You are on page 1of 44

Our Vission

To be the best forerunner distributor for centrifugal water pumps, electric motors, industrial
diesel engine and
various tanks in Indonesia.
Indonesia

Our Mission
To distribute high quality products with competitive price and good services to our customers

Market Coverage Area


* Comercial
C i l Building
B ildi
* Industrial
* Oil & Gas
* Residential
* Municipal
* And any other sector that might need water pumps…
INTERNATIONAL STANDART ASSOCIATION
* ARPENA Member No. 011721 – 01092
NFPA-20 – National Fire Protection Association - code 20 * ARKAINDO the association of indonesian water works contractors.
No 09.3175.1027
No. 09 3175 1027
LPCB – Loss Prevention Certification Board (Formerly
known as LPC/FOC – Fire Officers Committee)
Manufacture Location

* Aurora – N. Aurora IIIinois U.S.A.


Li ti A
Listing i (FM/UL)
Agencies • Dedicated surface pump, mostly on horizontal pump
FM: Factory Mutual

- Private insurance company


- I’ts function is dedicated to Loss
prevention

UL: Underwriters Laboratories Inc.


-Non-profit organization
-Dedicated to the protection of life and property
* Layne Vertiline – Kansas City, Kansas U.S.A.
• Dedicated for vetical turbine, Axial pump

VENDOR LIST AURORA PUMP


• Pertamina, No. 383 / F00230 / 2009 - SO
• Pertamina, No. 422 / F30200 / 2010 – SO
•SKT Pertamina with Vendor number 136125
* Hydromatic & myers – ashland, OH.
Agency Letter from AURORA PENTAIR PUMP GROUP • Dedicated for submersible sewage pump

DEPERINDAG
Certificate of registration as a distributor of goods produced abroad
No. 3712 / STP-LN / UPP / 6 / 2016 until 25 April 2017
SIUP No. 1397 / 24.1.0 / 31.72 / 05 / 1.824.271 / 2015
NPWP No. 01.321.560.3 – 048.000
SBU No. 1-0905-000-0062287
Roda Nurmala Performance in Indonesia 2001 - Desember 2012 Industri: Oil & Gas:
•Holcim Indonesia • Total Indonesia
(based on number of project) • Semen Padang • Batu Hijau WTP 1
35
• Semen Cibinong • Batu Hijau WTP 2
30 • Semen Bosowa Sulawesi • PLTU Muara Karangg
• Pupuk Kujang • Depo Pertamina Bojonegoro
25 • Pupuk Sriwijaya • Pertamina Sagata Kalimantan
20 Fire • Toyota Astra Motor • Freeport
HVAC • AHM Cibitung • Medco Energi Soka
15 Plumbing • GS Battry • Medco M2 Tarakan
• Eternit Gresik • Pertamina Balongan
10 Submersible
• Bayer Jkt, Sby, Medan
B Jkt Sb M d • Pertamina
P t i Cikampek
Cik k
• Jhonson & Jhonson Factory • Pertamina UPMS IV Semarang
5
• Susu Cair Indomilk • CNOOC
0 • Nestle Pasuruan • Medco Energi Kaji
2001 2003 2005 2007 2009 2011 2013 • Wilmar Nabati • Medco Energi Serdang
• Flour Mill Factory • Pertamina Makasar
• Pabrik Sugizindo • Pertamina Aceh EP Rantau
Aceh EP Rantau
PROJECT SUMMARY • San Miguel • Pertamina EP Sum. Prabumulih
• PDM Medan • DPPU Soekarno Hatta
Comercial Building • SUJ Indochem Cilegon • Pertamina Depot Badas
•Grand Indonesia •Sudirman Park • Armada Jhonson Control • Pertamina EP Rantau
• Gandaria city • Sudirman Tower • Pabrik Rokok Gudang Garam • Pertamina Depot Sorong
• Central Park • St. Regis Bali • Gedung Auditorium PT. AHM • Pertamina LPG Tanjung Perak
• Season City • Equity Tower • APM Armada Auto Parts • Pertamina EP Pendopo
• Pondok Indah Mall 2 • city Tower • SRC Factory Karawang • Pertamina Makasar
• Jakarta city Center (JACC) • Cyber Building 2 • PT. TEMPO • Pertamina Depot Semampir
• Water Place Surabaya • Cyber 3 ( Data Center ) • OTTO PHARMACEUTIAL • Pertamina LPG Tanjung Priok
• Plaza Asia Tasikmalaya • WTC mangga Dua • Sugar Refinery Marunda • Pertamina DPPU Kupang
• Pasar Baru Sqr Balikpapan  • Nikko Hotel • SUJ Cilegon • Pertamina UBEB Tanjung
• Bekasi Squere • The East
The East • Indofood New Factory Cikupa
Indofood New Factory Cikupa • Pertamina EP Cepu
EP Cepu
• Mega Glodok Kemayoran • XL Bintaro • DSO Djarum Tandes Surabaya • Pertamina Jayapura
• Paragon City Semarang • Indosat Sukabumi • MEDCO M12 – Tarakan
• Carefour Kiara condong • BPK Penabur Kelapa Gading • Pertamina Pertagas Sumatera
•Carefour Rungkut Surabaya • Universitas Pelita Harapan • Pertamina Depot Tasikmalaya
• Carefur Cibinong • Binus Boarding House • Pertamina Depot Gorontalo
• Tempo Scan Tower • Universitas Mercu Buana • Pertamina Bitung
• Apartemen Golf Pondok Indah 3 • IPEKA International School • Pertamina Depot Padalarang
• Wisma Pondok Indah 2 • Bank Harda • CNG Sei Gelam
• City Home Kelapa Gading • BNI 46 Lada • Pertamina Biak
• Frenchwalk Kelapa Gading • Bandara Lombok • Pertamina Semarang
• Adhiwangsa Rcidence • Bandara Kualanamu Medan • Pertamina Rewulu
• Belagio Residence • Islamic Center Tj. Priok •Petamina Balikpapan
Horizontal Split Case Horozontal Split case Horizontal Multi Stage Vertical Turbine
• Single Stage Double Suction Split       •UL listed / FM Approve / NFPA‐20 Design • Stainless Steel Centrifugal  • UL listed / FM Approve / NFPA‐
Case •Flow from 250 to 5000 US GPM Pump 20 Design
• Water Work, irigation and                        • Pressures from 40 to 490 PSI • Cooling Water System •Flow from 250 to 4500 US GPM
Drainage • For Comercial and Industrial Use • Domestic Water Supply • Pressures from 75 to 387 PSI
• Pumping Station, power Station,  
Pumping Station power Station Diesel and Electric Driven
•Diesel and Electric Driven • Industrial Cleaning
Industrial Cleaning • For Comercial, Industrial and 
For Comercial Industrial and
Industrial Water Supply System, • Agriculture Marine Use
Fire Fighting Application in  Diesel Engine • Pesticide Dosing System • Special Material for Seawater  
refinering. •UL listed / FM Approve / NFPA‐20 Design • Environmental Protection Application
•Materials : •Engine are Selected for the Coustemer's • Water Treatment • Diesel and Electric Driven
Casing   – Cast Iron Needs • Boosting & Circulation 
– Ductile Cast Iron  •Fuel Tank and Other Accessories are  System
y
Impeller    – Cast Iron Avaliable
– Bronze •For Comercial, Industrial and Marine Use
– Stainless Steel Vertical Multistage
Shaft    – C. Steel •Minicipal Water Supply & Pressure
– Cr Steel Boosting
Casing Wear Rings  – Cast iron •Domestic Water Supply
– Bronze  • Boiler Feed & Condensate System
il d&C d S
– Brass  • Cooling Water System
• irigation & dewatering
• Jockey Fire Fighting
• Washing Plant & Washdown
Packaged Fire Pump System Vertical Inline Multy-Stage Centrifugal Pump End Suction
• UL Listed/FM approved • Automatic casing air release • UL Listed/FM •Water Supply & Booster , Boiler •Air Conditioning
Aurora fire pump valve Approved/NFPA-20 Design Feed & Condensate Pump •Heating & Ventilating
• UL Listed/FM approved fire • Casing pressure relief valve • Flows from 50 to 750 GPM •Industrial Process, High Pressure • Refrigeration
pump controller (electric packages) • Pressures from 40 to 205 PSI • Cleaning Car Wishing • Fire Protection
• ETL Listed packaged fire • Hose header with valves, caps • For Commercial, Residential • Draining Water in Mines • Plumbing & Central Industry
pump system & chains and Industrial Use • Fire Fighting • Food & Drink Manufacture
• Aurora jockey pump • Suction and discharge piping • Space Saving Design • Marine Engineering • Circulating
• UL Listed jockey pump per NFPA 20 • As Turbine for Energy Recovery • Water Pressure Boosting
controller • All electrical components pre- • Chemical, Petrochemical • Transfer & Factory Pumping
• Pressure sensing lines wired at factory Engineering • Water Treatment & Supply
complete per NFPA 20 • Complete system • Irigation & Drainage
• Listed OS & Y gate & butterfly hydrostatically tested • Petrolium Products
valves
• Suction and discharge
pressure gauges
• Automatic casing air release
valve
• Casing pressure relief valve
(electric packages)
• Hose header with valves, caps
& chains
• Suction and discharge piping
per NFPA 20
Head Office
Komp. Perkantoran Royal Sunter Jl. Danau Sunter Selatan Blok F No. 16 – 17
Telp. (+62-21) 651 5689 (Hunting) Fax. (+62-21) 650 9935, 651 3664
Jakarta 14350 – Indonesia
E-mail : Rodanurmala@rodanurmala.com

