Professional Documents
Culture Documents
SHEET
SHEET TITLE
NO. NO.
COVER SHEET
GENERAL
01 OF 09 U1-3110-01 TABLE OF CONTENTS, VICINITY MAP, SITE PLAN
02 OF 09 U1-3110-02 LEGEND, SYMBOLS, ABBREVIATIONS, GENERAL NOTES, INDEX PLAN
CIVIL
03 OF 09 U1-3110-03 TRANSMISSION LINE-3 PLAN, PROFILE AND ROAD SECTION (STA.0+010-STA.0+700)
04 OF 09 U1-3110-04 TRANSMISSION LINE-3 PLAN, PROFILE AND ROAD SECTION (STA.0+700-STA.1+400)
05 OF 09 U1-3110-05 TRANSMISSION LINE-3 PLAN, PROFILE AND ROAD SECTION (STA.1+400-STA.2+100)
06 OF 09 U1-3110-06 TRANSMISSION LINE-3 PLAN, PROFILE AND ROAD SECTIONS (STA.2+100-STA. 2+939)
07 OF 09 U1-3110-07 PIPE CROSSING DETAIL, TYPICAL CULVERT CROSSING DETAILS AND CONCRETE ENCASEMENT DETAIL
08 OF 09 U1-3110-08 MISCELLANEOUS DETAILS 1
09 OF 09 U1-3110-09 MISCELLANEOUS DETAILS 2
PANGLAO, BOHOL
1 VICINITY MAP
U1-3110-01 SCALE NTS
AD
RO)
LAO AY
P A NG IGHW
IS - AL H
DAU NTR
(CE
AD
SRO
ES
CC
TA
R
PO
AIR
NEW BOHOL AIRPORT
RESETTLEMENT AREA
2 SITE PLAN
U1-3110-01 SCALE NTS
5. PIPE AND PIPE JOINTS MAY BE DEFLECTED WITHIN THE RECOMMENDED DEFLECTION BY PIPE
MANUFACTURERS SUBJECT TO THE ENGINEER'S APPROVAL.
SLEEVE TYPE COUPLING
EXPANSION/FLEXIBLE JOINT 6. UNLESS OTHERWISE SHOWN OR SPECIFIED. WHENEVER A PROPOSED PIPE HAS TO
ROAD CONCRETE CROSS A CULVERT (PIPE OR BOX CULVERT), SUCH CULVERT CROSSING SHALL BE
INCLUDED IN THE UNIT BID PRICES FOR THE PIPE.
DIRT ROAD
HOUSE
7. IN CROSSING CULVERTS IN PIPE-UNDER MANNER, CONCRETE ENCASEMENT SHALL BE PROVIDED
D
OA
RCP, CULVERT WHERE FLEXIBLE JOINTS OCCUR OR WHERE CLEARANCE BETWEEN PIPES IS LESS THAN 0.30M.
SR
RIVER or CREEK FOR PIPE-OVER MANNER, ENCASEMENT SHALL LIKEWISE BE PROVIDED IN PORTIONS WHERE PIPE
ES
COVER IS LESS THAN THE SPECIFIED. MINIMUM LENGTH OF CONCRETE ENCASEMENT SHALL BE
PROPERTY LINE
CC
THE CULVERT WIDTH OR OUTSIDE DIAMETER PLUS 0.30M OR BOTH SIDES.
TA
CONTOUR LINE 14.00
R
8. FINAL ALIGNMENT OF THE PROPOSED LINE SHALL BE COORDINATED WITH THE LGU, PROVINCIAL
ORDINARY TREE
PO
ENGINEERING OFFICE, OR DPWH WHO MAY HAVE JURISDICTION ON THE ROAD.
AIR
COCONUT TREE
ABBREVIATIONS :
DPWH DEPT. OF PUBLIC WORKS & HIGHWAYS RCBC REINFORCED CONCRETE BOX CULVERT
L.L.S.B.I. LIMIT OF LUMP SUM BID ITEM TBM TEMPORARY BENCH MARK
mm MILLIMETER W/ WITH
MIN. MINIMUM
1 INDEX MAP
HOR. SCALE 1:15,000 M. SCALE 1:15,000m.
UNDER DOTC-FUND
EARTH CONCRETE ROAD CONCRETE ROAD EARTH
0.80
8+
70
0
0
00
0+
8+
60
0
PULL JOINTS
(AS REQUIRED)
ST ART
00
0+1
(S
2
A.
