You are on page 1of 43

WT1151 WT2000 Series Smart Capacitive Pressure Transmitter Contents

Contents

1.1 Product Introduction 2

1.1.1 Denomination of Transmitter Model 2

1.1.2 Product Series 3

1.1.3 WT1151 WT2000 Series Smart Capacitive Pressure Transmitter 5

1 .2 Model Selection Guide 13

1.2.1 WT1151 WT2000DP Differential Pressure Transmitter 14

1.2.2 WT1151 WT2000HP High Static Differential Pressure Transmitter 17

1.2.3 WT1151 WT2000GP Gage Pressure Transmitter 18

1.2.4 WT1151 WT 2000 AP Absolute Pressure Transmitter 21

1.2.5 WT1151 WT2000 LT Flanged Level Transmitter 22

1.2.6 WT1151 WT2000DP/GP Differential/Gage Pressure Transmitter with Remote Seal 26

1.2.7 WT2000TG Smart Directly Mounted Pressure Transmitter 36

1.3 Installation Accessories 38

1.3.1 Installation Bracket and Installation Type 38

1.3.2 Installation Bracket and Installation Type for Directly Mounted 39

1.3.3 Induced Pressure Connector 40

1.3.4 Connection Dimension for Process Flange 41

(The content of this catalog are subject to changes without notice.)

SHANGHAI WELLTECH AUTOMATION CO., LTD 1


WT1151 WT2000 Series Smart Capacitive Pressure Transmitter Product Introduction

1.1 Product Introduction

WT1151 WT2000 series smart capacitive pressure transmitters have been self-developed and produced
by Welltech through introducing overseas sophisticated equipment and benefiting from the advanced
technology & successful experience of overseas similar products. WT1151 WT2000 adopt international
high quality electronic components and key parts, and are supplied to domestic and overseas customers at
most competitive price popularly.
The guidebook only makes a general introduction of the common characteristics for the WT1151
WT2000 series transmitters, including the model denomination, product series, main features, working
principles, function parameters. For the detailed information, please refer to the Operation Manual of
WT1151 WT2000 series capacitive transmitters.

1.1.1 Denomination of Transmitter Model


Table 1 Denomination of Transmitter Model
Necessary items Optional items

WT1151 WT2000

Code Model Structual Material


Code
DP Differential pressure transmitter Flange connector Drain/vent valve Isolating diaphragm Filled liquid

HP High static differential pressure transmitter 22 316 stainless steel 316 stainless steel 316L stainless steel
Silicon oil
AP Absolute pressure transmitter 23 316 stainless steel 316 stainless steel Hastelloy C-276

GP Gage pressure transmitter

LT Flanged level transmitter


Code Accessories & Additional Functions
Differential / gage pressure
DP/GP transmitter with remote seal
M1 0-100% linear indicator (only for WT1151)
TG Directly mounted pressure transmitters
M3 LCD digital indicator

B01 Bending bracket mounted by pipe (carbon steel)

Code WT1151 Measuring Range(kPa) B02 Bending bracket mounted by panel (carbon steel)

2 0 0.125 1.5 B03 Flat bracket mounted by pipe (carbon steel)

3 0 0.75 7.5 B04 Bending bracket mounted by pipe (stainless steel)

4 0 3.74 37.4 B05 Bending bracket mounted by panel (stainless steel)

5 0 18.668 186.8 B06 Flat bracket mounted by pipe (stainless steel)

6 0 68.9 689 D1 Release valve located on upper of pressure chamber side

7 0 206.8 2068 D2 Release valve located on lower of pressure chamber side

8 0 689 6890 D3 Release valve located on opposite of process connecting port

9 0 2068 20680 V0 Vertically mounted pressure chamber (only for WT2000)

0 0 4137 41370 V1 Vertically mounted pressure chamber with side release (only for WT2000)
Code WT2000 Measuring Range(kPa) C1 NPT1/2 female thread oval flange
2 0 0.1 1.5 NPT1/2 induced pressure connector with 14 induced pressure tube welded
C12 behind
3 0 0.188 7.5 C2 M20*1.5 T-shaped male thread connecting block
M20*1.5 T-shaped male thread connecting block with 14 induced pressure
4 0 0.935 37.4 C21 tube welded behind
5 0 4.67 186.8 d Flameproof Exd II BT4
6 0 17.24 690 i Intrinsical safe Exia II CT6
7 0 51.7 2068

8 0 172.25 6890 Code Output

9 0 517 20680 S Smart HART / 4~20 mA DC linear

0 0 1034.2 41370 J Smart HART / 4~20 mA DC square root

2 SHANGHAI WELLTECH AUTOMATION CO., LTD


WT1151 WT2000 Series Smart Capacitive Pressure Transmitter Product Introduction

1.1.2 Product Series(Table 2 3 4)


Table 2

Measuring Range Max. Working


No . Description Model Accuracy Grade
(kPa) Pressure (MPa)

WT1151DP2S 0 0.125 ~ 1.5 4


2 0.25
WT1151DP3S 0 0.75 ~ 7.5 7
3
WT1151DP4S 0 3.74 ~ 37.4
4
WT1151DP5S 0 18.68 ~ 186.8
5
WT1151DP6S 0 68.9 ~ 689 14
6 0.2
WT1151DP7S 0 206.8 ~ 2068
7 Differential WT1151DP8S 0 689 ~ 6890
pressure
transmitter WT2000DP2S 0 0.1 ~ 1.5 4
8
WT2000DP3S 0 0.188 ~ 7.5 7
9
WT2000DP4S 0 0.935 ~ 37.4
10
WT2000DP5S 0 4.67 ~ 186.8
11 0.1
WT2000DP6S 0 17.24 ~ 689 14
12
WT2000DP7S 0 51.7 ~ 2068
13
WT2000DP8S 0 172.25 ~ 6890
14 WT1151HP4S 0 3.74 ~ 37.4
15 WT1151HP5S 0 18.68 ~ 186.8
0.2
16 WT1151HP6S 0 68.9 ~ 689
High static
17 differential WT1151HP7S 0 206.8 ~ 2068
32
18 pressure WT2000HP4S 0 0.935 ~ 37.4
transmitter
19 WT2000HP5S 0 4.67 ~ 186.8
0.1
20 WT2000HP6S 0 17.24 ~ 689
21 WT2000HP7S 0 51.7 ~ 2068
22 WT1151GP3S 0 0.75 ~ 7.5 0.25
23 WT1151GP4S 0 3.74 ~ 37.4
24 WT1151GP5S 0 18.68 ~ 186.8
25 Gage pressure WT1151GP6S 0 68.9 ~ 689 0.2
/
26 transmitter WT1151GP7S 0 206.8 ~ 2068
27 WT1151GP8S 0 689 ~ 6890
28 WT1151GP9S 0 2068 ~ 20680
0.5
29 WT1151GP0S 0 4137 ~ 41370

SHANGHAI WELLTECH AUTOMATION CO., LTD 3


WT1151 WT2000 Series Smart Capacitive Pressure Transmitter Product Introduction

Table 3

Measuring Range Max. Working


No . Description Model Accuracy Grade
(kPa) Pressure (MPa)

30 WT2000GP3S 0 0.188 ~ 7.5


31 WT2000GP4S 0 0.935 ~ 37.4
32 WT2000GP5S 0 4.67 ~ 186.8
33 Gage pressure WT2000GP6S 0 17.24 ~ 689 0.1
/
34 transmitter WT2000GP7S 0 51.7 ~ 2068
35 WT2000GP8S 0 172.25 ~ 6890
36 WT2000GP9S 0 517 ~ 20680
0.2
37 WT2000GP0S 0 1034.2 ~ 41370
38 WT1151AP4S 0 10 ~ 37.4

39 WT1151AP5S 0 18.68 ~ 186.8


40 WT1151AP6S 0 68.9 ~ 689 0.2
41 WT1151AP7S 0 206.8 ~ 2068
42 Absolute WT1151AP8S 0 689~6890
pressure /
transmitter WT2000AP4S 0 10 ~ 37.4
43
WT2000AP5S 0 10 ~ 186.8
44
WT2000AP6S 0 17.24 ~ 689 0.1
45
WT2000AP7S 0 51.7 ~ 2068
46
47 WT2000AP8S 0 172.25 ~ 6890

