NLQ200-0468 Rev 1

Customer Item: Replacement ENA/122-50439 Date: 16/03/2023

Item: 10.0 Amount: 1


Kelvion Plate Heat Exchanger: NT100X BA-150
Thermal data for 1 unit(s) in parallel and 1 unit(s) in series
hot side cold side
Media: Lean Amine Rich Amine
Heat exchanged: 13631586 Btu/h
Mass flow: 178525 201902 lb/h
Volume flow: 359.1 385.1 US gpm / US
gpm
Temperature inlet: 245.20 124.90 °F
Temperature outlet: 158.00 208.00 °F
Pressure drop: 2.09 2.82 PSI
Working pressure inlet: 72.50 72.50 PSIg
Filling volume: 5.772 5.709 ft³
Product properties
Density: 61.9899 65.3650 lb/ft³
Heat capacity: 0.87623 0.81300 Btu/lb°F
Thermal conductivity: 0.21837 0.21150 Btu/fth°F
Dyn. viscosity inlet: 1.0589 5.6000 cP
Dyn. viscosity outlet: 3.5000 2.0000 cP

Unit Data
Plate Type: NT100X HV
Heat transfer area (total / per unit): 1317.50 1317.50 ft²
Number of plates (total / per unit): 182 182
Plate thickness: 0.6 mm
LMTD: 35.11 R
Surface margin: -4.78 %
Plate material: AISI316L
Gasket material / Gasket type: EPDM glueless
Internal flow (passes x channels): 1 x 91 1 x 90
No. of frames (par. / ser. / total): 1 1 1
Material pressure plates / surface: SA516GR60 painted RAL5002
CIP:

Design temperature: Min.: -20.00 / -20.00 Max.: 300.00 / °F


300.00
Design pressure: Min.: 0.00 / 0.00 Max.: 150.00 / PSIg
150.00
Test pressure*: 195.00 / 195.00 PSIg Design code: ASME Sect
VIII Div1 Ed.
2021
The connection types and positions are defined in the attached dimension sheet.

*Hydrostatic tests will be performed with Iiners installed, no pressure retaining welds will be leak tested
before Iiners are installed.

Remarks:
IESL Global – Replacement NT100X
Quotation Number: NLQ200-0468 rev 1 Date: 16 March 2023 Page 4 of 7
NLQ200-0468 Rev 1

Dimension Sheet Plate Heat Exchanger

Dimensions of drawing in [mm] 0100923.tiff


Type: NT100X BA-150

n: 68.110 in s1: 40 mm a-max frame: 33.819 in empty weight: 3082.94 lbs


k: 71.063 in s2: 40 mm a-max actual: 25.437 in max. total weight: 3810.16 lbs
l: 64.567 in h: 78.819 in max. bolt length: 41.338 in
Pos Size Type Media Side/Flow m
1F 4" Metal insert ANSI 150 AISI316L Lean Amine hot - in 0.039 in
2F 4" Metal insert ANSI 150 AISI316L Rich Amine cold - out 0.039 in
3F 4" Metal insert ANSI 150 AISI316L Rich Amine cold - in 0.039 in
4F 4" Metal insert ANSI 150 AISI316L Lean Amine hot - out 0.039 in

Metal insert
ANSI150
AISI316L
150lbs
1F;2F;3F;4F
Technical Revisions reserved. Layer thickness in case of painted frames acc. DIN EN ISO 12944-5, frame plate surface
quality acc. DIN EN 10029. The design details are valid for PHE manufactured by Kelvion PHE GmbH/Sarstedt.

IESL Global – Replacement NT100X


Quotation Number: NLQ200-0468 rev 1 Date: 16 March 2023 Page 5 of 7
NLQ200-0468 Rev 1
Customer Item: Technical Requirements Date: 16/03/2023

Item: 20.0 Amount: 1

The following Technical Requirements have been included in the offer:

Item
CALCULATIONS__Stress calculation acc. to ASME, Category temperature = -29°C
CALCULATIONS__Foundation loads and centre of gravity (stability calculation) base price plus
adder
CALCULATIONS__Snow loads acc. to specification (adder to foundation loads)
CALCULATIONS__Lifting lug calculation (adder to foundation loads)
SPECIALS__Lable bridge (standard: 1.4301, on request: 1.4571)
TESTS__Hardness test of metal insert material incl. report
TESTS__Hardness test of gasket incl. report
TESTS__Check of painting - Dry film thickness acc. to ISO 2808 incl. report
TESTS__Check of cleanliness - signature in ITP

IESL Global – Replacement NT100X


Quotation Number: NLQ200-0468 rev 1 Date: 16 March 2023 Page 6 of 7
NLQ200-0468 Rev 1

Customer Item: Documentation Requirements Date: 16/03/2023

Item: 20.1 Amount: 1

The following items have been included in the Documentation Requirements of the offer:

Info Approval Final Item


x x x PROJECT SCHEDULE__Kelvion PHE standard
x x x VDS / VDL / VDR__Kelvion PHE standard
x x x PROGRESS REPORT__Kelvion PHE standard
x x x SUBORDER LIST__Kelvion PHE standard
x x x CERTIFICATES__ASME
x x x CERTIFICATES__ATEX NA-certificate
CUSTOMER INSPECTION VISIT__Price per day (minimum one day to be calculated per
x / / visit)
x x x PROCEDURES__Surface protection for PHE frames (7.096-210)
x x x PROCEDURES__Pressure test (GPHE 7.096-747, WPHE 7.096-748, LWC 7.096-318)
x x x PROCEDURES__Packing of plate heat exchangers (7.096-211)
x x x WATER ANALYSIS__Circulation and potable water
x x x PACKING LIST__Final packing list - Kelvion PHE standard
x x x DRAWING__Customized form (base price plus adders)
x x x DRAWING__incl. room for maintenance (adder to customized drawing)
x x x DRAWING__incl. nozzle loads (adder to customized drawing)
x x x DRAWING__incl. foundation plan with loads (adder to customized drawing)
x x x DRAWING__incl. stud bolts (adder to customized drawing)
x x x DRAWING__Electronic format - pdf (adder to customized drawing)
/ / x DRAWING__As built-drawing (adder to customized drawing)
x x x THERMAL DATA SHEET__Kelvion PHE standard - English
x x x CERTIFICATES__Type approval
x / / CERTIFICATES__Material Certificates ONLY SPARE PARTS
x x x CALCULATIONS__According to Technical requirements
x x x NOZZLE LOADS__Data sheet Kelvion PHE standard (API 662 Table 1)
/ / x DOCUMENTATION__Printed documentation
x x x ITP__Kelvion PHE standard
QA-DOCUMENTS__Certificate of pressure test and final examination incl. material
/ / x certificates
/ / x TEST REPORTS__According to Technical requirements
/ / x INSPECTION_ASME U-Stamp GPHE (per unit, no quantity discount)

IESL Global – Replacement NT100X