You are on page 1of 12

SP-HA2937-32

High-power Fiber Amplifier

Operation Manual
Content

Safety Application Notes ......................................................................................................................... 2


1. Product introduction............................................................................................................................. 3
1.1 Overview........................................................................................................................................................................ 3

1.2 Features ......................................................................................................................................................................... 3

1.3 Application ..................................................................................................................................................................... 4

2. Block diagram.......................................................................................................................................... 4
3. Performance parameters .................................................................................................................... 4
4. Operation instruction............................................................................................................................ 5
4.1 Power.............................................................................................................................................................................. 5

4.2 Panel instruction .......................................................................................................................................................... 5

4.3 Indicator light ............................................................................................................................................................. 6

4.4 Display menu instruction ........................................................................................................................................... 7

Table 1: Laser parameter content explanation.......................................................................................................... 7

5. Network management application introduction ........................................................................ 9


5.1 WEB browser access ................................................................................................................................................ 9

6. Packing list.............................................................................................................................................. 11

-1-
Important notes for high power optical amplifier application

Safety Application Notes


Please read the following notes carefully before installation and application. Our
company is not responsible for the loss which is against following safety points.

The output of the laser and fiber optical amplifier is high power invisible laser
radiation, when the equipment is under operation, it is not permitted to
observe its connector head face to avoid of hurting eyes and skin.

The equipment interior contains precision optical device, to avoid serious


impact of damage, violent vibration and impact are not permitted. The fiber
tail is easily broken, please operate carefully.

The equipment interior contains electrostatic sensitive devices, please


operate carefully and make sure it's grounded well, and power is normal.

It is not permitted to disassemble the module, otherwise, it may cause


irreversible damage. Please contact us if any questions.

I Optical output head face protection: Optical output head face is easily to damage
due to high power optical source output. The following operations can easily cause
damage on head face.
1. To make sure the output pigtail head face is clean, especially if the output head face is
not clean, it is easy to burn output pigtail and causes output power become low in output
bigger power.
2. It is not permitted to clean pigtail or fiber jumper which links to the pigtail when there is
optical output, otherwise, it can easily burn output pigtail and causes output power become
low.
3. It is forbidden to insert or extract fiber-optical connector on optical source port when there
is optical output, or, it can burn fiber-optical connector.
4. To make sure the equipment runs steadily, optical output of <10mW may exist even if
the laser is under OFF condition, if you need to check fiber-optical head face with eyes or

-2-
microscope, please turn off the power switch.
II Electricity Impact Protection
This is the equipment with high power and high current, please link the input and output
wire jumper in good condition, and make sure turning on the power when input power is on.
Otherwise, it may damage the equipment.
III ESD Protection
Internal laser and some chips are static sensitive devices, when human body or other
object with high static touches to the equipment, especially the exposed connector, it can
easily cause irreversible damage to the equipment. So, it is suggested to make sure the
equipment is well grounded, and request the operators to take appropriate antistatic
protection.
IV Power Application
Please make sure the input power is within the scope of standard voltage and current, and
it is not permitted to turn off the power before turn off the equipment under operation.
IV Power Application
Please make sure the input power is within the scope of standard voltage and current, and
it is not permitted to turn off the power before turn off the equipment under operation.
V Personal Safety
It is strictly forbidden to observe the fiber-optical output headface when the optical source
with electricity, no matter the optical source output port or outer link wire jumper port, it is
not permitted to expose skin under strong sunshine, otherwise, it can cause serious
damage on body.
This equipment is IV level laser product, it can results in fire disaster or damage on object
when output optical directs to object. Please make sure to use it carefully.
1. Product introduction
1.1 Overview
SP-HA2937-32 is provided amplification product combined with CATV video business and
broadband business for operator.
This product is mainly used to amplify CATV signal and then combine with GPON signal.
1.2 Features
● 2U, 19″ standard case, easy installation.
● Low noise figure: lower than 6dB when 0dBm input.
● 8, 16, 32 multiple output ports optional.
● Adjust output level: output optical power adjustable range (downward 3dB).
● 1310nm, 1490nm, 1550nm WDM(Optional)can be integrated.
-3-
● Built-in network management responder complying with SNMP protocol, which can
achieve remote monitor for the equipment.
● Heat-dissipation fan adopts push-pull type structure, field replaceable.