48 WT1151LT4S 0 3.74 ~ 37.4


49 WT1151LT5S 0 18.68 ~ 186.8 0.2
50
WT1151LT6S 0 68.9 ~ 689 Refer to flange
Flanged level
transmitter WT2000LT4S 0 0.935 ~ 37.4 pressure rating
51
WT2000LT5S 0 4.67 ~ 186.8 0.2
52
53 WT2000LT6S 0 17.24 ~ 689

54 WT1151DP4S 0 6.2 ~ 37.4


Differential
55 WT1151DP5S 0 31.1 ~ 186.8
pressure
Refer to flange
56 transmitter WT1151DP6S 0 117 ~ 689 0.2
pressure rating
with remote
57 WT1151DP7S 0 345 ~ 2068
seal
58 WT1151DP8S 0 1170 ~ 6890

4 SHANGHAI WELLTECH AUTOMATION CO., LTD


WT1151 WT2000 Series Smart Capacitive Pressure Transmitter Product Introduction

Table 4

Measuring Range Mas. Working


No. Description Model Accuracy Grade
(kPa) Pressure (MPa)

59 WT2000DP4S 0 6.2 ~ 37.4


Differential
60 WT2000DP5S 0 31.1 ~ 186.8
pressure
Refer to flange
61 transmitter WT2000DP6S 0 117 ~ 689 0.2
pressure rating
with remote
62 WT2000DP7S 0 345 ~ 2068
seal
63 WT2000DP8S 0 1170 ~ 6890
64 WT1151GP4S 0 6.2 ~ 37.4
65 WT1151GP5S 0 31.1 ~ 186.8
66 WT1151GP6S 0 117 ~ 689
67
WT1151GP7S 0 345 ~ 2068
68
Gage pressure WT1151GP8S 0 1170 ~ 6890 Refer to flange
transmitter with 0.2
WT2000GP4S 0 6.2 ~ 37.4 pressure rating
remote seal
69
WT2000GP5S 0 31.1 ~ 186.8
70
WT2000GP6S 0 117 ~ 689
71
72 WT2000GP7S 0 345 ~ 2068

73 WT2000GP8S 0 1170 ~ 6890


74 WT2000TG4S 0 0.935 ~ 37.4

75 WT2000TG5S 0 4.67 ~ 186.8

76 Directly WT2000TG6S 0 17.24 ~ 689 / 0.1


mounted WT2000TG7S 0 51.7 ~ 2068
77
pressure
78 transmitter WT2000TG8S 0 172.25 ~ 6890

79 WT2000TG9S 0 517 ~ 20680


/ 0.2
80 WT2000TG0S 0 1034.2 ~ 35000

1.1.3 WT1151 WT2000 series smart capacitive pressure transmitter


WT1151 WT2000 series smart capacitive pressure transmitter (hereinafter called smart transmitter ) is
the pressure instrument adopting the microprocessor as its core, which extends the communication and other
functions on the basis of the traditional 1151 capacitive transmitter. With the help of 275, 375 hand held
communicator or other host computer adopting HART protocol, the bi-directional communication (data reading,
writing and diagnosing) could be realized in the control room, transmitter field or any places connecting with
control circuit.
Note: The old version 275 hand held communicator will be valid only after being sent to Welltech to be
amended to the new version one authorized by international HART Foundation.

SHANGHAI WELLTECH AUTOMATION CO., LTD 5


WT1151 WT2000 Series Smart Capacitive Pressure Transmitter Product Introduction

1.1.3.1 Main Features


WT1151 WT2000 series smart capacitive pressure transmitters not only have the inherent features of
ordinary capacitive pressure transmitter, but also have following features:
l Smart electronic part is constituted by one circuit board;
l Turn down ratio: 15:1, recommended: 10:1 (WT1511);
Turn down ratio: 40:1, recommended: 10:1 (WT2000);
l Measuring range: 0-100Pa ~ 41370kPa;
l Being able to adjust span and zero by local buttons;
l Conforming to HART protocol, be able to carry out bi-directional communication with 275, 375 HART
hand held communicator and the output signal will not be interrupted;
l In DCS adopting HART protocol, being able to communicate bi-directionally with the host computer;
l Having self-diagnosis and remote diagnosis functions;
l Be equipped with EEPROM, which ensures no data loss due to the sudden electrical breaking;
l Two-wire, 4-20mA output.
WT2000 series smart capacitive transmitter is furnished additionally with the following features:
l Elaborately designed in accordance with electro magnetic compatibility (EMC) requirement and passed
the CE certification;
l Adopting the digital temperature compensation technology, which greatly improves the temperature
characteristic of the transmitter;
l Modular compact structure, stable and reliable, with no need to open the cover and be able to adjust span
and zero by local buttons.

1.1.3.2 Working Principle


The two pressures of the measured medium act upon the isolating diaphragms on both sides of element (see
Fig. 1 for structure diagram) through high, low pressure chambers, and then transfer to the both sides of the pre-
tensioned measuring diaphragm by the isolating diaphragm and the filled liquid inside the element. Either connection
of the measuring diaphragm with the insulator electrodes of both sides composes a capacitor. In the case of unequal
pressures for both sides, the displacement will take place with the replacement value being proportional to the
differential pressure. Therefore the capacitance of both sides will be unequal, which will convert DC signal
proportional to the pressure through the oscillation and modulation procedures. The work principle of gage pressure
transmitter and absolute pressure transmitter is similar with that of differential pressure transmitter except that the
pressure inside low-pressure chamber is atmosphere or vacuum.
Lead wire Lead wire

Fixed plate of Vaccum reference Fixed plate of


capacitor chamber capacitor

Measuring diaphragm Measuring diaphragm

Solid insulator Solid insulator

Filled silicon oil Filled silicon oil

Isolating diaphragm Welding seal Isolating diaphragm Welding seal

a) Element for Others b) Element for AP

Fig.1 Structure Drawing for Element

1.1.3.3 Working Principle of Smart Pressure Transmitter


A/D convertor transforms the current of the modulator to the digital signal, which will be used by the
microprocessor to judge the input pressure value. The microprocessor controls the work of transmitter. Besides,

6 SHANGHAI WELLTECH AUTOMATION CO., LTD


WT1151 WT2000 Series Smart Capacitive Pressure Transmitter Product Introduction

it is also engaged in such operations as the sensor linearization, resetting measuring range, engineering unit
conversion, damping, square root and sensor trim, as well as diagnosis and digital communication.
4~20mA

Oscillation and modulation


D/A
To control system

A/D signal conversion


Microprocessor signal conversion
sensor linearization
measuring range
Sensitive element transferring function
engineering unit Digital
damp and communication
communication
diagnosis Communication
device
EEPROM
Linear constant
measuring range
constant
transmitter
Zero Span configuration

Fig.2 Frame Diagram of Working Principle for WT1151

4~20mA
Oscillation and modulation

D/A
To control system
A/D signal conversion

Microprocessor signal conversion


sensor linearization
measuring range
Sensitive element transferring function
engineering unit Digital
damp and communication
communication
diagnosis Communication
device
EEPROM
Linear constant
measuring range
constant
transmitter
TC Zero Span configuration

Fig.3 Frame Diagram of Working Principle for WT2000

D/A convertor changes the digital signal, which have been calibrated by the microprocessor, into the 4
~20mA analog signal and then transfers to the output loop. EEPROM stores all the configurations,
characterization and digital trim data, which could be altered by the transmitter software. The data are stored in
the EEPROM, which ensure it stored completely even if in case of outage.
The digital communication circuit offers the transmitter with a connection interface to outside device (such
as 275 smart hand held communicator or the control system adopting HART protocol). The circuit detects the
digital signal overlapping upon 4 ~20mA signal, and transfers the needed information through the loop. The
communication type adopts frequency shift keying technology FSK (Frequency Shift Keying) and conforms to
Bell 202 standard.

1.1.3.4 Function Specification


Service: Liquid, gas and steam.
Measuring range: see the attached table.
Output signal: two-wire 4~20mA DC signal plus digital signal, the square root or linear output may be at the
customer's options.
Power supply: 12 ~45VDC, 15 ~45VDC for with LCD digital display, and 24VDC generally.
Load feature: the maximum load resistance shall be RL = (Vs 12V) / 0.023A, RL -- the maximum load
resistance, and Vs -- the voltage of power supply.

