Professional Documents
Culture Documents
LX700
Important User Information ............................................................. 3
Safety Instructions ............................................................................ 4
Installation ......................................................................................... 5
Installation Dimensions ................................................................................... 5
Installation Location......................................................................................... 6
Installation Environment and Precaution ...................................................... 7
Mounting/Dismounting Module ..................................................................... 8
Wiring................................................................................................. 9
Power Supply Module Wiring ..................................................................... 9
Grounding....................................................................................................... 11
Operating Condition Setting .......................................................... 12
LX-CPU700p Processor Module.................................................................... 12
Input/Output Modules..................................................................... 14
Digital Input Module Specifications .......................................................... 15
Digital Relay Output Module Specifications ............................................. 16
Digital Transistor Output Module Specifications...................................... 17
Digital SSR Output Module Specifications ............................................... 17
Input/Output Module Wiring Diagrams......................................... 18
LX-X16D Wiring Diagram .............................................................................. 18
LX-X32D Wiring Diagram .............................................................................. 18
LX-X64D Wiring Diagram .............................................................................. 19
LX-X16A110 and LX-X16A220 Wiring Diagram .......................................... 19
LX-Y16R and LX-Y16RV Wiring Diagram ..................................................... 20
LX-Y32RV Wiring Diagram ............................................................................ 20
LX-Y16T Wiring Diagram............................................................................... 21
LX-Y32T Wiring Diagram............................................................................... 21
LX-Y16SSR Wiring Diagram.......................................................................... 22
Important User Information
Solid state equipment has operational characteristics differing from those of
electromechanical equipment. Because of this difference, and also because of the
wide variety of uses for solid state equipment, all persons responsible for applying
this equipment must satisfy themselves that each intended application of this
equipment is acceptable.
In no event will L&T be responsible or liable for indirect or consequential damages
resulting from the use or application of this equipment.
The examples and diagrams in this manual are included solely for illustrative
purposes. Because of the many variables and requirements associated with any
particular installation, L&T cannot assume responsibility or liability for actual use
based on the examples and diagrams.
No patent liability is assumed by L&T with respect to use of information, circuits,
equipment, or software described in this manual.
Reproduction of the contents of this manual, in whole or in part, without written
permission of L&T is prohibited.
Throughout this manual we use the following symbols to make you aware of safety
considerations.
Identifies information about practices or circumstances which may
WARNING
lead to serious personal injury or death, property damage, or
economic loss.
3
4
4
Safety Instructions
Please read this manual and the related documentation thoroughly and familiarize
yourself with product information, safety instructions and other directions before
installing, operating, performing inspection and preventive maintenance.
Please be aware that the instructions are marked with either a warning symbol or
attention symbol.
4
5
5
Installation
Installation Dimensions
LX700 PLC System Dimensions (mm)
A
B
TR OUT
TR OUT
TR OUT
TR OUT
TR OUT
DC IN
DC IN
DC IN
CPU750B
CP U
Progrmmable
Controller 115.5 118.5
OPEN
unit (mm)
111.0 Dimensions
Slot Type
A B
3-slot type 205.0 184.0
5-slot type 276.0 254.0
8-slot type 381.0 360.0
10-slot type 452.0 430.0
12-slot type 522.0 501.0
5.0 * 4
27.5
5
Installation Location
Be sure to maintain a sufficient distance from wiring ducts, and other machines
below and above the module for proper ventilation.
Do not install the modules stacked up or horizontally. Doing so will prevent proper
cooling of the module and cause overheating inside the PLC (programmable
controller).
Do not install the module above devices which generate heat such as heaters,
transistors or large scale resistors.
In order to eliminate any effects from noise emission, power wires and
electromagnetic devices should be kept at least 100 mm away from the surfaces of
the module. When installing the module behind the doors of the operation panel, be
especially careful to maintain these distances.