Workshop
Kawasan Pergudangan BizPark Blok A-5 No. 11
Jl. Raya Bekasi Km. 21.5 Pulo Gadung, Jakarta Timur, Indinesia
Telp. (+62-21) 4683 0701 (Hunting) Fax. (+62-21) 4683 7153
MARINE , OIL AND GAS PUMPING SOLUTIONS

www.aurorapump.com
You have the operation...
We provide the equipment solutions to meet your marine, oil and gas pumping
applications.

• Thruster pumps
• Ballast pumps
• Potable water pumps
• Fire water pumps
• Bilge Pumps
• Fuel oil pumps
• Drill water pumps
• Lube oil pumps
• Foam pumps
• Soluble oil transfer pumps
• Jockey pumps
• Base oil transfer pumps

Aurora Pump provides various pumping solutions for offshore, marine, oil and gas applications. Through
manufacturing and design, our pumps provide innovative pumping solutions to meet various workboat and
offshore rigging needs.

There is a high demand to fulfill energy needs through offshore exploration and drilling in the world today,
Aurora Pump is providing quality pump solutions that meet the needs of this ever-expanding market.

Our commitment to excellence goes beyond our product line. Aurora Pump is dedicated to keeping our
customers, distributors and employees educated and updated on the leading developments in the market
and with technology. Saving valuable time, our computer software and web tools assist with the selection
of the best pumps and systems to meet various application needs.

As an ISO 9001 registered company, we are committed to quality. You can rely on Aurora Pump products
and qualified distribution networks to provide total fluid flow solutions.
Fire Protection Pumps
Aurora Pump offers a complete line of pumps to
meet your fire protection needs: Vertical Inline, Hor-
izontal Split-case, Vertical Split-case, Vertical Tur-
bine, Foam and Mist pumps. Aurora PumpTM,
Fairbanks MorseTM, and EdwardsTM are the product
lines that are manufactured and sold at the North
Aurora Operations plant. Offering both electric and
diesel drives, we can also supply complete pack-
aged systems to custom fit your requirements. All
fire pumps and packages are built to NFPA 20 and
NEC standards with UL Listed/FM approved com-
ponents.