SHANGHAI WELLTECH AUTOMATION CO., LTD 7


WT1151 WT2000 Series Smart Capacitive Pressure Transmitter Product Introduction

Operation area HART Communication area

Fig.4 Load Voltage Relation


Indicator: field output indication is furnished with current meter, 0 ~100% linear indicator, LCD digital indicator
Span and zero: being able to adjust by local buttons or by HART communicator.
Zero elevation and suppression:
l Differential pressure transmitter: the maximum zero elevation is the difference between the upper
range limit (URL hereinafter) and the span, and the maximum zero suppression is equal to URL.
l Gage pressure transmitter: the maximum zero elevation is the difference between URL and the span,
and the maximum zero suppression no more than the atmosphere pressure.
l Absolute pressure transmitter: the maximum zero elevation is the difference between URL and the
span, without zero suppression.
Fault alarm: once the self-diagnosis program examines the faults, the analog output will be higher than 22mA
or lower than 3.8mA to alarm, the high alarm or low alarm may be optional through the switch on the
electronic part.
Transmitter status and protection: switching the switch on the electronic part to prevent the transmitter
configuration from being changed.
Environmental temperature : 25 ~ +75
Storage temperature: 10 ~ +55
Damping: electrical damping is 0.2 ~ 16s, which can be adjusted per 0.1s, inherent time is 0.2s for sensor
(silicon oil filled) , and 0.4s for range code 2.

1.1.3.5 Technical Specification


(Standard reference condition: under conditions of no shifting, silicon oil filled and 316L stainless steel for the
isolating diaphragm)
Accuracy: see table 2,3,4
Stability: being within the accuracy of the transmitter for 12 months
Temperature effect: Please refer to Table 5 for the effect for each 10 under the max. span.
For range code 2, 3 of WT1151, the temperature effect for each 10 is 0.60% .
Static effect: Please refer to Table 6 for the effect under the max. Span.

Table 5

Accuracy Grade
Range Code or Name
0.1 0.2
2 / 0.30%
3 0.20% 0.30%
4 9 0.10% 0.30%
0 / 0.30%
Remote seal, level / /

8 SHANGHAI WELLTECH AUTOMATION CO., LTD


WT1151 WT2000 Series Smart Capacitive Pressure Transmitter Product Introduction

Table 6

Accuracy Grade
Range Code or Name
0.1 0.2
2 / 0.5% / 7MPa
3 0.30% / 14MPa 0.5% / 14MPa
4,5,6,7,8 0.25% / 14MPa 0.30% / 14MPa
High static 4,5,6,7 / 2% / 32MPa
2
Vibration effect: 0.1% of max. span, 10 ~ 60Hz, S = 0.07mm, 60 ~ 150Hz, g = 9.8m/s ; in any direction.
Power supply effect: less than 0.005% of output span/V.
Electromagnetic radiation effect: 0.1% of max. span, radiation frequency 27~500MHz, test magnetic strength
3V/m.
Electro magnetic compatibility (EMC): see Table 7 (for WT2000).
Installation position impact: the working diaphragm not in vertical will result in a zero system error of zero of
no more than 0.24kPa, which could be offset by adjusting zero and bring no impact to span.
Structure material: for the material for such wetted parts as pressure chamber, connector, release valve,
isolating diaphragm etc., please refer to the model and ordering code of different models.
l the bolts is the galvanized carbon steel
l The electrical housing is low copper aluminum alloy, with the epoxy sprayed coating on surface.
Induced pressure connection: the connecting screws of the pressure chamber are NPT1/4, the connecting screws
of the induced pressure connectors are NPT1/2, and the center distance can be altered by adjusting the
connection block (51, 54, 57mm).
Electrical connection: two screws of M20 1.5 or NPT 1/2 female screws are available on the transmitter
housing to connect the cable duct. Inside the housing, there are cable terminals and measuring shims
offered for testing. For connection with communicator, it could only be connected onto the measuring
shims.
Weight: about 5kg for WT1151 (excluding accessories, except flanged pressure transmitter),
about 3.5kg for WT2000 (excluding accessories, except flanged pressure transmitter).

Table 7 EMC for WT2000 Pressure Transmitte

No. Test Item Test Standards Test Method/ Performance Test Result
Condition Class

EN61326:1997+A1:1998 See Clause


1 Emission enclosure 30MHz ~ 1000MHz Pass
Clause7.2 and Table 3 9

Emission EN61326:1997+A1:1998 See Clause


2 0.15MHz ~ 30MHz Pass
(DC mains) Clause7.2 and Table 3 9

4kV(contact)
3 Electrostatic discharge B Pass
8kV(air)

80MHz ~ 1000MHz
4 EM field 10V / m A Pass
80% AM

SHANGHAI WELLTECH AUTOMATION CO., LTD 9


WT1151 WT2000 Series Smart Capacitive Pressure Transmitter Product Introduction

Continued Table 7

No. Test Item Test Standards Test Method/ Performance Test Result
Condition Class
30A/m
Rated power frequency
5 Direction: transverse A Pass
magnetic field
longitudinal and vertical
2kV.5 / 50(Tr / Tn)ns
6 Burst 5kHz(+ / ) B Pass

1kV(differential mode)
7 Surge 2kV(common mode) B Pass
1.2ìs /50ìs
0.15MHz~80MHz
8 Conducted RF 10V A Pass
80% AM

Note: EMC authorized standard CE, EN61326: 1997+Al: 1998


Performance judging criterion A: with normal performance within the limit of technology specifications during
the test.
Performance judging criterion B: with a temporal reduction or loss in terms of the function or performance
during the test, but can be restored itself.
Performance judging criterion C: with a temporal reduction or loss in terms of the function or performance
during the test, but can only be restored through operator's intervention or system resetting.

1.1.3.6 Smart Electronic Part


It adopts advanced integrated circuit and Surface Mount Technology (SMT), the electronic part of the
transmitter is constituted by one circuit board.
The microprocessor of the transmitter controls the conversion work of A/D and D/A, and can also
implement the self-diagnosis and the digital communication.
During the process of working, one digital pressure value is processed by the microprocessor, and stored
as a digital to ensure the precise modification and the conversion of engineering units. In addition, the
microprocessor can also realize such functions as linearization of the sensor, turn down ratio, damping time and
other functions. EEPROM stores all the configurations, characterization and digital trim data. EEPROM is a
nonvolatile memory device, which makes sure all the data could be completely stored in case of electrical
breaking, thus realizing the real-time smart communication.
Software
One set of 275 or 375 hand held communicator could realize the testing and configuration for WT1151
WT2000 smart transmitter, or any upper level system in conformity with HART communication protocol could
implement the communication. HART protocol adopts BELL202 frequency shift keying (FSK) of the industrial
standard. The communication could be realized through the digital signal of 1200Hz or 2200Hz overlapped on
the signal of 4~20mA. During the process of communication, the frequency signal would not exert any
influence on the analog signal of 4~20mA.
Self-diagnosis
WT1151 WT2000 smart transmitter can implement the continuous self-diagnosis. Once any fault with
the transmitter is detected, the client may make free choice for the transmitter output among 22mA or 3.8mA.
Moreover, any HART upper level device can display the special signal code self-diagnosed by the transmitter.
Formatting
The formatting function is used for the initial setting of the transmitter or the maintenance of the digital
electronic part. The standard formatting menu offers two functions: sensor adjusting and analog output
adjusting.

10 SHANGHAI WELLTECH AUTOMATION CO., LTD


WT1151 WT2000 Series Smart Capacitive Pressure Transmitter Product Introduction

Sensor adjusting: including the characterization and sensor trim, this enables the electronic part to precisely
reflect the pressure input. Meanwhile, the standard pressure source must be adopted.
l Characterization: although WT1151 WT2000 smart transmitter has been characterized before leaving the
factory, the client can still use this function, to make some simple update for WT1151 analog pressure
transmitter to convert to smart type.
Characterization function: adjusting the electronic part of WT1151 WT2000 smart transmitter to make
sure it reflects the sensor output correctly.
l Sensor trim: the function allows the characterized digital to be micro-adjusted. It affects originally
characterized results. For the detailed information, please refer to the manual.
Analog adjusting: make the digital current valu e of the transmitter be co nsistent with the 4~20mA analog
current of the transmitter.
Note: Please read the manual before implementing the adjusting.

Configuration
Standard configuration: the goods would be provided according to the following configurations, unless
otherwise specified: engineering unit--kPa; 4mA--0kPa; 20mA--upper range limit (URL) ; output--linear
Software tag: blank [software tag(8 characters), blank unless otherwise specified]
Special configuration: in addition to the standard configuration data, the clients can also designate the
following additional data(Table 8).

