M 4 N N DV 1 N (I)
SSRs / Power
N Indicator (without output function) Controllers
Control output
1 NPN open collector output
2 PNP open collector output (J)
Power supply Counters
1 5-24VDC
DV DC Voltage (minus input)
(K)
Input type DA DC Current (minus input) Timers
AV AC Voltage
AA AC Current (L)
Type Panel
N New Type Meters
Size
N DIN W48×H24mm (M)
Digit Tacho /
4 9999 (4digit) Speed / Pulse
Item Meters
M Multi Meter
(N)
Display
Units
(S)
Field
●Bracket
60.3
42
●Panel cut-out (T)
Software
50.5 Transistor
48 Min. 50
4 output terminal
22.2 +0.3
0
28.8
36.3
22
21.8
Min. 37
24
45 +0.6
0
45.2
1.7
48.6
※Indicator model (M4NN- -1N) does not have transistor output terminal.
L-5
M4NN Series
Specifications
Model M4NN-DV-1 M4NN-DA-1 M4NN-AV-1 M4NN-AA-1
Input DC voltage DC current AC voltage, frequency AC current, frequency
-110 to 110% of the rated measurement input range Approx. 110% of the rated measurement input range
Max. allowable input (when not using minus input: -10 to 110%)
Power supply 5-24 VDC
Allowable voltage range 90 to 110% of the rated voltage (5V is fixed for lower limit)
Power consumption Max. 3W
Display method 7 segment LED Display (red), character height: 11mm
•23℃±5℃-DC Input: ±0.1% F.S. ±2digit / AC Input ±0.3% F.S. ±3digit
※For 5A terminal of M4NN-DA, AA Input, ±0.3% F.S. ±3digit
Display accuracy
•-10 to 50℃-DC/AC Input: ±0.5% F.S. ±3digit / Frequency: ±0.5% F.S. ±3digit
※For 5A terminal of M4NN-DA, AA Input, ±1% F.S. ±3digit
Display cycle 0.1 to 5.0 sec. (selectable by 0.1 sec.)
A/D conversion method Practical oversampling using successive approximation ADC
Sampling cycle 50ms (resolution 1/12,000) 16.6ms (resolution 1/12,000)
Max. display range -1999 to 9999 (4 digit)
NPN/PNP open collector output:
Preset output※1 ·Load voltage: max. 30VDC ·Load current: max. 100mA
·Residual voltage: max. 1VDC (NPN), max. 2VDC (PNP)
AC measurement※2 - Average value (AVG) measurement
Measurement range: 0.100 to 9999Hz
Frequency measurement ※2 - (variable by decimal point position)
Insulation resistance Min. 100㏁ (at 500VDC megger)
Dielectric strength 2,000VAC for 1 min. (between all terminals and case)
Noise resistance ±2kV the square wave noise (pulse width: 1㎲) by the noise simulator
Mechanical 0.75mm amplitude at frequency of 10 to 55Hz (for 1 min.) in each X, Y, Z direction for 2 hours
Vibration
Malfunction 0.5mm amplitude at frequency of 10 to 55Hz (for 1 min.) in each X, Y, Z direction for 10 min.
Mechanical 100m/s2 (approx. 10G) in each X, Y, Z direction for 3 times
Shock
Malfunction 300m/s2 (approx. 30G) in each X, Y, Z direction for 3 times
Environ- Ambient temperature -10 to 50℃, storage: -20 to 60℃
ment Ambient humidity 35 to 85%RH, storage: 35 to 85%RH
Connection Plug/Socket terminal block (accessory)
Double insulation or reinforced insulation
Insulation type (mark: , dielectric strength between the measured input part and the power part: 1kV)
Approval
※3 Approx. 83.6g Approx. 83.7g Approx. 83.8g Approx. 83.8g
Weight (approx. 46.8g) (approx. 46.7g) (approx. 46.9g) (approx. 46.9g)
※1: Indicator (M4NN- -1N) model does not have output function. ※2: AC, frequency measurement functions are only for AC measurement type.
