You are on page 1of 4

US units

Partially full pipe calculation tool

Liquid flow Q gpm 100


Pipe internal diameter d in 4
Pipe full ? Q/d2.5 3.125
Pipe partially full

x 1.13943428318836
H/D 0.778809101132588
Height of liquid in pipe H in 3.11523640453035

De/D 1.22706876119103
Equivalent diameter De in 4.90827504476414

If you spot a mistake or wish to suggest an improvement, please contact powder.process@protonmail.com

Copyright www.PowderProcess.net

The content of PowderProcess.net is copyrighted but no warranty nor liability is ensured. The content of this site is to be seen as a help and important information and ca
procedure of his organization or by checking another source. The user must always respect all applicable regulation. The use of the information is at

Page 1
US units

pipe calculation tool

owder.process@protonmail.com

is to be seen as a help and important information and calculation must always be double checked by the user through the quality
all applicable regulation. The use of the information is at the user and its organization own risk and own cost.

Page 2
SI units

Partially full pipe calculation tool

Liquid flow Q m3/h 23


Pipe internal diameter d mm 100
Pipe full ? Q/d2.5 3.28651763444227
Pipe partially full

x 1.18982853442816
H/D 0.792899585588656
Height of liquid in pipe H mm 79.2899585588656

De/D 1.22833594637487
Equivalent diameter De mm 122.833594637487

If you spot a mistake or wish to suggest an improvement, please contact powder.process@protonmail.com

Copyright www.PowderProcess.net

The content of PowderProcess.net is copyrighted but no warranty nor liability is ensured. The content of this site is to be seen as a help and important information and ca
procedure of his organization or by checking another source. The user must always respect all applicable regulation. The use of the information is at

Page 3
SI units

pipe calculation tool

101.269
3.94

3.124024367

4.839643629

owder.process@protonmail.com

is to be seen as a help and important information and calculation must always be double checked by the user through the quality
all applicable regulation. The use of the information is at the user and its organization own risk and own cost.

Page 4

You might also like