Table 8

Description symbol 16 characters Insolating diaphragm material Type code information

Information 32 characters Sensor filled liquid Type code information

Date Day/month/year Drain/vent Type code information

Damp Second Compact indicator Installed or not installed

Remote seal device Particular information

Flange material Type code information Fault alarm mode High or low

O ring material Type code information Parameter writing protection Off /on

1.1.3.7 Field Wiring Diagram


RL

Power supply

Ammeter
HART
Communicator

Smart transmitter Indicator gauge

Fig.5 Field Wiring Diagram for WT1151 WT2000 Smart Capacitive Transmitter

SHANGHAI WELLTECH AUTOMATION CO., LTD 11


WT1151 WT2000 Series Smart Capacitive Pressure Transmitter Product Introduction

1.1.3.8 Bus Communication


WT1151 WT2000 series smart capacitive transmitter can adopt multi-station mode, that is, 15 sets of
smart capacitive transmitter can be connected through one bus line (telephone line or twisted pair line) to
realize the bi-directional communication with the host computer(adopting HART protocol). See Fig.6 for the
working principle.

HART
serial interface

24V power supply

Hart smart capacitive pressure


transmitter

Addr1 Addr2 Addr3

Fig.6 Multi-station Communication Sketch Drawing for WT1151 WT2000 Smart Capacitive Transmitter

12 SHANGHAI WELLTECH AUTOMATION CO., LTD


WT1151 WT2000 Series Smart Capacitive Pressure Transmitter Product Introduction

1 .2 Model Selection Guides


This section lists the outline diagram, outline dimensions, installation types , model and ordering code of
different types WT1151 WT2000 capacitive transmitter.
There are two kinds of material, buna and viton for the wetted O ring. Unless otherwise specified in the
ordering, buna is usually adopted. Viton is used for high static differential pressure transmitter and pressure
transmitter of range code 9 and 0. Buna is used for wetted O ring of oval flange.
If the customer needs to order the transmitter of special model, special specification or special structure
and material, which is not listed in this catalog, please contact with our sales department, and we will do our
best to meet the needs of the customers.
As to measuring dangerous gas; or working pressure is over 10MPa; or temperature of medium is >200 ,
< 25 ; or very corrosive medium such as vitriol, hydrochloric acid etc., please make sure to designate name
of medium, pressure, temperature, consistency, density etc. The buyer shall be responsible for the model
selection, anti-corrosion, installation and operation.

Warranty
With respect to the failed transmitter due to the inherent quality problem, our company promises
to repair or replace the product free of charge within 18 months after the delivery of the goods on the
premise that the failed transmitter should be sent back to our company. In the case of repairing
and replacing the products out of the warranty period, our company will charge the due cost.

SHANGHAI WELLTECH AUTOMATION CO., LTD 13


WT1151 WT2000DP Differential Pressure Transmitter Model Selection Guides

1.2.1 WT1151 WT2000DP Differential Pressure Transmitter


Adopting the differential capacitor as the detecting element to constitute the capacitive transmitter, with
the input pressure being 0~1.5kPa, 0~7.5kPa, 0~37.4kPa and 0~1865kPa etc.
Service: liquid, gas and steam.
Output: 4~20mA DC, in conformity with HART communication protocol.

Fig.7 WT1151DP/HP Differential Pressure Transmitter Outline

177 (with field indicator)

1. Nameplate (remove it when adjusting span and zero);


2. Oval flange, induced pressure connection screw is NPT1/2. Note: Oval flange can be turned;
3. While without oval flange, NPT1/4 screw on the pressure chamber for induced pressure connection;
4. NPT1/4 screw for connecting with the release valve (on upper or on lower);
5. Release valve;
6. Pressure chamber, turnable.

Fig.8 Outline Dimension for WT1151DP/HP Differential Pressure Transmitter

14 SHANGHAI WELLTECH AUTOMATION CO., LTD


WT1151 WT2000DP Differential Pressure Transmitter Model Selection

Fig.9 WT2000DP/HP Differential Pressure Transmitter Outline


133.5 (with field indicator)

92
198

Vertically Mounted
Pressure Chamber
1. Nameplate;
2. NPT1/4 screw for connecting with the release valve (on upper or on lower);
3. Pressure chambe, turnable;
4. Release valve;
5. NPT1/4 screw on the pressure chamber for induced pressure connection.

Fig.10 Outline Dimension for WT2000DP/HP Differential Pressure Transmitter

Table 9

Range Code 2~5 6 7 8

A (mm) 54.0 55.6 55.6 56.8

Note: Dimension A changed while the oval flange is turned, i.e. A 3mm

SHANGHAI WELLTECH AUTOMATION CO., LTD 15


WT1151 WT2000DP Differential Pressure Transmitter Model Selection

Model and Ordering Code for DP Differential Pressure Transmitter


Table 10
WT1151DP Smart Differential Pressure Transmitter
WT2000DP Smart Differential Pressure Transmitte
Code WT1151DP Measuring range(kPa) WT2000DP Measuring range(kPa)
2 0-0.125~1.5(Max.working pressure 4MPa) 0-0.1~1.5(Max.working pressure 4MPa)
3 0-0.75~7.5(Max.working pressure 7MPa) 0-0.188~7.5(Max.working pressure 7MPa)
4 0-3.74~37.4 0-0.935~37.4
5 0-18.68~186.8 0-4.67~186.8
6 0-68.9~689 0-17.24~690
7 0-206.8~2068 0-51.7~2068
8 0-689~6890 0-172.25~6890
Code Output
S Smart 4 ~ 20mA DC in conformity with HART communication protocol
J Smart 4 ~ 20mA DC square root output in conformity with HART communication protocol
Structual material
Code Flange connector Vent/drain valve Isolating diaphragm Filled liquid
22 316 stainless steel 316 stainless steel 316 stainless steel
Silicon oil
23 316 stainless steel 316 stainless steel Hastelloy C-276
Code Max.working pressure MPa
No marking 10(only for measuring range code 4 5 6 7 8)
D- 14 (only for measuring range code 4 5 6 7 8)
Code Indicator
M1 0~100% linear indicator(only for WT1151)
M3 LCD digital indicator
Code Installation bracket
B01 Bending bracket mounted by pipe(carbon steel)
B02 Bending bracket mounted by panel(carbon steel)
B03 Flat bracket mounted by pipe(carbon steel)
B04 Bending bracket mounted by pipe(stainless steel)
B05 Bending bracket mounted by panel(stainless steel)
B06 Flat bracket mounted by pipe(stainless steel)
Code Pressure chamber
D1 Release valve located on upper of pressure chamber side
D2 Release valve located on lower of pressure chamber side
D3 Release valve located on the opposite of the process connecting port
V0 Vertically mounted pressurechamber (only for WT2000)
V1 Vertically mounted pressure chamber with side release(only for WT2000)
Code Connector
C1 NPT1/2 female thread oval flange
NPT1/2 induced pressure connector with 14
C12 induced pressure tube welded behind

C2 M20 1.5 T-shaped male thread connecting block


M20 1.5 T-shaped male thread connecting block
C21
with 14 induced pressure tube welded behind
Code Safe grade
d Flameproof Exd II BT4(WT1151)/CT3~T6(WT2000)
i Intrinsical safe Exia II CT6(WT1151)/CT3~T6(WT2000)
Code Cleaning
1 Degreasing on surface (only for WT2000)

WT1151DP 5 S 22 D- M1 B01 D2 C12 d WT1151DP model selection example


WT2000DP 5 S 22 M3 B01 D2 C12 i 1 WT2000DP model selection example

16 SHANGHAI WELLTECH AUTOMATION CO., LTD


WT1151 WT2000HP High Static Differential PressureTransmitter Model Selection

1.2.2 WT1151 WT2000HP High Static Differential Pressure Transmitter


The high static pressure transmitter can measure the differential pressure under working pressure of
32MPa. Withstanding working pressure of 32MPa and the overload protection ensure the transmitter can be
used reliably in high static pressure system.
Output 4~20mA DC, in conformity with HART communication protocol.