Single Stage Vertical Inline Pumps


Vertical inline close-coupled pumps are specifically
designed for mounting in any position directly in a
Regardless if your opera- pipeline. The suction and discharge nozzles are lo-
tion is deep water, fixed plat- cated on the same centerline, 180 degrees apart.
Vertical inline pumps significantly reduce the space
form, floating production, required, are easy to maintain, and minimize pump-
ing noise. The Aurora Pump 380 series pumps are
semi-submersible,
offered in bronze fitted construction or all iron con-
work/crew boats, naval, or struction with bronze or 316 stainless steel shaft
sleeves. Capacities up to 4500 GPM; heads to 370
any other type, we will pro- feet; and a 175-PSI case working pressure.
vide you with a solution to
Split Case pump solutions
all your pumping application Aurora Pump split case pumps are ideal in the han-
needs. dling of liquids where the need for the utmost relia-
bility and accessibility is paramount. Offered in both
horizontal and vertical configurations, the Aurora
Pump 410 split case series provides you with vari-
ous options to meet your application needs. Offered
in all iron all bronze or special alloy construction.
Capacities up to 15000 GPM; heads up to 500 feet;
and up to 250-PSI working pressure.

Edwards High Performance Rotary Gear pumps


Edwards foam and water mist pumps provide fire
protection applicable for your offshore needs. For
more than 80 years, these pumps have been a pre-
ferred choice in many such applications. Edwards
foam and water mist pumps are offered in Ductile
Iron Bronze or Stainless Steel. Flows from 4 GPM
to 500 GPM and operate up to 1800 RPM without
gear reduction.

ST ER E D Q U
EGI
ALI
R
ISO 9001

TY SYSTEM

R
FM
Aurora Pump is a global manufacturer of pumps and systems for the commercial, municipal, industrial,
marine, oil and gas, and fire protection markets. We provide the solutions to meet your pumping needs.
With over eighty years of experience, Aurora Pump is a leading pump and system supplier devoted to
designing and manufacturing a wide variety of pumps and systems used in an ever expanding variety of
markets and applications throughout the world.

For more information contact your local Aurora Pump Distributor.


To find a local distributor, visit www.aurorapump.com to access our Distributor Locator.

800 AIRPORT ROAD • NORTH AURORA • IL • 60542 • U.S.A. | PH: 630.859.7000 | AURORA_INFO@PENTAIRWATER.COM
WWW.AURORAPUMP.COM
Packaged Fire Pump Systems
At the heart of our systems you’ll find the
Aurora pumps you’ve relied on for over 80 years.
aurora offers custom and pre-engineered packaged fire pump
systems. these systems are factory assembled and tested, leav-
ing only pipe connections, power connections and structural base
grouting to be completed on site. all fire pump packages built to
nFpa 20 & neC standards with ul listed/FM approved components.

Fire puMp paCkageS Standard equipMent


n UL listed/FM approved Aurora fire pump n Automatic casing air release valve

n UL listed/FM approved fire pump controller n Casing pressure relief valve (electric packages)

n Aurora jockey pump n Hose header with valves, caps & chains

n UL listed jockey pump controller n Suction and discharge piping per NFPA 20

n Pressure sensing lines complete per NFPA 20 n All electrical components pre-wired at factory

n Listed OS & Y gate & butterfly valves n Complete system hydrostatically tested

n Suction and discharge pressure gauges

dieSel driVen Fire puMp paCkageS alSo inClude


n Dual batteries with racks and charger n Flexible exhaust connector

n UL listed fuel tank sized per NFPA 20 n Engine cooling loop

n Residential grade muffler

optionS aVailable
n Witnessed and non-witnessed complete n Main system pressure relief valve with
system performance test enclosed waste cone

n Test line outlet to connect to remote tank n Relief valve for jockey pump line
with FM approved flow meter, isolation
valves & air release valve n Double wall fuel tank

n Test loop back to suction with FM approved n Fuel tank spill reservoir
flow meter, isolation valves & air release valve
n Critical grade muffler
n Bypass loop with check valve, isolation
n Packaged system drains piped to edge of skid
valves & air release valve
n Complete fire pump house
VertiCal turbine Horizontal Split CaSe
n UL listed and FM approved n UL listed/FM approved NFPA-20 design
NFPA-20 design n Flows from 250 to 5000 GPM
n Flows from 500 to 4500 GPM n Pressures from 40 to 245 PSI
n Pressures from 70 to 387 PSI (40 to 190 PSI at 50Hz)
n Special materials for n Diesel and Electric driven
seawater applications
n Diesel and Electric driven

VertiCal Split CaSe


n UL listed and FM approved
NFPA-20 design
n Flows from 250 to 2500 GPM VertiCal in-line
n Pressures from 40 to 200 PSI
n UL listed and FM approved
(40 to 155 PSI at 50Hz)
NFPA-20 design
n Space-saving design
n Flows from 50 to 750 GPM
n Pressures from 40 to 160 PSI
(40 to 120 PSI at 50Hz)
n Space-saving design
Fire puMp HouSeS
n Designed to meet specific
environmental requirements

n All-steel building

n Easy access entries

n Electric heaters with built-in


thermostat

n Continuous duty exhaust fan

n AC motor/solenoid operated louver

n Interior fluorescent and flood light, n Finished through wall or floor penetration
exterior 70 W HPS light
n Mini power zone (electric packages)
n Sprinkler system per NFPA
n Interior wall liner (optional)

SuMMary
n Each unit complete with Aurora fire
n All packaged systems hydrostatically tested
pump, Aurora jockey pump, controllers
and associated pressure sensing lines, n Packaged systems performance
valves, piping and electrical wiring. test available
n Built to NFPA 20 & NEC standards n Electric or diesel driven

n ISO 9001 Facility n Skid-mounted or completely housed

n UL listed/FM approved components n Single source responsibility

NOTE: Aurora Pump reserves the right to make revisions to its products and their specifications, and to this bulletin and related information, without notice. AP-PFPS 4/03 PRINTED IN U.S.A.

