You are on page 1of 6

FEATURE: VLSFOs - The Concerning Fuel Management Issues So

Far....
by Stanley George, Group Technical & Science Manager, Veritas Petroleum Services

Thursday January 23, 2020


 Share  
The introduction of Very Low Sulphur Fuel Oils (VLSFOs) for compliance with
IMO2020 has increased at a growing rate since October 2019. The chemistry and
nature of these new fuels indicates likely problems with cold‐flow properties,
stability, contamination, cat‐fines and sulphur content. In order to address cold‐flow
problems, VPS introduced a new Wax Appearance Temperature (WAT) in October
2019. This paper illustrates how WAT measurements can be used to avoid cold‐flow
and stability problems with VLSFOs. 3 recent case studies are used to exemplify the
catastrophic problems that can arise when using VLSFOs if precautionary
measurements are not taken.
WAT or cloud point is the temperature at which wax crystals appear when fuel is
cooled. This ultimately results in wax precipitation causing the fuel to stop flowing,
which has a detrimental impact on operability as it may block filters and pipes,
causing fuel starvation and engine problems. Providing that the fuel temperature does
not fall below the WAT it will not produce wax, so measuring this temperature is
critical in managing and mitigating risk.
At the time of writing, VPS has tested the WAT on more than 230 different VLSFOs
taken during bunkering from ports around the world. A summary of the results is
shown in the graph below.
Elevated WAT and WDT could result in wax formation unless the purifiers separation
temperatures are maintained above the WAT. If the fuel at any time during storage
and transfer has fallen below the WAT, then the fuel may have to be heated above the
WDT to melt away the wax formed when the temperature fell below the WAT.
As an average (October 2019 to December 2019) we noted a WDT 12°C above the
WAT. However, in a few cases the difference between WAT and WDT has been
above 30°C. The increase in the difference between the WAT and WDT could be an
indication of an increase in paraffin‐based oil within the blend.
Low viscosity and high WAT are the known recipe for difficulties in separation at the
purifiers. The most affected WAT related issues, as reported by the vessels, are with
fuels with a lower viscosity at a temperature mainly below 30o C, although the issues
were not isolated to low viscosity fuel oils.
Generally, purifier manufacturers, for the new type of VLSFO fuels recommend the
following separation temperatures for effective separation of water, catfines and other
solid contaminants.
Considering the above separation temperatures in line with the tested WAT and
viscosity, we have seen few instances when the recommended separation temperature,
based on viscosity (and 15oC + PP) is below the WAT, consequently resulting in
purifier issues such as excessive sludge formation or complete blockage in the worst
case.
The maximum temperature for effective separation is typically 98°C. From
experience it is known that separation is effective at this temperature. We have noted
that problems are aggravated when we have a low viscosity fuel (for example, <30
cSt) with high catfines (for example >40 ppm) and high WAT. It almost becomes
impossible to treat such fuel on board the vessel.
Reducing the separation temperature for low viscosity fuels not only reduces the
separation efficiency, hence does not remove the catfines to the required levels, but
also generates more sludge, especially when the WAT for that fuel is higher than the
maintained separation temperature.
In such cases we have noted that raising the separation temperature from 40oC to
>70oC, making sure that the purifier can cope with this increased temperature may
resolve the separation issues.
On the other hand, some of the VLSFO that are blended, are either already unstable or
on the verge of being unstable. Such fuels (which are on the verge of becoming
unstable) when heated, have a tendency to fall out, so the temperature has to be
reduced and maintained as per the above table. The Total Sediment Potential (TSP) of
the fuel when bunkered although within limits may show significantly higher TSP
when tested on a later date during consumption. The results are the consequence of
unstable blends.
Fuels received on board are not supplied for direct consumption without onboard
treatment. A great deal of associated risk of using the VLSFO on‐board vessels can be
managed contractually, by ordering the fuel that can be handled by the vessels
