You are on page 1of 11

·,

,.
Unit Area per M in. of 2 Exits for
Occupant Loads ·, : Unit Area per ..
'
.{J Dwellings
Occupant (sq m)
28
occupants over
10
Occupant (sqm)
18.6
"'; ;

\
-- Hotels, Apartments, Dormitories 18.6 10
18.6
Classrooms 1.8 50
1.9
1 Conference Rms, Exhibit Rms,Gymnasia 1.4 50 1.4
School Shops, Vocational Institutions, 4.6 50 4.6
and Laboratories
Hospitals, Sanitaria 8.4 5 11.1 (sleeping)
Nursing Homes, Children's Homes, 7.4 5 23.1 (inpatient treatment)
Homes for the Aged
3.25 6 v \)
Nurseries for Chi ldren
2.8 so \,)~e..,
Store-Ret ail (Basement & Ground Firs.)

~
2.8

*
Store-Retail (Upper Floors )
Offices/Business
Aircraft Hangars (No repair)
5.6
9.3
46.5
10
30
10
5.6
9.3
s
v
\J
b
- Parking Garages
I Drinking Establishments
18.6
1.4
30
30 1.4 ~~-
~
0-''
-- Kitchens (commercial)
<:$ Warehouses, Mech. Equipment Rooms
18.6
28
50
30
.;'\

~ Garages 9.3 10
Auditoriums, Theaters, Churches, 0.65 50 0.65 ~~·
Reviewing stands, Dance floors, Stadia (0.28 for standing room or waiting space)
Detention & Correctional 11.1
Industrial 9.3
..
Exits
Number of Exits
\ ·, ·' .' ' ·~ ,'.\,\,',
. ·,·. / ' ·~:
'
. <~··,· • . . ·, ... ~

1-10 occu pants 1 2 N/A 1 1


11-499 occupants 2 2 N/A 2 2
500-999 occupants 3 3 N/A 2 3
1,000 or more occupants 4 4 N/A 2 4
Width of Exit shall not be less than total minimum 915 mm - meaN or
occupant load divided by 165 e9resr
Arrangement of Exits
2 exits not less than 1/5 of perimeter not less than 1/2 maximum diagonal
of th e area length of the area
(not less than 1/3 if protected by
automatic sprinkler system)
3 or more exits arranged in a way that of one at least 2 exits shall comply min.
becomes blocked, the others
will be available separation distance requirement
Dist ance to Exits 45 meters (w/o sprinkler system) Assembly, Educational, Business: shall conform w ith NBC shall conform with NBC
60 meters (w/ sprinkler system) 46 meters (w/o sprinkler system) and Fire Code and Fire Code
61 meters (w/ sprinkler syst em )
Child Day Care Centers:
30.Sm(from any room door intended as exit)
45.8m (from any point In a room)
15.25m (from any point in a sleeping room)

Page 2
~ -
'-

l
30 m (from any room door intended as exit)
46 m (from any point in a room) )
15 m (from any point in a sleeein~ room_
etentlon & Correctional: s exit)
0 m (from any room door intended a
[ 6 m (from any point in a room)
0 m (from any point in a sleeping room) -
'Hotels & Dormitories:
30 m (from any room door intended as exit)
23 m (within a room to a corridor door)
38 m (within a room to a corridor door, if
with sprinkler syst em)
partment Buildings:
5.5 m (within a unit to nearest exit)
1 m (from entrance door of apartment unit )
6.5 m (from entrance door of apartment
~ unit with s_prmkler system)
Mercantile:
30 meters (w/o sprinkler system)
!46 meters (w/ sprinkler s_ystem)
Industrial:
31 meters (w/o sprinkler system)
I46 meters (w/ sprinkler system)
Storage:
23 meters (w/o sprinkler system)
I30 meters (w/ S_!)_rinkler system)
!Parking Structures:
!23 meters (w/o sprinkler syst em)
] Ometers (w/ sprinkler system )
Doors -.~:· ,:;"'.
'Minimum Width 700mm 710mm 800mm 1700 mm for service door ~oom"l
lsoo mm for main door
Maximum Width 1.2 meters 1.22 meters
Minimum Height 2 meters 2 meters N/A 2 meters (1.& meters for ,2 meters
lmezzaninelt,athrooms)_
!Threshold (max. height) snm m 13 mm - half tnch 25mm
Corridors .-- ~~'

