The document outlines the spaces, intended users, and key details for 4 movie house cinemas within a shopping mall building. Each cinema includes a foyer, cinema hall, stage, seating area, common toilet, and projection area control room. Standard features across cinemas include open planning, mechanical ventilation and lighting. Total approximate areas for each cinema range from 729 to 1,059 square feet.
The document outlines the spaces, intended users, and key details for 4 movie house cinemas within a shopping mall building. Each cinema includes a foyer, cinema hall, stage, seating area, common toilet, and projection area control room. Standard features across cinemas include open planning, mechanical ventilation and lighting. Total approximate areas for each cinema range from 729 to 1,059 square feet.
The document outlines the spaces, intended users, and key details for 4 movie house cinemas within a shopping mall building. Each cinema includes a foyer, cinema hall, stage, seating area, common toilet, and projection area control room. Standard features across cinemas include open planning, mechanical ventilation and lighting. Total approximate areas for each cinema range from 729 to 1,059 square feet.
SPACE PRIMARY NO. OF QUALITATIVE FURNITURE, SPACE APPROX.
USERS USERS ANALYSIS FIXURES, AREA EQUIPMENT Open planning, Atria Building 400 lighted and mech, Indoor Garden 0.7 2.80 Users vent formal Open planning, Lavatory, Water Public Building 20 lighted and natural closet, Bidet, Urinal 1.67 33.4 Toilet Users vent hygienic Open planning, Activity Building 500 lighted and mech, Chairs, 2.8 1400 Center Users vent formal Tables Open planning, Elevator Building 20 per articially lighted and 6.75 135 Users car mech vent, formal Lift
2.408.10 TOTAL +30% of Circulation Access: 3,130.62
SHOPPING MALL ADMINISTRATION
SPACE PRIMARY NO. OF QUALITATIVE FURNITURE, SPACE APPROX.
USERS USERS ANALYSIS FIXURES, AREA EQUIPMENT Head Admin Manager, 2 Open planning, Sofa, Chairs 6.13 12.26 Office Employees lighted and mech, Comp. desk, Visitor vent formal Cabinet Mall Mall Manager Manager, 2 Open planning, Sofa, Chairs 5.1 10.2 Office Secretary lighted and mech, Comp. desk, vent formal Cabinet
Marketing Marketing 12 Open planning, Sofa, Chairs 4.18 50.16
Department Staff lighted and mech, Comp. desk, vent formal Cabinet
HR HR 8 Open planning, Sofa, Chairs 4.18 33.4
Department Department lighted and mech, Comp. desk, Staff vent formal Cabinet
Accounting Accounting 15 Open planning, Sofa, Chairs 4.18 62.72
Department Staff lighted and mech, Comp. desk, vent formal Cabinet
Treasury Treasury 4 Open planning, Sofa, Chairs 4.18 16.72
Department Department lighted and mech, Comp. desk, Staff vent formal Cabinet Leasing Leasing Department 14 Open planning, Sofa, Chairs 4.18 58.52 Department Staff lighted and mech, Comp. desk, vent formal Cabinet Open planning, peration Operation 14 lighted and mech, Sofa, Chairs 4.18 58.52 Department Staff vent formal Comp. desk, Cabinet Open planning, Conference Employees 12 lighted and mech, Chairs, 1.4 16.8 Room Staff vent formal Cabinet Authorized Open planning, Archive Person by 2 lighted and mech, Cabinet 1.67 10.04 Room Department vent informal
SHOPPING BUILDING MOVIE HOUSE CINEMA 1
SPACE PRIMARY NO. OF QUALITATIVE FURNITURE, SPACE APPROX.
USERS USERS ANALYSIS FIXURES, AREA EQUIPMENT Open planning, Foyer Building 500 lighted and mech, - 0.65 325 Users vent formal Open planning, Box Booth 4 lighted and mech, - 14 5.6 Office/Ticket Attendance vent formal Booth Building Open planning, Cinema 1 Users, 600 lighted and mech, - 0.65 390 Maintenance vent formal personnel Open planning, Stage Artist 10 lighted and mech, - 0.65 6.5 vent formal Open planning, Seating Area Building 500 lighted and mech, Chairs 0.6 300 Users vent formal Closed Common Building 9 planning, lighted Lavatory, water 1.67 15.03 Toilet Users and mech, vent closet, bidet, Hygienic Urinal Projection Authorized Open planning, Chairs, tables, Area Control Personnel 3 lighted and mech, Camp. desk 5.9 17.83 Room Utility vent semi- formal 1,059.96 Total + 30% of Circulation Access
SHOPPING BUILDING MOVIE HOUSE CINEMA 2
SPACE PRIMARY NO. OF QUALITATIVE FURNITURE, SPACE APPROX.
USERS USERS ANALYSIS FIXURES, AREA EQUIPMENT Open planning, Cinema 2 Building 600 lighted and mech, - 0.65 390 Users vent formal Open planning, Stage Artist 10 lighted and mech, - 0.65 6.5 vent formal Open planning, Seating Area Building 500 lighted and mech, Chairs 0.6 300 Users vent formal Closed Common Building 9 planning, lighted Lavatory, water 1.67 15.03 Toilet Users and mech, vent closet, bidet, Hygienic Urinal Projection Authorized Open planning, Area Control Personnel 3 lighted and mech, Chairs, tables, 5.9 17.83 Room Utility vent formal Camp. desk 729.36 Total + 30% of Circulation Access SHOPPING BUILDING MOVIE HOUSE CINEMA 3
SPACE PRIMARY NO. OF QUALITATIVE FURNITURE, SPACE APPROX.