※3: The weight includes packaging. The weight in parentheses is for unit only.
※Environment resistance is rated at no freezing or condensation.
Connections
● M4NN-DV-1 ● M4NN-DA-1
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
DC ±1V DC ±10mA
/±200mV - + + - /±2mA - + + -
DC±10V/±2V DC±100mA
HOLD SOURCE /±20mA HOLD SOURCE
DC ±100V/±20V /4-20mA
5-24VDC 5-24VDC
DC ±600V/±200V DC ±1A/200mA
DC ±5A/±2A
● M4NN-AV-1 ● M4NN-AA-1
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
AC 2V/1V AC100mA
- + + - - + + -
/AC50mA
AC 20V/10V
AC500mA
HOLD SOURCE /AC250mA HOLD SOURCE
AC 110V/50V
5-24VDC AC 1A 5-24VDC
AC 600V/200V
AC 5A/2.5A
● NPN Open Collector
※Input and output are insulated from the power.
11 12 13 14
11 12 13 14
1 2 3 4 5 6 7 8 9 10
OUT1 GO OUT2 COM
L-6
Small Multi Panel Meter
RUN mode
(B)
Fiber
Optic
M M for 2 sec. M Sensors
for 3 sec.
(C)
Door/Area
Sensors
PA0 PA1
M M for 2 sec. (D)
Proximity
Sensors
PA2
(E)
Pressure
M for 3 sec. Sensors
Parameter 1 group
(F)
Parameter setting Rotary
Encoders
1. Each parameter alternately displays parameter name and the SV in 0.5 sec.
RUN mode 2. Press the M key and the SV is saved and it moves to next parameter. (G)
3. If there is no operation for 60 sec., it returns to RUN mode automatically. Connectors/
Sockets
M 3 sec. M 2 sec. 4. Press the M keys for 3 sec. and it returns to RUN mode.
5. Press the , keys to change the SV at the parameter.
(H)
( : moves setting digit, : changes set value) Temperature
※ S : Press any key between , . Controllers
M (J)
Counters
(L)
S S S
DISP STND SCAL DC voltage/current
Panel
Meters
AC voltage/current
M M M
(M)
Tacho /
Display
Decimal point position Speed / Pulse
method DOT Set range: FREQ Frequency PF Power
factor
Meters
Low-limit scale
L-SC ※
value 1 Mantissa of gradient
(P)
M
INbH correction for frequency L-RG Low-limit
input
※1
Switching
Mode Power
Supplies
Set range of mantissa:
M
M )100 to (999 (Q)
Stepper Motors
S Deviation correction of high limit & Drivers
(T)
Factory default Software
Parameter M4NN-DV M4NN-DA M4NN-AV M4NN-AA Parameter M4NN-DV M4NN-DA M4NN-AV M4NN-AA
IN-R 600V 5A 600V 5A INbH !000 !000 !000 !000
MINU ON ON - - INbL 00 00 00 00
DISP STND STND STND STND H-RG 600 %00 - -
DOT 0 0 0 0 L-RG -600 -%00 - -
H-SC 600 500 600 5000 INbE - - 10 0 10 0
L-SC -600 -500 0 0
L-7
M4NN Series
S Preset output operation mode of OUT1 (displayed only for OUT 1 output model)
OU!T OFF Set range: OFF, HI, LO, HL, HL-G
M M
S Preset output operation mode of OUT2 (displayed only for OUT 2 output model)
OU@T OFF
M
S
Preset hysteresis of OUT1
HYs1 001 Set range: within 10% of max. display range (unit: digit)
If display resolution is over 10000, it is fixed as 999.
M
※When OU!T parameter is OFF, it is not displayed.
S
Preset hysteresis of OUT2
HYs2 001 Set range: within 10% of max. display range (unit: digit)
M
If display resolution is over 10000, it is fixed as 999.
※When OU@T parameter is OFF, it is not displayed.
S Monitoring delay time of peak monitoring function
PEkT 00 5 Set range: 00 to 30 sec.
