Ansul Large Dry Chemical Systems The Ansul system offers the quick The basic Ansul Large Dry Chemical
combine the flexibility of a hand portable response, large extinguishing agent System consists of: a storage tank to
fire extinguisher with the larger fire- capacity, longer discharge time and hold a quantity of dry chemical
killing power necessary to combat large increased flow rates necessary to combat extinguishing agent; nitrogen cylinder(s)
Class B (flammable liquids and gases) these large fires. In short, they protect to provide for pressurization of the tank
and Class C (electrical) fires. The Ansul areas which hand portable and wheeled and fluidization of the dry chemical;
system is ideally suited for protection of fire extinguishers cannot. hose line(s) to deliver the agent from the
extra hazardous areas where large fires storage tank to the nozzle assembly;
must be extinguished before they have a and a nozzle assembly to control and
chance to spread or increase in size. direct the flow of dry chemical to the fire.
003540
Why choose Ansul?
004973
Custom-adapted to your requirements.
The basic Ansul models offer a modular The long range nozzles increase the suppression and disaster, a remote
package of fire protection. The real range and flow rate of the dry chemical actuator can be mounted on the hose
strength of the Ansul system lies in its agent while narrowing the stream pattern reel assembly. This remote actuator
‘‘custom-adaptability’’ which allows the (see diagram). The long range nozzles allows the operator to quickly actuate the
basic system to be adapted to your allow the operator to effectively concent- system at the hazard site. By simply
requirements through the addition of one rate the flow of dry chemical agent at the pulling a ring pin and pushing a lever, the
or more of the Ansul options. The end fuel source of the fire. This concentration operator can bring dry chemical agent
result is a fire protection system which of agent is essential to the suppression from the main system to the nozzle
can satisfy your unique protection of flammable liquid/combustible gas assembly where he controls its
requirements. pressure fires. application to the fire.
Actuation
Package
Selector
Nozzles
Remote
Remote
Class D
PLUS-
Control
Agents
Valves
Turret
X = Available Note: Options shown are based on standard units. Consult Ansul for additional options or combinations not shown.
Large capacity. Modular. Rugged.
Properly used, the Ansul Large Dry killing power, the Ansul Large Dry Rugged Construction – We
Chemical System quickly and efficiently Chemical System is the most effective manufacture each Ansul system from
does what it was designed to do: put out piece of firefighting equipment for three high quality materials. The dry chemical
large fires before they have a chance to dimensional and gas/liquid pressure agent is carefully matched to the system
spread or do severe damage to lines. These types of fires demand a to ensure maximum fire-fighting
equipment or facilities. But consider system which can deliver a large flow of effectiveness. The Ansul system is
some of the other benefits of the Ansul extinguishing agent at the point of the thoroughly inspected at the factory
system: fire’s origin (i.e., the break in a pipe providing you with a top quality rugged
Fire-Killing Power – The Ansul system carrying a flammable liquid or gas). unit which will far outlast any other
is the maximum manual firefighting tool Minimum Personnel Required – Since equipment.
available. Its large agent capacity, long the Ansul system is the maximum Testing – We have conducted extensive
discharge time and tremendous dry manual firefighting tool available, it is tests on our systems, both at our test
chemical flow rate enable firefighters to ideal for protection of large hazards with field in Marinette and in the field under
contain and extinguish fires they might fewer people. One person can operate actual fire conditions. The result is a fire
otherwise miss. It gives the fire fighter any of the Ansul Large Dry Chemical suppression system that will work when
confidence to attack and extinguish fires Systems. you need it – in a fire situation.
before they become uncontrollable. Modular – The Ansul system is a self-
Efficient – Since it is manually operated, contained, modular unit. Any one of the
the Ansul Large Dry Chemical System basic models can be ‘‘custom-adapted’’
allows the firefighter to use only the to your fire protection requirements. In
amount of agent necessary to suppress a addition to custom adaptability, its
fire. A manual system enables the fire capabilities can be increased by adding
fighter to deliver the extinguishing agent more hoselines, hose reels, selector
to the exact location of the fire. Once the valves and turrets. These additions do
fire is suppressed, he/she simply turns off not necessitate extensive system
the unit, thereby ensuring no waste of dry modifications or rework and can be done
chemical. Recharge of the Ansul System as your fire protection needs increase.
is done on-the-spot, quickly and easily.
Effective – In addition to its great fire-
004962
Found where the risk of fire is high.
Fire protection can only be Remote Locations — When the area to Manufacturing
recommended following a careful be protected is remotely located or Industrial Manufacturing Operations
analysis of real and potential fire inaccessible to other forms of fire fighting (paint spray booths, dip and
hazards. This analysis includes: a equipment (wheeled or mobile quench tanks)
definition of the fire protection objective; extinguishers), the Ansul system can Warehouses
a determination of where and how the provide the quick response which is Steel Mills
extinguishing agent will be applied; and a essential to the containment and Paint and Solvent Mixing Areas
determination of the agent discharge suppression of rapidly growing fires. Machinery Lubricating Systems
time required to suppress the fire. Seconds make the difference in a large Flammable Liquid Storage Areas
Based on Ansul’s experience in fire fire. With the Ansul system, you have on-
protection analysis, the Ansul Large Dry the-spot fire suppression capability. Utilities
Chemical System is recommended Multiple Hazards — The Ansul Large Transformers
where the following conditions exist: Dry Chemical System with its built-in Generators
Large Fires — Hazardous areas flexibility can be expanded to include Turbines
involving potential large Class B and C additional hose lines and selector valves. Control Equipment
fires demand the fire killing power This flexibility allows the Ansul system to Fuel Storage Areas
provided by the Ansul system. Class A protect multiple hazards from one central
and D fire hazards can also be protected location. Natural Gas
using optional agents. Typical applications: LNG Tankers
Minimum Manpower — Any Ansul Natural Gas Plants
Large Dry Chemical System can be Petroleum Petrochemical Process Piping
operated by one person. It is ideally Loading Racks Vaporizers
suited for protection of hazardous areas Refinery Processing Equipment Compressors
where there is a limited number of Product Transfer and Storage Areas Liquefication Plants
firefighters. Offshore Platforms Sump Areas
Process Areas Truck Loading Areas
Marine
Tanker Decks
Machinery Spaces
Loading Docks
004963
004964 004965 004966
004967 004968
004970
ANSUL INCORPORATED, MARINETTE, WI 54143-2542 715-735-7411 Form No. F-91105-01 2003 Ansul Incorporated Litho in U.S.A.