You are on page 1of 11

ROAD IMPROVEMENT AND DEVELOPMENT PROJECT ( RIDP )

Upgrading/Improvement of Ch (km 0+000 - km 131+700


Kaligandaki Corridor, Gaidakot - Pipaldada Road
Contract Identification No. RIDP/337133/GPR-04/2074-075
km-0+000 to km 131+700
Material test at Laboratory No. 2, Bulingtar - 3 Nawalpur
MODIFIED PROCTOR COMPACTION TEST
Lab Ref. :- GRPR/04-Lab-02 SG-93 Location/chainage :- 45+500
Sample Description :- Sub Grade Materials Date of Sampling :- 1-Nov-20
Source of material :- Existing Subgrade Materials Date of test :- 17-Nov-20
Sampled by :- Jointly Tested by :- Jointly

Density Mould Volume(g/cc) : 2260.8


Test number 1 2 3 4 5
Mass of mould+base+compacted specimen gm 11482 11814 11860 11810 11680
Mass of mould gm 6615 6615 6615 6615 6615
Mass of compacted specimen gm 4867 5199 5245 5195 5065
Bulk density gm/cc 2.153 2.300 2.320 2.298 2.240
Dry density gm/cc 2.069 2.161 2.198 2.128 2.013
Moisture Content
Container No 7 8 10 4 25
Wt. of container + Soil gm 155.60 130.90 187.10 152.40 138.50
Wt of dry Soil + cointainer gm 151.60 125.80 179.8 144.90 130.50
Wt. of water gm 4.00 5.10 7.30 7.50 8.00
Wt. of container gm 53.30 46.30 48.40 51.20 59.60
Wt of dry Soil gm 98.30 79.50 131.40 93.70 70.90
Moisture Content % 4.07 6.42 5.56 8.00 11.28

2. 0

2.10

2.0

1.90

1.80
m

1.70
m
m
M
u
a
x
iD
ry
D
n
e
s
t
y
ic
/
g
(c
)

1.60
2 3 4 5 6 7 8 9 10 1 12 13 14
OMC
Optimum Moisture Content :- 5.56 %
Mixmum Dry Density :- 2.198 gm/cc
Comments:

Contractor: Engineer:
Soil Test (P) Ltd, Tech Studio of Engineering (P) Ltd, Aviyaan
M/S EKK Infrastructure Limited Consulting (P) Ltd in association with, Hydro Trans (p) Ltd, Geocom
Nepal Consult (P) Ltd.
Tested by Checked by Submitted by Witnessed by Checked by Verified by Approved by
Lab Technician Q. C. E. CM Sr.Lab Technician Q. C. E ME RE
ROAD IMPROVEMENT AND DEVELOPMENT PROJECT ( RIDP )
Upgrading/Improvement of Ch (km 0+000 - km 131+700
Kaligandaki Corridor, Gaidakot - Pipaldada Road
Contract Identification No. RIDP/337133/GPR-04/2074-075
km-0+000 to km 131+700
Material test at Laboratory No. 2, Bulingtar - 3 Nawalpur
CALIFORNIA BEARING RATIO ( CBR) TEST (AASTHO)
Lab Ref. :- GRPR/04-Lab-02 SG-93 Location/chainage :- 45+500
Sample Description :- Sub Grade Materials Soaking Date :- 10-Feb-20
Source of material :- Existing Subgrade Materials Testing Date :- 14-Feb-20
Sampled by :- Jointly

