Devices for EN 50022 rail installation - TECHNICAL CHARACTERISTICS

01850.1 - Relay output actuator 01850.1 - Front view NO NC


C
Technical specifications and connections
• rated voltage: BUS 29 V.
• absorption: 10 mA.
• change-over relay output.
NO C NC
out 1
492.18502 0C 0409 VIMAR - Marostica - Italy

• controllable loads to 120 - 230 V~: 01850.1


out 1 LED

 resistive loads: 16 A (20.000 cycles);


ATTUATORE 1 RELE'

16 A 120-230 V~

 incandescent lamps: 10 A (20.000 cycles);

 fluorescent and energy-saving lamps: Configuration


button
1 A (20.000 cycles);
492.1850A0.1 0A 0806
VIMAR - Marostica - Italy

BUS

 electronic transformers: 4 A (20.000 cycles); 492.18501 0B 0409 VIMAR - Marostica - Italy

 ferromagnetic transformers: 10 A (20.000 cycles);

 motors cos ø 0,6: 3,5 A (100.000 cycles).

• terminals:
BUS line
 bus TP;

 relay contacts (NO, C, NC).

• 2 modules of 17,5 m
• the actuator can be used as a relay for main circulation pump
or solenoid valve in a multi-zone climate control system man-
aged by By-me system.

Conformity to Standards
LV Directive, EMC Directive
EN 50428 Standards

01851.1 - 4-relay outputs actuator


01851.1 - Front view and connections
Technical specifications
• rated voltage: BUS 29 V. Figure 1 Figure 2
N L
~
• absorption: 18 mA. C

• 4 change-over relay outputs.


• controllable loads to 120-230 V~:
M
V1 V3
 resistive loads: 6 A (20.000 cycles); Relay 1 Relay 2 Relay 3
V2
NC C NC C NC C
 incandescent lamps: 6 A (20.000 cycles);
NO NO NO
 fluorescent and energy-saving lamps: NO C NC NO C NC NO C

1 A (20.000 cycles);
 electronic transformers: 4 A (20.000 cycles);
NC NO C NC NO C NC NO C

 ferromagnetic transformers: 6 A (20.000 cycles);


out 1 out 2 out 3 NC NO C NC NO C NC NO C
492.18512 0B 0409 VIMAR - Marostica - Italy out 1 out 2 out 3
492.18512 0B 0409 VIMAR - Marostica - Italy

 motors cos ø 0,6: 3,5 A (100.000 cycles). 01851.1 A 01851.1


ATTUATORE 4 RELE' B
• terminals: 6 A 120-230 V~
out 1
C
ATTUATORE 4 RELE'
out 1
out 2 6 A 120-230 V~

- BUS TP out 3 D
out 2

out 3
- relay contact: 4 (NO, C, NC) out 4 E
out 4
F
• 4 modules of 17,5 mm 492.1851.10 0A 0806 VIMAR - Marostica - Italy
492.1851.10 0A 0806 VIMAR - Marostica - Italy

• the actuator can be used for: out 4


C NO NC
492.18511 0B 0409 VIMAR - Marostica - Italy
BUS
out 4
C NO NC
BUS

- controlling heating/air-conditioning system solenoid valve


492.18511 0B 0409 VIMAR - Marostica - Italy

by means of 20514, 16954, 14514 (figure 1)


- controlling fan coil by means of 20513, 16953, 14513 (figure 2)
NO
C NC
Conformity to Standards Relay 4
BUS line

LV Directive, EMC Directive A: Configuration LED; B: Relay 1 LED; C: Relay 2 LED


EN 50428 Standards D: Relay 3 LED; E: Relay 4 LED; F: Configuration button

­­­494
Devices for EN 50022 rail installation
Actuator with relay output
01850.1 Actuator with 16 A 250 V~ change-over relay output, circulation pump function, on EN 50022 rail installation, occupies
2 17,5 mm modules, RAL 7035 grey

01850.1

Actuator with relay output


01851.1 Actuator with 4 6 A 250 V~ change-over relay outputs, fan-coil regulation function. on EN 50022 rail installation, occupies
4 17,5 mm modules, RAL 7035 grey

01851.1