The “Indication Rating (d)” is the algebraic difference in decibels (dB) between the
Indication Level and the Reference Level with Correction for Attenuation as indicated in
the following expressions:

Instruments with gain in dB:

Indication Rating => d = a - b - c

Where,

d = Indication Rating (dB)

a = Discontinuity Indication Level (dB)

b = Zero Reference Level (dB) Messaging

https://www.linkedin.com/pulse/how-calculate-aws-d11-indication-rating-chandrashekhar-thiramdas/ 1/6
8/24/2020 How to Calculate AWS D1.1 Indication Rating? | LinkedIn

Search
c = Attenuation factor (dB) Try Premium Free
for 1 Month

Zero Reference Level "b"

The transducer shall be placed in


the position shown and the signal
amplitude from the hole (Ø1.5
mm) will be maximized.

Adjust the dB in order to obtain a


signal from 40 to 60% Full-Screen
Height (FSH). This will be used as
the Reference Level “b”.

Discontinuity Indication Level "a"

When a discontinuity indication appears on the screen, the maximum attainable indication
from the discontinuity shall be adjusted to produce a horizontal reference level trace
deflection on the screen.

The adjustment shall be made with the calibrated gain control (attenuator), and the
instrument reading in decibels shall be used as the “Indication Level "a”.

Increase or decrease the dB until the screen


height from the discontinuity is equal to the
reference level. Record the dB under
Indication Level "a"

Attenuation Factor "c"

U. S. Customary Units => The “Attenuation Factor, c” shall be attained by subtracting


1 in. from the sound – path distance and multiplying the remainder by 2.

SI Units => The “Attenuation Factor, c” shall be attained by subtracting 25 mm from the
sound – path distance and multiplying the remainder by 0.08.

Inch to SI System Conversion [2 becomes 0.08 when units changed from U.S. Customary
to SI]

Messaging

https://www.linkedin.com/pulse/how-calculate-aws-d11-indication-rating-chandrashekhar-thiramdas/ 2/6
8/24/2020 How to Calculate AWS D1.1 Indication Rating? | LinkedIn

Search
1 inch = 25 mm Try Premium Free
for 1 Month

=> 1 mm = 1/25 inch = 0.04 inch

Multiplying the remainder by 2

=> 2 * 1 mm = 2 * 0.04 = 0.08

Example (U. S. Customary Units)

If Discontinuity Beam Path = 4 inch

=> Attenuation Factor, c (dB) = [Beam Path - 1 inch] x 2 = [4 inch - 1 inch] x 2 = 3 x 2 = 6


dB

Example (SI Units)

If Discontinuity Beam Path = 100 mm

=> Attenuation Factor, c (dB) = [Beam Path - 25 mm] x 0.08 = [100 - 25] x 0.08 = 75 x
0.08 = 6 dB

It is Always a Whole Number

Attenuation number will be rounded to the nearest whole number.

If the number is less than 0.5 dB it will be lowered to the nearest whole number.

If the number is 0.5 dB or greater, it will be increased to the nearest whole number.

Example - 1 (U. S. Customary Units)

If Discontinuity Beam Path = 1.9 inch

=> Attenuation Factor, c (dB) = [Beam Path - 1 inch] x 2 = [1.9 inch - 1 inch] x 2 = 0.9 x 2 =
1.8 dB

=> Hence the Attenuation Factor, c (dB) ~ 2 dB (Rounded to the nearest whole number ~ 2)

Messaging

https://www.linkedin.com/pulse/how-calculate-aws-d11-indication-rating-chandrashekhar-thiramdas/ 3/6
8/24/2020 How to Calculate AWS D1.1 Indication Rating? | LinkedIn

Try Premium Free


Search for 1 Month

Example - 2 (U. S. Customary Units)

If Discontinuity Beam Path = 4.1 inch

=> Attenuation Factor, c (dB) = [Beam Path - 1 inch] x 2 = [4.1 inch - 1 inch] x 2 = 3.1 x 2 =
6.2 dB

=> Hence the Attenuation Factor, c (dB) ~ 6 dB (Rounded to the nearest whole number ~ 6)

References

1. AWS D1.1/D1.1M: 2015 => Structural Welding Code - Steel

2. Internet Resources

For more information/questions, Please Contact:

✉Email: info@ndttraining-worldwide.com

"Sometimes I win, Sometimes I learn"

Report this

Published by Messaging

https://www.linkedin.com/pulse/how-calculate-aws-d11-indication-rating-chandrashekhar-thiramdas/ 4/6
8/24/2020 How to Calculate AWS D1.1 Indication Rating? | LinkedIn
Chandrashekhar Thiramdas 4 articles Follow
Try Premium Free
Search Welding Inspector and NDT Specialist at Teekay for 1 Month
Published • 11mo

Like Comment Share 37 · 6 Comments

Reactions

+25

6 Comments
Most Relevant

Add a comment…

Gobivenkata Krishnan Narayanan Gopalakris • 2nd 11mo


Technical Specialist at Stork A Flour Company

Good Topic!!
Thanks for sharing!!

· 1 Like · 1 Reply

Chandrashekhar Thiramdas • 2nd 11mo


Welding Inspector and NDT Specialist at Teekay

If anything missing or mistakes found, suggest to update further

· 1 Like

Sandipan Ghorai • 2nd 4mo


--

Thanks

Load more comments

Chandrashekhar Thiramdas
Welding Inspector and NDT Specialist at Teekay

Follow

More from Chandrashekhar Thiramdas

Code, Standard, and Specification - What is SNT-TC-1A? What is EBC ASNT NDT Level III Certification
Differences Program??
Chandrashekhar Thiramdas on Linke…
Chandrashekhar Thiramdas on Linke… Chandrashekhar Thiramdas on Linke…

Messaging

https://www.linkedin.com/pulse/how-calculate-aws-d11-indication-rating-chandrashekhar-thiramdas/ 5/6
8/24/2020 How to Calculate AWS D1.1 Indication Rating? | LinkedIn

Try Premium Free


Search for 1 Month

Messaging

https://www.linkedin.com/pulse/how-calculate-aws-d11-indication-rating-chandrashekhar-thiramdas/ 6/6

You might also like