No. of Layers :- 5 Soaking Period: 96 hours MDD 2.198 g/cc Surcharge Weight :- 5 Kg OMC :- 5.56 %
Compaction Moisture Content
Test Condition → Unsoaked Soaked Test Condition Unsoaked Soaked
Mould No. → B1 B2 B3 B1 B2 B3 Mould No. → B1 B2 B3 B1 B2 B3
No. of blows per layer → 10 30 65 10 30 65 Container No. → 6 8 12 3 10 14
Wt. of wet sample + mould gm 10690 10998 12310 10900 11250 12500 Wt. Container+Wet Soil (A) gm 145.20 150.10 153.20 125.60 129.10 130.20
wt. of mould gm 6530 6650 7620 6530 6650 7620 Wt. Container+Dry Soil (B) gm 136.50 141.20 143.40 117.50 120.70 121.30
Wt. of wet sample gm 4160 4348 4690 4370 4600 4880 Wt. of water ww = (A-B) gm 8.70 8.90 9.80 8.10 8.40 8.90
Volume of mould cc 2183.63 2218.02 2252.41 2183.63 2218.02 2252.41 Wt. of empty container C gm 44.80 46.30 38.70 48.80 48.40 39.70
Wet unit wt. gm/cc 1.905 1.960 2.082 2.001 2.074 2.167 Wt. of dry soil wd = (B-C) gm 91.70 94.90 104.70 68.70 72.30 81.60
Avg. moisture content % 9.49 9.38 9.36 11.79 11.62 10.91 Moisture Content %
9.49 9.38 9.36 11.79 11.62 10.91
Density (Dry Unit wt) gm/cc 1.740 1.792 1.904 1.790 1.858 1.954 Mc = (ww/wd) X 100
CBR Penetration results: Proving Ring Callibration Factor: 7.49 Plunger Area : 19.625 cm2
Penetration Standard Mould No. B1 Mould No. B2 Mould No. B3
Load Test Load Applied Load Test Load Applied Load Test Load Applied Load
mm kg/cm2 Dial gauge kg kg/cm2 Dial gauge kg kg/cm2 Dial gauge kg kg/cm2
0 0.0 0 0 0.0 0 0 0.0 0 0
0.5 - 6.0 44.94 2.29 8.0 59.92 3.05 11.0 82.39 4.20
1.0 - 9.0 67.41 3.43 14.0 104.86 5.34 19.0 142.31 7.25
1.5 - 11.0 82.39 4.20 17.0 127.33 6.49 26.0 194.74 9.92
2.0 - 14.0 104.86 5.34 19.0 142.31 7.25 29.0 217.21 11.07
2.5 70 16.0 119.84 6.11 22.0 164.78 8.40 34.0 254.66 12.98
3.0 19.0 142.31 7.25 26.0 194.74 9.92 38.0 284.62 14.50
4.0 22.0 164.78 8.40 30.0 224.70 11.45 44.0 329.56 16.79
5.0 105 25.0 187.25 9.54 35.0 262.15 13.36 50.0 374.50 19.08
6.0 29.0 217.21 11.07 42.0 314.58 16.03 56.0 419.44 21.37
7.0 34.0 254.66 12.98 48.0 359.52 18.32 63.0 471.87 24.04
8.0 40.0 299.60 15.27 56.0 419.44 21.37 68.0 509.32 25.95

REMARKS

Contractor: Engineer:
Soil Test (P) Ltd, Tech Studio of Engineering (P) Ltd, Aviyaan Consulting (P) Ltd in association with, Hydro
M/S EKK Infrastructure Limited
Trans (p) Ltd, Geocom Nepal Consult (P) Ltd.
Tested by Checked by Submitted by Witnessed by Checked by Verified by Approved by
Lab Technician Q. C. E. C.M Sr.Lab Technician Q. C. E. M.E R.E
ROAD IMPROVEMENT AND DEVELOPMENT PROJECT ( RIDP )
Upgrading/Improvement of Ch (km 0+000 - km 131+700
Kaligandaki Corridor, Gaidakot - Pipaldada Road
Contract Identification No. RIDP/337133/GPR-04/2074-075
km-0+000 to km 131+700

CALIFORNIA BEARING RATIO ( CBR) TEST(AASTHO)


Lab Ref. :- GRPR/04-Lab-02 SG-93 Location/chainage :- 45+500
Sample Description :- Sub Grade Materials Soaking Date :- 10-Feb-2020
Source of material :- Existing Subgrade Materials Testing Date :- 14-Feb-2020
Sampled by :- Jointly

Corrected Pressure, kg/cm2 MDD Mould No. 6 5 4


No. of Blows 10 30 65 2.198 No. of Blows per Layer No. 10 30 65
At 2.5mm Penetration 6.11 8.40 12.98 OMC CBR at 2.5mm Penetration % 8.72 11.99 18.54
At 5.0mm Penetration 9.54 13.36 19.08 5.56 CBR at 5.0mm Penetration % 9.09 12.72 18.17
Dry Density gm/cc 1.790 1.858 1.954
Load kg/cm2

