Professional Documents
Culture Documents
10100
PO Nº 1010005210
CLIENT PO Nº
CRCI-M98-32-M210-DA
UNIT / EQUIP. No :
R47-G-0012 A/B
DOCUMENT TITLE:
QFK-1494A 03
REVIEW RESPONSE BY CONTRACTOR:
CONTRACTOR review comments do not indicate either responsibility or liability for accuracy and completeness of this Document or alter any
contractual terms and conditions.
2018-09-19
This document is property of UTE TR Naphtha RT and TR Saudia for Services and Contracting Co Ltd.
Its reproduction without previous permission in writing is strictly forbidden.
.
10100-00-082-PD-0002-tmp02
Saudi Aramco 2741-ENG (11/2010)
INDICATES INFORMATION TO BE COMPLETED BY PURCHASER; BY MANUFACTURER OF PUMPS OR PUMPS PER API 685
PURCHASERS REFERENCES SITE CONDITIONS
REVISION DESCRIPTION
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
PUMP MARK NO(S). R47 -G- 0012A , R47 -G- 0012B / / RATED SPEED (NOTE 19) RPM 3600
DATE
-G- , -G- / / DRIVER NAME PLATE POWER RATING (NOTE 17) HP 93.9
JOB ORDER/EWO NO.
GEAR UNIT DATA SHEET NA TOTAL DIFF. HEAD Ft 502 446 446 / 416
LUBE OIL SYST DATA SHEET NA EFFICIENCY % 10.4 18.5 18.5 / 19.8
SAFETY INSTRUCTION SHEET NA REQUIRED POWER HP 70 79.6 79.6 / 83
BY/DATE
OTHER
RELATIVE DENSITY AT NORMAL FLOW TEMP. 1.0893 (5) MIN. IMPELLER DIAMETERS
VISCOSITY AT FLOW TEMP. CS / CP / SSU 1.2 cP MAX. MIN.
DESIGN CERTIFICATION
pH CI PPM
CONSTRUCTION DATA
PUMP TYPE
OPERATING CONDITIONS HORIZONTAL (BET. BRGS) / OVERHUNG
/ VERT. IN-LINE INTEGRAL SHAFT
IS COVERED, FOR ALL APPROVAL
CAPACITY NORMAL USGPM 120 (9) (10) CASING MOUNT: CENTERLINE FLANGE CENTERLINE
RATED USGPM 120 (11) FOOT
RATED TOTAL DIFFERENTIAL HEAD Ft 446 (12) VERT. IN-LINE IN-LINE CASE SUPPORTED
NPSH AVAILABLE AT SUCTION FLG. CASING SPLIT AXIAL RADIAL
AT RATED CAPACITY Ft 16.8 (13) CASING TYPE DOUBLE VOLUTE SINGLE VOLUTE
REVISION VALIDATION
MAX. DISCH. PR. AT RATED CAP. PSIA 234 (14) / DISCHARGE 3" 300# RF TOP
DATA SHEET FOR CAUSTIC MAKE-UP PUMPS, R47-G-0012 A/B DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
TOP NOZZLE SIDE NOZZLE END NOZZLE EACH NOZZLE INBOARD / OUTBOARD
NO NA
REQUIRED (SAUDI ARAMCO)
SHAFT SEALING
(DESIGN AGENCY)
Dh1
Dh2
4TH LETTER NA
Dsl
Dp
5TH LETTER NA
PIPING FOR PRIMARY SEAL API FIG. D-2 PLAN NA Dp = 4.055 IN
PIPING FOR THROTTLE BUSHING OR Dsl = NA IN (IF APPLICABLE)
AUXILIARY SEAL API FIG. D-3 PLAN NA Dh1 = 2.756 IN
REVISION VALIDATION
DATA SHEET FOR CAUSTIC MAKE-UP PUMPS, R47-G-0012 A/B DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO REV.NO.
