GRmin = 22 ; GRmax = 81

GR leido −GR min


IPR= =0,0169
GR max−GR min
GRleido @ 1805 = 23
23−22
IPR= =0,0169=1.69 %
81−22
GRleido @ 1807 = 49
49−22
IPR= =0 , 4576=45,76 %
81−22
GRleido @ 1808 = 36
36−22
IPR= =0 , 2373=23,73 %
81−22
GRleido @ 18010,5 = 65
65−22
IPR= =0 , 7 28 8=72,88 %
81−22
SOMERO O NO CONSOLIDADAS

V CL=0,083 [ 2(3,7 X IPR )−1.0 ]

V CL=0,083 [ 2(3,7 X 0,0169 )−1.0 ] =0,00367=0,367 %

V CL=0,083 [ 2(3,7 X 0,4576 )−1.0 ] =0,18538=18,538 %

V CL=0,083 [ 2(3,7 X 0,2373 )−1.0 ] =0,06954=6,954 %

V CL=0,083 [ 2(3,7 X 0,7288 ) −1.0 ] =0,45505=45,505 %

ANTIGUAS O CONSOLIDADAS

V CL=0,33 [ 2( 2 XIPR )−1 ]

V CL=0 , 3 3 [ 2(2 X 0,0169 )−1.0 ]=0 , 00782=0,782 %

V CL=0 , 3 3 [ 2(2 X 0,4576 ) −1.0 ]=0 , 29232=29,232 %

V CL=0 , 3 3 [ 2(2 X 0,2373 )−1.0 ]=0 , 12854=12,854 %

V CL=0 , 3 3 [ 2(2 X 0,7288 )−1.0 ]=0 , 57635=57,635 %

A) hay dos arenas:


la primera arena: tope = 1803,3; base = 1806
la segunda arena: tope = 1807,2; base = 1810,3
B) espesor de la primera arena = 1806 – 1803,3 = 2,7
espesor de la segunda arena = 1810,3 – 1807,2 = 3,1

C) el espesor neto permeable = 2,7 + 3,1 = 5,8m


D) el net/gross del reservorio

Net A 1+ A 2 2,7+3 , 1
= = =0,8286
gross AT ( 1810 , 3−1803 , 3 )