You are on page 1of 3

2/23/2018

Project No. :-
Client : PT PERTAMINA (Persero)
Location : Balikpapan
HYDRAULIC CALCULATION SHEET By : AFF
Date : 22-2-2017
System : Drainage Pump Area 10 From : Open Pit To : Disposal Rev :4
Case : Drainage Pump Load : 100 %

Item Line No. Vapor Liquid Piping Information Equiv. Equiv. Head Velo- Mach Friction Loss Head Pressure
Flow Mol.w Comp. Temp. Kappa Dens. Visc. Flow Dens. Visc. Size Sch. ID Length  Ratio Length Diff. city No. /100 m Total Diff. In Out
[kg/h] [-] [-] [oC] [-] [kg/m3] [cp] [kg/h] [kg/m3] [cp] [inch] [-] [mm] [m] [] [-] [m] [m] [m/s] [-] [kg/cm ] [kg/cm ] [kg/cm ] [kg/cm2A]
2 2 2
[kg/cm2A]
Open Pit 1.034 1.034
Suction Line 12"-DW-070 0 450000 1000 0.797 12 S40 303.23 0.5 50 1.1 0.55 0.5 1.7309 0 0.0742 0.0004 0.05 1.034 1.084
Suction-strainer 0.3 1.084 0.784
Pump 1.51 0.784 2.289
Elbow 0 450000 1000 0.797 12 S40 303.23 6.71 50 1.1 7.381 -0.5 1.7309 0 0.0742 0.0055 -0.05 2.289 2.233
Discharge Line 12"-DW-071 0 450000 1000 0.797 12 S40 303.23 3.50 50 1.1 3.8467 -3.497 1.7309 0 0.0742 0.0029 -0.36 2.233 1.873
Elbow 0 450000 1000 0.797 12 S40 303.23 6.71 50 1 6.71 -0.5 1.7309 0 0.0742 0.005 -0.05 1.873 1.817
Discharge Line 12"-DW-072 0 450000 1000 0.797 12 S40 303.23 2.80 50 1.1 3.08 0 1.7309 0 0.0742 0.0023 0 1.817 1.815
Check Valve 0 450000 1000 0.797 12 S40 303.23 28.96 50 1 28.96 0 1.7309 0 0.0742 0.0215 0 1.815 1.794
Gate Valve 0 450000 1000 0.797 12 S40 303.23 2.74 50 1 2.74 0 1.7309 0 0.0742 0.002 0 1.794 1.792
Elbow 0 450000 1000 0.797 12 S40 303.23 6.71 50 1 6.71 0 1.7309 0 0.0742 0.005 0 1.792 1.787
Discharge Line 12"-DW-075 0 450000 1000 0.797 12 S40 303.23 2.15 50 1.1 2.3672 2.152 1.7309 0 0.0742 0.0018 0.22 1.787 2.004
Elbow 0 450000 1000 0.797 12 S40 303.23 6.71 50 1 6.71 0.5 1.7309 0 0.0742 0.005 0.05 2.004 2.050
Discharge Line 12"-DW-076 0 450000 1000 0.797 12 S40 303.23 5.57 50 1.1 6.1281 0 1.7309 0 0.0742 0.0045 0 2.050 2.046
Reducer 0 450000 1000 0.797 12 S40 303.23 7.32 50 1.1 8.052 0 1.7309 0 0.0742 0.006 0 2.046 2.040
Discharge Line 20"-DW-079 0 450000 1000 0.797 20 S40 477.83 31.00 50 1.1 34.1 0.371 0.6971 0 0.0077 0.0026 0.04 2.040 2.075
Disposal 2.075 2.075

Pump Design Data Flow Rate : : 450 [m3/h] Disch. Press : 2.2893 [Kg/cm2A]
Suct. Press. : : 0.7841 [Kg/cm2A] NPSHa : -2.494 [m]
Head : 15.052 [m] Diff. Press : : 1.5052 [Kg/cm2] 21.40895642 psi
Vap. Press : : 1.0335 [Kg/cm2A] LHP : : 18.456 [kW] 24.75044804 hp
LHP : : 3 [kW]

Sp. Gr 1 Liquid Level


Vap. Pressure 0.043 Kg/cm2A HLL 1.905 m
NPSHa 7.411 m LLL 1.455 m
Safety Factor 1.000 m SUCTION 0.5 m
Available NPSH 6.411 m
Max Suct Press 0.924 Kg/cm2A
Shut- Off Pressure 2.731 Kg/cm2A
Design Press (take) 3 Kg/cm2A
CONTRACTOR: CALCULATION SHEET
EQUIPMENT NAME Drainage Pump Area 10 SHEET No. 1 of 1
Tag No. G‐334‐902 A