Model and Ordering Code for HP High Static Differential Pressure Transmitter
Table 11
WT1151HP Smart High Static Differential Pressure Transmitter
WT2000HP Smart High Static Differential Pressure Transmitte
Code WT1151HP Measuring range(kPa) WT2000HP Measuring range(kPa)
4 0-3.74 37.4 0-0.935 37.4
5 0-18.68 186.8 0-4.67 186.8
6 0-68.9 689 0-17.24 690
7 0-206.8 2068 0-51.7 2068
Code Output
S Smart 4 20mA DC in conformity with HART communication protocol
J Smart 4 20mA DC square root output in conformity with HART communication protocol
Structual Material
Code
Flange connector Vent/drain valve Isolating diaphragm Filled liquid
22 316 stainless steel 316 stainless steel 316 stainless steel Silicon oil
Code Max.Working pressure MPa
No marking 25
F- 32
Code Indicator
M1 0~100% linear indicator (only for WT1151)
M3 LCD digital indicator
Code Installation bracket
B01 Bending bracket mounted by pipe(carbon steel)
B02 Bending bracket mounted by panel(carbon steel)
B03 Flat bracket mounted by pipe(carbon steel)
B04 Bending bracket mounted by pipe(stainless steel)
B05 Bending bracket mounted by panel(stainless steel)
B06 Flat bracket mounted by pipe(stainless steel)
Code Pressure chamber
D1 Release valve located on upper of pressure chamber side
D2 Release valve located on lower of pressure chamber side
D3 Release valve located on the opposite of the process connecting port
V0 Vertically mounted pressure chamber (only for WT2000)
V1 Vertically mounted pressure chamber with side release(only for WT2000)
Code Connector
C1 NPT1/2 female thread oval flange
NPT1/2 induced pressure connector with 14 induced
C12 pressure tube welded behind
Code Safe Grade
d Flameproof Exd II BT4(WT1151)/CT3~T6(WT2000)
i Intrinsical safe Exia II CT6(WT1151)/CT3~T6(WT2000)
Code Cleaning
1 Degreasing on surface(only for WT2000)

WT1151HP 5 S 22 F M1 B01 D2 C12 d WT1151HP model selection example


WT2000HP 5 S 22 M3 B01 D2 C12 i 1 WT2000HP model selection example

SHANGHAI WELLTECH AUTOMATION CO., LTD 17


WT1151 WT2000GP Gage Pressure Transmitter Model Selection

1.2.3 WT1151 WT2000GP Gage Pressure Transmitter


WT1151 WT2000GP capacitive pressure transmitter (gage pressure) can measure the pressure within a
range from 0.188kPa to 41370kPa.
Service: liquid, gas and steam.
Output: 4~20mA DC, in conformity with HART communication protocol.

Fig.11 WT1151GP/AP Pressure Transmitter Outline


177 (with field indicator)

1. Nameplate (remove it when adjusting span and zero);


2. Oval flange, induced pressure connection screw is NPT1/2. Note: oval flange can be turned;
3. While without oval flange, NPT1/4 screw on the pressure chamber for induced pressure connection;
4. NPT1/4 screw for connecting with the release valve (on upper or on lower);
5. Release valve;
6. Pressure chamber, turnable.

Fig.12 Outline Dimension for WT1151GP/AP Pressure Transmitter

18 SHANGHAI WELLTECH AUTOMATION CO., LTD


WT1151 WT2000GP Gage Pressure Transmitter Model Selection

Fig.13 WT2000GP/AP Pressure Transmitter Outline


133.5 (with field indicator)

92
198

Vertically Mounted
Pressure Chamber
1. Nameplate;
2. NPT1/4 screw for connecting with the release valve (on upper or on lower);
3. Pressure chamber, turnabl;
4. Release valve;
5. NPT1/4 screw on the pressure chamber for induced pressure connection.

Fig.14 Outline Dimension for WT2000GP/AP Pressure Transmitter

Table 12

Range Code 3~5 6~7 8 9 0

A (mm) 54.0 55.6 56.8 57.9 59.1

Note: Dimension A changed while the oval flange is turned, i.e. A 3mm

SHANGHAI WELLTECH AUTOMATION CO., LTD 19


WT1151 WT2000GP Gage Pressure Transmitter Model Selection

Model and Ordering Code for GP Gage Pressure Transmitter


Table 13
WT1151GP Smart Gage Pressure Transmitter
WT2000GP Smart Gage Pressure Transmitte
Code WT1151GP Measuring range(kPa) WT2000GP Measuring range(kPa)
3 0-0.75~7.5 0-0.188~7.5
4 0-3.74~37.4 0-0.935~37.4
5 0-18.68~186.8 0-4.67~186.8
6 0-68.9~689 0-17.24~690
7 0-206.8~2068 0-51.7~2068
8 0-689~6890 0-172.25~6890
9 0-2068~20680 0-517~20680
0 0-4137~41370 0-1034.2~41370
Code Output
S Smart 4~20mA DC in conformity with HART communication protocol
Structual material
Code
Flange connector Vent/drain valve Isolating diaphragm Filled liquid
22 316 stainless steel 316 stainless steel 316 stainless steel
Silicon oil
23 316 stainless steel 316 stainless steel Hastelloy C-276
Code Indicator
M1 0~100% linear indicator(only for WT1151)
M3 LCD digital indicator
Code Installation bracket
B01 Bending bracket mounted by pipe(carbon steel)
B02 Bending bracket mounted by panel(carbon steel)
B03 Flat bracket mounted bypipe(carbon steel)
B04 Bending bracket mounted by pipe(stainless steel)
B05 Bending bracket mounted by panel(stainless steel)
B06 Flat bracket mounted by pipe(stainless steel)
Code Pressure chamber
D1 Release valve located on upper of pressure chamber side
D2 Release valve located on lower of pressure chamber side
D3 Release valve located on the opposite of the process connecting port
V0 Vertically mounted pressure chamber (only for WT2000)
V1 Vertically mounted pressure chamber with side release (only for WT2000)
Code Connector
C1 NPT1/2 female thread oval flange
NPT1/2 induced pressure connector with 14 induced pressure
C12
tube welded behind
C2 M20 1.5 T-shaped male thread connecting block
M20 1.5 T-shaped male thread connecting block with 14
C21 induced pressure tube welded behind
Code Safe grade
d Flameproof Exd II BT4(WT1151)/CT3~T6(WT2000)
i Intrinsical safe Exia II CT6(WT1151)/CT3~T6(WT2000)
Code Cleaning
1 Degreasing on surface(only for WT2000)

WT1151GP 0 S 22 M1 B01 D2 C1 d WT1151GP model selection example


WT2000GP 9 S 22 M3 B01 D2 C1 i 1 WT2000GP model selection example

20 SHANGHAI WELLTECH AUTOMATION CO., LTD


WT1151 WT2000AP Absolute Pressure Transmitter Model Selection

1.2.4 WT1151 WT 2000AP Absolute Pressure Transmitter


WT1151 WT2000AP absolute pressure transmitter may measure absolute pressure of the deaerating
system, the distillation tower, the evaporator and the crystallizer etc., and can withstand 10MPa overpressure.
Service: liquid, gas and steam.
Output: 4~20mA DC in conformity with HART communication protocol.

Model and Ordering Code for AP Absolute Pressure Transmitter

Table 13
WT1151AP Smart Absolute Pressure Transmitte
WT2000AP Smart Absolute Pressure Transmitte
Code WT1151AP Measuring range kPa WT2000AP Measuring range kPa
4 0 10 37.4 0 10 37.4
5 0 18.68 186.8 0 10 186.8
6 0 68.9 689 0 17.24 690
7 0 206.8 2068 0 51.7 2068
8 0 689 6890 0 172.25 6890
Code Output
S Smart 4-20mA DC in conformity with HART communication protocol
Structual material
Code
Flange connector Vent/drain valve Isolating diaphragm Filled liquid
22 316 stainless steel 316 stainless steel 316 stainless steel
Silicon oil
23 316 stainless steel 316 stainless steel Hastelloy C-276
Code Indicator
M1 0~100% linear indicator(only for WT1151)
M3 LCD digital indicator
Code Installation bracket
B01 Bending bracket mounted by pipe(carbon steel)
B02 Bending bracket mounted by panel(carbon steel)
B03 Flat bracket mounted bypipe(carbon steel)
B04 Bending bracket mounted by pipe(stainless steel)
B05 Bending bracket mounted by panel(stainless steel)
B06 Flatbracketmountedby pipe(stainless steel)
Code Pressure chamber
D1 Release valve located on upper of pressure chamber side
D2 Release valve located on lower of pressure chamber side
D3 Release valve located on the opposite of the process connecting port
V0 Vertically mounted pressure chamber (only for WT2000)
V1 Vertically mounted pressure chamber with side release (only for WT2000)
Code Connector
C1 NPT1/2 female thread oval flange
NPT1/2 induced pressure connector with 14 induced pressure
C12
tube welded behind
C2 M20 1.5 T-shaped male thread connecting block
M20 1.5 T-shaped male thread connecting block with 14
C21 induced pressure tube welded behind
Code Safe Grade
d Flameproof Exd II BT4(WT1151)/CT3~T6(WT2000)
i Intrinsical safe Exia II CT6(WT1151)/CT3~T6(WT2000)
Code Cleaning
1 Degreasing on surface(only for WT2000)

