WT1151 WT2000 series smart capacitive pressure transmitters have been self-developed and produced
by Welltech through introducing overseas sophisticated equipment and benefiting from the advanced
technology & successful experience of overseas similar products. WT1151 WT2000 adopt international
high quality electronic components and key parts, and are supplied to domestic and overseas customers at
most competitive price popularly.
The guidebook only makes a general introduction of the common characteristics for the WT1151
WT2000 series transmitters, including the model denomination, product series, main features, working
principles, function parameters. For the detailed information, please refer to the Operation Manual of
WT1151 WT2000 series capacitive transmitters.
WT1151 WT2000
HP High static differential pressure transmitter 22 316 stainless steel 316 stainless steel 316L stainless steel
Silicon oil
AP Absolute pressure transmitter 23 316 stainless steel 316 stainless steel Hastelloy C-276
Code WT1151 Measuring Range(kPa) B02 Bending bracket mounted by panel (carbon steel)
0 0 4137 41370 V1 Vertically mounted pressure chamber with side release (only for WT2000)
Code WT2000 Measuring Range(kPa) C1 NPT1/2 female thread oval flange
2 0 0.1 1.5 NPT1/2 induced pressure connector with 14 induced pressure tube welded
C12 behind
3 0 0.188 7.5 C2 M20*1.5 T-shaped male thread connecting block
M20*1.5 T-shaped male thread connecting block with 14 induced pressure
4 0 0.935 37.4 C21 tube welded behind
5 0 4.67 186.8 d Flameproof Exd II BT4
6 0 17.24 690 i Intrinsical safe Exia II CT6
7 0 51.7 2068
Table 3
Table 4
it is also engaged in such operations as the sensor linearization, resetting measuring range, engineering unit
conversion, damping, square root and sensor trim, as well as diagnosis and digital communication.
4~20mA
4~20mA
Oscillation and modulation
D/A
To control system
A/D signal conversion
D/A convertor changes the digital signal, which have been calibrated by the microprocessor, into the 4
~20mA analog signal and then transfers to the output loop. EEPROM stores all the configurations,
characterization and digital trim data, which could be altered by the transmitter software. The data are stored in
the EEPROM, which ensure it stored completely even if in case of outage.
The digital communication circuit offers the transmitter with a connection interface to outside device (such
as 275 smart hand held communicator or the control system adopting HART protocol). The circuit detects the
digital signal overlapping upon 4 ~20mA signal, and transfers the needed information through the loop. The
communication type adopts frequency shift keying technology FSK (Frequency Shift Keying) and conforms to
Bell 202 standard.
Table 5
Accuracy Grade
Range Code or Name
0.1 0.2
2 / 0.30%
3 0.20% 0.30%
4 9 0.10% 0.30%
0 / 0.30%
Remote seal, level / /
Table 6
Accuracy Grade
Range Code or Name
0.1 0.2
2 / 0.5% / 7MPa
3 0.30% / 14MPa 0.5% / 14MPa
4,5,6,7,8 0.25% / 14MPa 0.30% / 14MPa
High static 4,5,6,7 / 2% / 32MPa
2
Vibration effect: 0.1% of max. span, 10 ~ 60Hz, S = 0.07mm, 60 ~ 150Hz, g = 9.8m/s ; in any direction.
Power supply effect: less than 0.005% of output span/V.
Electromagnetic radiation effect: 0.1% of max. span, radiation frequency 27~500MHz, test magnetic strength
3V/m.
Electro magnetic compatibility (EMC): see Table 7 (for WT2000).
Installation position impact: the working diaphragm not in vertical will result in a zero system error of zero of
no more than 0.24kPa, which could be offset by adjusting zero and bring no impact to span.
Structure material: for the material for such wetted parts as pressure chamber, connector, release valve,
isolating diaphragm etc., please refer to the model and ordering code of different models.
l the bolts is the galvanized carbon steel
l The electrical housing is low copper aluminum alloy, with the epoxy sprayed coating on surface.
Induced pressure connection: the connecting screws of the pressure chamber are NPT1/4, the connecting screws
of the induced pressure connectors are NPT1/2, and the center distance can be altered by adjusting the
connection block (51, 54, 57mm).