T
0+ OF
01 U-3
PULL JOINTS
STA. 0+700
SHEET TR-02
0
(AS REQUIRED)
3 INTERCONNECTION DETAIL
11
0+200 SEE DETAIL
0)
0+300
PULL JOINTS
(AS REQUIRED)
30.00
RIGHT OF WAY
2.00 6.50 2.50 6.50 2.00
0.80
8.75
2 ROAD SECTION
SCALE 1:100m.
3 INDEX MAP
NOT TO SCALE
STA. 1+400
SHEET TR-03
STA. 0+700
SHEET TR-01
2
MATCHLINE WITH
1
SEE STD. DWG.
30.00
RIGHT OF WAY
2.00 6.50 2.50 6.50 2.00
0.80
8.75
2 ROAD SECTION
SCALE 1:100m.
3 INDEX MAP
NOT TO SCALE
STA. 1+400
STA. 2+100
SHEET TR-03
SHEET TR-04
MATCHLINE WITH
MATCHLINE WITH
1
SEE STD. DWG.
ST ND O
A.
(E
2+9 F U-3
28
30.00
RIGHT OF WAY
110
2.00 6.50 2.50 6.50 2.00
)
EARTH CONCRETE ROAD CONCRETE ROAD EARTH
4 MAIN WATER METER DETAIL
0.80
SEE DETAIL
8.75
2+9
00
3
2 ROAD SECTION
SCALE 1:100m.
4 INDEX MAP
800
2+ NOT TO SCALE
2
SEE STD. DWG.
2
PROP. 150mmx150mm TEE
2+7
00
2+500 2+400
PULL JOINTS 2+600
2+3
(AS REQUIRED) AIRPORT ACCESS ROAD 00
PULL JOINTS
(AS REQUIRED)
PULL JOINTS
(AS REQUIRED)
PULL JOINTS
(AS REQUIRED)
2+
200
C
L
6.50
CONCRETE ASPHALT
0.80
4.25
3
T R-0 0
T +10
3 ROAD SECTION EE
SH TA. 2
S
2+1
SCALE 1:100m.
00
WITH
HOR. SCALE 1:1000 M. E
IN
CHL
AT
HOR. SCALE 1:100 M. 1 PLAN M
SCALE 1:1000m.
TOP OF ROADWAY/
FINISH GRADE LINE
BACKFILL
( SEE SPEC.)
400
800
300
0.80 (MIN)
16 mm CONT.
( AS SHOWN )
400
SEE U-3130
0.15
0.30
12 mm TIES
PLAN
0.50 (MIN)
AT .60 O.C.
BENDS
0.
15
0.15
15
0.
UNDISTURBED SOIL
NOTES:
1 ALL DIMENSIONS ARE IN METERS UNLESS OTHERWISE SHOWN
400
CONCRETE PIPE SUPPORT
SCALE 1:30m. SCALE 1:30m.
100 200
800
3400
LIMIT
(L=VARIABLE)
LIMIT
WIDTH OR DIAMETER SECTION
(L=VARIABLE) TOP OF ROADWAY/
0.30 0.30
0.30 0.30 FINISH GRADE LINE STEEL PIPE
PROP. PIPE
WIDTH OR DIAMETER
INSTALLATION DETAILS OF MAIN WATER METER
0.80 (MIN)
TOP OF ROADWAY/
FINISH GRADE LINE 4
SCALE 1:20m
0.30 CLEAR
0.80 (MIN)
PROP. PIPE
0.30
BENDS
EXIST. RCBC/ 0.
15
5
RCPC
1
0.
NOTES:
1 WHENEVER A PROPOSED PIPE ENCOUNTERS AN OBSTRUCTING CULVERT,
SUCH PIPE SHALL BE DEFLECTED BELOW CULVERT AS SHOWN IN TYPICAL DETAIL 3a
IF INVERT OF CULVERT DOES NOT EXCEED 1.25m BELOW GROUND SURFACE,
OTHERWISE TYPICAL DETAIL 3b SHALL BE USED.
3 TYPICAL CULVERT CROSSING DETAILS 2 D=RCP (OUTSIDE OR INSIDE) DIAMETER OR RCBC (OUTSIDE OR INSIDE) WIDTH.
NOT TO SCALE
3 LIMIT=TOTAL OF RCPC DIAMETER OR RCBC WIDTH PLUS 0.30m ON BOTH SIDES AS
THE CASE MAY BE WHICH ARE INDICATED ON THE PIPELINE PLANS.