WT1151AP 5 S 22 M1 B01 D2 C1 d WT1151AP model selection example


WT2000AP 4 S 22 M3 B01 D2 C1 i 1 WT2000AP model selection example

SHANGHAI WELLTECH AUTOMATION CO., LTD 21


WT1151 WT2000LT Flanged Level Transmitter Model Selection

1.2.5 WT1151 WT2000LT Flanged Level


Transmitter
The mounting flange of WT1151 WT2000LT
capacitive level transmitter adopts ANSI3 , 4 (with the
flange rating Class 150, Class 300, Class 600) or DN80
(with the flange rating 1.6/4.0MPa, 6.4MPa, 10MPa). The
installation dimensions are shown in the following Table
15. If customer follows GB9116-88 standard, DN shall be
equal to 80 or 100, and PN to 2MPa. There are 316L,
Hastelloy C-276, tantalum etc. for material of the wetted
diaphragm. Our company can also offer other special
mounting flange according to the requirement of
customer. Unless otherwise specified, our company will
supply the mounting flange of 3 , Class 150.
Fig. 15 WT1151LT Flanged Level
Transmitter Outline

NPT 1 / 4 while without connector

Sealing face

Inserted depth 50,100,150mm

n-d
Hole distributed diameter
Nameplate Release valve

Fig.16 Outline Dimension for WT1151LT Flanged Level Transmitter

22 SHANGHAI WELLTECH AUTOMATION CO., LTD


WT1151 WT2000LT Flanged Level Transmitter Model Selection

Fig.17 WT2000LT Flanged Level Transmitter Outline


n-d
Hole distributed diameter
Release valve

NPT 1 / 4 while without connector


Sealing face

Inserted depth 50,100,150mm

Fig.18 Outline Dimension for WT2000LT Flanged Level Transmitter

SHANGHAI WELLTECH AUTOMATION CO., LTD 23


WT1151 WT2000LT Flanged Level Transmitter Model Selection

Table 15 Dimension for Flange in Fig.16 18


Thread Required
Nominal Diameter Rated Pressure D D1 B C A
Qty. Thread
DN50
(Sealing face DIN 2526 E) 165 125 48.3 102 20 4 M16
(Flange DIN 2501)
DN80
(Sealing face DIN 2526 E) 200 160 76 127 24 8 M16
(flange DIN 2501 215 170 76 127 28 8 M20
DN2''
(ANSI B 16.5 R F ) Class 150 152.4 120.6 48.3 92.1 17.4 4 M16

DN 3 Class 150 190.5 152.4 76 127 22.2 4 M16


(ANSI B 16.5 R F ) Class 300 209.5 168.3 76 127 27.0 8 M20
DN 4 Class 150 229 191 89 157 30 8 M18
(ANSI B 16.5 R F ) Class 300 255 200 89 157 32 8 M20

Model and Ordering Code for LT Flanged Level Transmitter


Tabel 16
WT1151LT Smart Level Transmitter
WT2000LT Smart Level Transmitter
Code WT1151LT Measuring range kPa WT2000LT Measuring range kPa
4 0-3.74 37.4 0-0.935 37.4
5 0-18.68 186.8 0-4.67 186.8
6 0-68.9 689 0-17.24 690
Code Output
S Smart 4 20mA DC in conformity with HART communication protocol
Code Nominal diameter Inserted cylinder length mm Diaphragm material on high pressure side
A0 DN80/DN3 Flat flange 316L
A2 DN80/DN3 50 316L
A4 DN80/DN3 100 316L
A6 DN80/DN3 150 316L
B0 DN100/DN4 Flat flange 316L
B2 DN100/DN4 50 316L
B4 DN100/DN4 100 316L
B6 DN100/DN4 150 316L
G0 DN2 Flat flange 316L
G2 DN2 50 316L
G4 DN2 100 316L
G6 DN2 150 316L
J0 DN50 Flat flange 316L
J2 DN50 50 316L
J4 DN50 100 316L
J6 DN50 150 316L
C0 DN80/DN3 Flat flange Hastelloy C-276
C2 DN80/DN3 50 Hastelloy C-276
C4 DN80/DN3 100 Hastelloy C-276
C6 DN80/DN3 150 Hastelloy C-276
D0 DN100/DN4 Flat flange Hastelloy C-276
D2 DN100/DN4 50 Hastelloy C-276
D4 DN100/DN4 100 Hastelloy C-276
D6 DN100/DN4 150 Hastelloy C-276

24 SHANGHAI WELLTECH AUTOMATION CO., LTD


WT1151 WT2000LT Flanged Level Transmitter Model Selection

H0 DN2 Flat flange Hastelloy C-276


H2 DN2 50 Hastelloy C-276
H4 DN2 100 Hastelloy C-276
H6 DN2 150 Hastelloy C-276
K0 DN50 Flat flange Hastelloy C-276
K2 DN50 50 Hastelloy C-276
K4 DN50 100 Hastelloy C-276
K6 DN50 150 Hastelloy C-276
E0 DN80/DN3 Flat flange Tantalum
F0 DN100/DN4 Flat flange Tantalum
I0 DN2 Flat flange Tantalum
L0 DN50 Flat flange Tantalum
Code Installation flange
A DN3'' Class150 stainless steel
B DN4'' Class150 stainless steel
G DN2'' Class150 stainless steel
C DN3'' Class300 stainless steel
D DN4'' Class300 stainless steel
E DN80 PN1.6MPa/4MPa stainless steel
J DN50 PN1.6MPa/4MPa stainless steel
F DN80 PN6.4MPa stainless steel
Structual material of sensor part
Code
Flange connector Vent/drain valve Isolatingv diaphragm Filled liquid
22 316 stainless steel 316 stainless steel 316 stainles ssteel
Silicon oil
23 316 stainless steel 316 stainless steel Hastelloy C-276
Code Indicator
M1 0~100% linear indicator (only for WT1151)
M3 LCD digital indicator
Code Pressure chamber
D1 Release valve located on upper of pressure chamber side
D2 Release valve located on lower of pressure chamber side
D3 Release valve located on the opposite of the process connecting port
Code Connector
C1 NPT1/2 female thread oval flange
NPT1/2 induced pressure connector with 14 induced
C12 pressure tube welded behind
C2 M20 1.5 T-shaped male thread connecting block
M20 1.5 T-shaped male thread connecting block with
C21
14 induced pressure tube welded behind
Code Safe grade
d Flameproof Exd II BT4(WT1151)/CT3~T6(WT2000)
i Intrinsical safe Exia II CT6(WT1151)/CT3~T6(WT2000)
Code Cleaning
1 Degreasing on surface(only for WT2000)

WT1151LT 4 S A0 C 22 M1 D2 C12 d WT1151LT model selection example


WT2000LT 5 S B6 B 22 M3 D2 C12 i 1 WT2000LT model selection example

SHANGHAI WELLTECH AUTOMATION CO., LTD 25


WT1151 WT2000DP/GP Differential /Gage Pressure Transmitter with Remote Seal Model Selection

1.2.6 WT1151 WT2000DP/GP Differential/Gage Pressure Transmitter with Remote Seal

When WT1151 WT2000DP/GP transmitter is equipped with the remote seal it will become WT1151
WT2000DP/GP differential/gage pressure transmitter with remote seal. WT1151 WT2000DP/GP
differential/gage pressure transmitter with remote seal can prevent the isolating diaphragm of the transmitter
from being directly touched with the measured medium. It is applicable to the following situations:
1. The measured medium will bring corrosion to the transmitter connector and the sensitive element;
2. The high temperature medium is necessary to be isolated from the transmitter;
3. There are suspended solid particles in the measured medium or high-viscous, which will easily result in
plugging of transmitter connector and pressure chamber;
4. The measured medium is easy to solidify or crystallize when being induced out by induced pressure
tube;
5.Water flush is needed before the measured medium is changed while the measured medium not allow of
mixing.
6. It is required to maintain the sanitary condition and prevent from pollution.
WT1151 WT2000DP/GP differential/gage pressure transmitter with remote seal combines WT1151
WT2000DP/GP differential/gage pressure transmitter with the remote seal, so it still owns all the characteristics
of WT1151 WT2000DP/GP differential/gage pressure transmitter.
Measuring range is 0~6kPa to 0~7MPa.
Various structual materials are available. The remote seal device adopts the welding structure, which
ensures high reliability. The filled liquid chamber adopts low volume design to reduce the temperature
influence. According to the requirement of the customer, the application temperature for ordinary filled silicon
oil is 40~149 , and for high temperature silicon oil 15~315 . For the details, please refer to Table 26.
The upper limit of working pressure for the remote seal is the rated pressure of the remote seal chosen by
the customer. The working pressure shall not be less than 35kPa (absolute pressure).