Water Content % 11.79 11.62 10.91


50 Initial Reading mm 0.00 0.00 0.00
10 blows
Final Reading mm 0.87 0.74 0.70
30 blows Swell Total Reading 0.87 0.74 0.70
65 blows Swell % 0.67 0.57 0.54

29
25
27
25
23

CBR, %
21
0 Penetration (mm) 19
0 1 2 3 4 5 6 7 8 9 10
17
Standard load at 2.5mm penetration = 70 kg/cm2
15
Standard load at 5.0mm penetration = 105 kg/cm3
13
MDD at 95% 2.088
CBR Value at 95% Compaction: 25.63 11
Average swell 0.59 9
Results: 7
Laboratory Result Value Specification Remarks
5 Density g/cc
CBR 25.63% Grater than 5% pass 1.700 1.740 1.780 1.820 1.860 1.900 1.940 1.980 2.020 2.060 2.100
Swell 0.59% Less than 1 % pass
REMARKS

Contractor Engineer:
Soil Test (P) Ltd, Tech Studio of Engineering (P) Ltd, Aviyaan Consulting (P) Ltd in association with, Hydro Trans
M/S EKK Infrastructure Limited
(p) Ltd, Geocom Nepal Consult (P) Ltd.

Tested by Checked by Submitted by Witnessed by Checked by Verified by Approved by


Lab Technician Q. C. E. CM Sr.Lab Technician Q. C. E. M.E R.E
ROAD IMPROVEMENT AND DEVELOPMENT PROJECT ( RIDP )
Upgrading/Improvement of Ch (km 0+000 - km 131+700
Kaligandaki Corridor, Gaidakot - Pipaldada Road
Contract Identification No. RIDP/337133/GPR-04/2074-075
km-0+000 to km 131+700
Material test at Laboratory No. 2, Bulingtar - 3 Nawalpur
LIQUID LIMIT & PLASTIC LIMIT
Lab Ref No. :- GRPR/04-Lab-02 SG-93 Location/Chainage :- 45+500
Sample Description :- Sub Grade Materials Date of Samplling :- 1-Nov-20
Source of material :- Existing Subgrade Materials Date of test :- 18-Nov-20

Liquid Limit Plastic Limit


1 Container No. → 1 5 10 8 7 6
2 No. of Blows → 9 21 29 40
3 Wt. of Container + Wet Soil gms 80.10 83.20 79.20 84.10 70.10 72.60
4 Wt. of Container + Dry Soil gms 72.20 76.10 74.10 78.9 67.60 70.20
5 Wt. of Water Present gms 7.90 7.10 5.10 5.20 2.50 2.40
6 Wt. of Empty Container gms 43.00 45.70 48.40 46.30 53.30 44.80
7 Wt. of Dry Soil gms 29.20 30.40 25.70 32.60 14.30 25.40
8 Moisture Content % 27.05 23.36 19.84 15.95 17.48 9.45
Avarage 13.47
Moisture Content, %

35.00

30.00

25.00

20.00

15.00

10.00
1 No. of Blows
10 100
Results :-
Liquid Limit 20.52 %
Plastic Limit 13.47 %
Plasticity Index 7.05 %

Contractor Engineers
Soil Test(P)Ltd ,Tech Studio of Engineering (P)Ltd, Aviyaan Consulting
EKK Infrastructure Limited (P)Ltd, in association With , Hydro Trans (p)Ltd. ,Geocom Nepal
Consult (P)Ltd
Tested by: Checked by : Submitted by: Witnessed by: Checked by : Verified by : Approved by :
Lab Tech. Q.C.E C.M Sr. Lab Tech. Q.C.E M.E R.E
Road Improvement and Development Project (RIDP)
Upgrading /Improvement of Ch (Km 0+000 - Km 131+700)