3 LEGEND:
1 COMPACTED SELECTED NATIVE MATERIALS
BACKFILL (SEE SPEC.).
0.80 (MINIMUM)
VARIES
d
2 APPROVED SAND BEDDING & BACKFILL HAND
d\2
PLACED AND COMPACTED.
CONCRETE
3 PAYMENT FOR ANY RESURFACING WILL BE
"C"
1 BASED ON MAXIMUM TRENCH WIDTHS PER POURED AGAINST THRUST BLOCK
SIZE PIPE SHOWN. RESTORATION OF PAVEMENT UNDISTURBED SOIL
0.15
SUB-BASE AND COURSE SAME THICKNESS AS B N.
(TYPICAL)
EXISTING. MI
0 .30
NOTE: A
0.15 ALL DIMENSIONS IN METERS EXCEPT WHERE OTHEREWISE SHOWN. 3a ELEVATION
SPACE SHALL BE PROVIDED FOR PIPE JOINTS TO PREVENT BRIDGING.
2 SCALE 1:2m.
3b SECTION
SCALE 1:2m.
TABLE OF TRENCH DIMENSION (IN METERS)
3" &
TABLE OF MINIMUM THRUST BLOCK DIMENSIONS FOR
in. 4" 6" 8" 10" 12" 14" 16" 18" 20" 24"
PIPE DIAMETER
UNDER NOTES:
mm 75mm & 100 150 200 250 300 350 400 450 500 600 PIPE THRUST BLOCK BEARING 1 ABOVE AREAS BASED ON AN ASSUMED
UNDER SIZE "C" AREAS IN SQ. METERS SOIL BEARING PRESSURE OF 96 kPa (2000psf.).
MINIMUM 'W' 0.20 0.40 0.45 0.50 0.55 0.60 0.65 0.70 0.75 0.80 0.90 mm (in.) METERS 2 REDUCE OR INCREASE AREAS PROPORTIONATELY
TO SUIT ACTUAL FIELD CONDITIONS UPON
75 (3") & 100(4") 0.25 0.14 0.12 *
MAXIMUM 'W' 0.30 0.70 0.75 0.80 0.85 0.90 0.95 1.00 1.05 1.10 1.20 APPROVAL OF ENGINEER.
1 TYPICAL TRENCH DETAIL 150 (6") 0.25 0.31 0.17 0.12
3 CONCRETE FOR FOR THRUST BLOCK SHALL
NOT TO SCALE 200 (8") 0.25 0.54 0.30 0.15 BE 13.8 MPa (2000psi.).
250 (10") 0.25 0.85 0.46 0.24 4 TRUST BLOCKS NOT REQUIRED ON STEEL PIPE
300 (12") LINES WITH WELDED OR FLANGED JOINTS OR
0.30 1.23 0.66 0.34
ON SOLVENT WELDED PVC PIPE.
350 (14") 0.30 1.67 0.90 0.46
5 WHERE PIPE CONNECTS TO A FITTING ON A
400 (16") 0.30 2.18 1.18 0.60 STEEL PIPELINE, THE STEEL PIPELINE SHALL
450 (18") BE BLOCKED AS SHOWN HEREON.
0.35 2.76 1.49 0.76
500 (20") 0.35 3.41 1.84 0.94 6 BEARING AREAS BASED ON INTERNAL
PRESSURE OF 106m (150psi).
600 (24") 0.40 4.91 2.65 1.35
SEE TABLE
FOR TEE * THRUST BLOCK NOT REQUIRED
0.15
VERTICAL CONCRETE THRUST
3 BLOCKS (DOWNWARD THRUST)
D
NOT TO SCALE
0.15
2f TEE
SCALE 1:2m.