M
OFF Unlock
S Display cycle
PEkT )2 5 Set range: 0.1 to 5.0 sec.
LOC1 Lock Parameter 1 group
M LOC2 Lock Parameter 1, 2 groups
LOC3 Lock Parameter 0, 1, 2 groups
Lock among 4 types.
LOC S
OFF Set range: OFF, LOC1, LOC2, LOC3
M
Factory default
Parameter M4NN-DV M4NN-DA M4NN-AV M4NN-AA Parameter M4NN-DV M4NN-DA M4NN-AV M4NN-AA
※1
OU!T OFF OFF OFF OFF PEkT 00 5 00 5 00 5 00 5
※1
OU@T OFF OFF OFF OFF DIsT )2 5 )2 5 )2 5 )2 5
※1
HYs1 - - - - LOC OFF OFF OFF OFF
※1
HYs2 - - - -
※It is not displayed for the indicator model.
Parameter 0 group
RUN mode
L-8
Small Multi Panel Meter
Factory default (A)
Photoelectric
Parameter M4NN-DV M4NN-DA M4NN-AV M4NN-AA Parameter M4NN-DV M4NN-DA M4NN-AV M4NN-AA Sensors
※1 ※1
OU!H 600 %00 60)0 %000 OU@L -600 -%00 00)0 )000 (B)
※1 ※1 Fiber
OU!L -600 -%00 00)0 )000 hPEK 0 )00 )0 )000 Optic
※1 ※1 Sensors
OU@H 600 %00 60)0 %000 lPEK 0 )00 )0 )000
※It is not displayed for the indicator model. (C)
Door/Area
Sensors
(D)
(E)
Type Measured input range Input impedance Display range [ STND] Note Pressure
Sensors
0-2.5A [@5A] 0.01Ω 0.000 to 2.500 440V is displayed automatically & Controllers
L-9
M4NN Series
Functions Initialization
Minus input display [PA 1 group: MINU] RUN mode
●When minus input is unnecessary, or when display 0 not M+ + for over 5 sec.
to display minus input due to display minus input due
to unstable input value around 0, set as this minus INIT NO YES
input display function. M M
●When setting OFF, low-limit value of input range is set 0 0000
and it displays minus input as 0. ※Flashes
M4NN-DV/AV 600V
●The low-limit value of L-SC, OU .L, L-RG parameters twice in
is changed based on "0". order
M4NN-DA/AA SA and it is
Min. display value is "0" and H-SC, H-RG parameters
initialized
display max. value of the input range. STND
The INbH / INbL / OU .T / HYS. / OU .H parameters
are initialized to factory default.
※In case of DC current measurement input model, when Error display
measurement input range [IN-R] is set as 4-20, this Display Description
parameter is not displayed. Flashes when measured input is exceeded the max.
HHHH
allowable input (+110%)
AC frequency measurement Flashes when measured input is exceeded the min.
LLLL
[PA 1 group: DISP ] allowable input (minus input ON: -110%, OFF: -10%)
It measures input signal frequency when it is an AC input. D-HH
Flashes when display input is exceeded max. display
It uses fixed decimal point by DOT parameter setting of range (9999)
parameter 1 group, measured range can be changed by D-LL
Flashes when display input is exceeded min. display
setting and measured range of decimal point position is range (-1999)
as below chart. It is available to adjust upper gradient F-HH
Flashes when input frequency is exceeded the max.
at INbH and INbE of parameter 1 group. In order to measured range (10kHz) and display range (9999)
measure frequency normally, input signal, over 10% F.S. PF-H
Flashes when power factor display value to measured
of the measured range, should be supplied. Please select input is over than LAG 0.50
the proper point of measurement terminal. Flashes when power factor display value to measured
PF-L
●Measurement range input is less than LEAD -0.50
Dot position )000 )00 )0 0 ※Error is cleared when the input value is within
Measurement 0.100 to 0.10 to 0.1 to measurement range or display range.