Ñ Your Authorized Local Distributor Ñ AURORA PUMPS ARE Marketing & SaleS:
800 airport road • north aurora, illinois u.s.a. • 60542
phone: (630) 859-7000 u.s.a./Canada Fax: (630) 859-7060
R
FM WorldWide Fax: (630) 859-1226

LISTED APPROVED aurora MFg. plant:


800 airport road • north aurora, illinois u.s.a. • 60542
sales oFFiCes in all major Cities and Countries
Refer to “Pumps” in yellow pages of your phone directory
for your local Distributor
AURORA
®

COMPLETE PUMP SOLUTIONS


for Fire Protection
WWW.AURORAPUMP.COM
PUMP SOLUTIONS FOR FIRE PROTECTION

AURORA

Aurora Pump provides fire protection pumping for a variety of


solutions throughout the world.
With over ninety years of experience, Aurora’s commitment to excellence goes beyond the product line Pictured at top: Packaged Fire Pump System.
Pictured at bottom: Typical housed diesel driven fire
by being dedicated to keeping our customers, distributors and employees constantly educated and pump with test meter.

updated on the leading developments in fire protection. Our computer software programs assist with
selecting the best pumps and systems along with providing pump drawings and specifications. These
programs save valuable time in the selection and evaluation of pumps and systems.

As an ISO 9001 registered company, Aurora Pump is committed to quality. In addition, to meet
your time-critical requirements, Aurora offers the Red Hot quick ship program for total fire pump
packages. Along with our outstanding customer service, Aurora will keep your fire pump system at
peak performance for years to come. You can rely on Aurora Pump and our qualified distribution
network to provide total pump solutions for fire protection.

Vertical Inline End Suction Horizontal Split Case

Model 383 Model 384 Models 481, 485, 491, 492, 495
Single Stage Inline Fire Pump End Suction Fire Pump Horizontal Split Case Electric Drive
Fire Pumps
Flows: 50 to 1,500 GPM (11.3 to 340 m /hr) 3
Flows: 50 to 1500 GPM (11.3 to 340 m /hr) 3

Pressures: 40 to 159 PSI (2.7 to 11 bar) Pressures: 40 to 225 PSI (2.7 to 15.5 bar) Flows: 250 to 5,000 GPM (56.8 to 1135 m3/hr)
Pressures: 40 to 435 PSI (2.7 to 30 bar)
• UL Listed/FM Approved/NFPA-20 Design • UL Listed, FM Approved Performance
• Space Saving Vertical Design • Electric and Diesel Speeds • UL Listed/FM Approved/NFPA-20 Design
• Easy Maintenance without Disturbing Surrounding Piping • Back Pullout Design for Easy Pump Service without • For Commercial, Industrial and Marine Use
• Bronze-Fitted Pump Construction Disconnecting Pipe • Diesel and Electric Driven Available
• Frame-Mounted Design • Lower Initial Cost
• Small Footprint Ideal for Retrofit • Quicker Delivery with Red Hot Quick Ship Program
• Designed for Installations such as Schools, Office Buildings • Ease of Maintenance
and Hospitals

2
PUMP SOLUTIONS FOR FIRE PROTECTION

Fire Pumps and Systems


Vertical Split Case Diesel-Driven Split Case Vertical Turbine

Model 483 Models 481, 485, 491, 492, 495


Vertical Split Case Electric Drive Fire Pump Horizontal Split Case Diesel Drive Fire Pumps Fire Pump Vertical Turbine
Flows: 250 to 2,500 GPM (56.8 to 568 m3/hr) Flows: 250 to 5,000 GPM (56.8 to 1,135 m3/hr) Flows: 250 to 4,500 GPM (56.8 to 1,022 m3/hr)
Pressures: 40 to 200 PSI (2.7 to 13.8 bar) Pressures: 40 to 435 PSI (2.8 to 30 bar) Pressures: 50 to 370 PSI (3.4 to 25.5 bar)

• UL Listed/FM Approved/NFPA-20 Design • UL Listed/FM Approved/NFPA-20 Design • UL Listed/FM Approved/NFPA-20 Design


• For Commercial, Industrial and Marine Use • For Commercial, Industrial and Marine Use • For Commercial, Industrial and Marine Use
• Electric Driven Available • Diesel and Electric Driven Available • Special Materials for Seawater Applications
• Lower Initial Cost • Lower Initial Cost • Diesel and Electric Driven
• Ease of Maintenance • Quicker Delivery with Red Hot Quick Ship Program
• Ease of Maintenance

Jockey Pump Packaged System Compact System

Models PVM & PVMX Packaged Fire Pump Systems Compact Fire Pump Systems
• UL Listed/FM Approved Aurora Fire Pump
®
Flows to 750 GPM (170.3 m3/hr)
Jockey Pumps • UL Listed/FM Approved Fire Pump Controller Pressures to 160 PSI (11.0 bar)

Horsepower: 1/2 to 40 • ETL Listed • Ideal for Smaller Areas – Fits through a 36" Doorway
Flows: 50 GPM (11.3 m3/hr) • Aurora Jockey Pump • Multiple Starting Methods Available for the Fire Pump
Capacities: 215 GPM (48.8 m3/hr) with Optional Automatic Transfer Switch
• UL Listed Jockey Pump Controller
Pressures: 330 PSI (22.7 bar)
Heads: 800 Feet (244 m) • Pressure Sensing Lines Complete per NFPA 20 • Optional City Bypass
Temperatures: 250°F (121°C) • Listed OS & Y Gate & Butterfly Valves with Tamper Switches
• Space-Saving Design Recommended Where Floor Space Is Extremely Limited • Suction and Discharge Pressure Gauges
• Available in Cast Iron or 316 Stainless Steel Materials • Automatic Casing Air Release Valve
• Standard TEFC Motor • Casing Pressure Relief Valve (Electric Packages)
• Hose Header with Valves, Caps & Chains
• Suction and Discharge Piping per NFPA 20
WWW.AURORAPUMP.COM • Removable Lifting Lugs 3
Fire Pump Houses

