Note: You must be at the Cold Start menu to use this feature.
In This Chapter
Tab Description
Licensing Enables you to transfer a license from a secure USB
drive (“dongle”) to Config600.
Notes:
Both the host PC and the S600+ must use the same
communications settings for data to transfer successfully.
If you are downloading a configuration via Ethernet, disable any
communication links from a device that is communicating with the
S600+ before attempting to download the configuration as this
may disrupt the confirmation upload/download.
Note: Both the S600+ and the host PC must have the same
communications settings to communicate successfully.
1. Start the Config Transfer utility.
2. Select the Transfer tab.
3. Enter the Modbus address for the S600+ in the S600 ID field.
This value is available from the S600+ front panel (select
Tech/Engineer > Communications > Assignment > Modbus
Address) or from the Network option on the Cold Start menu.
You can send up to 20 user configurations files to the S600+ from the
host PC:
Config – The main configuration file for the S600+ including all
the initialization values.
Displays – Configuration file for the display menus and data pages.
Reports – Report format configuration files.
Modbus Maps – Modbus configuration files, including slave
register maps and master polling sequences.
LogiCalcs – Custom-written files that allow creation of user-
defined functions.
Extras – User-defined look-up tables, configuration backup files,
and prover sequence files.
You can use Config Transfer to download the following files (image
files):
Binary Package – Embedded software for the FloBoss S600+; a
basic version is installed in the S600+ prior to delivery. To transfer
this package, copy the binary.app file into Binary folder from
Config S600+ directory.
Firmware – Software firmware and embedded software for the
FloBoss S600+. This is for internal Emerson use only.
Updating the binary or firmware file could affect the entire metering
Caution accuracy and stability of your S600+. It is strongly recommended that
you update this file only under the specific instruction of technical
support personnel.
Note: You must cold-start the S600+ before you can send a
configuration file.
1. Select System Settings > System Status > CHNG > Enter valid
operator code > Cold Start > Yes to cold-start the S600+ before
you send a configuration file
2. Launch Config Transfer.
3. Select the Send tab on the Config Transfer screen.
Note: If you are updating the firmware or binary file (under the
direction of technical support personnel), you must first place
the S600+ in Reflash Firmware mode. For further instructions,
refer to “Reflash Firmware” in Chapter 8, Troubleshooting, in
the FloBoss S600 Flow Manager Instruction Manual (A6115).
Note: Click Refresh List to update the list with the configuration
files in S600+.
2. Select the Enabled check box. This activates the Logging Detail
field.
3. Click to indicate the logging detail. Valid values are General
(include only events) and Detailed (include both events and
activity). The default is General.
Note: The S600+ maintains the log until you either close the
application or disable the logging process.
9.7 Licensing
Note: This utility requires you to install firmware binary 06.21.
5. Click OK to close the dialog. The License screen now shows the
license installed on the S600+. Note also that the quantity of
licenses on the USB has decreased by 1.