Electrical connection: two screws of M20 1.5 or NPT 1/2 female screws are available on the transmitter
housing to connect the cable duct. Inside the housing, there are cable terminals and measuring shims
offered for testing. For connection with communicator, it could only be connected onto the measuring
shims.
Weight: about 5kg for WT1151 (excluding accessories, except flanged pressure transmitter),
about 3.5kg for WT2000 (excluding accessories, except flanged pressure transmitter).
No. Test Item Test Standards Test Method/ Performance Test Result
Condition Class
4kV(contact)
3 Electrostatic discharge B Pass
8kV(air)
80MHz ~ 1000MHz
4 EM field 10V / m A Pass
80% AM
Continued Table 7
No. Test Item Test Standards Test Method/ Performance Test Result
Condition Class
30A/m
Rated power frequency
5 Direction: transverse A Pass
magnetic field
longitudinal and vertical
2kV.5 / 50(Tr / Tn)ns
6 Burst 5kHz(+ / ) B Pass
1kV(differential mode)
7 Surge 2kV(common mode) B Pass
1.2ìs /50ìs
0.15MHz~80MHz
8 Conducted RF 10V A Pass
80% AM
Sensor adjusting: including the characterization and sensor trim, this enables the electronic part to precisely
reflect the pressure input. Meanwhile, the standard pressure source must be adopted.
l Characterization: although WT1151 WT2000 smart transmitter has been characterized before leaving the
factory, the client can still use this function, to make some simple update for WT1151 analog pressure
transmitter to convert to smart type.
Characterization function: adjusting the electronic part of WT1151 WT2000 smart transmitter to make
sure it reflects the sensor output correctly.
l Sensor trim: the function allows the characterized digital to be micro-adjusted. It affects originally
characterized results. For the detailed information, please refer to the manual.
Analog adjusting: make the digital current valu e of the transmitter be co nsistent with the 4~20mA analog
current of the transmitter.
Note: Please read the manual before implementing the adjusting.
Configuration
Standard configuration: the goods would be provided according to the following configurations, unless
otherwise specified: engineering unit--kPa; 4mA--0kPa; 20mA--upper range limit (URL) ; output--linear
Software tag: blank [software tag(8 characters), blank unless otherwise specified]
Special configuration: in addition to the standard configuration data, the clients can also designate the
following additional data(Table 8).
Table 8
Flange material Type code information Fault alarm mode High or low
O ring material Type code information Parameter writing protection Off /on
Power supply
Ammeter
HART
Communicator
Fig.5 Field Wiring Diagram for WT1151 WT2000 Smart Capacitive Transmitter
HART
serial interface
Fig.6 Multi-station Communication Sketch Drawing for WT1151 WT2000 Smart Capacitive Transmitter
Warranty
With respect to the failed transmitter due to the inherent quality problem, our company promises
to repair or replace the product free of charge within 18 months after the delivery of the goods on the
premise that the failed transmitter should be sent back to our company. In the case of repairing
and replacing the products out of the warranty period, our company will charge the due cost.