Minimum Width 1.1 meters !Assembly Places 1.12 meters 1.2 meters shall conform with NBC shall conform with NBC
I Educational 1.83 meters and Fire Code and Fire Code
Hospitals & 2.44 meters
nursing homes
Residential-custodial 1.83 meters
care institutions
Hotels & Dormitories 1.12 meters
~ eartm ent< so persons 0 .91 meters
Apartment > S_()__l)ersons
1
1.12 meters
Business & Industrial

shall not reduce width by more


than 200mm beyond crossing width
Projection of Doors shall not reduce corridor width shall maintainll.2 meter
Page 3

---~-~- - -
Ill""
width of corridor
by more t hao 1/2
I 3.5 m eters

~
6 meters 6 meters
Dead End (Max. Distance) .•
., ' _. ": . .; .• •.
Stairways & Ramps N/A .. .. ,.
0. 75 m for occupant load less than 10 1.12 m et ers for occupant load< 2,000 0.6meter
Minimum Width of Stairways 1 1.:1-meter

Riser
0.9 m for occupant load of 50 or less
1.1 m for occupant load more than SO
200 mm (max)
1.42 meters for occupant load >= 2,000

J.80mm (max)
preferably w / slanted
nosing; has color or gray
250mm (max)
{OOmm(max)
\
J.OOmm (min)
value w/ high contrast
250mm (min ) should be o f slip-resistant 200mm (min)
Tread 280mm (min) !250~ m(min)
material; with 0.3 meter
wide tactile strip at top &
bottom of stairs

Winding Stairways min. 250 mm run at a point 300 n1m min. 250 mm run at a point 300 mm min. 250 mm run at a
from the narrowest edge and shall from the narrowest edge and shall point from the
not be less than 150 mm at any point not be less than 150 mm at any point narrowest and shall not
Circular/curved stairways min. width of run shall be 250 mm 280 mm at a point 305 mm from the be less than 150 mm
with 5 mm tolerance narrowest end of tread, smallest radius at any point
shall not be less than twice the stair width
Ladders cannot be used as fire escape and only max. distance between
allowed for 3 stories or less (9 meters ht) landings shall be
rails shall not be less than 1.25 cm x 5 cm 1.8 meters
max. spacing bet. Rails = 400 mm
height of lowest rung from floor = 305 mm
Max. vertical distance bet. landings 3.6 meters 3.66 meters N/A 3.6 meters 3.6 meters
Handrails
Height above tread/ramp 800 mm - 900 mm 760 mm - 865 mm; one at 700mm & 800 mm - 1200 mm
one at 900 mm
Dimension 30 - SO mm wide
Min. clearance N/A 38 mm from wall SO mm from wall/
40 mm from ledge
Min. load N/A 91 kg
Intermediate handrails required for stairways with required for stairways with
more than 3 meters of width more than 2.23 meters of width
Stairway to Roof required in buildings with 4 or
more storeys unless roof has a slope
greater than 1:3

- Ramps
Minimum Headroom 2 meters
. - 2 meters

. ,,.)•·: · ,. :--......,._·:;
\
~--- ..._
'·-:,.:· ~.: .·~-~:;·: ,;. --/.\. t>:·~- ·, -~~
Min. Width 1.1 meters 1.12 meters
1.2 meters
Max. slope 1:12
1:12
Max. rise for a single run 0.76 meter
Max. length
Max. cross slope 6 meters
1:48