Kaligandaki Corridor ,Gaidakot - Rampur - Pipaldanda Road

Contract No: RIDP/337133/GRP - 04/2074/ 075


Material Test At Laboratory No.02, Bulingtar -3, Nawalpur
SPECIFIC GRAVITY & WATER ABSORPTION TEST
Lab Ref.No : GRPR/04-Lab-02 SG-93
Sample Description : Sub Grade Materials Sampling Date 30-Aug-19

Material Source : Existing Subgrade Materials Testing Date : 31-Aug-19

Location/Chanage : 45+500

Specimen No. 1 2 3

Weight of Sample + Jar + Water gm 1578 1575 1590

Weight of Sample in Water ( C ) gm 848 845 860

Weight of Jar + Water gm 730 730 730

Weight of Sample Saturated Surface Dry ( B ) gm 1350 1348 1369

Weight of Sample Oven Dry ( A ) gm 1342 1340 1360

Water Absorption = 100 (B - A)/A % 0.596 0.597 0.662

Apparent Specific Gravity = A/(A - C) 2.717 2.707 2.720

Specific Gravity Saturated Surface Dry = B/(B - C) 2.689 2.680 2.690

Bulk Specific Gravity (Oven Dry) 2.673 2.664 2.672

Comments:

Contractor Engineers
Soil Test(P)Ltd ,Tech Studio of Engineering (P)Ltd, Aviyaan Consulting (P)Ltd, in association
EKK Infrastructure Limited
With , Hydro Trans (p)Ltd. ,Geocom Nepal Consult (P)Ltd
Tested by: Checked by : Submitted by: Witnessed by: Checked by : Verified by : Approved by :

Lab Tech. Q.C.E C.M Sr. Lab Tech. Q.C.E M.E R.E
nt and Development Project (RIDP)
ovement of Ch (Km 0+000 - Km 131+700)

idor ,Gaidakot - Rampur - Pipaldanda Road

RIDP/337133/GRP - 04/2074/ 075


Laboratory No.02, Bulingtar -3, Nawalpur
VITY & WATER ABSORPTION TEST

Average

0.618

2.715

2.686

2.670

Engineers
Soil Test(P)Ltd ,Tech Studio of Engineering (P)Ltd, Aviyaan Consulting (P)Ltd, in association
With , Hydro Trans (p)Ltd. ,Geocom Nepal Consult (P)Ltd
Approved by :

R.E
ROAD IMPROVEMENT PROJECT
Package " F "
Upgrading/Improvement Works of Janakpur Parikrama Road
Contract Identification No. RIP/337133/JPR-14/2070-071
Matthigaun to Baidehi section of km-57+000 to 74+660
GRAIN SIZE ANALYSIS OF SOIL DRY & Wet SIEVING
IS :2720 (Part- 4)1985 Second Revision
Lab Ref. No. :- #REF! Location / Cha. :- 45+500
Material Discription :- Sub Grade Materials Sampling Date :- 1-Nov-2020
Source Of Material :- At site ( Borrow pit area ) Testing Date :- 4-Nov-2020
Sampled By :- Jointly Tested By :- Jointly

Oven Dry Sample, gm 500


Weight of sample Weight of (%) Cumulative Wt: Cumulative
IS Sieve (mm)
Retained (gms) Retained Of Retained (%) passing (%)
100.0 0 0 0 100.00
75.0 0 0 0 100.00
19.0 0 0 0 100.00
4.75 0 0 0 100.00
2.00 41.20 8.24 8.24 91.76
0.425 57.30 11.46 19.70 80.30
0.075 142.00 28.40 48.10 51.90
Pan 259.50

100.0
Passing %

90.0
80.0
70.0
60.0
50.0
40.0
30.0
20.0
10.0
0.0
0.0 0.1 1.0 (mm)
Sieve size 10.0 100.0

SUMMARY OF RESULTS
Gravel (-100 mm+4.75mm) percent 0.00 %
Sand (-4.75 mm +75 micron) percent 48.10 %
Clay /silt (-75 micron) percent 51.90 %
Comment :

Contractor Consultant
Shivalaya-Diwa-Roshan (JV) Soil Test - TSE - AVIYAAN - BEAM Consultants J/V
Tested by Representative Witnessed by Checked by Approved by

Lab. Technician Contract Manager Lab.Technician Material Engineer Resident Engineer

You might also like