• AC Motor/Solenoid Operated Louver


• Interior Fluorescent and Flood Light,
• Designed to Meet Specific Environmental Requirements Exterior 70 W HPS Light
• All-Steel Building with Seismic Certification • Sprinkler System per NFPA 13
• Easy Access Entries • Finished through Wall or Floor Penetration
• Electric Heaters with Built-In Thermostat • Single Point Electrical Connection
• Continuous Duty Exhaust Fan • State Certification Label

Accessories
• Casing Relief Valve/Air Relief Valve • Diesel Engine Mufflers
• Eccentric Suction Reducers, Concentric • Exhaust Flex Connectors
Discharge Increasers • City Bypass
• Test Manifold, Hose Valves, Ball Drip Valve • Backflow Preventer
• Main Relief Valve, Waste Cone • Insulated Exhaust Piping
• Flow Metering Systems • Roof Curb for Vertical Turbine Installation and Removal
• Diesel Batteries, Racks and Cables • Alarms and Tamper Switches Prewired to a
• Double Wall Fuel Tanks and Fittings Common Junction Box

ST ER E D Q U
EGI
ALI
R
ISO 9001

TY SYSTEM

800 AIRPORT ROAD, 3601 FAIRBANKS AVENUE,


NORTH AURORA, ILLINOIS 60542 KANSAS CITY, KANSAS 66106
WWW.AURORAPUMP.COM

Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.
AF-02-1001 03/25/13 © 2013 Pentair Ltd. All Rights Reserved.
AURORA
®

SPLIT CASE FIRE PUMPS FOR


BUILT PER
NFPA20

INDUSTRIAL & OFFSHORE


APPLICATIONS
R

LISTED

WWW.AURORAPUMP.COM
SPLIT CASE FIRE PUMPS FOR INDUSTRIAL
& OFFSHORE APPLICATIONS
Aurora® split case pumps are specifically designed and tested for fire service applications where
reliability of performance is vital. Split case pumps are specified when the source of water is
located above the surface of the ground and provides a positive suction pressure to the pump at any
performance point.
Features
• Designed and built per NFPA20 for maximum reliability
• UL Listed and FM Approved in alternate metallurgies
• ABS Certification Available
• 60 Hz and 50 Hz electric and diesel speeds
• Design optimized for space considerations, ease of installation and maintenance
• Custom packaged systems available
Materials Of Construction
To meet the rugged demands of fire protection in industrial and offshore environments,
Aurora split case pumps are available in:
• 316 Stainless Steel • CD4MCu Super Duplex Stainless Steel
• Duplex 2205 Stainless Steel • Nickel Aluminum Bronze
• Cast Iron Bronze-Fitted
Performance
Pump Model Flow Pressures Pump Model Flow Pressures
1250–1500 gpm 95–140 psi 2000–2500 gpm 110–215 psi
6-481-18B 8-481-24
284–341 m3/hr 67–98 m 454–568 m3/hr 77–151 m
1000–2000 gpm 75–140 psi 2500–3500 gpm 81–205 psi
6-481-18C 10-471-20A
227–454 m3/hr 53–98 m 568–795 m3/hr 60–144 m
1250–2000 gpm 80–168 psi 3000 gpm 123–200 psi
6-481-20 284–454 m3/hr 56–118 m 10-471-26A 681 m3/hr 86–141 m
2000–2500 gpm 52–145 psi 4000–5000 gpm 63–225 psi
8-481-17B 10-491-20
454–568 m3/hr 37–102 m 908–1136 m3/hr 44–158 m
1250–2000 gpm 82–200 psi 3500–4500 gpm 91–188 psi
8-481-21 12-471-20A
284–454 m3/hr 58–141 m 795–1,022 m3/hr 64–132 m
2500 gpm 100–193 psi 3500–5000 gpm 133–206 psi
8-481-21A 12-471-26A
568 m3/hr 70–136 m 795–1,136 m3/hr 94–145 m

USA THE NETHERLANDS


800 AIRPORT ROAD, PARALLELWEG 4
NORTH AURORA, ILLINOIS 60542 7102 DE WINTERSWIJK
630-859-7000, FAX 630-859-7060 T +31 101543 547474
WWW.AURORAPUMP.COM

Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.
AF-02-1046 05/24/16 © 2016 Pentair plc. All Rights Reserved.
AURORA
®

COMMERCIAL HVAC
AND PLUMBING
FLUID HANDLING
SOLUTIONS WWW.AURORAPUMP.COM
COMMERCIAL HVAC AND PLUMBING FLUID HANDLING SOLUTIONS

AURORA

Aurora Pump provides commercial HVAC and Plumbing pumping


solutions for a variety of markets throughout the world.
With over ninety years of experience, Aurora’s commitment to excellence goes beyond the product
line by being dedicated to keeping our customers, distributors and employees constantly educated
and updated on the leading developments in technology. Our computer software programs assist with
selecting the best pumps and systems along with providing pump drawings and specifications. These
programs save valuable time in the selection and evaluation of pumps and systems.

As an ISO 9001 registered company, Aurora Pump is committed to quality. In addition, to meet your
quick ship requirements, the Aurora Distribution Center is stocked with parts and pumps to handle
same day shipments. These components, along with our outstanding customer service program, will
keep your Aurora Pump system at peak performance for years to come. You can rely on Aurora Pump
Pictured at top: High Rise Building, Mexico City, MX. Pictured in
and our qualified distribution network to provide total fluid flow solutions. the middle and at bottom: Texas Children’s Hospital, Houston, TX.