26 SHANGHAI WELLTECH AUTOMATION CO., LTD


WT1151 WT2000DP/GP Differential /Gage Pressure Transmitter with Remote Seal Model Selection

Outline Dimension for WT1151DP/GP Differential/Gage Pressure Transmitter with Remote Seal

177 (with field indicator)

177 (with field indicator)

Fig.19 Outline Dimension for WT1151DP/GP Differential /Gage Pressure Transmitter with Remote Seal

SHANGHAI WELLTECH AUTOMATION CO., LTD 27


WT1151 WT2000DP/GP Differential /Gage Pressure Transmitter with Remote Seal Model Selection

Outline Dimension for WT2000DP/GP Differential/Gage Pressure Transmitter with Remote Seal

Fig.20 Outline Dimension for WT2000DP/GP Differential/Gage Pressure Transmitter with Remote Seal

28 SHANGHAI WELLTECH AUTOMATION CO., LTD


WT1151 WT2000DP/GP Differential /Gage Pressure Transmitter with Remote Seal Model Selection

Customer's process connecting flange

Remote seal flange

Customer's flange

Fig.21 Outline Dimension for 1199PFW Flat Remote Seal ( DN 3'', Working Pressure 2.5MPa)

Fig.22 Outline Dimension for 1199PFW-1 Flat Remote Seal

Inserted depth 50,100,150

Fig.23 Outline Dimension for 1199EFW Inserted Cylinder Remote Seal

SHANGHAI WELLTECH AUTOMATION CO., LTD 29


WT1151 WT2000DP/GP Differential /Gage Pressure Transmitter with Remote Seal Model Selection

Table 17 Dimension for 1199PFW-1/1199EFW Remote Seal


Thread Required
Nominal Diameter Rated Pressure D D1 B C A
Qty. Thread
DN50
(Sealing face DIN 2526 E) 165 125 57 102 20 4 M16
(Flange DIN 2501) 180 135 57 102 26 4 M20
DN80
(Sealing face DIN 2526 E) 200 160 75 138 24 8 M16
(Flange DIN 2501) 215 170 75 138 28 8 M20

DN 2 Class 150 152.4 120.6 57 92.1 17.4 4 M16


(ANSI B 16.5 R F ) Class 300 165.1 127.0 57 92.1 20.6 8 M16

DN 3 Class 150 190.5 152.4 75 127 22.2 4 M16


(ANSI B 16.5 R F ) Class 300 209.5 168.3 75 127 27.0 8 M20
DN 4 Class 150 229 191 89 157 30 8 M18
(ANSI B 16.5 R F ) Class 300 255 200 89 157 32 8 M20

Upper sleeve flange

Upper sleeve flange


Sealing ring

Lower sleeve

Lower sleeve

Flush hole NPT 1/4


Sealing ring Flush hole NPT 1/4

Fig.24 Outline Dimension for 1199RFW Fig.25 Outline Dimension for 1199RTW Threaded
Flanged Remote Seal Remote Seal (Max. Working Pressure 10MPa)

Table 18 Dimension for1199RFW Flanged Remote Seal

Dimension for upper sleeve flange Dimension for lower sleeve flange

Nominal Nominal Thickness


Outside Center Bolt Hole Bolt Hole Diameter Diameter
Diameter Pressure of Bolt
Diameter A Distance B Quantity n d E(mm) F(mm)
(inch) (Class/MPa) Hole D
150/2 110 14.3 79.5 4 16
1 26.9 66.5
300/5 125 17.2 89 4 20
150/2 127 17.2 98.4 4 16
1 1/2 41.9 78.7
300/5 156 20.7 114.5 4 23
150/2 152 19.1 120.6 4 20
2 52.5 95.2
300/5 165 22.2 127 8 20
150/2 191 23.8 152.4 4 20
3 79 127
300/5 210 25.5 168.3 8 23

30 SHANGHAI WELLTECH AUTOMATION CO., LTD


WT1151 WT2000DP/GP Differential /Gage Pressure Transmitter with Remote Seal Model Selection

Model and Ordering Code for DP/GP Differential/Gage Pressure Transmitter with Remote Seal
Table 19
WT1151DPYC/GPYC Smart Differential /Gage transmitter with remote seal
WT2000DPYC/GPYC Smart Differential /Gage transmitter with remote seal
Code WT1151 Measuring range(kPa)
4 0 6.2 37.4
5 0 31.1 186.8
6 0 117 690
7 0 345 2068
8 0 1170 6890
Code Output
S Smart 4-20mA DC in conformity with HART communication protocol
Code Flange connector Isolating diaphragm
22 316LSST 316LSST
S1 One remote seal device(mating with GPYC) According to Table 20 21 22 23
S2 Two remote seal devices(mating with DPYC) 24 25 to place ordering
Code Indicator
M1 0~100% linear display(only for WT1151)
M3 LCD digital display
Code Installation bracket
B01 Bending bracket mounted by pipe(carbon steel)
B02 Bending bracket mounted by panel(carbon steel)
B03 Flat bracket mounted by pipe(carbon steel)
B04 Bending bracket mounted by pipe(stainless steel)
B05 Bending bracket mounted by panel(stainless steel)
B06 Flat bracket mounted by pipe(stainless steel)
Code Safe grade
d Flameproof Exd II BT4(WT1151)/CT3~T6(WT2000)
i Intrinsical safe Exia II CT6(WT1151)/CT3~T6(WT2000)
Code Cleaning
1 Degreasing on surface(only for WT2000)
Code Type of remote seal device
1199PFW Flat
1199PFW-1 Flat
1199RTW Screwed
1199EFW Inserted cylinder
1199RFW Flanged

WT1151DPYC 4 S 22 S2 M1 B01 d 1199PFW Model Selection example


1199PFW11A11-755 Refer toTable 20-25

SHANGHAI WELLTECH AUTOMATION CO., LTD 31


WT1151 WT2000DP/GP Differential /Gage Pressure Transmitter with Remote Seal Model Selection

Ordering Code for Flat Remote Seal Device


Table 20
1199PFW Flat Remote Seal Device
Code Measuring range (kPa)
11 DN3 Class 150
13 DN2 Class 150
23 DN50 PN1.6MPa/4MPa
24 DN80 PN1.6MPa/4MPa
Code Diaphragm material of remote seal device
A 316LSST
B HastelloyC-276
C Tantalum
Code Housing material
11 316SST

1199PFW 11 A 11 Model selection example for flat remote seal device

Table 21
1199PFW-1 Flat Remote Seal Device
Code Measuring range (kPa)
11 DN3 Class 150
12 DN4 Class 150
13 DN2 Class 150
15 DN3 Class 300
16 DN4 Class 300
17 DN2 Class 300
23 DN50 PN1.6MPa/4MPa
24 DN80 PN1.6MPa/4MPa
25 DN50 PN6.4MPa
26 DN80 PN6.4MPa
Code Diaphragm material of remote seal device
A 316LSST
B HastelloyC-276
C Tantalum

1199PFW-1 11 A Model selection example for flat remote seal device

32 SHANGHAI WELLTECH AUTOMATION CO., LTD


WT1151 WT2000DP/GP Differential /Gage Pressure Transmitter with Remote Seal Model Selection

Ordering Code for Threaded Remote Seal Device


Table 22

Structual material
Upper sleeve is 316SST, installation ring is galvanized carbon steel, and gasket is
asbestos or viton, buna

Upper sleeve is 316SST, installation ring is 316SST, and gasket is asbestos or viton, buna

