Sl.
Test Conducted Results IS: 8112-1989 Stipulation Remarks
No.
1 Normal Consistancy 33% Not Specified -
3 Final Setting Time 289 Not More than 600 Minutes Pass
Compressive Strength:
a)72 ± 1h (3 days) 28.78 Mpa Shall not be less than 23.00 Mpa Pass
4
b)168 ± 1h(7 days) 37.24 Mpa Shall not be less than 33.00 Mpa Pass
c) 672 ± 4h(28 days) 45.22 Mpa Shall not be less than 43.00 Mpa Pass
Fineness (By Blaine’s air
5
permeability method)
269.00m2 / kg Shall not be less than 2252/ kg Pass
Soundness ( Le-CChatelier’s
6
method)
1.83 Not more than 10 mm Pass
Reference : Nill
Samples supplied by : M/s S.R. Construction
Date of testing : 13.10.2015
Material : Sand Total Wt. of Sand in gms 1900
Cumulative Cumulative
Weight Retained Spec. Limits
Is Sieve Size in mm Retained Weight Passing in
Retained (gm) weight in % For Zone- II
weight in% %
1 2 3 4 5 6
10 0 0 0 100 100
4.75 57 3.00 3.00 97.00 90-100
2.26 342 18.00 21.00 79.00 75-100
1.18 418 22.00 43.00 57.00 55-90
600 Micron 399 21.00 64.00 36.00 35-59
300 285 15.00 79.00 21.00 8-30
150 323 17.00 96.00 4.00 0-10
75 38 2.00 98.00 2.00 0-10
Sieve Analysis Zone II
Fineness Modulus 2.96
Silt Content 1.60
Specific Gravity 2.62
Note
1.The report shall not be reproduced, except in full, without the written approval of the laboratory.
2.The results indicated above are based on the tests carried out on the samples received in the laboratory.
3. Any Query regarding the report must be reported immediately.
Reference : Nill
Samples supplied by : M/s S.R. Construction
Date of testing : 13.10.2015
Material : 12.5mm Aggregates
Total Wt. of Aggregates in gms 5600
Cumulative Cumulative
Weight Retained Spec. Limits
Is Sieve Size in mm Retained Weight Passing in
Retained (gm) weight in % For Zone- II
weight in% %
20 0 0 0 100 100
Reference : Nill
Samples supplied by : M/s S.R. Construction
Date of testing : 13.10.2015
Material : 20mm Aggregates
Total Wt. of Aggregates in gms= 4950
Cumulative Cumulative
Weight Retained Spec. Limits
Is Sieve Size in mm Retained Weight Passing in
Retained (gm) weight in % For Zone- II
weight in% %
40 0 0 0 100 100
Note
1.The report shall not be reproduced, except in full, without the written approval of the laboratory.
2.The results indicated above are based on the tests carried out on the samples received in the laboratory.
3. Any Query regarding the report must be reported immediately.
Reference : Nill
Samples supplied by : M/s S.R. Construction
Date of testing : 13.10.2015
Material : 40mm Aggregates
Total Wt. of Aggregates in gms= 7480
Cumulative Cumulative
Weight Retained Spec. Limits
Is Sieve Size in mm Retained Weight Passing in
Retained (gm) weight in % For Zone- II
weight in% %
80 0 0 0 100 100
Note
1.The report shall not be reproduced, except in full, without the written approval of the laboratory.
2.The results indicated above are based on the tests carried out on the samples received in the laboratory.
3. Any Query regarding the report must be reported immediately.
The results of the tests conducted on the steel sample are as follows:
Chemical Analysis Mechanical Analysis
0.2%
Sl. Nominal Elongatio
Mass (wt) proof Bend Rebend
no size (dia) C S P UTS n
(Kg/mtr) SP stress/Yiel Test test
(mm) % % % N/mm2 percentag
d stress
e
N/mm2
1 8 0.386 0.26 0.051 0.053 0.101 582 628 16.01 O.K O.K
2 10 0.582 0.26 0.053 0.051 0.104 628 622 15.68 O.K O.K
3 12 0.854 0.26 0.054 0.054 0.102 592 646 16.01 O.K O.K
4 16 1.571 0.26 0.052 0.052 0.101 624 568 18.22 O.K O.K
5 20 2.382 0.26 0.051 0.051 0.100 632 672 20.16 O.K O.K
Requirements as per IS: 1786-2008
0.2%
Mass Mass
proof UTS Elongatio
Dia (wt) (wt) Phosp
Dia (mm) Grade stress (N/mm2) n (%) Corbon Sulphur S&P
(mm) (Kg/m) (Kg/m) horous
(N/mm2) (Min) (Min)
(Min) (Min)
(Min)
1.483
8 0.363 16 545 or 8%
more than
2.366 Fe-500 500
Actual Proof
12.0 0.30 0.055 0.055 0.105
10 0.567 20 stress
whichever is
12 0.834 higher
Note
1.The report shall not be reproduced, except in full, without the written approval of the laboratory.
2.The results indicated above are based on the tests carried out on the samples received in the laboratory.
3. Any Query regarding the report must be reported immediately.
The results of the tests conducted on the steel sample are as follows:
Remarks: The tested water sample conforms to requirement of IS 456-2000 for Plain and reinforced
concrete construction.
Note
1.The report shall not be reproduced, except in full, without the written approval of the laboratory.
2.The results indicated above are based on the tests carried out on the samples received in the laboratory.
3. Any Query regarding the report must be reported immediately.