100 Series 200 Series

Models 110A–120B Model 130 Model 210 Model 220


One and Two Stage Close Coupled Single Stage One and Two Stage Single Stage Condensate
Regenerative Turbine Pumps Regenerative Turbine Pumps Condensate Systems and Boiler Feed Systems
Flows: Up to 150 GPM (34 m3/hr) Flows: Up to 50 GPM (11.4 m3/hr) Flows: Up to 150 GPM (34 m3/hr) Flows: Up to 180 GPM (40.8 m3/hr)
Heads: Up to 920' (280 m) Heads: Up to 700' (213 m) Heads: Up to 270' (82.2 m) Heads: Up to 170' (51.8 m)
Temperatures: Up to 275°F (135°C) Temperatures: Up to 212°F (100°C) Temperatures: Up to 190°F (88°C) Temperatures: Up to 200°F (93°C)

• Ideal for high head low flow applications • Self-priming feature (Model 133) • Long life receiver prevents corrosion • Long life fabricated steel receiver
• Handles liquids entrained with up to 20% • O-ring gaskets prevent leakage • Brass water level gauge • Optional back angle thermometer
gases and vapors • Self-centering impeller • Interchangeable design provides for • Optional brass water level gauge
• Increases system reliability with • Water slingers protect bearings future expansion • Trouble-free float switch
constant flows • Completely assembled piping
• Mechanical seal with carbon and • Interchangeable design provides for
Ni-resist faces for hot water performance • Accessibility to pumps and other components future expansion
• Double suction impeller minimizes axial thrust • Pumps handle entrained air and vapor with • Back pull-out design simplifies disassembly
• Replaceable channel rings liquid to eliminate vapor lock • Dynamically balanced impeller
• Straight through in-line piping (Models 134 and 135) • Stainless steel shaft designed for
minimum deflection

2
COMMERCIAL HVAC AND PLUMBING FLUID HANDLING SOLUTIONS

Fluid Handling Products


200 Series 300 Series

Model 280 Model 320 Models 340–360 Model 370


One and Two Stage Single Stage Single Stage Two Stage
Boiler Feed Systems End Suction Pumps End Suction Pumps End Suction Pumps
Flows: Up to 100 GPM (22.7 m3/hr) Flows: Up to 400 GPM (90.8 m3/hr) Flows: Up to 4500 GPM (1,022 m3/hr) Flows: Up to 310 GPM (70.4 m3/hr)
Heads: Up to 575' (175 m) Heads: Up to 210' (64 m) Heads: Up to 360' (110 m) Heads: Up to 790' (241 m)
Temperatures: Up to 210°F (99°C) Temperatures: Up to 225°F (107°C) Temperatures: Up to 300°F (149°C) Temperatures: Up to 300°F (149°C)

• 3/16" carbon steel receiver • Low noise level • Flexible and close coupled models • Dynamic balanced impeller
• Brass float valve • Vertical centerline discharge makes pump self-venting • Horizontal and vertical mounting • Case wearing rings are easily replaceable
• Brass water level gauge with shut-off valve • Back pullout design simplifies disassembly (close coupled pumps) • High temp mechanical seal is standard
• Interchangeable design provides for future • Case wearing rings are easily replaceable • Computer machined components with • Carbon steel shaft designed for
system expansion 360° registered fits minimum deflection
• Dynamically balanced impeller is keyed to shaft
• 3-way strainer valve provides • Vacuum cast impeller • Relief line assures adequate venting
• Stainless steel shaft designed for minimum deflection
dependable operation • Power frames provide maximum interchangeability • Bronze shaft sleeve prevents shaft wear
• Completely assembled piping • Factory hydrostatic test • Factory hydrostatic test
• Pumps designed for boiler feed will handle • Certified performance test available • Certified performance test available
entrained air and vapor • Back pullout design simplifies disassembly

300 Series 3800 Series 400 Series

Model 380 Models 3801–3804 Models 410–420 Model 430


Single Stage In-Line Pumps Single Stage End Suction Pumps Single Stage Double Suction/ Two Stage Single Suction
Two Stage Single Suction Diagonal Split Case Pumps
Flows: Up to 600 GPM (136.3 m /hr) 3
Flows: Up to 4,200 GPM (954 m /hr) 3

Heads: Up to 170' (51.8 m) Heads: Up to 520' (180 m)


Split Case Pumps
Flows: Up to 400 GPM (90.8 m3/hr)
Temperatures: Up to 250°F (121°C) Temperatures: Up to 300°F (149°C) Heads: Up to 1,000' (305 m)
Flows: Up to 15,000 GPM (3,406 m3/hr)
Heads: Up to 600' (183 m) Temperatures: Up to 300°F (149°C)
• Back pullout casing with in-line suction • Offered in two models: Model 3801 close coupled
Temperatures: Up to 275°F (135°C)
and discharge and Model 3804 flexible coupled–frame mounted • 45° discharge allows suction discharge to be in
• Case wearing ring prevents wear on casing • 316 stainless steel impeller • Split case design simplifies disassembly bottom half of casing
• Dynamically balanced impeller • Double volute on 4" discharge and larger to reduce • Dynamically balanced impeller is keyed to the shaft • Dynamically balanced impeller is keyed to shaft
is keyed to the shaft bearing loads • Double row thrust bearings promote long life
• Case wearing rings prevent casing wear
• Carbon steel shaft is designed for • Gauge taps on suction and discharge on flanged models • Bearings selected for 50.000 hour minimum life
• Replaceable shaft sleeve prevents shaft wear
minimum deflection • 4 power frame sizes
• Interchangeable stuffing box for mechanical seals • Case wearing rings prevent casing wear
• Relief line assures adequate venting • Casing feet for easy back pullout or packing • Replaceable shaft sleeve prevents shaft wear
• Bronze shaft sleeve prevents shaft wear • Regreaseable bearings (Model 3804 only) • Grease lubrication purges old grease from bearings • Grease lubrication purges old grease from bearings
• Integral cast support feet • Coupling guard (flex coupled design) • Double row thrust bearings promote long life • Interchangeable stuffing box for mechanical seals
• Formed steel base (flex coupled design) • Bearings selected for 50.000 hour minimum life or packing

WWW.AURORAPUMP.COM 3
Fluid Handling Products
500 Series 700 Series

Models 520–530; 630–640 Models 7710–7720 Models 770/790


Single Stage Vertical Wet Pit Variable Speed Constant Pressure
Sump and Sewage Pumps Pumping Systems Booster Systems
Flows: Up to 1,200 GPM (272.5 m3/hr) The system supports up to four Flows: Up to 10,000 GPM (2,271 m3/hr)
Heads: Up to 180' (54.8 m) variable speed pumps and one Heads: Up to 500' (152 m)
Temperature: Up to 180°F (82°C) constant speed pump Temperature: Up to 275°F (135°C)