onboard treatment system. For this reason, it is essential for a supplier and the
recipient to know the properties of the fuel before supplying (Suppliers) and/or
consumption (End users). Testing the fuel before consumption has always been the
norm, however, this is now more critical than ever.
Case Study 1
On 27 October 2019, a Vessel loaded 100 MT of VLSFO at Antwerp. A continuous
drip sample was taken during bunkering and tested to ISO8217 and found to meet the
specification. However, when the vessel started consuming this fuel, the vessel
reported abnormal operation of the purifiers and blockage of filters. The fuel
throughput to the purifier had to be reduced due to sludging issues being experienced
at the purifiers. Consequently, the engine had to be operated at reduced load. During
this time, the vessel also experienced rough weather.
The Chief Engineer reported the problem to Veritas Petroleum Services (VPS) and
VPS carried out a detailed investigative analysis of the bunkered fuel sample. Test
results showed high WAT (69oC), WDT (>75oC), pour point (21oC) and catfines
(51ppm). No stability issues were noted (TSP=0.04%) and Gas Chromatography Mass
Spectrometry (GCMS) did not reveal presence of chemical contamination.
VPS advised the Chief Engineer to maintain purifier temperature at 98oC, further
reduce purifier throughput and reduce the discharge interval of the purifier, which
enabled the vessel to continue at low speed. Furthermore, the settling and service
tanks temperature were advised to be maintained above 69oC (WAT), this helped to
clear the filter blockage.
Had the bunkered fuel been tested for WAT/WDT, VPS could have provided the
above advise to the vessel prior to commencing usage of this fuel and help minimise
operational difficulties, potential damage to equipment's and loss of hire. The high
WAT in combination with high Catfines makes the onboard fuel oil treatment
difficult, if not impossible. Settling tanks are designed to perform a key role in
removing Catfines (and other solid contaminants) as the heavier particles settle over
time, provided the fuel is freely flowing. For effective settling, the Settling tank
temperature should always be maintained at or above the WAT. Similarly maintaining
the correct purifier temperature plays a major part in effective separation of the fuel.
Case Study 1 ‐ Details:
Typical properties of the fuel:
 Density: 967.4 kg/m3,
 Viscosity @ 50°C, 247.0 cSt,
 Sulphur: 0.47% (BDN)
On consumption, the vessel faced the following problems:
 Purifier abnormal operation noted
 Thick sticky sludge found in both the purifiers
 HFO transfer pump filter choked
 Various pipes, bowls and chambers blocked by thick deposits, (manually
cleared later)
 Main engine had to be operated at reduced load due to low fuel oil through
put from
 purifiers
Figure 1: Sludge deposit
Case Study 2
On 20 October 2019, a Vessel loaded >180 MT of VLSFO at Rotterdam. Immediately
on consumption of the fuel, the vessel experienced abnormal operation of the purifiers
and damage to its fuel pumps. It was also brought to VPS' attention that another vessel
which had bunkered the same fuel faced similar issues. A representative bunker
sample was analysed in one of the VPS laboratories and based on the test results of
the analysed sample, the fuel was certified to be within the ISO 8217 specification.
To identify the root cause, VPS carried out a detailed investigation and not only found
that the concerned fuel had a WAT of 57oC and a WDT of >75oC, but also the
GCMS test revealed presence of styrenic chemical contaminants. The TSP result of
the bunkered fuel was well within limits (<0.01%) and as such, no stability issues
were expected.
Low viscosity (32.6 cSt at 50oC) caused restrictions in heating the fuel to elevated
temperatures, whereas high WAT/WDT required the fuel to be heated to at least
above 58oC, or above 75oC if the temperature at any time during the storage had
fallen below 57oC, which was the case on this vessel. Furthermore, due to the type of
cargo the vessel was carrying there were restrictions in heating the bunker tanks to
above 50oC.
VPS advised that the fuel cannot be handled on board the vessel and cannot be used.
The fuel was debunkered.
Case Study 2 ‐ Details:
Typical properties of the fuel:
 Density: 903.0 kg/m3,
 Viscosity @ 50°C, 32.6 cSt
On consumption the vessel faced the following problems:
 Purifier abnormal operation noted
 Thick sticky sludge (resin type) found in both the purifiers and fuel system
 Fuel pump damage
 Another vessel that bunkered the same fuel has similar issues