-- - - -
may be considered as required exit may substituted for other exits to an extent
if conforming to the provisions of that the total exit capacity will not be
the Code reduced to below half that required
(below 1/3 for health care occupancies)
Openings through Walls
openings in a separating wall openings In a separating wall
Page 4
llll!!llii~t~··(~
shall have 1 -hr fire resistive rating
shall have 2 -hr fire resistive rating
Capacity capacity shall be 0.3 sqm per
capacity shall be0.3 sqm per person
ambulatory occupant and 1.9 sqm
per non-ambulatory occu pant
Bridges & Balconies N/A w idth shallbe the same as the door leading
to it and shall not be less than 1.12 meters
ramps shall be employed for level difference
or steps not greater than 53.34 cm may also
be used
wall openings Within 3 meters of any brid ge
or balcony shall be protected w/ fire doors
or fixed wire-glass w indows
-··. Exit Enclos~re : ·
Places required every interior stairway, ramp, or
escalator shall be enclosed EXCEPT
those serving only one adjacent floor
& those in Group A occupancies
Design Requirements shall not be less than 2-hour fire-
resistive & shall have no openings
except doors and openings in
exterior w alls
stairways & ramps shall have
landings & shall have corridor at
ground floor leading to exterior
Stairways shall not continue below
grade
no enclosed usable space under
stairways
Smokeproof Enciosures
Design Requirements at least one smokeproof enclosure shall be permitted by using natural
for buildings w/ 5-storeys or more ven tilation, by using mechanical
shall be of incombustible ventilation incorporating a vestibule, or
construction by pressurizing_ the stair enclosure
shall have no openings except ~ e 2-hour fire resistance rating
exit doorways and openings in if vestibule is provided:
exterior walls door to vestibule = 11/2 hr fire resistance
opening from the buildings shall door from vestibule to smokeproof
be protected with a self-closing enclosure = 20 min fire resistance
fire assembly having 1-hour fire shall discharge into a public way
resistive rating door-closing device on any door shall
shall exit into a public way activate all devices on other doors
stairway shall not continue below Emergency Power Supply System required
for new mechanical ventilation equipment

shall be adequate to accommodate the


aggregate capacity of all exits discharging
throu_g_h it
Slope exit court = 1: 10 N/A
exit passageway= 1:8
Openings all openings into an exit court less fixed wired glass in steel sash may be
than 3 meters shall be protected by installed in such a separation in building
Page 5
1
fire assemblies having not less than provided w/ automatic fire suppression
3/4 hour fire rating system
Exit Sill.ns & Illuminations 10.7 lux
10.7 lux
Aisles
Aisle Width 0.8 meter if serving only o ne side 0. 76 meter for less than 60 seats
1 meter if serving both sides 0.912 m for greater than 60 sides (1 side)
1.1 mete rs for side aisles 1.22 m for greater than 60 seats (2 sides)
(width increased by 30 mn, w/ every (width increased by 25 mm w/ every
me ter in length towards the exit) meter in length towards the exit)
Max. distance to exit 45 meters
46 meters
Max. no. of seats bet wall & aisle 7
7
Max. no. of seats bet aisles 14 14
Cross Aisles sum of widest aisle + 50% of sum of widest aisle + 50% of
remaning aisles it serves remaining aisles it serves
Aisle Dead Ends (maximum distance) 6 meters 6 meters
Aisle Slope 1:8 12.5%
Seats
Spacing of seats 840 mm (back to back) 830 mm(back to back) 450mm/600mm
(from edge to center)
Min. clear width 450 mm for 18 or less seats
500 mm for 19-35 seats
525 mm for 36-45 seats
550 mm for 46 or more seats
Min. width of seat/seating space 450mm 600 mm (seat w/o dividing arms) 600 mm clear space
for wheelchair
Reviewing Stands, Grandstands, Bleachers
Height of Stands 2.7 meters or 11 rows for stands shall comply with the requirements of
, made of combusible framing NFPA Pamphlet No. 102, "Standards for
[Min. live load 500 kg per sq uare meter Tents, Grandstands, and Air-Supported
IParallel sway force 35 kg per linear meter Structures used for Public Assembly"
Perpendicul~ sway force 15 kg per linear mete r
Row spacing I 600 mm without backrests
750 mm with backrests
850 mm for chair seating
Min. space between the back of seats 300mm
Max. Rise between rows 400mm
Width of seat 450 mm - 480 mm
Max. no. of seats between aisles 15 for open air stands w/ or w/out
backrests and within buildings
w/out backrests;
6 for seat s w/ backrests in buildin~s