1.3 Application
● Digital, analog CATV transmission system
● FTTH optical access system
● Optical power distribution system

2. Block diagram

3. Performance parameters
Items Units Technical parameters
Operating band broad nm 1545~1563
Input optical power range dBm -5~+10
Output ports quantity -- 32
Each port output power dBm 19
Output port optical power
dB 1.0
difference
Output power stability dB ≤±0.2
Noise figure(Note1) dB ≤6.0
Insertion loss (IP wavelength) dB ≤1.0 @ 1310 & 1490 nm

-4-
Return loss dB ≥45
Pump leakage Input port dBm ≤-30
power Output port dBm ≤-30
Polarization dependent gain dB ≤0.5
Polarization mode dispersion Ps/nm ≤0.5
CATV input -- SC/APC
Optical
Output -- LC/APC
connector type
PON input -- LC/UPC
Power voltage V AC110~265(50~60Hz)or DC48V
Power consumption W ≤65
Operating temperature range -5~+65
Max. operating relative
% Max. 85% no condensation
humidity
Storage temperature range -40~+80
Size mm 483×262×89.5
Packing size mm 570×410×190
Net weight Kg 5.20
Gross weight Kg 6.60
Note1: Input optical power is 0dBm testing value.

4. Operation instruction
4.1 Power
Please check input power voltage is the equipment rated input voltage before opening
equipment, grounded in good condition. Support three kinds of power supply, double
AC220V, double DC48V and AC220+DC48 combined.

4.2 Panel instruction


Front panel:

-5-
1、 Power module1
2、 Power module2
3、 Display window: to display equipment operating parameter, details please refer to 4.4
4、 Telecommunication interface
5、 Buttons:
■: setting and modifier key, to be used in modifying equipment parameters.
▼: page-down key, pressing this key to check the amplifier each parameter in turn from
top to bottom, and lower data in changing equipment parameter.
▲: page-up key, pressing this key to check the amplifier each parameter in turn from
bottom to top, and raise data in changing equipment parameter.
6、 Status indicator light: details please refer to 4.3.
7、 Laser on-off.
8、 1550nm CATV optical signal input port(both inputs is optional, single input to use)
9、 OLT PON module interface
10、Optical signal output port
11、Heat-dissipation fan
4.3 Indicator light
● POWER1:Power module 1 operating indicator light, which is green in operation and off
in not work.
● POWER2:Power module 2 operating indicator light, which is green in operation and off
in not work.
● INPUT: Input optical signal status indicator light. It’s green when input optical
power >-7dBm, and red when input optical power ≤-7dBm.
● OUTPUT:Output optical signal status indicator light. It’s green when each port output
power ≥+1.5dBm, and red when each port output power <+1.5dBm.

-6-
4.4 Display menu instruction
Item Display screen Content explanation
Model 1
1 MODEL
SP-HA2937-32
Pump Switch Status: 2
2 Pump laser status
ON
Input Power: 0.3dBm Input optic power
3
Each Output: 19.0dBm Optic power of each output
Total Power:
Total output power
4 37.0dBm
Current temperature
Module Temp: 34.8
Selection on fan working mode: AUTO when the equipment
Fan Working Mode 5 temperature more than 48 , the fan starts to work. If
5
AUTO SET■ temperature less than 44 , fan stop working. Press“■” for
on-off switch.
Three fans’ working status: STOP when fan is in OFF
Fan1: Fan2: Fan3:
6 mode; RUN when fan is in ON mode; FAULT when fan is in
STOP STOP STOP
trouble.
Total output power settings : press“■” enter into setting
Output Power Set 7
7 status, press“▲、▼”for data revision, after revision finished,
37.0dBm Adjust ■
press“■” to exit.
Laser Parameter 8 Laser working data,press “■” enter into its submenu,details
8
Select ■ refer to table 1.
Power Parameter 9 Power supply working data, press “■” enter into its
9
Select ■ submenu, details refer to table 2.
Network Config. 10 Network configuration, press “■” enter into its submenu,
10
Select ■ details refer to table 5.
Device Info. 11 Equipment information, press “■” enter into its submenu,
11
Select ■ details refer to table 6.