1 to 9999Hz
range 9.999Hz 99.99Hz 999.9Hz
※Accuracy of frequency measurement: Below 1kHz, F.S. Display cycle delay[PA 2 group: D1sT]
±0.1rdg ±2digit, from 1 to 10kHz, F.S. ±0.3 rdg ±2digit In some applications the measured input may fluctuate
●INbH: 0.100 to 9.999 which in turn causes the display to fluctuate. By adjusting
[gradient adjustment of high-limit value] the display cycle delay function time at D1sT of parameter
-2 -1 0 1
●INbE: 10 , 10 , 10 , 10 [index adjustment of INbH] 2 group, the operator can adjust the display time within
a range of 0.1 sec to 5 sec. For example, if the operator
Zero adjustment [low-limit display value sets the display cycle time to 4.0 sec., the display value is
deviation correction] displayed the averaged input value over 4 sec. in every 4
Forces the display value of measured input to 0 (Zero). sec.
• Zero adjustment range: -99 to 99
• Zero adjustment method: Press and key in RUN Monitoring max./min. display value
mode for 3 sec. [PA 0 group: hPEK/lPEK, PA 2 group: PEkT]
It monitors Max./Min. value of display value based on
+ for 3 sec.
current display value and then display the data in hPEK,
)15 )00 lPEK of parameter 0 group. Set delay time (0 to 30
sec.) in PEkT mode of parameter 2 group in order to
When zero point adjustment with front key and hold terminal avoid caused by initial overcurrent or over voltage, when
is finished normally, zero point of measurement terminal monitoring the peak value. Delay time is 0 to 30 sec. and it
is displayed and the adjusted value is saved in INbL starts to monitor the peak value after set time.
automatically. When , keys are pressed at hPEK, lPEK mode of
※If zero adjustment range is exceeded, the error[OVER] parameter 0 group, it will be initialized.
flashes twice and then move to RUN mode, maintaining ※hPEK, lPEK parameters is not displayed when
previous setting value. monitoring delay time [PEkT] of parameter 2 group is
set as 00 sec.[00 S].
L-10
Small Multi Panel Meter
Error correction[PA 1 group: INbH / INbL] E.g. 2) Display scale setting [L-SC/H-SC]and gradient (A)
It corrects display value error of measurement input. adjustment [INbH] (AC input) Photoelectric
Sensors
INbL: -99 to 99 (adjust deviation of low-limit value), ①When the measured input AC 2.000V at the input range
AC 0 to 5.000V and it displays %000, set decimal point
INbH: 0.100 to 9.999 (correct gradient of high-limit value) (B)
position [DOT] as )000 before setting the scale value. Fiber
Display value= (measured value × INbH) + INbL Optic
②When the measured input is AC 2.000V in order to Sensors
E.g.) When the measured range is 0 to 500V, and the
display %000, 12.500 should be displayed when max.
display range is 0 to 500.0. If the low display value is (C)
input value is 5.000V. However, it cannot set because the Door/Area
!2 to 0V input, set -12 as INbL value to display 0.0 Sensors
max. set value is 9.999.
by adjusting offset of the low-limit value. The display Set as Gradient correction set value [INbH] × High scale (D)
value to 500V measured input varies by adjusting the value[H-SC] = 12,500 as the following table. Proximity
Sensors
offset of low-limit value. If this display value is 50!0, ③After this setting is finished, it displays %000 when the
calculate 500.0/501.0 (desired display value/the measured input is 2.000V. (E)
display value), and set the )998 correction value as Pressure
H-SC L-SC INbH Note Sensors
the INbH to display 50)0 by adjusting gradient of Unavailable to set because max.
