Redesign Features:

The design of the LS RV is being changed to add a control pressure and that change should be detectable
screen at its inlet. This screen will help block small by the machine operator. The operator should then be
contaminate from getting stuck between the poppet instructed to check the screen and remove any
and seat. contaminate.

An extension was made to the cartridge, and a The high pressure o-ring of the new RV was increased
stainless steel screen (40 x 200 mesh, 75 micron in diameter from .375” to .438”. Accordingly, the
absolute) was wrapped around it and attached on both housing cavity diameter was increased to accept the
ends with solder; therefore, the screen is not new RV; therefore, a new RV will not fit into an old
replaceable. Screen surface area should be sufficient outlet. If an old RV is put into a new outlet, it
to prevent clogging with contaminate; however, if it will not build pressure.
should clog, the next highest RV in the system will

Parker Hannifin Corporation