Lr No: EEECS/Hyd/CIVIL/MTL/QUA/TEM/C-51/2019
Date:23-06-2020
Client: Ramky Enviro Engineers Limited
Name of the Work: Raw Material Testing - Hyderabad Construction & Demolition Waste Management
Facility.
Remarks: The Tested Fine Aggregate Sample confirms to Grading Zone III as per IS 383:2016. It is
recommended to wash the Sand sample before use to reduce the silt content.
Chief Consultant
EE Engineering Construction Services.
EE Engineering Construction Services
An ISO 9001:2000 Certified Company
Lr No: EEECS/Hyd/CIVIL/MTL/QUA/TEM/C-42/2019
Date:23-06-2020
Client: Ramky Enviro Engineers
Name of the Work: Raw Material Testing - Hyderabad Construction & Demolition Waste Management
Facility.
S.No Property of the Material Recycled Fine Sand Natural River Sand
Remarks:
1.The fine aggregate (Recycled Sand) is suitable for Plastering as per IS Codal provisions.
2. However, Fine Sand can be used for concreting if it is mixed with the Coarse Sand.
3. Silt Content for the Recycled Sand should be less than 8.0 %, this can be attained by washing the
sand . Further, this can be also controlled if this sand is used by mixing with the coarse sand.
Chief Consultant
EE Engineering Construction Services.
.
EE Engineering Construction Services
An ISO 9001:2000 Certified Company
Chief Consultant,
EE Engineering Construction Services.