high-limit value. 12.500 0.000 1.000 set value of H-SC is (999 (F)
※The offset correction range of INbL is within -99 to 99 6.250 0.000 2.000
Rotary
Encoders
for D-0, D-1 digit regardless of decimal point position [DOT]. In this case, any setting methods
3.125 0.000 4.000
※High limit error correction function is available as display the same display value. (G)
2.500 0.000 5.000 Connectors/
“Gradient correction function”and low limit error Sockets
measured input
This function is to adjust gradient of standard display value (I)
SSRs / Power
or scale value for the input value within the measured input Controllers
range. By adjusting gradient, it is available as “High limit 5.000
error correction function”. (J)
As the below (figure 1), in case of display gradient 1 for Input Counters
value
the measured input 100V, this function is to adjust display
2.000V 5.000V
value by adjusting the gradient as 1.5 times or 0.5 times. (K)
Timers
• Set range: 0.100 to 9.999, E.g. 3) Display scale setting [L-SC/H-SC] and gradient
Factory default: 1.000 (unit: multiply) adjustment [INbH] (DC minus input)
(L)
E.g. 1) Gradient adjustment ①When the measured input DC -40mA at the input range Panel
①When the measured input is 100.0V in order to display DC -100.0 to 100.0mA and it displays `6)0, set decimal Meters
15)0, set gradient correction set value[INbH] as !500. point position[DOT] as )000 before setting the scale (M)
This value is also applied for minus input. When the value. Tacho /
Speed / Pulse
measured input is -100.0V, it displays -15)0. ②When the measured input is DC -40mA in order to Meters
②When the measured input is -100.0V in order to display display `6)0, -400.0 should be displayed when min. (N)
-5)0, set gradient correction set value[INbH] as )500. input value is -100.0mA. However, it cannot set because Display
Units
This value is also applied for plus input. When the the min. set value is -199.9.
measured input is 100.0V, it displays 5)0. Set as gradient correction set value[INbH]×low scale (O)
value [L-SC] =-400.0 as the following table. Sensor
Controllers
INbH Note
Set high-limit scale value as (- (L-SC)) value. If high
scale value is set at first, set low scale value as (- (H-SC)) (P)
※Shaded part of Figure 1 is not displayed for the below value. Switching
Mode Power
① !500 cases. ③After this setting is finished, it displays `6)0 when the Supplies
(Figure 1) -160.0
Display value for
measured input
-400.0
L-11
M4NN Series
Power factor (PF) display E.g. 3) When LEAD value is smaller than -0.90, LAG value
is smaller than 0.90, and OUT1 is used,
[PA 1 group: H-RG/ L-RG]
①Set OU!T as HL at parameter 2 group.
●This function displays LEAD and LAG by analog output
②Set OU!H as )90 and OU!L as -)90 at parameter 0 group.
signal from the power factor transducer. ※OU@T is also same setting as OU!T.
●It is available to accept several outputs of the power factor
transducer by high-limit[H-RG]/low-limit[L-RG] analog Output mode HL
LAG
output value setting in the power factor transducer. OU!Hvalue 0.90
0.5
Input value
LEAD LAG
L-12
Small Multi Panel Meter
Preset output mode [PA 2 group: OU!T/OU@T] (A)
Photoelectric
Mode Output mode Operation Sensors
(B)
OFF No output Fiber
Optic
OUT1 No output Sensors
OUT1.L
: Display value ≤ OU!L
LO (E)
Period OFF Pressure
OUT1 : Display value ≥ OU!L+ HYs1 Sensors
Period ON (F)
Rotary
OUT1.H : Display value ≤ OU!L or Encoders
OUT1.L
Display value ≥ OU!H
HL
Period OFF (G)
OUT1 : Display value ≥ OU!L+ HYs1 Connectors/
Sockets
or Display value ≤ OU!H- HYs1
Period ON (H)
Temperature
: Display value ≥ OU!L or Controllers
OUT1.H
Display value ≤ OU!H
OUT1.L
HL-G Period OFF (I)
: Display value ≤ OU!H- HYs1 SSRs / Power
OUT1 Controllers
or Display value ≥ OU!H+
HYs1
(J)
※Set output mode separately for each OUT1/OUT2. Counters
(N)
Display
Units
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
(S)
Field
Network
Devices
(T)
Software
L-13