~eviewing Stand$, Grandstands, Bleachers


Aisles required shall be provided in all stands
EXCE PT when ALL ff. conditions exist :
-seats are without backrests
-row riser does not exceed 300mm
-no. of rows does not exceed 11
-top seating board is not over
3 me ters above grade
-first seating board is not more
than 500 mm above grade
Page 6
Stairs required when an aisle is elevated more
than 200 mmabove grade
Dead End maximum of 16 rows
Min. aisle width 1.1 meters
Stairs maximum rise 200mm
Stairs minimum run 280mm
Ramp Slope 1:8
Handrails req uired ramps exceeding 1:10 slope
Guardrails required where top of seat plank is more
more than 1.2 meters above grade &
at front of stands elevated more
than 600 mm above _grade
Railing height 1.1 meters
(0.9 meter for guardrails in front of
the grandstand)
Footboards above the 3rd row or where the
seating plank is more than 600 mm
above grade
Securing of Chairs chairs shall be secured EXCEPT
when less than 25 chairs are used
upon a sinile raised platform
when more than 500 loose chairs
are used, chairs shall be fastened
together in groups of not less than 3
Skylights
Elevation above roof 100mm if glass is set at an angle
less than 45• above horizontal
Spacing bet. Supports 625 mm for flat wired glass
1.5 meters for corrugated wired glass
Bays; porches, and Balconies
Railings~quired 750 mm above grade
Penthouses
Height shall not exceed 3.6 meters in
height w ith the roof
shall not exceed 8.4 meters above
roof when used as an enclosure
for tanks & elevators
Area shall not exceed 1/3 of the area
of the supporting roof

Design Requirements towers not enclosed & which extend may have single stairway/ramp exit if:
more than 20 meters above grade -tower is not subject to occupancy by more
shall have iron, steel, or reinforced than 25 persons at any floor level
concrete framework -tower is not used for living/sleeping
shall not occupy more than 1/4 -construction is fire-resistant
of the street frontage Stairs may have no enclosure if the above
base shall not exceed 150 sqm 3 requirements are met, when there is no
if area exceeds 10 sqm, supporting occupancy below top floor level, and when
frames shall extend directly to the the structure is entirely open
ground Stairs shall be class B construction
skeleton towers shall be Imay be of any type of construction if
Page 7
constructed ent irely of
occupancy is not more than 3 persons
incombustible materials when - - · provi·ded
utility/transmitter bldgs. shall be
more than 7.5 meters in height
w/ automatic fire pro tection system
advertisement structures shall be made
of fire-resistant materials
,!\.irtomatic Fire Extinguising System
Places required every storey with an area of On Assembly Occupancie;;;---
200 s qm or more bars w/ live entertainment, dance halls,
dressing rooms, re hearsal rooms, bldgs w/ occupant load of more than 300;
works hops or factories, & other EXCEPT multipurpose rooms with
rooms w/ a n occupant load of more area less than 1,115 sqm not used for
than 10; Group H & I occu pancies exhibition, assembly occupancies
w/ occupant load of more than 500; w/ all sides open, & places of worship at
and if the next doors of said rooms the level of exit discharge w/ sufficie nt
are more than 30 meters from the means of egress
ne arest safe fire dispersa l area r.::--=-:----::~--:--:,------
On Educational Occupancies: -
rooms used for storage or handling every portion below the floor o f exit
of photographic x-ray nitroc ellulose discharge; hazardous areas shall be
films & othe r inflammable articles separated from other parts of the bldg
by 1 hr fire resistive construction or
provided with AFSS
On Health Care Facilities:
througho ut all hospitals
On Hotels, Dormitories, Apartment Bldgs.:
all buildings EXCEPT rooms that have
door opening directly outside street or
grade level or exterior exit access in
bldgs up _to & includingl_goreys in he ight
On Mercantile Occupancies:
all occupancies 3 or more storeys in height,
all occupancies exceeding 1,115 sqm,
throughout the floor below street level
exceeding 232 sq m
On Business Occupanies:
hi.!:_h hazard content areas within the bldg
On Industrial & Storage Occupancies:
every high hazard occupancy
us :: ;

