Jackets & Topside Rigging Summary

Jacket Topside
ETAME PLATFORM
Trunnion 1 Trunnion 2 Trunnion 3 Trunnion 4 P1 P2
Sling Length (m) 42 42 43 43 35 35
MBL of Sling (MT) 2592 2592 1418 1418 3060 3060
Sling Angle (deg) 73.8 73.8 61.1 61.1 64.7 64.7
Sling Tension (MT) 531.8 529.3 226.5 227.4 433.3 462.8
Shackle SWL (MT) - - - - 1000 1000
FOS for Sling1) 4.9 4.9 6.3 6.2 7.1 6.6
FOS for Shackle2) - - - - 2.3 2.2

Jacket Topside
SEENT PLATFORM
Trunnion 1 Trunnion 2 Trunnion 3 Trunnion 4 P1 P2
Sling Length (m) 42 42 43 43 35 35
MBL of Sling (MT) 2592 2592 1418 1418 3060 3060
Sling Angle (deg) 73.8 73.8 61.1 61.1 64.7 64.7
Sling Tension (MT) 534.8 514.3 222.9 230.2 442.6 461.1
Shackle SW L(MT) - - - - 1000 1000
FOS for Sling1) 4.8 5 6.4 6.2 6.9 6.6
FOS for Shackle2) - - - - 2.3 2.2

Note 1) the FOS of sling shall not be less than 4.0.


Note 2) the FOS of sling shall not be less than 1.0.

Jacket Upending Data Summary

Horzontal Sling Load (MT) Main Upending Sling Loa


Step No Hook
Trunnion 1 Trunnion 2 Trunnion 3 Trunnion 4 Load (MT) P1
1 8 33 71 106 204 71
2 0 0 96 161 246 143
3 0 0 113 207 306 174
4 0 0 115 210 311 147
5 0 0 0 0 0 100
6 0 0 0 0 0 0
Topside
P3 P4
33 33
5184 5184
73.5 73.5
947.5 890
1550 1550
5.5 5.8
1.6 1.7

Topside
P3 P4
33 33
5184 5184
73.5 73.5
946 910.1
1550 1550
5.5 5.7
1.6 1.7

ummary
Jacket
Upending Sling Load (MT) Aux Hook Pitch
P2 P3 P4 Load (MT) Angle
(Deg)
0 0 12 83 5.45
0 0 54 195 35.07
0 0 52 225 55.72
0 0 57 202 76.52
154 163 109 511 87.62
0 0 0 0 90