MORT&H Clause-
Identification of sources for Materials, 117,118 Refer
01 As per testing plan W R
selection, testing and getting approval HCC T 39 17 16
Section-900,1000
Concrete Design mix for each Grade Concrete Design Mix Once per each source of
03 MORT&H Clause-1704 W R
and Approval Report(s) material
Survey & Setting out for relevant Approved construction As per Survey
05 Before start of activity W R
structure to be concreted drawing Records
MORT&H Cls:
Every pour during
07 Concrete check list 1626, 1606, HCC F 40 17 10 W R
concreting
1500, 1713 to 1715
Page1
INSPECTION AND TEST PLAN
Project: LMNHP -EW II (WB-II); Package-4
Client: National Highways Authority of India
Engineer: RI & CEG JV.
Contractor: Hindustan Construction Co. Ltd.
Page2
INSPECTION AND TEST PLAN
Project: LMNHP -EW II (WB-II); Package-4
Client: National Highways Authority of India
Engineer: RI & CEG JV.
Contractor: Hindustan Construction Co. Ltd.
LEGEND: W: Witness; H: Hold Point; S: Surviellance Inspection; R: Review of Reports; MORT&H: Ministry of Surface Transport Specifications;
Format No: HCC T 40 17 15, Rev No: 00, Rev Date: 28.08.06
Page3
INSPECTION AND TEST PLAN Doc No. HCC T 37 17 34
Project : LMNHP-EW II (WB) -III Rev. No. 0
Client : National Highways Autthority of India
Date of Rev. 1/9/2005
Engineer : Lea Associates South Asia Pvt. Ltd.
Contractor : Hindustan Construction Co. Limited Page of 2
1. CEMENT
MTC/
M.O.R.T & H, Table:900-6
a Compressive Strength Once per each source/batch W/H R Receiving Inspection
IS:4031 (Part-6)
HCC F 39 14 65
MTC/
Consistency , Initial and Final Setting Time M.O.R.T & H, Table:900-6
b Once per each source/batch W/H R Receiving Inspection
test IS:4031 (Part-5)
HCC F 39 14 64
MTC/
M.O.R.T & H, Table:900-6
c Fineness test by dry sieving Once per each source/batch W/H R Receiving Inspection
IS:4031 (Part-1)
HCC F 39 14 62
MTC/
M.O.R.T & H, Table:900-6
d Soundness test Once per each source/batch W/H R Receiving Inspection
IS:4031 (Part-3)
HCC F 39 14 63
3. WATER
4. CONCRETE
HCC F 39 14 72
M.O.R.T & H, Table:900-6
a Workability of Fresh Concrete(Slump) One test per each batch W R In-Process
IS:1199
HCC F 39 14 75
M.O.R.T & H, Table:900-6
b Core strength on Hardened concrete External Lab Report As and when required H R Acceptance test
IS:516
5. CONCRETE ADMIXTURES
6. BENTONITE
Clause 115.2.3 of
a Gradation for Silt content HCC F 39 14 03 Once per Lot W R Screening test
M.O.R.T & H
Clause 115.2.3 of
b Liquid Limit HCC F 39 14 09 Once per Lot W R Screening test
M.O.R.T & H
LEGEND: W: Witness; H: Hold Point; S: Surviellance Inspection; R: Review of Reports; M.O.R.T & H: Ministry of Surface Transport Specifications;