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
ANTI-FRICTION TYPE
TILTING PAD DIAPHRAGM DISC PACK
LUBRICATION METHOD RADIAL THRUST RIGID ADJUSTABLE
GREASE CLOSE COUPLED
RING-OIL CONSTANT LEVEL ELASTOMERIC
LUBRICATOR, MAKE NA HYDRAULIC FIT KEYED
OIL BATH WITH EXT'L CIRCULATION SPACER: YES, NA IN NO
FORCED FEED COUPLING GUARD PARTIALLY ENCLOSED COMPLETELY ENCLOSED
DATE
SHAFT MOUNTED FAN JACKETED BEARING HOUSING 14 PIPING: PIPE / FITTINGS ASTM Same as casing
COILS IN BEARING HOUSING 15 BASE PLATE ASTM A36
16 MECH. SEAL SPRINGS ASTM NA
EXTERNAL CIRCULATING SYSTEM 17 MECH. SEAL OTHER METAL PARTS ASTM NA
OIL COOLING BY: 18 ROTOR/STATOR CAN ASTM ALLOY C-276
LIQ. PUMPED FOREIGN LIQ. AIR NONE 19 BEARING ASTM Carbon Graphite
STUFFING BOX COOLING YES NO
PEDESTAL COOLING YES NO NOISE SPECIFICATION
AND CERTIFICATION REQUIREMENTS, PER SAEP-334, UNDER
IS COVERED, FOR ALL APPROVAL
COOLING MEDUIM NA NA NA NA
DATA SHEET FOR CAUSTIC MAKE-UP PUMPS, R47-G-0012 A/B DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
NOTE: BY MANUFACTURER OF PUMPS PER ASME B 73.1 OR B 73.2
REVISION DESCRIPTION
INDICATES INFORMATION TO BE COMPLETED BY PURCHASER; BY MANUFACTURER OF PUMPS OR PUMPS PER API 685
UTILITIES INSPECTION AND TESTS
OBSER'D
According to 175-SPECIAL-024 JUL'17
CERT'D
WITN'D
NONE
ELECTRIC POWER AVAILABLE VENDOR'S STANDARD SHOP TEST
AC PHASE AS FOLLOWS
VOLTS
DC HZ HYDROSTATIC TEST
MAIN ELECTRIC DRIVER AC 480 3/60 WATER KEROSENE
CONTROLS AND PROTECTION AC 120 1/60 RUNNING TEST
DC 24 - PERFORMANCE TEST
JOB ORDER/EWO NO.
DATE
YES REQUIRED
PROVISIONS ONLY YES NO
DIMENSIONAL DRAWING OF
CONST. AGENCY/DATE
MILS P-P /
IN / SEC RMS /
PROXIMITY PAINTING
ENGG./DATE
31-AMSS-004
PUMP LBS 880 ASME B 73.1 ASME B 73.2
DRAWING COMPLETION CERTIFICATE NO.
REVISION VALIDATION
DATA SHEET FOR CAUSTIC MAKE-UP PUMPS, R47-G-0012 A/B DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
The shutoff head of the selected pumps shall not be more than 120% of rated head.
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
Notes:
(1) DELETED
(5) Liquid density at rated temperature and pressure is 67.94 lb/ft3. SG. at STD cond. (60/60) is 1.0931
(6) Indicated vapor pressure is the one to be used for NPSH available calculation (assumption: boiling liquid).
The actual vapor pressure is 2 PSIA. (vapor pressure of the sub-cooled liquid).
BY/DATE
OTHER
(7) DELETED
(8) DELETED
OPERATIONS/DATE
(9) DELETED
REVIEW FOR KEY DRAWINGS
REQUIRED (SAUDI ARAMCO)
(13) Based on elevation of lower TL of suction vessel of 3 ft above grade. No safety margin included.
(14) Estimated shut-off pressure: 280.5 psia. Shut-off pressure shall not exceed this value, including acceptance tolerances by API at bench test.
CERTIFIED/DATE
(15) DELETED
DESIGN CERTIFICATION
(DESIGN AGENCY)
(16) DELETED
(17) Pump and motor design to allow for automatic start-up of the pump (with control valve open at discharge).
ENGG./DATE
(18) DELETED
(19) DELETED
(20) DELETED
(21) Drain welded to the casing must match the metallurgy of the pump casing. Casing drain connection shall be gusseted
in two planes and shall be provided with a flanged valve terminated at the edge of the skid.
(22) DELETED
IS COVERED, FOR ALL APPROVAL
(23) Minimum material requirement: D-1 as per API 685 2nd Ed.
(24) The pump baseplate shall be constructed with sufficient structural stiffness. Seller shall design the skid without any
credit for grouting. The Baseplate shall be designed to ensure that unacceptable deflections do not occur during
REVISION VALIDATION
(25) DELETED
(26) The suction specific speed for all pumps shall not exceed 11,000 in U.S. units.
(27) Conditions for Tempered Water: Max. Pressure drop: 10 psi / Maximum Allowable Flow Rate for each pump: 6.6 gpm.
THIS REVISION NO.
DATA SHEET FOR CAUSTIC MAKE-UP PUMPS, R47-G-0012 A/B DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO REV.NO.