92
198
Vertically Mounted
Pressure Chamber
1. Nameplate;
2. NPT1/4 screw for connecting with the release valve (on upper or on lower);
3. Pressure chambe, turnable;
4. Release valve;
5. NPT1/4 screw on the pressure chamber for induced pressure connection.
Table 9
Note: Dimension A changed while the oval flange is turned, i.e. A 3mm
Model and Ordering Code for HP High Static Differential Pressure Transmitter
Table 11
WT1151HP Smart High Static Differential Pressure Transmitter
WT2000HP Smart High Static Differential Pressure Transmitte
Code WT1151HP Measuring range(kPa) WT2000HP Measuring range(kPa)
4 0-3.74 37.4 0-0.935 37.4
5 0-18.68 186.8 0-4.67 186.8
6 0-68.9 689 0-17.24 690
7 0-206.8 2068 0-51.7 2068
Code Output
S Smart 4 20mA DC in conformity with HART communication protocol
J Smart 4 20mA DC square root output in conformity with HART communication protocol
Structual Material
Code
Flange connector Vent/drain valve Isolating diaphragm Filled liquid
22 316 stainless steel 316 stainless steel 316 stainless steel Silicon oil
Code Max.Working pressure MPa
No marking 25
F- 32
Code Indicator
M1 0~100% linear indicator (only for WT1151)
M3 LCD digital indicator
Code Installation bracket
B01 Bending bracket mounted by pipe(carbon steel)
B02 Bending bracket mounted by panel(carbon steel)
B03 Flat bracket mounted by pipe(carbon steel)
B04 Bending bracket mounted by pipe(stainless steel)
B05 Bending bracket mounted by panel(stainless steel)
B06 Flat bracket mounted by pipe(stainless steel)
Code Pressure chamber
D1 Release valve located on upper of pressure chamber side
D2 Release valve located on lower of pressure chamber side
D3 Release valve located on the opposite of the process connecting port
V0 Vertically mounted pressure chamber (only for WT2000)
V1 Vertically mounted pressure chamber with side release(only for WT2000)
Code Connector
C1 NPT1/2 female thread oval flange
NPT1/2 induced pressure connector with 14 induced
C12 pressure tube welded behind
Code Safe Grade
d Flameproof Exd II BT4(WT1151)/CT3~T6(WT2000)
i Intrinsical safe Exia II CT6(WT1151)/CT3~T6(WT2000)
Code Cleaning
1 Degreasing on surface(only for WT2000)
92
198
Vertically Mounted
Pressure Chamber
1. Nameplate;
2. NPT1/4 screw for connecting with the release valve (on upper or on lower);
3. Pressure chamber, turnabl;
4. Release valve;
5. NPT1/4 screw on the pressure chamber for induced pressure connection.
Table 12
Note: Dimension A changed while the oval flange is turned, i.e. A 3mm
Table 13
WT1151AP Smart Absolute Pressure Transmitte
WT2000AP Smart Absolute Pressure Transmitte
Code WT1151AP Measuring range kPa WT2000AP Measuring range kPa
4 0 10 37.4 0 10 37.4
5 0 18.68 186.8 0 10 186.8
6 0 68.9 689 0 17.24 690
7 0 206.8 2068 0 51.7 2068
8 0 689 6890 0 172.25 6890
Code Output
S Smart 4-20mA DC in conformity with HART communication protocol
Structual material
Code
Flange connector Vent/drain valve Isolating diaphragm Filled liquid
22 316 stainless steel 316 stainless steel 316 stainless steel
Silicon oil
23 316 stainless steel 316 stainless steel Hastelloy C-276
Code Indicator
M1 0~100% linear indicator(only for WT1151)
M3 LCD digital indicator
Code Installation bracket
B01 Bending bracket mounted by pipe(carbon steel)
B02 Bending bracket mounted by panel(carbon steel)
B03 Flat bracket mounted bypipe(carbon steel)
B04 Bending bracket mounted by pipe(stainless steel)
B05 Bending bracket mounted by panel(stainless steel)
B06 Flatbracketmountedby pipe(stainless steel)
Code Pressure chamber
D1 Release valve located on upper of pressure chamber side
D2 Release valve located on lower of pressure chamber side
D3 Release valve located on the opposite of the process connecting port
V0 Vertically mounted pressure chamber (only for WT2000)
V1 Vertically mounted pressure chamber with side release (only for WT2000)
Code Connector
C1 NPT1/2 female thread oval flange
NPT1/2 induced pressure connector with 14 induced pressure
C12
tube welded behind
C2 M20 1.5 T-shaped male thread connecting block
M20 1.5 T-shaped male thread connecting block with 14
C21 induced pressure tube welded behind
Code Safe Grade
d Flameproof Exd II BT4(WT1151)/CT3~T6(WT2000)
i Intrinsical safe Exia II CT6(WT1151)/CT3~T6(WT2000)
Code Cleaning
1 Degreasing on surface(only for WT2000)
Sealing face
n-d
Hole distributed diameter
Nameplate Release valve
When WT1151 WT2000DP/GP transmitter is equipped with the remote seal it will become WT1151
WT2000DP/GP differential/gage pressure transmitter with remote seal. WT1151 WT2000DP/GP
differential/gage pressure transmitter with remote seal can prevent the isolating diaphragm of the transmitter
from being directly touched with the measured medium. It is applicable to the following situations:
1. The measured medium will bring corrosion to the transmitter connector and the sensitive element;
2. The high temperature medium is necessary to be isolated from the transmitter;
3. There are suspended solid particles in the measured medium or high-viscous, which will easily result in
plugging of transmitter connector and pressure chamber;
4. The measured medium is easy to solidify or crystallize when being induced out by induced pressure
tube;
5.Water flush is needed before the measured medium is changed while the measured medium not allow of
mixing.
