You are on page 1of 2

BUP Series U-Shaped type

Reinforced plastic case U-Shaped type (A)


Photo
electric
sensor

(B)
Features Fiber
optic
sensor
● Improved noise resistance to disturbance light
● High speed response type (C)
Door/Area
● Reverse power polarity and short-circuit sensor

(Overcurrent) protection circuit (D)


● Light ON / Dark ON Selectable by control wire Proximity
sensor
● Protection structure IP66(IEC standard)
: BUP-30, BUP-50 (E)
Pressure
sensor

Please read “Caution for your safety” in operation (F)


Rotary
manual before using. encoder

(G)
Connector/
Socket

Specifications (H)
Temp.
controller
NPN open collector output BUP-30 BUP-30S BUP-50 BUP-50S
Model
(I)
PNP open collector output BUP-30-P BUP-30S-P BUP-50-P BUP-50S-P SSR/
Power
Sensing type Through-beam controller

Opaque materialsof min. Opaque materialsof min. Opaque materialsof min. Opaque materialsof min.
Sensing target (J)
ø4mm ø1.5mm ø4mm ø1.5mm Counter

Operation mode Selectable Light ON or Dark ON by control wire


Sensing distance 30mm 50mm (K)
Timer
Response speed Max. 1ms
Power supply 12-24VDC ±10%(Ripple P-P : Max. 10%) (L)
Panel
meter
Current consumption Max. 30mA
Light source Infrared LED(940nm) (M)
Tacho/
Speed/ Pulse
Sensitivity adjustment Fixed Adjustment VR Fixed Adjustment VR meter

NPN or PNP open collector output (N)


Control output ●Load voltage : Max. 30VDC ●Load current : Max. 200mA Display
unit
●Residual voltage - NPN : Max. 1V, PNP : Max. 2.5V
Protection circuit Reverse polarity protection, Output short-circuit protection (O)
Sensor
Indication Power indicator : green LED, Operation indicator : red LED controller

Insulation resistance Min. 20MΩ(at 500VDC megger) (P)


Switching
Noise strength ±240V the square wave noise(pulse width: 1㎲) by the noise simulator mode power
supply

Dielectric strength 1,000VAC 50/60Hz for 1 minute (Q)


Stepper
Vibration 1.5mm amplitude or 300m/s2 at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hours motor&
Driver&Controller
Shock 500m/s²(approx. 50G) in each of X, Y, Z directions for 3 times
(R)
Graphic/
Ambient illumination Sunlight : Max. 11,000㏓ Incandescent lamp : Max. 3,000㏓(Receiving illumination) Logic
panel
Environment Ambient temperature -25 to 65℃[BUP-30S(-P) & BUP-50S(-P) : -10 to 60℃], storage : -25 to 70℃
(S)
Ambient humidity 35 to 85%RH, storage : 35 to 85%RH Field
network
device
Protection IP66(IEC standard) IP50(IEC standard) IP66(IEC standard) IP50(IEC standard)
Material Case: ABS, Cap: PC (T)
Software
ø4, 4-wire, Length : 2m
Cable
(AWG22, Core diameter : 0.08mm, Number of cores : 60, Insulation out diameter : ø1.25)
(U)
Accessory - VR adjustment driver - VR adjustment driver Other

Approval
Unit weight Approx. 90g Approx. 140g
※The temperature or humidity mentioned in Environment indicates a non freezing or condensation environment.

A-65
BUP Series

Control output diagram


● NPN open collector output ● PNP open collector output
Photoelectric sensor circuit Connection Photoelectric sensor circuit Connection
(Brown)+V (Brown)+V
Light ON Light ON
Load 1.5Ω
Overcurrent
(Black) Output protection Max. 200mA
+ 12-24VDC + 12-24VDC

Main circuit
Main circuit

Max. 200mA - ±10% (Black) Output - ±10%


Overcurrent
protection
1.5Ω Load
(Blue)0V Dark ON (Blue)0V Dark ON

(White) Control (White) Control

※Select Light ON / Dark ON by control wire. - Light ON : Connect control wire to +V / Dark ON : Connect control wire to 0V

Operation mode
Operation mode Light ON Dark ON
Received light Received light
Receiver operation
Interrupted light Interrupted light
Operation indicator ON ON
(red LED) OFF OFF
ON ON
Transistor output
OFF OFF

Dimensions (unit: mm)

● BUP-30, BUP-30-P, BUP-30S, BUP-30S-P ● BUP-50, BUP-50-P, BUP-50S, BUP-50S-P


52 78.5
30 50

Optical axis Optical axis


Sensitivity VR
Operation Sensitivity VR
indicator Operation
41.6
36

Power indicator
78.1
indicator Power
72

indicator
26.9
26.8

6
6

2-ø6.4 11 2-ø6.4
66 Cable ø4, 2m 11
40 Cable ø4, 2m 20
20
20
20

9
9

※Please assemble screws M5 with 32 2-M8 Bolt ※Please assemble screws M8 with
16 2-M5 Bolt max. 20kgf·cm of tightening torque. max. 50kgf·cm of tightening torque.

Connections Mounting and sensitivity adjustment


Light ON / Dark ON Check the position where the photoelectric sensor will be
(Brown)+V used and the connection then supply the power and set
Light ON sensitivity as below.
※1 Load
+ When place a target within ● BUP-30S, BUP-30S-P
12-24VDC
(Black) Output
- sensing range of sensor, turn BUP-50S, BUP-50S-P
the VR from the minimum Sensing area
B Optimal
※2 Load position and check the position position
A
(Blue)0V
Dark ON
‘A’ where the operation
Non sensing
(White) Control indicator is turned on (Dark area
ON) or turned off (Light ON). Min. Max. C
※1: Load connection for NPN open collector output Turn the VR to ‘B’ in the middle
※2: Load connection for PNP open collector output between ‘A’ and ‘C’ which is the maximum sensitivity
position, this will be the optimal sensitivity position.
(The operation indicator is able to be operated where the
lowest sensitivity position.)

A-66