USERS USERS ANALYSIS FIXURES, AREA EQUIPMENT Open planning, Cinema 3 Building 600 lighted and mech, - 0.65 390 Users vent formal Open planning, Stage Artist 10 lighted and mech, - 0.65 6.5 vent formal Open planning, Seating Area Building 500 lighted and mech, Chairs 0.6 300 Users vent formal Closed Common Building 9 planning, lighted Lavatory, water 1.67 15.03 Toilet Users and mech, vent closet, bidet, Hygienic Urinal Projection Authorized Open planning, Area Control Personnel 3 lighted and mech, Chairs, tables, 5.9 17.83 Room Utility vent formal Camp. desk 729.36 Total + 30% of Circulation Access SHOPPING BUILDING MOVIE HOUSE CINEMA 4
SPACE PRIMARY NO. OF QUALITATIVE FURNITURE, SPACE APPROX.
USERS USERS ANALYSIS FIXURES, AREA EQUIPMENT Open planning, Cinema 4 Building 600 lighted and mech, - 0.65 390 Users vent formal Open planning, Stage Artist 10 lighted and mech, - 0.65 6.5 vent formal Open planning, Seating Area Building 500 lighted and mech, Chairs 0.6 300 Users vent formal Closed Common Building 9 planning, lighted Lavatory, water 1.67 15.03 Toilet Users and mech, vent closet, bidet, Hygienic Urinal Projection Authorized Open planning, Area Control Personnel 3 lighted and mech, Chairs, tables, 5.9 17.83 Room Utility vent formal Camp. desk 729.36 Total + 30% of Circulation Access SHOPPING MALL: BUILDING MANAGEMENT AREA
SPACE PRIMARY NO. OF QUALITATIVE FURNITURE, SPACE APPROX.
USERS USERS ANALYSIS FIXURES, AREA EQUIPMENT
Engineering Engineers, 3 Open planning, Chair, Camp. 7.5 22.5
Office Allied lighted and mech, Desk Professional vent informal
Security Guard 25 Open planning, Chair, Camp. 1.6 40
Office Authorized lighted and mech, Desk, Locker Personnel vent informal
Main Electrician, 2 Open planning, 9 18
Electrical Utility lighted and mech, Chair, Camp. Room vent informal Desk, Locker Utility AHU and Technician 2 Open planning, 16 32 Control room AHU lighted and mech, Chair, Camp. Personnel vent informal Desk, Locker
BMS Room Building 3 Open planning, Chairs, tables, 5.1 15.3
Managemen lighted and mech, Camp. desk t vent informal t-staff Open planning, Mechanical Mechanical 2 lighted and mech, Chair, Camp. 16 3.2 Room Technician vent informal Desk Utility Open planning, Generator Utility 2 lighted and mech, Chair, Camp. 16 3.2 Room vent informal Desk Staff Open planning, Lounge Staff 5 lighted and mech, Chair, Locker 0.65 3.25 vent formal Open planning, Maintenance Authorized 4 lighted and mech, - 0.65 2.6 Crew Lounge Personnel vent formal
PERFORMANCE HALL CONCERT HALL
SPACE PRIMARY NO. OF QUALITATIVE FURNITURE, SPACE APPROX.
USERS USERS ANALYSIS FIXURES, AREA EQUIPMENT Open planning, Lobby Building 100 lighted and mech, - 0.65 65 Users vent formal Closed planning, Admin Area General 15 lighted and mech, Chair, Camps. 3.9 58.5 Manager vent formal Desk, table Employees Open planning, Seating Area Building 3800 lighted and mech, Chair .6 2300 Users vent formal Open planning, Stage Performers Varies lighted and mech, - 1 50 vent formal Closed Change Room Performers 10 planning, lighted - 1.2 12 and mech, vent formal Closed Common Building 12 planning,lighted Lavatory, water 1.67 20.4 Room Users and mech, vent closet, bidet, hygenic Urinal
Storage and Authorized 2 Closed - 8 16
Utility Area Personnel planning, lighted and mech, vent informal Total + 30% of Circulation Access 2800
SHOPPING MALL MAJOR TENANTS
SPACE PRIMARY NO. OF QUALITATIVE FURNITURE, SPACE APPROX.
USERS USERS ANALYSIS FIXURES, AREA EQUIPMENT Open Book Store Customer & Varies planning,lighted Food Rocks 550 Employees and mech, vent formal Open planning, Drug Store Customer & lighted and mech, Food Rocks 353.62 Employees Varies vent formal Open planning, Hardware Customer & Varies lighted and mech, Food Rocks 257.56 Store Employees vent formal Open planning, Furniture Customer & Varies lighted and mech, Food Rocks 1200 Store Employees vent formal Open planning, Food Stall, Dine in Varies lighted and mech, Kitchen sinks 2691.62 Restaurant Costumers vent formal range, Chairs Staff & cheff table Open Clothing Lines Sale Staff Varies planning, lighted Shelves, 4732.85 and mech, vent mannecuirist, Formal clothes panel Open planning, Spa Sale Staff Varies lighted and mech, 323.5 vent formal Spa equipment. Sinks, cart/cabinet Open planning, Salon Sale Staff, Varies lighted and mech, Salon Equipment 180 Beauticians vent formal Total + 20% of Circulation Access