2 TAG: SPFM 001 Specification for 7 Document No IP-DMA-001 3 PID: DMA1 Flow Meters 8 Latest revision B Date 10/07/2020 4 9 Issue status Approved for Quotation 5 10 11 FLOWMETER BODY AND HOUSING 58 TOTALIZER INDICATOR 12 Body/Housing type In-line (std by vendor) 59 Totalizer type N/A 13 End conn nominal size BY VENDOR 150# 60 Enclosure type no/class N/A 14 End conn termn type Flanged Rating R.F. 61 Signal Power source N/A 15 Body wetted material 304 SS 62 Contacts arrangement N/A Quantity N/A 16 Housing material 304 SS 63 Totalizer reset style N/A 17 End termination material 304 SS 64 Integral indicator style N/A 18 65 Cert/Approval type N/A 19 66 Mounting location/type N/A 20 FLOWTUBE ASSEMBLY 67 Enclosure material N/A 21 Flowtube type Parallel curved tubes 68 22 Flowtube diameter BY VENDOR 69 PERFORMANCE CHARACTERISTICS 23 Flowtube material 304 SS 70 Max press at design temp Note 1 At Note 1 24 Permitted flowtube diameter < or = to line nominal size 71 Min working temperature Note 1 Max Note 1 25 72 Mass flow rate accuracy ´+/- 0.1% for liquid and 0.5% for gas 26 73 Density accuracy rating 0.001 g/cm3 for liquid 27 74 Min flow URL Note 1 Max Note 1 28 CONNECTION HEAD 75 Density LRL Note 1 URL Note 1 29 Housing type explosion proof enclosure 76 Sec enclosure press rating Note 1 30 Enclosure type no/class NEMA 4X&7, Class 1,Div 2,Gr. CyD 77 Pressure drop at flow URL Note 1 31 Signal termination type Terminal Block 78 Min ambient working temp Note 1 Max Note 1 32 Cert/Approval type FM explosion proof 79 Contacts ac rating N/A At max N/A 33 Housing material 304 SS 80 Contacts dc rating N/A At max N/A 34 81 Max sensor to receiver Ig Note 1 35 82 36 83 ACCESSORIES 37 REMOTE TRANSMITTER OR COMPUTER 84 Connecting cables length 6 meters 38 Housing type explosion proof enclosure 85 Heating Kit style N/A 39 Measurement compensation Density 86 Calibrator/configurator N/A 40 Output signal type Foundation Fieldbus 87 41 Enclosure type no/class NEMA 4X&7, Class 1,Div 2,Gr. C,D 88 42 Span-zero adjustment Local Keypad, Hand Held & PRM softw 89 SPECIAL REQUIREMENTS 43 Characteristic curve Linear mass flow 90 Custom tag SPFM 001 44 Digital communication std Foundation Fieldbus 91 Reference specification N/A 45 Signal power source 120 VAC, 60 Hz 92 Special preparation N/A 46 Failsafe style Failsafe selectable 93 Compliance standard N/A 47 Integral indicator style LCD Display 94 Calibration report Yes, 10 points mass flow calibration 48 Signal Termination type Terminal Block 95 Software configuration Custom configuration 49 Cert/Approval type FM explosion proof 96 50 Mounting location/type Remote/ 2 in pipe bracket 97 PHYSICAL DATA 51 Failure/Diagnostic action Drive output high 98 Estimated weight Note 2 52 Enclosure material Epoxy coated aluminum 99 Face-to-face dimension Accordance to ASME B 16.10 53 100 Overall height Note 2 54 101 Removal clearance Note 2 55 102 Signal conn nominal size 1/2 in Style NPT(F) 56 103 Mfr reference dwg N/A 57 104 110 CALIBRATIONS AND TEST INPUT OR TEST OUTPUT OR SCALE 111 TAG NO/FUNCTIONAL IDENT MEAS/SIGNAL/TEST LRV URV ACTION LRV URV 112 SPFM 001 Mass flow-Analog output 113 Meas-Analog output 2 114 Meas-Analog output 3 115 Meas-Freq output 1 116 Meas-Freq output 2 117 Measurement-Scale 0 kg/hr 2400 Kg/hr 118 Temp-Digital output 119 Meas-Digital output 120 Density-Digital output 121 Test pressure 122 COMPONENT IDENTIFICATIONS 123 COMPONENT TYPE MANUFACTURER MODEL NUMBER 124 Flowmeter MicroMotion 125 FlowTransmitter MicroMotion 126 127 Rev Date Revision Description By Appy1 Appy2 Appy3 REMARKS Note: 1 Vendor must furnish performance caracterisct.