Programmable
Controller
OPEN
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
POWER
Duct
RS232C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
PROG
RMT
RUN
TEST
INIT
40 39
1
2 1 3940
1 2
Min. 50 mm
4039
40 39
1
40 39
1
2
2 1 3940
4039
TR OUT
TR OUT
CPU700p
DC IN
DC IN
DC IN
1 2
RUN COM1
40 39
PROG COM2
1
TEST ERROR
BATT
2
INIT
TEST
INIT
RUN
RMT
PROG
TEST
RS232C
20
19
18
17
16
15
14
13
12
10
11
9
8
7
6
5
4
3
2
1
RUN
RMT
PROG
POWER
Programmable
Controller
OPEN
20
19
18
17
16
15
14
13
12
10
11
9
8
7
6
5
4
3
2
1
COM 1
RS232C
RS485
COM 1
RS232C
RS485 POWER
20 20
19 19
40 39 40 39 4039
1 2
18 18 INIT
17 17 RS232C
TEST 1 1
16 16 RUN 40 39 1 2 1 2 1 2
15 15 RMT 2 2
14
13
12
14
13
12
OPEN
LX
Programmable
PROG
3
4
5
6
3
4
5
6
11 11
Min. 50 mm
10 10 Controller 7 7
8 8
9 9
9 9
8 8 10 10
7 7 Controller
11 11
6 6 Programmable 12 12
5 5
13 13
4 4 14 14
PROG
3 3 OPEN 15 15
2 2 RMT
RUN 16 16
1 1 RS232C 17 17
2 1 2 1 2 1 3940 TEST
18 18
INIT 19 19
2 1 39 40 39 40 39 40 20 20
POWER
Duct
100 mm or more
Other device
Door
PLC of
rack
Programming Cable
Approx. 180 mm
6
Installation Environment and Precaution
ATTENTION
Precautions for Electrostatic Discharges
Excessive static electricity can be generated in dry conditions, so
please make sure to discharge electrostatic charges by touching a
grounded metal bar before contacting the module.
ATTENTION
Contacting the Module
Do not use thinners, which can damage or degrade PCB circuit
board.
7
Mounting/Dismounting Module
Mounting Dismounting
1. Insert the module by inserting the 1. Unfasten the screw that holds the
tab into the groove first and pushing module in place using a
the module against the backplane. screwdriver.
2. Push the top of the module toward 3. Hold on pressing the locking button
the backplane until it is clamped in on the top edge of the module, and
place. pull the module from the backplane
Locking button
screwdriver
8
Wiring
Power Supply Module Wiring
LX700 power supply module)
CPU
POWER
twisted pair cable.
FUSE
USE ONLY
Breaker 250V 1.5A
Use an isolation
transformer when effects
from noise are great. 85 to 264 VAC
Frame ground
Use 2mm2 or thicker cable
for grounding +
24V DC 0.5A Output
ATTENTION
Control Power (24V)
24V can be supplied to an I/O Module.
Must avoid parallel connections with other 24V power supply
modules or with other power supply modules.
9
Terminal for the Power Supply Module
• The terminal screw M3.5 is recommended.
• The compressed connection terminal is recommended for the wiring.
Power
equipment
External I/O
device
isolation transformer
PLC
isolation transformer
10
10
Grounding
Grounding the PLC in Noisy Environments
• Connected to the metal part of backplane, the frame ground terminal is
connected to a solid earth ground.
• Use ground wires with a minimum of 2mm2 and the triple grounding connection
which has a resistance of less than 100 Ω.
• The point of grounding should be as close to the PLC as possible and the ground
wire should be as short as possible.
• If two devices share a single ground point, it may produce an adverse effect.
Always use an exclusive ground for each device.
11
Operating Condition Setting
LX-CPU700p Processor Module
CPU700P
CPU
RUN COM1
PROG COM2
TEST ERROR
BATT
INIT
TEST
RUN
RMT
PROG
COM1
RS232C
RS485
4 3 21
87 6 5 43 2 1
COM1
RS232C
RS485 Operating Condition
Setting Switches
ON
(Front) (Bottom)
OFF (4) OFF (3) Off if the system is not a termination station.
(Disables termination for COM1 terminal)
For RS-485 communication, set both pins 1 and 2 to
ON (2) ON (1) On if the system is a termination station. (Enables ON
termination for COM2 terminal)
2, 1
For RS-485 communication, set both pins 1 and 2 to
OFF (2) OFF (1) Off if the system is not a termination station.
(Disables termination for COM2 terminal)
12
12
Switch for Communication and Program Booting Method Setting
(DIP Switch 2)
Pin setting
Pin No. Description DIP Switch 2
(Pin No.)
Sets the communication speed on COM2 terminal to
OFF (8) OFF (7)
9600 bps
Sets the communication speed on COM2 terminal to
ON (8) OFF (7)
19200 bps
8, 7
Sets the communication speed on COM2 terminal to
OFF (8) ON (7)
38400 bps
Sets the communication speed on COM2 terminal to
ON (8) ON (7)
4800 bps
Sets the communication speed on COM1 terminal to
OFF (6) OFF (5)
9600 bps
8 7 6 5 4 3 2 1
Sets the communication speed on COM1 terminal to
ON (6) OFF (5)
19200 bps
6, 5
Sets the communication speed of COM1 terminal to
OFF (6) ON (5)
38400 bps
Sets the communication speed on COM1 terminal to
ON (6) ON (5)
4800 bps ON
13
Input/Output Modules
The following table shows the general I/O modules that can be used in an LX700
PLC system whose processor module is LX-CPU700p. For more information on
these I/O modules, refer to the LX700 Plus System (LX-CPU700p) User Manual.
