Corona extinction kV (rms)
voltage under dry condition
6 RIV at 1 MHZ when the Microvolt
string is energized at 305kV
(rms) under dry condition
7 Mechanical strength of KN
complete insulator string
alongwith hardware fittings
8 Dimensioned drawings of Yes/No
insulator strings enclosed.
Date: (Signature) ............................................
Place : (Printed Name) ..................................
(Designation) .......................................
(Common Seal) ....................................

Section IV – Bidding Forms Insulator Package-C for 400 kV D/C Transmission Lines
associated with East – West Transmission Corridor Strengthening
Scheme

You might also like