You are on page 1of 1

Recent revision history

Rev. Description Date


A TENDER SUBMISSION 17.08.2017

WALL NOTES:
1. ALL LEVELS OPENING LOCATIONS AND DIMENSIONS SHALL BE
VERIFIED WITH ARCHITECTURAL AND MEP DRAWINGS BEFORE
CONSTRUCTION(UNO)

2. THE INTENTION OF RC WALL ELEVATIONS DRAWINGS TO SHOW THE


REQUIRED REINFORCEMENT IN WALLS AND DEPTH OF DOOR
G21 G2H OPENINGS AND LINK BEAMS. Notes & Legend

CORE WALL SCHEDULE CORE WALL SCHEDULE Contractor must verify all dimensions on site before commencing work
3. FOR LAYOUT/SETTINGS OF WALLS AND OPENINGS REFER TO GA or preparing shop drawings. Do not scale drawings.
FOR CONTINUATION REFER TO DRAWING S632 FLOOR PLANS(UNO).
FOR CONTINUATION REFER TO DRAWING S632 THK VERTICAL HORIZONTAL CONCRETE THK VERTICAL HORIZONTAL CONCRETE
(mm) REBAR REBAR GRADE f'c/fcu 4. MAJOR MECHANICAL/ELECTRICAL OPENINGS ONLY ARE SHOWN ON
(mm) REBAR REBAR GRADE f'c/fcu STRUCTURAL DRAWINGS.FOR OTHER MEP
(MPa) (MPa)
BRT-10 BRT-10 OPENINGS/SLEEVES/BLOCKSOUTS/SOCKETS SIZE AND LOCATION
THROUGH RC WALLS REFER TO MEP DRAWINGS IN COORDINATION
45820 45820 WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS.
BSPB-1
5. STARTER BARS FROM FOUNDATION INTO RC WALLS SHOULD BE SAME
ORDER/SPACING OF VERTICAL BARS AT FOUNDATION LEVEL (UNO).
400 T12-200 T12-200 C60/75 400 T16-100 T12-200 C60/75
# 6. LEVEL SHOWN IN ELEVATIONS STRUCTURAL SLAB LEVEL (SSL) (UNO).

7. THE INTENTION OF INDICATING MEP OPENINGS IN WALL ELEVATIONS


BRT-09 BRT-09 (IF SHOWN) IS TO REFLECT THE CONCEPT OF WALL CUTS
CONSIDERED IN THE STRUCTURAL ANALYSIS AND DESIGN
42220 42220
IN THE EVENT THAT MEP PENETRATON REQUIREMENNTS ARE
BSPB-1 DIFFERENT FROM THE SIZE LOCATIONS INDICATED ON WALL
ELEVATIONS.THEN THE CONTRACTOR SHOULD SEEK THE
ENGINEER'S REVIEW AND APPROVAL.
400 T12-200 T12-200 C60/75 400 T16-100 T12-200 C60/75
# 8. OPENINGS FOR MEP SERVICES LESS THAN 300mm HAVE NOT
BEEN REFLECTED ON STRUCTURAL ELEVATIONS.THE SETTING OUT OF
THESE OPENINGS SHALL BE COORDINATED BY THE CONTRACTOR
BRT-08 BRT-08 CONSIDERING THE FOLLOWING
38620 38620
A - AT LINK BEAMS POSITION THE OPENING APPROXIMATELY AT
BSPB-1 MID-DEPTH AND MID SPAN OF LINK BEAM AND AVOID
COMPROMISING THE MAIN TOP/BOTTOM STEEL
400 T16-100 T12-200 C60/75 REINFORCEMENT
400 T16-200 T12-200 C60/75 B - AT CORE WALLS POSITION THE OPENINGS AWAY FROM EDGES
# (INCLUDING DOOR OPENINGS) AT LEAST A DISTANCE
EQUIVALENT TO WALL THICKNESS OR BEAM DEPTH WHICHEVER
BRT-07 BRT-07 SMALLER
C - GENERAL
35020 35020 - THE INTRODUCTION OF THE ADDITIONAL OPENINGS SHALL
AVOID DISTRUPTION TO MAIN REINFORCEMENT AS MUCH AS
BSPB-1 POSSIBLE AND UTILIZE THE CLEAR SPACING IN BETWEEN
REINFOREMENT.
400 T16-200 T12-200 C60/75 400 T16-100 T12-200 C60/75 - FOR RECTANGULAR OPENINGS. THE LONGER SIDE OF THE
# OPENING SHALL BE ALIGNED VERTICALLY AND
THE SHORTER SIDE HORIZONTALLY.