CLIENT: REV. DATE DESCRIPTION MADE BY CHECKED BY APPROVED BY


4 22/2/18 RE‐IFC AFF HY ADW

TAG NO  G‐334‐902 A

SERVICE  Drainage Pump
OPERATION Intermittent
Number of Pump running : 1

OPERATING CONDITIONS DISCHARGE CONDITIONS Sch  S40


1. Fluid Name : Water 1. Pipe :  Line Size 12.00 (inch) 
o
2. Temp. Norm.  30 ( C)  ID 303.23 (mm) 
3. Density Norm. 1000 (kg/m3)  Length 14.02 (m) 
4. Vap. Pres. Max.  1.03 (kg/cm2a)  2. Pipe :  Line Size 20.00 (inch) 
5. Vap. Pres. Norm.  0.043 (kg/cm2a)  ID 477.83 (mm) 
6. Viscosity Norm. 0.797 (cP)  Length 31.00 (m) 
3
7. Capacity Normal 450 (m /h)  3. Press.Loss
8. Capacity per pump 450.0 (m3/h)     a. Line+Fittings 0.06 (kg/cm2a) 
9. Capacity Overdesign  0 (%)      b. Filter ‐ (kg/cm2a) 
10. Capacity Design  495 (m3/h)     c. Orifice ‐ (kg/cm2a) 
(Based on selected model pump)       d. Misc. ‐ (kg/cm2a) 
    f. Sub total (a‐e) 0.06 (kg/cm2a) 
SUCTION CONDITIONS Sch  S40 4. Control Valve ‐ (kg/cm2a) 
1. Pipe :  Line Size 12.00 (inch)  5. Max.Desti.Press  2.08 (kg/cm2a) 
ID 303.23 (mm)  6. Elevation  1.35 (m) 
2
Length 0.50 (m)  7. Disch.Press 2.289 (kg/cm a) 
2. Pipe :  Line Size 0.00 (inch) 
ID 0.00 (mm) 
Length 0.00 (m) 
3. Min. Static Head 0.96 (m) 
2
0.09 (kg/cm a)  HYDRAULIC POWER  = 18.458 kW
    Max. Static Head ‐ (m)  24.752 HP (British)
2
‐ (kg/cm a)  28.465 HP (British) (Note 5)
4. Line Loss 0.0004 (kg/cm2a) 
5. Strainer Loss 0.3 (kg/cm2a) 
6. Other Loss  0.00 (kg/cm2a)  NET POSITIVE SUCTION HEAD
7. Suc. Press. (max) 0.92 (kg/cm2a)  1. Suc. Pressure (max) 0.92 (kg/cm2a) 
8. Suc. Press. (min) 0.78 (kg/cm2a)  2. Suc. Pressure (min) 0.78 (kg/cm2a) 
3. Vap. Pressure  0.043 (kg/cm2a) 
DIFFERENTIAL PRESSURE 4. NPSH Avail. (min) 6.41 (m)  (Note 2)

2
1. Disch.Pressure 2.29 (kg/cm a)  (Note 3)
2. Suc. Pressure (max) 0.92 (kg/cm2a)  (Note 3)
3. Suc. Pressure (min) 0.78 (kg/cm2a)  (Note 3)
4. Special Margin 0.00 % (Note 4)
2
5. Diff. Pressure 1.51 (kg/cm a)  (Note 1)
6. Head  15.05 (m) 

Notes :
1. Differential pressure is based on minimum suction pressure.
2. NPSHa minimum is based on minimum liquid level. 
3. Pressure drop suction and discharge are estimated based on 1 pump capacity.
4. 0 % design margin added for pump differential head.
5. Based on company specification 
     < 22 kW, 25% margin added
     < 55 kW, 15% margin added
     > 55 kW, 10% margin added.
PUMP ROUTE SKETCH

Drainage VS4 Pump


G-334-902 A

3800 mm
+5052 mm
602 mm
2152 mm
+4250 mm 200 mm

Discharge Line Discharge Line
12 inch 20 inch

Discharge Line 5571 mm 31000 mm


12 inch

3650 mm
Low Low Level

+2055 mm 1455 mm
500 mm

+600 mm
sump
(water)