6. It is required to maintain the sanitary condition and prevent from pollution.
WT1151 WT2000DP/GP differential/gage pressure transmitter with remote seal combines WT1151
WT2000DP/GP differential/gage pressure transmitter with the remote seal, so it still owns all the characteristics
of WT1151 WT2000DP/GP differential/gage pressure transmitter.
Measuring range is 0~6kPa to 0~7MPa.
Various structual materials are available. The remote seal device adopts the welding structure, which
ensures high reliability. The filled liquid chamber adopts low volume design to reduce the temperature
influence. According to the requirement of the customer, the application temperature for ordinary filled silicon
oil is 40~149 , and for high temperature silicon oil 15~315 . For the details, please refer to Table 26.
The upper limit of working pressure for the remote seal is the rated pressure of the remote seal chosen by
the customer. The working pressure shall not be less than 35kPa (absolute pressure).
Outline Dimension for WT1151DP/GP Differential/Gage Pressure Transmitter with Remote Seal
Fig.19 Outline Dimension for WT1151DP/GP Differential /Gage Pressure Transmitter with Remote Seal
Outline Dimension for WT2000DP/GP Differential/Gage Pressure Transmitter with Remote Seal
Fig.20 Outline Dimension for WT2000DP/GP Differential/Gage Pressure Transmitter with Remote Seal
Customer's flange
Fig.21 Outline Dimension for 1199PFW Flat Remote Seal ( DN 3'', Working Pressure 2.5MPa)
Lower sleeve
Lower sleeve
Fig.24 Outline Dimension for 1199RFW Fig.25 Outline Dimension for 1199RTW Threaded
Flanged Remote Seal Remote Seal (Max. Working Pressure 10MPa)
Dimension for upper sleeve flange Dimension for lower sleeve flange
Model and Ordering Code for DP/GP Differential/Gage Pressure Transmitter with Remote Seal
Table 19
WT1151DPYC/GPYC Smart Differential /Gage transmitter with remote seal
WT2000DPYC/GPYC Smart Differential /Gage transmitter with remote seal
Code WT1151 Measuring range(kPa)
4 0 6.2 37.4
5 0 31.1 186.8
6 0 117 690
7 0 345 2068
8 0 1170 6890
Code Output
S Smart 4-20mA DC in conformity with HART communication protocol
Code Flange connector Isolating diaphragm
22 316LSST 316LSST
S1 One remote seal device(mating with GPYC) According to Table 20 21 22 23
S2 Two remote seal devices(mating with DPYC) 24 25 to place ordering
Code Indicator
M1 0~100% linear display(only for WT1151)
M3 LCD digital display
Code Installation bracket
B01 Bending bracket mounted by pipe(carbon steel)
B02 Bending bracket mounted by panel(carbon steel)
B03 Flat bracket mounted by pipe(carbon steel)
B04 Bending bracket mounted by pipe(stainless steel)
B05 Bending bracket mounted by panel(stainless steel)
B06 Flat bracket mounted by pipe(stainless steel)
Code Safe grade
d Flameproof Exd II BT4(WT1151)/CT3~T6(WT2000)
i Intrinsical safe Exia II CT6(WT1151)/CT3~T6(WT2000)
Code Cleaning
1 Degreasing on surface(only for WT2000)
Code Type of remote seal device
1199PFW Flat
1199PFW-1 Flat
1199RTW Screwed
1199EFW Inserted cylinder
1199RFW Flanged
Table 21
1199PFW-1 Flat Remote Seal Device
Code Measuring range (kPa)
11 DN3 Class 150
12 DN4 Class 150
13 DN2 Class 150
15 DN3 Class 300
16 DN4 Class 300
17 DN2 Class 300
23 DN50 PN1.6MPa/4MPa
24 DN80 PN1.6MPa/4MPa
25 DN50 PN6.4MPa
26 DN80 PN6.4MPa
Code Diaphragm material of remote seal device
A 316LSST
B HastelloyC-276
C Tantalum
Structual material
Upper sleeve is 316SST, installation ring is galvanized carbon steel, and gasket is
asbestos or viton, buna
Upper sleeve is 316SST, installation ring is 316SST, and gasket is asbestos or viton, buna
Structual material
Upper sleeve is 316SST, uppel sleeve flange is galvanized carbon steel, and gasket is
asbestos or viton
Upper sleeve is 316SST, uppel sleeve flange is 316SST, and gasket is asbestos or viton
Note: The temperature limit is reduced under vacuum circumstance (<50kPa absolute pressure), which should be specified in
ordering.