AutQmatic Fire Extlnguisirig System (cont.}


Places Required (cont.) On High-rise Buildings:
throughout all floor spaces including
every closet & concealed spaces
·,pry Standpipes ·-ti i
Places Req uired buildings with 4 or more storeys shall be used for Class I System
Construction fittings/con nections shall withstand fittings/connections shall withstand
20 kg/sq cm of water pre ssure 21 kg/sq cm of water pressure
Size -102 mm dia where highest outlet is 23 m
shall be capable of delivering
900 liters of water per minute or less above fire service connection
-153 mm diameter where highest outlet is
23 m or more above fire service connection
Number required
at least 1 dry standpipe where the all buildings with required enclosed at
area of floor above 3rd floor is stairway or smokeproof enclosure shall
Page 8
- ...:--.-- ---
I
950 sqm or less; additional stand-
have at least 1 dry standpipe outlet
pipe for each additional 950 sqm
Location
w it hin enclosed stairway landings
and within 300 mm of an opening no point in a building shall be more than
\
40
in a stairway enclosure of a balcon y/ meters from a dry standpipe ou tlet
vestibule of a smokeproof tower or (shall be Protected with fire-resistance if
an outside exit stairway not located within an enclosed stairway)
Siamese/Fire Department 2-way for 100 mm dry standpip e 4
Connections -way for wi mm dry standpipe
3-way for 125 mm dry standpipe
(shall be located not less than
4-way for 150 mm dry standpipe
0.46 meter nor less than 1.22 meters
(shall be located not less than
above grade)
0.3 meter nor less than 1.2 meters
above grade)
Outlets 63 mm outlet shall be installed not
64 mm outlet installed 0.61 to 1.22 meters
more than 1.2 meters above floor;
above floor level of each storey
two-way 63 mm outlet sh all be
installed above t he roof
Signs "CONNECTION TO DRY STANDPIPE"
" DRY STANDIPE" 25 mm high raised-letter
25 mm high iron or bronze sign sign, required pressure shall be indicated
Wet Standpipes ·v·:- .. .
, ··,(

Places Required Group H & I of any height -assembly places w/ occupant load
Group C of 2 or more storeys exceeding 1,000
Groups B, D, E, F & G of 3 or more -educational, healthcare, detention,
storeys business, mercantile, industrial, hotels, &
EXCEPT Group H having no stage and apartments 4 or more storeys in height
having a seating capacity of -hazardous storage, business, & mercantile
less than 500 occupancies exceeding 1,869 sqm per floor
EXCEPT buildings with automatic fire
protection system
Construction same w ith dry standpipes same with water distribution sys tem
Size shall be capable of delivering shall not be less than 64 mm in diameter
190 liters of wat er per minute

Number required & Location shall be so determined that all - - shal~so determined that all
portions of building are w ithin portions of building are within
6 meters of a nozzle attached to a 6 met ers of a nozzle attached to a
hose 23 meters in length hose 22 meters in leng_th
Group H & I Occupancies: In assembly occupancies where occupant
1 on each side o f stage load is more than 1000:
1 at the rear o f th e aud itorium 1 on each side of stage
1 at the rear of the balcony 1 on each side of the rear of the auditorium
Groups B, D, E, F & G Occupancies: 1 on each side of the balcony
same with the requirement for
dry standpipes provided that at
least 1 standpipe is installed to
cover not more than 650 sqm
Outlets 38 mm valve in each storey located 38 mm valve in each storey located
1
not less than 300 mm nor more
Page 9
Water Supply 'than 1.2 meters above the floor
wet standpipes shall be connected
to a street main not less than lshalldeliver not less than 132 liters of
100 mm in diameter water per minute at not less than 1 ·8 kilos
Pressu re & Gravity Tanks
per s11 cm residual pressure from 2 outle ts
Capacity
at least 1,500 liters per min. 10 mins.
Pressure at least 265 lit;;; per min. for 30 rnins.
2 kg per square centimter
Clearance from top/bottom struc. 900mm 10 kg per square centimeter
Fire Pump (Capacity) 910mm
at least 1,000 liters per minute
Hose & Hose Re els min. of 38 mm in diameter ~ i v e r notiess than required flo w
max. of 23 meters in len_g_th min. of 38 mm indiameter
Signs N/A
"STANDPIPE AND AUT05PKR" or
Combination Standpipes "AUTOSPKR AND STANDPIPE"
Location N/A
shallbe located as required in dry & wet
standpip_e outlets
Construction N/A
:shall be installed and tested as required
in dry & wet standpipes
Size N/A min. 150 mrndiameter"
Fire Service Connection N/A 46 cm to 122 cm above _g_rade
Outlets N/A 64 mm outlet, located 61 cm to 122 cm
above floor level at each storey
Signs N/A "COMBINATION STANDPIPE AND TEST
CONNECTION" 25 mm high raised letters
Basement Pipe Inlets
Places Required 1st floor of every store, warehouse, 1st floor of every store, warehouse,
or factory with cellars or basements or factory with cellars or basements
Material cast iron, steel, brass, or bronze cast iron, steel, brass, or bronze
with lids of cast brass or bronze & with lids of cast brass or bronze &
shall consist of sleeve not less than shall consist of sleeve not less than
200 mm in diameter 200 mm in diameter
Signs "FOR FIRE DEPARTMENT ONLY, DO "FIRE SERVICE ONLY, DO NOT COVER."