Besides those I/O modules, a wide range of special modules including A/D, D/A,
RTD, TC conversion modules are available. For more information on the special
modules that can be used in an LX700 PLC system, refer to the LX700 Plus System
(LX-CPU700p) User Manual and the installation instructions and user manual for
each module.
14
14
Digital Input Module Specifications
Input type DC Input AC Input
Catalog number LX-X16D LX-X32D LX-X64D LX-X16A110 LX-X16A220
Number of input
16 points 32 points 64 points 16 points
points
Insulation method Photocoupler
Rated input
12 to 24V dc 100 to 120V ac 200 to 240V ac
voltage
Operating voltage
10.2 to 26.4V dc 85 to 132V ac 170 to 264V ac
range
Max. input current 10 mA or less (at 24V) 20 mA or less
ON voltage/ Min. 80V/ Min. 160V/
Min. 9.6V
current 6 mA 6 mA
OFF voltage/ Max. 30V/ Max. 50V/
Max. 2.5V
current 3 mA 3 mA
Input impedance: Approx. 3KΩ Approx. 15KΩ Approx. 20KΩ
OFF →
10 ms or less 15 ms or less
Response ON
time ON →
10 ms or less 20 ms or less
OFF
Internal current
65 mA or less 130 mA or less 250 mA or less 60 mA or less
consumption (5V)
8 points/1 COM
32 points/1 COM
Common method (Common for 8 points/1 COM
(Common for polarity +, -)
polarity +, -)
LED (indication
Operation
LED by 32 points LED
indicator
conversion)
Removable
External cable Connector Connector Removable terminal block
terminal block
connection type (40 pin x 1 EA) (40 pin x 2 EA) (M3.5, 20 pins)
(M3.5, 20 pins)
Recommended
0.5 to 1.25 mm2 0.2 mm2 0.5 to 1.25 mm2
cable size
Weight 170 g 140 g 200 g 200 g
Type (A) Type (B) Type (C) Type (A) Type
15
Digital Relay Output Module Specifications
Output type Relay Output
Catalog number LX-Y16R LX-Y16RV LX-Y32RV
Number of output points 16 points 32 points
Insulation method Photocoupler
1A 250V ac,
Rated load voltage 2A 250V ac, 2A 30V dc
1A 30V dc
OFF → ON 10 ms or less
Response time
ON → OFF 10 ms or less
Mechanical 30 million times
Life time
Electric 200 thousand times
External power supply 24V 150 mA or less
Surge protection None Varistor
Internal current
120 mA or less 180 mA or less
consumption (5V)
Common method 8 points/1COM 32 points/1COM
Operation indicator LED
External cable connection Connector
Removable terminal block (M3.5, 20 pins)
type (40 pin x 1 EA)
2 0.2 mm2
Recommended cable size 0.5 to 1.25 mm
Weight 225 g 235 g 300 g
Type (A) Type (B) Type
16
16
Digital Transistor Output Module Specifications
Transistor Output
Output type
NPN
Catalog number LX-Y16T LX-Y32T LX-Y64T
Number of input points 16 points 32 points 64 points
Insulation method Photocoupler
Rated load voltage 12 to 24V dc
Operating load voltage range 10 to 30V dc
Max. load current 0.6A/point 0.4A/point 0.2A/point
OFF state leakage current 100 µA or less
OFF → ON 1 ms or less
Response time
ON → OFF 1ms or less
Internal current consumption
120 mA or less 180 mA or less 250 mA or less
(5V)
Surge absorber Zener diode
Common method 8 points/1COM 32 points/1COM
LED (indication by 32
Operation indicator LED
points conversion)
External cable Removable terminal Connector Connector
connection type block (M3.5, 20 pins) (40 pin x 1 EA) (40 pin x 2 EA)
2 2
Recommended cable size 0.5 to 1.25 mm 0.2 mm
Weight 170 g 140 g 205 g
Types (A) Type (B) Type (C) Type
17
Input/Output Module Wiring Diagrams
LX-X16D Wiring Diagram
Internal circuit
Vcc
12V to 24V DC
COM
12V to 24V DC
COM
NC NC: No Connection
NC
18
18
LX-X64D Wiring Diagram
COM 40 39 COM
X0 1 2 X1
COM 38 37 COM
24V 2
3 4 3 • The internal circuit is the same
NC 36 35 NC 4 with LX-X32D.