Figure 2: Resin like sludge deposit
Case Study 3
On 14 December 2019, a vessel loaded >300 MT of VLSFO at Houston. This was the
second ever batch of VLSFO for the vessel. No issues were reported during the
consumption of the first batch which was bunkered at Las Palmas. Immediately on
consumption of the Houston fuel, the vessel reported clogging of both its purifiers. In
the first 24 hours the vessel cleaned both purifiers twice, being able to run one purifier
for only 6 hours. The bunker storage, settling and service tanks were emptied
completely and manual cleaning was carried out before taking the first stem of the
VLSFO at Las Palmas. It was reported that there could have been some amount of
comingling (about 1 m3) of the earlier VLSFO fuel with the new batch of Houston
VLSFO.
After 24 hours of consumption of the fuel, the operation could not be stabilised, the
vessel was unable to handle the situation and contacted VPS for expert advice.
VPS immediately carried out a systematic investigation of the events. VPS had tested
a representative bunker sample of the concerned fuel that was drawn by drip sampler
during the bunkering operation. The test results showed the fuel to be within the ISO
8217 specification.
Although additional tests where being carried out, the vessel required urgent advice to
keep the engines in operation. Based on the tested viscosity (13.14 cSt), VPS had
advised the purifier temperature of 40oC. VPS in discussion with the purifier
manufacturer requested the vessel to increase purifier temperature to 75oC. The
WAT/WDT in this case was 40oC/55oC.
The vessel reported improvement in the purifier operation for the first 4 days, but later
faced the same sludging issue. This time the sludge was harder than earlier.
The fuel sludge had started to fall out over the course of time and the vessel was
advised to keep the purifier throughput to minimum and reduce the discharge intervals
such that the fuel can be consumed slowly. A stabiliser (fuel additive) option was
considered as a standby but was not required.
Case Study 3 ‐ Details:
This Vessel loaded >300 MT of VLSFO at Houston on 14 Dec 2019.
Typical properties of the fuel (As per BDN):
 Density: 911.8 kg/m3,
 Viscosity @ 50°C, 14.0 cSt,
 Sulphur: 0.453% 
On consumption the vessel faced the following problems:
 Both purifiers clogging with 'fluffy" sludge blocking the sludge port'
 Resulting in low bowl speed of the purifier
 In first 24 hours, the cleaned each purifier 2 times. This gives a rate of clogging
of 1 purifier
 every 6 hours.
Notes:
The Bunker Storage, Settling and Service tanks were emptied completely, and manual
cleaning was carried out before initially taking the first stem of VLSFO. All sludge
was removed, without any traces of old fuel in the tank. There was no possibility of
mixing of HSFO with VLSFO.
The current fuel in use is the second batch of VLSFO that we loaded in Houston. First
Batch of VLSFO was loaded from Las Palmas and the vessel did not face any issues
with that batch of fuel.
The first stem that was loaded from Las Palmas (previous port) may have mixed with
VLSFO loaded in Houston; but it was less than 1.0 m3 of VLSFO which remains as
unpumpable. However, as per the compatibility report, both fuels were compatible
when tested.
Reportedly, no additives or stabilisers were used in any of the tanks.
Brief summary of actions taken on board the vessel:
Based on the tested viscosity (13.14 cSt) the temperature of 40oC was maintained at
the purifier inlet and inlet to engine at 60oC to achieve 11cSt for injection.
When purifier sludging and clogging of the filter was noted and reported, VPS
requested the vessel to increase the fuel oil temperature at the purifier inlet from 40oC
to 72oC, Settling tank to 60oC and storage tanks at 40oC. The vessel reported that a
temperature of 75oC was consistently maintained. The filter clogging and purifier
sludging issue appeared to stabilise.
Please find the below photos of accumulated sludge in the Purifier frame. The first
two photo was taken when the purifier was clogging every 6 hours during the first 24
hours of consumption.
After 4 days of operation the sludging problem resurfaced, but this time the sludge
was much harder than the first time. The purifier was getting clogged in the sludge
frame, outside the
bowl. Minimum flow over the purifiers and discharge interval to 15 minutes is all that
could be done to consume this fuel.
The symptoms are a typical incompatibility case, probably mixing of the VLSFOs in
the settling tanks.

You might also like