• Motor mounting bracket assures alignment with tongue • System includes pumps, motors, • System includes pumps, motors, controller
and groove machining VFD drives and sensors and sensor
• Bronze sleeve bearing provided for extra life • One contact point of responsibility • Completely assembled and prewired for
• Thrust ball bearing is regreaseable and is protected • Easy start-up with menu-driven easy installation
from contamination programmable control • Sensing control panel in NEMA 1 enclosure
• Liquid end includes an impeller which can be • Save money with Best Efficiency Control is UL Listed
adjusted externally • Space saving design • Pressure gauges located on suction and
• Discharge pipe is secured to baseplate and threaded for discharge manifold
• Increased system security
convenient piping • Groutable formed steel base provides
• Line shaft bearings provide rigid support complete support for easy installation

PVM Series 1000 Series

PVM Series Hydronics Accessories


Multi-Stage Vertical • Series 1020 Y-Strainers
In-Line Centrifugal Pumps • Series 1030 Suction Diffusers
• Series 1040 Combination Valve
Flows: Up to 210 GPM (13 LPS)
Heads: Up to 895' (273 m) • Series 1050 Air Separator
Temperature: Up to 250°F (121°C) • Series 1060 Expansion Tanks
• Boiler Feed • Condensate Return • Series 1070 Circulators
• Jockey Pump • Irrigation • Series 1080 Heat Exchangers
• Chemical Feed • Car Wash • Series 1090 Flexible Connectors

800 AIRPORT ROAD, NORTH AURORA, ILLINOIS 60542 WWW.AURORAPUMP.COM


Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.
A-02-1000 11/17/12 © 2012 Pentair Ltd. All Rights Reserved.
AURORA
®

INDUSTRIAL
PRODUCTS WWW.AURORAPUMP.COM
INDUSTRIAL PRODUCTS

AURORA

Aurora Pump has devoted itself since 1919 to the design and manufacture
of a wide variety of fluid handling pumps for a vast amount of applications.
Aurora Pump’s commitment to excellence is more than just a complete product line. With new product
development, improved pump efficiencies and expansion of sizes to accommodate a broader range of
applications, our growth has been continuous and aggressive. Not surprisingly, Aurora Pump’s quality
management system is ISO 9001 Registered.

Aurora Pump offers computer software selection such as H2Optimize and R

Encompass that is up to date and ready to serve your needs.


The software programs select the best pump for a specific set of conditions and provide pump drawings,
specifications and dimensions. Further product information is available 24 hours a day, 7 days a week, at
our website www.aurorapump.com.

100 Series 200 Series

Models 110A–120B Model 130 Model 150 Model 210


One and Two Stage Close Coupled Single Stage Regenerative Turbine One and Two Stage
Regenerative Turbine Pumps Regenerative Turbine Pumps Process Pumps Condensate Systems
Flows: Up to 150 GPM (10 LPS) Flows: Up to 50 GPM (3 LPS) Flows: Up to 130 GPM (8 LPS) Flows: Up to 150 GPM (10 LPS)
Heads: Up to 920' (280 m) Heads: Up to 700' (213 m) Heads: Up to 1,200' (366 m) Heads: Up to 270' (82 m)
Temperatures: Up to 275˚F (135˚C) Temperatures: Up to 212˚F (100˚C) Temperatures: Up to 500˚F (260˚C) Temperatures: Up to 190˚F (88˚C)

• Boiler Feed Service • Hot Water Circulating Pumps • Chemical Process • Condensate Service
• Condensate Service • Cooling Tower Makeup • Refineries • Boiler Feed Service
• Cooling System • Boiler Feed Service • Pulp and Paper • Circulating Systems to
• Booster System • Transfer Service • Transfer Service Overhead Storage Receivers
• Transfer Service • TV and Radar Tube Cooling

2
Fluid Handling
Aurora Pump’s distribution center is stocked with parts to handle same-day shipments. These parts, manufactured
®

to original specifications, keep your pumps performing at peak performance for years to come.

200 Series 300 Series

Model 220 Model 280 Model 320 Model 326


Single Stage Condensate One and Two Stage Close Coupled Single Stage In-Line Mounted
and Boiler Feed Systems Boiler Feed Systems End Suction Pumps Centrifugal Pumps
Flows: Up to 180 GPM (11 LPS) Flows: Up to 100 GPM (6 LPS) Flows: Up to 400 GPM (25 LPS) Flows: Up to 140 GPM (9 LPS)
Heads: Up to 170' (52 m) Heads: Up to 575' (175 m) Heads: Up to 210' (64 m) Heads: Up to 55' (17 m)
Temperatures: Up to 200˚F (93˚C) Temperatures: Up to 210˚F (99˚C) Temperatures: Up to 225˚F (107˚C) Temperatures: Up to 225˚F (107˚C)

• Boiler Feed Service • Boiler Feed Service • Hot Water Circulating Pumps • Hot or Chilled Water Circulation
• Condensate Service • Condensate Service • Cooling Tower Makeup • Pressure Booster Systems
• Cooling System • Boiler Feed Service • Cooling Towers
• Booster System • Transfer Service
• Transfer Service • TV and Radar Tube Cooling

300 Series

Models 340–360 Model 370 Model 380


Single Stage Two Stage Single Stage
End Suction Pumps End Suction Pumps In-Line Pumps
Flows: Up to 4,500 GPM (284 LPS) Flows: Up to 310 GPM (20 LPS) Flows: Up to 4,500 GPM (284 LPS)
Heads: Up to 360' (110 m) Heads: Up to 790' (240 m) Heads: Up to 370' (113 m)
Temperatures: Up to 300˚F (150˚C) Temperatures: Up to 300˚F (150˚C) Temperatures: Up to 250˚F (121˚C)

• Chilled Water • Boiler Feed Service • In-Line Service


• Heating and Air Conditioning • Condensate Service • Booster Service
• Cooling Tower Service • Low NPSHR
• Water Booster System