BRT-06 BRT-06 NOTE:


31420 31420 [#] DENOTES WALL TIES ON VERTICAL BARS.

BSPB-1

400 T20-200 T12-200 C60/75 400 T20-100 T12-200 C60/75


#
NOTES:

BRT-05 BRT-05 1. DO NOT SCALE THE DRAWING


27820 27820 2. ALL THE DIMENSIONS ARE IN MILLIMETERS,
BSPB-1 LEVELS ARE IN METERS (UNO)

3. STANDARD DETAILS & GENERAL NOTES REFER


400 T20-200 T12-200 C60/75 400 T20-100 T12-200 C60/75 TO DRAWING NOS.
# SMH-RBG-DD-ST-00-00-GN-S001 TO S003
SMH-RBG-DD-ST-00-00-GN-S010 & S011
SMH-RBG-DD-ST-00-00-GN-S020 TO S027
BRT-04 BRT-04
4. FOR COLUMN REINFORCEMENT REFER TO DRAWINGS
24220 24220
SMH-RBG-DD-ST-03A-00-SH-S412
BSPB-1
5. FOR WALL REINFORCEMENT REFER TO DRAWING NOS.
SMH-RBG-DD-ST-03A-00-EL-S631 TO S650 Key Plan
400 T25-200 T12-200 C60/75 400 T25-100 T12-200 C60/75
# # 6. FOR CORES 1 & 2 SETTING OUT PLAN REFER TO
DRAWING NOS.
SMH-RBG-DD-ST-03A-00-PL-S561 TO S563
BRT-03 BRT-03
20620 20620 7. FOR CONCRETE STRENGTH & COVER REFER TO

TYP.
650
DRAWING NOS.
BSPB-1 SMH-RBG-DD-ST-00-00-GN-S011
850 700
TYP. TYP. 400 T25-100 T12-200 C60/75 8. STAIRS SHOWN ARE INDICATIVE. REFER TO
400 T25-200 T12-200 C60/75 ARCHITECTURAL DRAWINGS FOR DETAILED SET-OUT

2480
#

TYP
#
9. FOR SLEEVES IN SLABS/WALLS REFER TO MEP DRAWINGS
BRT-02 BRT-02
10. REFER TO ARCHITECTURAL DRAWINGS FOR DRAINAGE
17020 17020 SLOPE GRADIENTS & DIRECTIONS.
BSPB-1 11. SLAB THICKNESSES SHOWN ON DRAWINGS INDICATES
THICKNESSES AT BOTTOM OF FALLS.
400 T25-200 T12-200 C60/75 400 T32-100 T16-200 C60/75
# 12. REFER TO MEP DRAWINGS FOR THE LOCATION &
# SETTING OUT OF DRAIN PITS & TRENCHES
Project

BRT-01 BRT-01 13. FOR DROP PANELS REFER TO DRAWING NOS. SHAMS MARINA
13420 13420 14. REFER TO ARCHITECTARAL DRAWINGS FOR
FOR CONTINUATION REFER TO DRAWING FOR CONTINUATION REFER TO DRAWING SLAB EDGE SETTING OUT.

SMH-RBG-DD-ST-00-00-EL-S626 SMH-RBG-DD-ST-00-00-EL-S626
Client
ALDAR
WALL W3-2
WALL W3-1 SCALE 1 : 100
SCALE 1 : 100
Issuer

G2H

G22 W3-2

Project number Size check


M7373 25mm
Checked Approved Sheet size Scale
AP PM A1 As indicated

W3-1
Sheet title
BRT-B - CORE WALL ELEVATIONS
& DETAILS - SHEET 1
G21

Aconex number

SMH-RBG-TD-ST-03B-00-EL-S631
Sheet number Revision
CORE 3-KEY PLAN S631 A
SCALE 1 : 150
Status
TENDER SUBMISSION
Date generated 16-08-2017 15:42:13 C:\Users\GNH\Documents\M7373-RBG-BRT-STR-V14-Central_GNH.rvt

You might also like