TA E
REDUCER *
200 (8") 0.30 0.45 75 (3")
2b 2c 250 (10") 0.35 0.50 100 (4")
SCALE 1:2m. SCALE 1:2m. POUR ALL THRUST BLOCKS
300 (12") 0.40 0.55 CONC. PIPE SUPPORT 150 (6")
AGAINST UNDISTURBED SOIL
350 (14") 0.45 0.60 200 (8")
TABLE OF MINIMUM THRUST BLOCK BEARING AREAS IN 400 (16") 0.50 0.70
19mm (3/4") CHAMFER
250 (10")
(TYPICAL ALL CORNERS)
2e OFFSETS & BEND 450 (18") 0.55 0.75 300 (12")
PIPE TEE & 500 (20") 0.30
SCALE 1:2m. 0.60 0.80
SIZE DEAD BEND OR
mm (in.) END BEND BEND REDUCER 600 (24") 0.70 0.90 NOTES:
NOTES: 1
75 (3") 0.05 0.07 0.04 0.02
1 ABOVE AREAS BASED ON AN ASSUMED 5 THRUST BLOCKS NOT REQUIRED ON STEEL PIPE
100 (4") 0.09 0.12 0.07 0.04 SOIL BEARING PRESSURE OF 96 kPa (2000psf.). LINE WITH WELDED OR FLANGED JOINTS OR ON NOTES: 2 CONCRETE FOR ANCHOR BLOCKS SHALL BE 13.8 Mpa.
SOLVENT WELDED PVC PIPE. (2000psi).
150 (6") 0.20 0.28 0.15 0.08 2 REDUCE OR INCREASE AREAS PROPORTIONATELY 1 ALL CONCRETE SHALL BE POURED TO AVOID INTERFERENCE
TO SUIT ACTUAL FIELD CONDITIONS UPON 6 WHERE PIPE CONNECTS TO A FITTING IN A WITH BOLTED CONNECTIONS. 3
200 (8") 0.35 0.50 0.27 0.14
APPROVAL OF ENGINEER. STEEL PIPELINE, THE STEEL PIPELINE SHALL 2 PIPE SUPPORTS TO BE LOCATED AS SHOWN ON THE PLANS.
250 (10") 0.55 0.77 0.42 0.21 BE BLOCKED AS SHOWN HEREON.
3 CONCRETE FOR FOR THRUST BLOCK SHALL 4
300 (12") 3 SPECIAL PIPE SUPPORTS SHALL BE INSTALLED IN ACCORDANCE
0.79 1.11 0.60 0.31 BE 13.8 MPa (2000psi.). 7 BEARING AREAS BASED ON INTERNAL PRESSURE
WITH DETAILS SHOWN ON THE PLANS.
350 (14") 1.07 1.52 0.82 0.42 OF 106m (150 psi.).
4 ALL CONCRETE SHALL BE POURED TO AVOID
4 WHEN SUPPORTING PIPE AND FLANGE ON THE SAME LINE OF
400 (16") 1.40 1.98 1.07 0.55 INTERFERENCE WITH JOINTS.
PIPE, CONCRETE PIERS FOR ALL PIPE SUPPORTS SHALL HAVE
* SEE PLANS FOR BEARING AREAS. DIMENSION "A AS A FLANGE SUPPORT.
450 (18") 1.77 2.51 1.36 0.69
500 (20") 2.19 3.10 1.68 0.85
600 (24") 3.15 4.46 2.42 1.23 2 HORIZONTAL CONCRETE THRUST BLOCKS 4 PIPE SUPPORT DETAIL
SCALE 1:2m. SCALE 1:1m.
25mm(1")POLYETHYLENE OR
POLYBUTYLENE SERVICE
LINE (ISO.SIZE).
W
INSTALLATION OF BURIED
1 25mm(1") AIR VACUUM AND AIR RELEASE ASSEMBLY (AV/AR) 4 GATE VALVE 300mm (12") & SMALLER 5 VALVE BOX AND COVER
NOT TO SCALE NOT TO SCALE NOT TO SCALE
A321-200
A321-200
A321-200
A321-200
A321-200
A321-200
A321-200
A321-200
A321-200
A321-200
A321-200
REFER TO AGL DRAWINGS FOR CABLE SCHEDULE
POWER HOUSE
GH-1 GH-2
TREATED WATER
TANK
STP OUTDOOR SUBSTATION
PARKING SPACE
OUTDOOR
SUBSTATION
GRIT CHAMBER/
CONTROL
PUMP STATION
GH-1
LABORATORY ROOM
1-01 1-02
PAN.
1-03
DISINFECTION
TANK
SLUDGE
THICKENER
GH-1
SLUDGE
DRYING BED
WPH ELECTRICAL ROOM
OXIDATION
DITCH
FINAL
CLARIFIER
SLUDGE
DRYING BED
DISTRIBUTION
CHAMBER
VOR/DME
WDIL ILS/GS
ILS/LLZ PAPI
SALS
PALS
PAPI