You are on page 1of 3

Distributed Power Unit

DPU40D-N06A3 Datasheet

Introduction

Distributed Power Unit (DPU) is a new generation power solution that


specialized for compact site. It supports pole-mounted and wall-
mounted. DPS can be widely used for macro site, small cell and remote
RRU.

Features

 Simple Deployment
DPU40D-N06A3 (Draft)
• Fast installation, 1 hour by 1 person (including power and backup
battery)

• Multiple input modes: AC/HVDC

 Easy O&M

• NetEco APP

• Fan-free design, 4-6 years routine maintenance-free

 Reliable Power Supply

• Can be used together with lithium iron battery for energy backup,
IP65, working temperature -40℃ to +55℃

Scenarios
 RRU/AAU remote site

 Easy Macro Site

 LampSite

 AtomCell (hot-spot / blind-spot coverage)

 Enterprise telecom scenario


Specifications
Distributed Power Unit for DC Load Scenarios
Product Type DPU40D-N06A3

Dimension (W×D×H) 300 mm × 60 mm × 400 mm

Weight ≤7.5 kg

Installation Mode Wall-mounted, pole-mounted, tower installation

Rated Power 2000 W

Parallel Number 4

Cabling Mode Bottom inlet and outlet


System
Protection Level IP65

Working Temperature −40℃ to +55℃ (without solar radiation)

Cooling Mode Natural heat dissipation

Operating Environment Class C*

Grid Environment 1st/ 2nd/ 3rd rate grid*

Storage Temperature −40℃ to +70℃

Environment Operating Humidity 5% to 95% (non-condensing)

-60 to 4000 m (From 2000~4000m, each 200m increases in altitude will decrease the
Altitude
working temperature by 1℃)

220 V AC single-phase
Power Input Mode 110 V AC dual-live wire
HVDC

AC: 85 - 300 V AC
Input Voltage
HVDC: 90 - 400 V DC
Power Input
Input Frequency 45 Hz - 65 Hz

AC Input 1× 16 A

AC SPD 20 kA/20 kA, 8/20 µs

Output Power 2000 W

Output Voltage -54.5V DC

Load Output DC Output 3×40 A Quick plug terminals with replaceable fuse

Battery Branch 1x40 A Quick plug terminals

DC SPD 10 kA/20 kA, 8/20 µs

Efficiency Maximum efficiency ≥96%

South (DB9+DB15): 2 × CAN


Communication
Interface Definition North (DB15):1 × RS485* (4 line)
Interface Dry contact (DB15): 4
*Remark:
RS485 interface supports telecom protocol / NetEco / U2000/M2000
Internal Communication: DPU supports in-band communication with 5th generation Huawei RRU.

Grid classification standard:


1st rate grid: power outage < 10hrs per month; 2nd rate grid: power outage < 10hrs per week; 3rd rate grid: power outage 2-8hrs per day

.
Operating environment definitions:
Class C-Sea environments or outdoor land environments (with simple shielding measures) near pollution sources. If a site is near a pollution
source, it is at most 3.7 km away from salt water such as the sea and salt lakes, 3 km away from heavy pollution sources such as smelteries,
coal mines, and thermal power plants, 2 km away from medium pollution sources such as chemical, rubber, and galvanization industries, or 1
km away from light pollution sources such as packing houses, tanneries, and boiler rooms.
Class D-Environments within 500 m away from the seashore. Class D environments are special Class C environments

Copyright © Huawei Technologies Co., Ltd. 2019. All rights reserved. HUAWEI TECHNOLOGIES CO., LTD.
No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Huawei Industrial Base
Ltd.
Bantian Longgang
General Disclaimer
Shenzhen 518129, P.R. China
The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and
operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to Tel: +86-755-28780808
differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only
and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice. www.huawei.com

You might also like