Table 1: Laser parameter content explanation


Item Display screen Content explanation
LD1 Current: 8.1
1 Laser 1 operating current
380 mA
LD1 Chip Temper 8.2
2 Laser 1 operating temperature
24.2
LD2 Current: 8.3
3 Laser 2 operating current
8.16A
LD3 Current: 8.4
4 Laser 3 operating current
8.16A
Return Main Menu 8.5
5 Press “■” key and exit
Select ■

Table 2: Power parameters content explanation


Item Display screen Content explanation
1 DC+12V_1 9.1 Power module 1 DC output voltage
-7-
+12.0V
DC+12V_2 9.2
2 Power module 2 DC output voltage
+12.1V
Return Main Menu 9.3
3 Press “■” key and exit
Select ■

Table3: Network configuration content explanation


Item Display screen Content explanation
Equipment IP address settings: Press “■” key and
IP Address 10.1 get into setting state, then press“▲、▼”key to
1
192.168.001.222 ■
change parameters, press “■”key to exit after
setting.
Equipment subnet mask settings: Press “■” key
Subnet Address 10.2 and get into setting state, then press“▲、▼”key to
2
255.255.255.000 ■
change parameters, press “■”key to exit after
setting.
Equipment gateway address settings: Press “■”
Gateway Address 10.3 key and get into setting state, then press“▲、▼”key
3
192.168.001.001 ■
to change parameters, press “■”key to exit after
setting.
Equipment Trap 1 address settings: Press “■” key
Trap IP_1 address 10.4 and get into setting state, then press“▲、▼”key to
4
192.168.001.010 ■
change parameters, press “■”key to exit after
setting.
Equipment Trap 2 address settings: Press “■” key
Trap IP_2 address 10.5 and get into setting state, then press“▲、▼”key to
5
192.168.001.100 ■
change parameters, press “■”key to exit after
setting.
Return Main Menu 10.6
6 Press “■” key to exit.
Select ■

Table 4: Equipment information explanation


Item Display screen Content explanation
S/N 11.1
1 Equipment serial No.
XXXXXXXXXXXX
Hardware Ver. 11.2
2 Equipment hardware version
V5.1
Software Ver. 11.3
3 Equipment software version
V5.0
Return Main Menu 11.4
4 Press “■” key to exit.
Select ■

-8-
5. Network management application introduction
The equipment inside is configured with status monitoring transponder, which is accessible
WEB browser, also support dedicated access to network management system, just by
connecting RJ45 interface in back panel of equipment to LAN. Then connect to master
server via LAN, equipment operation condition can be monitored real-timely via serve and
WEB browser or network management system.
5.1 WEB browser access
Enter equipment IP address in WEB browser(factory default IP is 192.168.1.222, which
can be viewed in showing interface). Enter the login in screen as shown below:

Enter the factory default user name “admin” and default password “123456”, you can login
to WEB administration interface.

At main interface, click and enter network address management interface,


which displays the network address parameters of the equipment. You can also modify
equipment IP address over this management interface.
-9-
At main interface, click and enter login password management interface, where
you can change your WEB login password.

At main interface, click and enter optical amplifier parameters


management interface, where you can check the operation parameters of the optic
amplifier, and also adjust the output optical power in this interface.

- 10 -
6. Packing list
1. Optical amplifier, 1 piece.
2. Power cord, provided according to AC power module quantity.
3. Operation manual, 1 copy.

- 11 -

You might also like