DC 5 6 5
NC 34 33 NC 6 7 • The connectors [I] and [II] have
7 8
X0 32 31 X1 8 9
opposite orientation each other,
2 3 9 10 so be careful with wiring.
30 29 A B
4 5 11 12 • The COM terminal of the
28 27 C D
6 7 13 14 connector has a short inside of
26 25 XE XF the unit.
8 9 15 16
24 23 X10 X11 • For more information on wiring
A B 17 18
22 21 12 13 method, refer to the LX700 Plus
C D 19 20
20 19 14 15 System (LX-CPU700p) User
XE XF 21 22 Manual.
18 17 16 17
X10 X11 23 24 • Use separate commercial cable
16 15 18 19
12 13 25 26 harness (LX-CBLDC) and Pin
14 13 1A 1B Type Ass'y (LX-PIN40) for
14 15 27 28
12 11 1C 1D external connection.
16 17 29 30
10 9 X1E X1F • NC: No Connection
18 19 31 32
8 7
1A 1B 24V NC 33 34 NC
6 5
1C 1D DC NC 35 36 NC
4 3 COM COM
X1E X1F 37 38
2 1 COM COM
39 40
(I) (II)
0 F
COM
COM
COM
LX-X16A110: 100 to 120V ac
LX-X16A220: 200 to 240V ac
19
LX-Y16R and LX-Y16RV Wiring Diagram
Internal circuit
250V AC COM
30V DC
COM
24V DC
Varistor
LX-Y16R: Has no varistor
LX-Y16RV: Has a varistor
20
20
LX-Y16T Wiring Diagram
Internal circuit
12V to 24V DC COM (-)
Y0 to YF
12 to 24V DC(+)
12V to 24V DC
L 6 7 8 7
L
Y0 to YF
L 8 9 10
9
L
L A 11 12 B L
L C 13 14
D
L
L YE 15 16
YF
L 12 to 24V DC(+)
L Y10 17 18
Y11
L
L 12 19 20
13 L
L 14 21 22
15
L • COM (VDC-) and VDC+ (12 to 24V) terminals of the
L 16 23 24 17 L connector has a short inside of the unit.
L 18 25 26
19 L • For more information on wiring method, refer to the
LX700 Plus System (LX-CPU700p) User Manual.
L 1A 27 28
1B
L
• Use separate commercial cable harness (LX-CBLTR) and
L 1C 29 30
1D L
Pin Type Ass'y (LX-PIN40) for external connection.
L 1E 31 32 1F L
• NC: No Connection
NC 33 34 NC
NC 35 36 NC
VDC+
37 38 VDC+
VDC - (COM)
39 40 VDC - (COM)
21
LX-Y64T Wiring Diagram
L Y0 1 2 Y1 L
VDC (-COM) 40 39 VDC (-COM) 2 3
L 3 4 L
VDC+ VDC+ • The internal circuit is the
38 37 L 4 5 6 5 L
6 7 same with LX-Y32T..
NC 36 35 NC L 7 8 L
8 9
• COM (VDC-) and VDC+ (12
NC 34 33 NC L 9 10 L to 24V) terminals of the
L Y1F 32 31 Y1E L L A 11 12 B
L connector has a short
1D 1C L
L 30 29 L C 13 14
D
L inside of the unit.
L 1B 28 27 1A L L YE 15 YF • For more information on
16 L
L
19 18 L Y10 Y11 wiring method, refer to
26 25 L 17 18 L
17 16 L the LX700 Plus System
L 24 23 L 12 19 20
13 L
(LX-CPU700p) User
L 15 22 14 L 14 15
21 L 21 22 L Manual.
12 L
L 13 20 19 L 16 23 24 17 L • Use separate commercial
L Y11 18 Y11 cable harness (LX-CBLTR)
17 L L 18 25 26
19 L
L
YF
16 15
YE
L 1A 1B and Pin Type Ass'y (LX-
L 27 28 L
PIN40) for external
C L
L D 14 13 L 1C 29 30
1D L
B A connection.
L 12 11 L L 1E 31 32 1F L
• NC: No Connection
L 9 10 9
8 L
NC 33 34 NC
L 7 8 7
6 L
NC 35 36 NC
5 4 VDC+ VDC+
L 6 5 L 37 38
L 3 4 3
2 L VDC (-COM) 39 40 VDC (-COM)
L Y1 2 1
Y0 L
(I) (II)
L 0
L 1
L 2
L 3
L 4
L 5
L 6
L 7
L 8
L 9
L A
L B
L C
L D
L F
L F
COM
AC 10 0 t o 2 4 0 V
22
22
Electrical & Electronics Division (EBG), Gate No.7
Powai Campus, Mumbai 400 072