WWW.AURORAPUMP.COM 3
INDUSTRIAL PRODUCTS

Fluid Handling

PVM Series 3500 Series 3800 Series 400 Series

PVM Series Models 3550–3560 Models 3801–3804 Models 410–420


Multi-Stage Vertical Industrial Process Pumps Single Stage Single Stage Double
In-Line Centrifugal Pumps ASME/ANSI B73.1M End Suction Pumps Suction/Two Stage Single
Suction Split Case Pumps
Flows: Up to 210 GPM (13 LPS) Flows: Up to 7,000 GPM (442 LPS) Flows: Up to 4,200 GPM (265 LPS)
Heads: Up to 895' (273 m) Heads: Up to 725' (221 m) Heads: Up to 520' (180 m) Flows: Up to 15,000 GPM (950 LPS)
Temperatures: Up to 250˚F (121˚C) Temperatures: Up to 650˚F (343˚C) Temperatures: Up to 300˚F (149˚C) Heads: Up to 600' (183 m)
Temperatures: Up to 275˚F (135˚C)
• Boiler Feed • Chemical • Offered in Two Models:
• Condensate Return • Petrochemical - 3801 is Close Coupled • Cooling, Heating and
- 3804 is Flexible Close Coupled Air Conditioning Service
• Jockey Pump • Mining
• Heating and Air Conditioning • Boiler Feed Service
• Irrigation • Pulp and Paper
• Chilled Water • Condensate Service
• Chemical Feed • Consumer Products
• Cooling Tower Service • High Pressure Water Service
• Car Wash • General Industry
• General Service

400 Series 500 Series 600 Series

Model 430 Models 520–530 Model 610 Models 630–640


Two Stage Single Stage Single Stage Single Stage
Single Suction Diagonal Vertical Wet Pit Sump Wet Pit, Sump Vertical Wet Pit Sump
Split Case Pumps and Sewage Pumps and Sewage Pumps and Sewage Pumps
Flows: Up to 400 GPM (25 LPS) Flows: Up to 1,200 GPM (76 LPS) Flows: Up to 20,000 GPM (1,262 LPS) Flows: Up to 1,000 GPM (63 LPS)
Heads: Up to 1,000' (305 m) Heads: Up to 180' (55 m) Heads: Up to 250' (76 m) Heads: Up to 90' (27 m)
Temperatures: Up to 300˚F (150˚C) Temperatures: Up to 180˚F (82˚C) Temperatures: Up to 250˚F (121˚C) Temperatures: Up to 180˚F (82˚C)

• Boiler Feed Service • Condensate Service • Horizontal and Vertical • Heavy Duty Vertical Wet Pit
• High Pressure Transfer • Light Duty Sump Service • Solids Handling Sewage Treatment
• Condensate Transfer • Dirty Liquid Service

4
INDUSTRIAL PRODUCTS

Fluid Handling

600 Series 700 Series

Models 650–660 Model 670 Model 680 Models 7710–7720


Single Stage Single Stage Single Stage Variable Speed
Wet Pit, Sump Vertical Wet Pit Sump Vertical Wet Pit Sump Pumping Systems
and Sewage Pumps and Sewage Pumps and Sewage Pumps
Intelliboost
Flows: Up to 2,600 GPM (164 LPS) Flows: Up to 1,025 GPM (65 LPS) Flows: Up to 25 GPM (2 LPS)
Heads: Up to 240' (73 m) Heads: Up to 160' (49 m) Heads: Up to 180' (55 m) • Chilled Water Systems
Temperatures: Up to 250˚F (121˚C) Temperatures: Up to 180˚F (82˚C) Temperatures: Up to 190˚F (88˚C) • Hot Water Systems
• Medium Duty • Sludge and Slurry Pumping • Lubrication and Flushing of Clean Water • Booster Service
• Horizontal and Vertical • Food Processing for Seals and Packing Boxes
• Sludge and Slurry Pumping • Abrasive Mixtures

700 Series 1000 SERIES – Hydronics Accessories

Models 750–760 Models 770–790 1020 Series 1030 Series


Constant Pressure CP Boss Y-Strainers Suction Diffusers
Booster Systems Booster Systems
1/2" NPT – 16" Flanged 21 Sizes Up to 12" x 12"
Apco-PM CP-Boss
Apco-PC Duplex and Triplex • 304 Stainless Steel Screen • 304 Stainless Steel Screen
• Threaded or Flanged • 125# ANSI Flanges
• Constant Pressure Booster System • Constant Pressure Booster System
• High Rise Building

WWW.AURORAPUMP.COM 5
Fluid Handling
Aurora Pump Hydronic Accessories give you the products necessary to build a reliable HVAC system.
®

1000 SERIES – Hydronics Accessories

1040 Series 1050 Series 1060 Series 1070 Series 1090 Series
3DV Combination Valves Air Separators Expansion Tanks Circulators Flexible Connectors
1-1/4" NPT to 12" Flanged 1" to 24" Pipe Inlet 7 Gallons to 211 Gallons • Custom In-Line Circulators 1/2" to 14"

• Non-Slam Check Valve • Steel Construction • Horizontal or Vertical • Wet Rotor Circulators • Flanged Connectors
• Shutoff Valve • With or Without Strainers • Steel or Fiberglass • 3-Piece Circulators • Threaded Connectors
• Throttling Valve • ASME or Non-ASME Models • Dry Rotor Circulators • Multi-Ply Connectors

800 AIRPORT ROAD, NORTH AURORA, ILLINOIS 60542 WWW.AURORAPUMP.COM


Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.
A-02-1002 03/19/13 © 2013 Pentair Ltd. All Rights Reserved.
on t h e l i f e
We ir r i g a t i u r s o u
with o

With 50 years expertise. A wide matchless range of pump and motors from six
different factories of the group, ISO9001 quality systems and futuristic fechnology. Just
a few among several things that made Ronald a renowned global brand.
Ronald water pump, not only pumping water, but also pumping trust
worldwide.
HSC
I S O9001

You might also like