You are on page 1of 2

Badger Meter Europa GmbH

Nürtinger Str. 76
72639 Neuffen (Germany)
Tel. +49-7025-9208-0
Fax +49-7025-9208-15
www.badgermeter.de
badger@badgermeter.de

DataControl 2500
Intelligent controller and data recorder

Features
• Calibration with front keypad or software
• Up to 4 sensors simultaneously
• Totalisator for each channel available
• Logger data can be shown in a graph or a table

Description Application
The DataControl 2500 is a versatile instrument to interface - 2-channel flow measurements
to standard sensors with analog and digital outputs. The - Flow control
measured input signals are evaluated for internal recording - Pump control
and control. - Monitored dual tank measurement
- Event recording
Applications - Data recording

The instrument can be interfaced simultaneously with up


to four 4-20 mA or 0-5 V analog and four digital sensors Parameters
performing measurements and computing parameters such
as: Level, volume, open channel flow, temperature, pH or Units with analog output 4-20 mA such as level, pressure,
pressure. pH and temperature meters can be converted to their
respective functions like volume/ level, flow rate, pressure,
The instrument provides a supply voltage 24 V/0.5 A as acidity and temperature by using one of the
power supply for the sensors. The output signals from preprogrammed conversion formulas or via a custom set
each connected sensor are adapted and evaluated. points table. When a 2-wire powered ultrasonic level
transmitter is connected, the DataControl 2500 can be set
The instrument can be programmed with various set to interpret the signal as percentage, distance / level,
points resulting in 2 analog outputs and 2 digital outputs volume or flow. Conversion formulas for different types of
or 6 relays. Complex switching sequences are possible and tanks, weirs and flumes are stored in the memory to easily
a pump rotation for even wear can be configured. configure volume & flow applications; alternatively a 35
point custom table can be used. Addition, subtraction and
As a recorder, the instrument is capable of storing as averaging can be made via the unit. Totalizer functionality
much as one-month’s data at one-minute intervals or more is provided for each channel.
than a year’s data at 15-minute intervals, logging all data
channels. The longest adjustable time interval is 99
minutes.

UF_DC2500_DB_02_0901.doc
Reprint of texts or text extracts requires prior written authorization of Badger Meter Europa GmbH.
Misuse of texts, pictures or company logo will be prosecuted.
Technical data
Type DataControl 2500 (8 channel measurement)
Housing material Plastic, UV-resistant
Dimensions HxWxD 240 x 270 x 76 mm
Protection class IP65
Operating temperature range -20°C to +60°C
Outputs 2 analog outputs 4-20 mA or 0-5 V, isolated
2 digital outputs max. 80 VDC / 30 mA
6 relays, max. 250 VAC / 6 A
RS232 or RS485
Voltage output 24 VDC / 50 mA and 12 VDC
Inputs 4 analog inputs 4-20 mA, isolated
4 digital inputs 1,3 VDC / 2 mA, optically isolated
Display function 8 lines for level, flow, total, volume, distance, temperature, pH or pressure
Display language English
Supply voltage 90 – 230 VAC / 10 W
Programming Via front keypad or PC with software (password protected)
Data logger 2 MB flash, programmable time intervals, capacity for approx. 44000 records, chart or graphics

Configuration Custom software


Configuration of the instrument can be done via the six Using a personal computer and the custom software
function keys and the graphical LCD display or via a supplied with the unit, the instrument can be configured
personal computer (PC) using the custom software supplied and all recorded data can be displayed in graphical or
with the unit. The configuration is password protected. alphanumerical format. The recorded data can also be
exported for further analysis in .csv format.

Data logging and communication • Independently programmable inputs


• Preprogrammed conversion formulas
• Data can be exported to PC
• Programed custom set point table
• Two Megabyte flash based storage
• Remote configuration and data retrieval
• Remote data retrieval
• Programmable control functions
• RS232 / RS485 network operation
• Programmable measurement functions
• Modem / GSM modem interface
• Firmware can be updated in the field

Remote communication with the instrument is possible


using RS232/RS485, modem or GSM modem (data &
SMS). Via this interface, configuration changes and data
retrieval are possible. Using the RS485 interface, a
network of up to 32 DataControl 2500 can be created. RF
telemetry is easily implemented by adding an external RF
transceiver.

UF_DC2500_DB_02_0901.doc
Reprint of texts or text extracts requires prior written authorization of Badger Meter Europa GmbH.
Misuse of texts, pictures or company logo will be prosecuted.