Stage Ventilators there shall be 1 or more ventilators


constructed of metal or
incombustible material near center
and above the highest of any
workin_g__s_tage raised above the roof
Gridirons & Fly galleries shall be designed to support of not stage equipped w/ gridirons, fly galleries,
I

less than 367 kg per sqm & rigging, and every enclosed platform
larger than 46.S sqm shall be protected
w/ automatic fire suppression system
Rooms Accessory to Stage shall have at least 1 hour fire -shall not be more than 15.25 meters from
(dressing rooms, workshops, etc.) resistive occupancy separation exit door
-at least 2 exits from every auxiliary space
-fire protection shall be provided
-no workshop involving the use of
combustible/flammable materials shall
open directly upon a stage
Proscenium Wall shall be separated from auditorium proscenium opening shall be provided
Page 10
of not less than 2-hour _ rith fire resistant & automatic closing
incombustible construction curtain
sha ll extend not less than
proscenium shaii not have more than
1.2 meters above the roof 2 openings entering the stage, each wi th
may have 1 opening at the orchestra an area not exceeding 2 sqm
pit in addition to the main open ings
and not more than 2 openings at the
stage floor area (max. of 2 sqm)
Stage Floor
shall be designed to support of not
less than 620 kg per sqm stage floor opening shall be provided
l
w/ automatic sire suppression system &
baffles at least 30 cm in de_eth
stage shallbe provided w/ fire control
Platforms station w/ indicator li_flht & alarm s'(_stems
enclosed platforms with more than
enclosed platforms with more than
45 sqm of floor area shall be
46.5 sqm of floor area shall be
be provided with ventilator
Stage Exits be provided with ventilator
at least 1 exit not less than 900 mm
wide sha ll be provided from each
side of the stage
an exit stair not less than 750 mm
wide shall be provided for each
fly gallery
at least 2 means of egress each not
less t han 750 mm wide shall be
provided for each tier of dressing
rooms
Motion Picture Projection Rooms
Construction shall not be less than 1-hour shall be of permanent-construction same
fire resistive with the buildin_g in which it is located
Min. Floor Area 7 sqm (additional 3.5 sqm 7.4 sqm (additional 3.75 sqm
aOOltlOno
XII. GENERAL DESIGN & CONSTRUCTION PD 1096 RA 9514 BP 344 BP 220 I PD 957
REQUIREMENTS
Motion Picture Projection Rooms (cont.) i
National Building Code Fire Code of the Philippines Accessibility Law I Economic/Socialized Housing Subdivision/Condominium

Min. Clearance 2.4 meters ceiling height j2.25 square m!!__ters clear working space
Exit shall have at least 2 doorways 'shall have at least 1 out-swinging,
each at least 0. 75 meter wide by self-closing door not less than 0. 76
2 meters high meter wide by 2 meters high
Ports Requirement 1 projection port with an area of aggregateof ports & openings for projection
750 square centimeters equipment shall not exceed 25% of wall
(may be increased to 4,500 sq cm area between the projection room & the
when acetate safe ty film is used ) auditorium
1 observation port with an area of
1,300 s_11_uare centimeters
3 combination ports with an area of
750 mm x 600 mm
Shutters every port shall be provided with N/A
shutter of not less than 2.4 mm thick
with at least 25 mm overlap on all
sides of openinJ:
Ventilation ( Inlet) shall not be less than 900 sq. cm. shall be provided w/ 2 or more air inlet
and shall be installed within SO mm ducts w/ screen openings terminating
of the floor in every projection room within 30 cm of the floor and shall be
Page 11
---
---- -
--
---·---- - ....

arranged in a way that the room will


receive one charge of air every 3 minutes
\
\
ventilation (Outlet) exhaust capacity shall not be less exhaust capacity shall provide a minimum

\
than 0.5 cu.m. nor more than 1.4 of one charge of air every 3 minutes
cu.m. per minute
exhaust ducts shall be kept 25 mm exhaust ducts shall terminate at the
I
from combustible materials or exterior of the building
covered with 10 mm thick heat-
insulating material

Pagel2 ~ - J
;J ;,G;:'-:t·-·-