If pressure exceeds 590kPa, the temperature can be up to 315 ; otherwise, the temperature is below 315 .
Ordering code should be written after the code of capillary.
For example: WT1151DP4S22S2M1B01
1199RFW21A11A21-S
Covered Film of Remote Flange
F46 Cover F46 film to isolating diaphragm
Note: F46 only applicable to situation of positive pressure and remote flange filled with ordinary silicon oil;
Ordering code F46 only applicable to level transmitter, PFW-1 and PFW remote seal device;
F46 will be covered by user self while installing flange.
For example: WT1151DP4S22S2M1B01
1199PFW-1 11A-F46
Fig.26 Outline Dimension for WT2000TG Smart Directly Mounted Pressure Transmitter
Model and Ordering Code for WT2000TG Smart Directly Mounted Pressure Transmitter
Table 27
WT2000TG Smart Directly Mounted Pressure Transmitter
Code Measuring range kPa
4 0 0.935 37.4
5 0 4.67 186.8
6 0 17.24 690
7 0 51.7 2068
8 0 172.25 6890
9 0 517 20680
0 0 1034.2 35000
Code Output
S Smart 4-20mA DC in conformity with HART communication protocol
Code Connection type
A M20 1.5 male thread
B NPT1/2 male thread
C G1/2 male thread
D NPT1/2 female thread
E NPT1/4 female thread
Code Indicator
M3 LCD digital indicator
Code Installation bracket
B11 Bracket mounted on wall CS for range code 4 5 6 7
B12 Flat bracket mounted by pipe CS for range code 4 5 6 7
B13 Bracket mounted on wall SS for range code 4 5 6 7
B14 Flat bracket mounted by pipe SS for range code 4 5 6 7
B15 Flat bracket mounted by pipe CS for range code 8 9 0
B16 Bracket mounted on wall CS for range code 8 9 0
B17 Flat bracket mounted by pipe SS for range code 8 9 0
B18 Bracket mounted on wall SS for range code 8 9 0
Code Safe grade
d Flameproof Exd CT3 T6
i Intrinsical safe Exia CT3 T6
Code Cleaning
1 Degreasing on suface
Installation hole
133.5 (with
133.5 field indicator) 133.5 (with
133.5 field indicator)
Hoop Hoop
Installation
Installation
bracket
bracket
Installation bracket
Flat bracket mounted by 2 pipe Bracket mounted on wall
(Code B12/B14/B15/B17) (Code B11/B13/B16/B18)
1. NPT1/2 transitional connector 2. Nut M20 1.5 3. Sealing ring 4. 14 induced pressure tube
NPT1/2 Thread Transitional Induced Pressure Connector (Code C12)
1. Pressure chamber flange 2. M20 1.5 T-shaped male thread connector 3. Bolt 4. O ring
M20 1.5 T-shaped Male Thread Connection Block(Code C2)
1. Pressure chamber flange 2. Bolt 3. M20 1.5 T-shaped male thread connector 4. O ring; 5. Nut M20 1.5
6. 14 induced pressure tube
M20 1.5 Thread Connector (Code C21)
Evenly distributed
Fig.31 Customer's Process Connection Flange for 3'' Class 150 Flange(D Determined by Customer) (for Reference)
Evenly distributed
Fig.32 Customer's Process Connection Flange for 4'' Class 150 Flange (D Determined by Customer) (for Reference)
Mating flange D d
3 127 80
4 157 95
Fig.33 Sealing Gasket of Flange
The customer may select the material of the sealing gasket of flange at his own option
according to the characteristic of the measured medium. Our company recommends using such
material as asbestos rubber, buna, viton, nylon, or PTFE etc.