Induced pressure port

Ordering Code for Inserted Cylinder Remote Seal Device


Table 23
1199EFW Inserted Cylinder Remote Seal Device
Code Type
11 DN3 Class 150
12 DN4 Class 150
13 DN2 Class 150
15 DN3 Class 300
16 DN4 Class 300
17 DN2 Class 300
23 DN50 PN1.6MPa/4MPa
24 DN80 PN1.6MPa/4MPa
25 DN50 PN6.4MPa
26 DN80 PN6.4MPa
Code Diaphragm material of remote seal device
A 316LSST
B Hastelloy C-276
Code Length of inserted cylinder
20 ( 2 ) 50mm
40 ( 4 ) 100mm
60 ( 6 ) 150mm

1199EFW 11 A 60 Model selection example for flatremote seal

SHANGHAI WELLTECH AUTOMATION CO., LTD 33


WT1151 WT2000DP/GP Differential /Gage Pressure Transmitter with Remote Seal Model Selection

Ordering Code for Flanged Remote Seal Device


Table 24

Structual material
Upper sleeve is 316SST, uppel sleeve flange is galvanized carbon steel, and gasket is
asbestos or viton

Upper sleeve is 316SST, uppel sleeve flange is 316SST, and gasket is asbestos or viton

34 SHANGHAI WELLTECH AUTOMATION CO., LTD


WT1151 WT2000DP/GP Differential /Gage Pressure Transmitter with Remote Seal Model Selection

Ordering Code for Capillary


Table 25
1199CAP Material 304 dimension 3 1
Code Length of capillary
755 1.0m
757 2.0m
759 4.0m
760 6.0m
761 8.0m
764 Special
Code Protection sleeve
No marking Armoured 304
A PVC protection sleeve, armoured304

1199CAP 755 A Model selection example

755A Simplified model seection example

Characteristic of Filled Liquid


Table 26

Note: The temperature limit is reduced under vacuum circumstance (<50kPa absolute pressure), which should be specified in
ordering.
If pressure exceeds 590kPa, the temperature can be up to 315 ; otherwise, the temperature is below 315 .
Ordering code should be written after the code of capillary.
For example: WT1151DP4S22S2M1B01
1199RFW21A11A21-S
Covered Film of Remote Flange
F46 Cover F46 film to isolating diaphragm
Note: F46 only applicable to situation of positive pressure and remote flange filled with ordinary silicon oil;
Ordering code F46 only applicable to level transmitter, PFW-1 and PFW remote seal device;
F46 will be covered by user self while installing flange.
For example: WT1151DP4S22S2M1B01
1199PFW-1 11A-F46

SHANGHAI WELLTECH AUTOMATION CO., LTD 35


WT2000TG Smart Directly Mounted Pressure Transmitter Model Selection

1.2.7 WT2000TG Smart Directly Mounted Pressure


Transmitter
WT2000TG smart directly mounted pressure transmitter adopts
the mature metal capacitive sensor and advanced sensor from America
as sensitive element, and with high performance and price ratio.
Since it is featured with stability and reliability, compact and
strong structure etc., It is widely used in petrochemical, power station,
water treatment, food making and other industries which needs a high
requirement for pressure measuring, and enjoys a rather good
reputation in the field.
WT2000TG directly mounted pressure transmitter (gage pressure)
Measuring range: 0-0.935kPa~35000kPa.
Service: liquid, gas and steam.
Output: smart, 4~20mA DC, in conformity with HART
communication protocol.

133.5 (with field indicator)


A

For range code 4 5 6 7 A = 170mm


For range code 8 9 0 A = 185mm

Fig.26 Outline Dimension for WT2000TG Smart Directly Mounted Pressure Transmitter

36 SHANGHAI WELLTECH AUTOMATION CO., LTD


WT2000TG Smart Directly mounted Pressure Transmitter Installation Accessories

Model and Ordering Code for WT2000TG Smart Directly Mounted Pressure Transmitter
Table 27
WT2000TG Smart Directly Mounted Pressure Transmitter
Code Measuring range kPa
4 0 0.935 37.4
5 0 4.67 186.8
6 0 17.24 690
7 0 51.7 2068
8 0 172.25 6890
9 0 517 20680
0 0 1034.2 35000
Code Output
S Smart 4-20mA DC in conformity with HART communication protocol
Code Connection type
A M20 1.5 male thread
B NPT1/2 male thread
C G1/2 male thread
D NPT1/2 female thread
E NPT1/4 female thread
Code Indicator
M3 LCD digital indicator
Code Installation bracket
B11 Bracket mounted on wall CS for range code 4 5 6 7
B12 Flat bracket mounted by pipe CS for range code 4 5 6 7
B13 Bracket mounted on wall SS for range code 4 5 6 7
B14 Flat bracket mounted by pipe SS for range code 4 5 6 7
B15 Flat bracket mounted by pipe CS for range code 8 9 0
B16 Bracket mounted on wall CS for range code 8 9 0
B17 Flat bracket mounted by pipe SS for range code 8 9 0
B18 Bracket mounted on wall SS for range code 8 9 0
Code Safe grade
d Flameproof Exd CT3 T6
i Intrinsical safe Exia CT3 T6
Code Cleaning
1 Degreasing on suface

WT2000TG 5 S A M3 B11 d 1 WT2000TG model selection example

SHANGHAI WELLTECH AUTOMATION CO., LTD 37


WT1151 WT2000 Series Smart Capacitive Pressure Transmitter Installation Accessories

1.3 Installation Accessories


1.3.1 Installation Bracket and Installation Type

Fig.27 Bending Bracket Mounted by Pipe Ordering Code B01/B04

Installation hole

Fig.28 Bending Bracket Mounted by Panel Ordering Code B02/B05

38 SHANGHAI WELLTECH AUTOMATION CO., LTD


WT1151 WT2000 Series Smart Capacitive Pressure Transmitter Installation Accessories

Fig.29 Flat Bracket Mounted by Pipe Ordering Code B03/B06

1.3.2 Installation Bracket and Installation Type for Directly Mounted

133.5 (with
133.5 field indicator) 133.5 (with
133.5 field indicator)

Gap for opening the Gap for opening the


cover 20mm cover 20mm

Hoop Hoop
Installation

Installation
bracket

bracket

Installation bracket
Flat bracket mounted by 2 pipe Bracket mounted on wall
(Code B12/B14/B15/B17) (Code B11/B13/B16/B18)

SHANGHAI WELLTECH AUTOMATION CO., LTD 39


WT1151 WT2000 Series Smart Capacitive Pressure Transmitter Installation Accessories

1.3.3 Induced Pressure Connector

1. Pressure chamber flange 2. O ring 3. NPT1/2 oval flange 4. Bolt M10 40


NPT1/2 Thread Connector(Code C1)

1. NPT1/2 transitional connector 2. Nut M20 1.5 3. Sealing ring 4. 14 induced pressure tube
NPT1/2 Thread Transitional Induced Pressure Connector (Code C12)

1. Pressure chamber flange 2. M20 1.5 T-shaped male thread connector 3. Bolt 4. O ring
M20 1.5 T-shaped Male Thread Connection Block(Code C2)

1. Pressure chamber flange 2. Bolt 3. M20 1.5 T-shaped male thread connector 4. O ring; 5. Nut M20 1.5
6. 14 induced pressure tube
M20 1.5 Thread Connector (Code C21)

Fig.30 Induced Pressure Connector

40 SHANGHAI WELLTECH AUTOMATION CO., LTD


WT1151 WT2000 Series Smart Capacitive Pressure Transmitter Installation Accessories

1.3.4 Connection Dimension for Process Flange


If customer orders WT1151 WT2000LT flanged level transmitter or WT1151 WT
2000DP/GP differential/gage pressure transmitter with remote seal device of EFW RFW , the
following drawing is for reference for dimensions of 3'', 4'' Class 150 process connection
flange(used for installing the flange, and offered by customer self) and the sealing gasket.

Evenly distributed

Fig.31 Customer's Process Connection Flange for 3'' Class 150 Flange(D Determined by Customer) (for Reference)

Evenly distributed

Fig.32 Customer's Process Connection Flange for 4'' Class 150 Flange (D Determined by Customer) (for Reference)

Table 28 Dimension for Sealing Gasket of Flange

Mating flange D d

3 127 80

4 157 95
Fig.33 Sealing Gasket of Flange

The customer may select the material of the sealing gasket of flange at his own option
according to the characteristic of the measured medium. Our company recommends using such
material as asbestos rubber, buna, viton, nylon, or PTFE etc.

SHANGHAI WELLTECH AUTOMATION CO., LTD 41