GM27VS configuration and instructions V1.0 alarms.If the value is set as 75,  MAX Accumulating Time:9999.

9Hours(Min Store time:6min)


Panel Design and Display then the alarm is disabled.  Alarm Output:3AMP Non-contact output
When the Freq is lower than the  Working condition:-30-70℃
value and comes into under freq  Storage condition:-40-85℃
Under freq 0.0-75.0Hz delay but still lower (normal faults  Protection Level IP54:when waterproof rubber gasket is added
Status indication P03
alarm (0Hz) delay), then under freq alarm between controller and its panel
Line alarms.If the value is set as 0, then  Overall dimension:100mm*100mm*77mm
voltage Page-change
the alarm is disabled.  Panel cutout::91mm*91mm
Phase Value increase
When the line voltage is higher  Weight:0.15Kg
current than the value and comes into over
Setting 50~800V Typical diagram
Over line voltage delay but still higher
Rest alarm P04 (450V) P1 P2
voltage (normal faults delay), then over L1 S1 S2
P1 P2
frequency alarms.If the value is set L2
Frequency Page-change S1 S2
as 500, then the alarm is disabled. P1 P2
Value decrease L3 S1 S2
When the line voltage is lower than
Accumulated N
Time the value and comes into lower
Under line 0~600V voltage delay but still lower (normal
P05
voltage (0V) faults delay), then under line
voltage alarms.If the value is set as
Indicator name Main function 500, then the alarm is disabled.
POWER Light up after switching on the power supply. When the current is higher than the 3 4 5 6 10 11 12 13
RUNNING When the frequency is higher than the "Freq. Phase value and comes into over current IA IB IC ICOM L1 L2 L3 N
for start success", it will be lighted. current 10-6500A delay but still higher (over current CURRENT 0-5A AC INPUT 30-276V
ALARM Flash when any alarm. P08
over-load (500A) faults delay), then over current
Parameters Settings
Press “PROG” for 3 seconds and show that "0---" means entering
alarm alarms.If the value is set as 6500,
then the alarm is disabled.
GV58VS
the password input interface. Press the "+" or "-" key to change the Emergency 0-10.0s Over voltage,over frequency alarm
current password value. Press the "PROG" key to move to the right. If P09 TTL
faults delay (1.5s) delay.
the password error will automatically exit the settings interface, please
Normal Under voltage,under frequency 1 2 7 8 9
re-enter. 2.0-20.0s
After entering the correct password, press the "PROG" key. When P10 alarm alarm delay.
(5.0s)
"P00" is displayed, it indicates that it has entered the setup mode and delay

- +
the first option is displayed. Press the "+" or "-" key to select the options Over
0-3600s
that need to be modified, press the "PROG" key to enter the modified P11 current Current over-load alarm delay. COM NC NO TXD GND RXD
state; press the "+" or "-" key to change the parameter value, press the (30s)
faults delay
"+" or "-" key to remain unchanged, can continuously increase or reduce ALARM OUTPUT
Page- Interval time for water temperature DC 8-36V MAX 3A
the parameter value; after adjustment, press the "PROG" key to return to 1-120s
P12 change and fuel temperature, the max time
the upper parameter browsing interface. After setting the parameters, (120s)
delay is manually change.
press the "PROG" button for 3 seconds, then save and exit the setting Warning: Please don’t move battery during running status or
mode. When the frequency is over than
Freq. it may cause the meter broken.
When setting parameters, if more than 30S is pressed without any 10.0-70.0Hz the pre-set value once on power,
P13 for start
key, the setting interface will automatically exit and the modified (20.0Hz) then it is regarded that engine Notes
success
parameters will be saved. The parameters will take effect immediately crank successfully. 1. If the system checked the frequency is over " Freq. for start
after they are saved and modified. This delay only responds to success "(P13),the meter is connected with main power, then it will
Range Safety
NO. Parameter Notes P14 3-300s(10s) overfrequency and overvoltage regard the genset as cranked successfully. which means the alarm
(defaults) delay
alarms. will occur after the safety delay when the fault is checked.
All the alarm indications and Alarm Alarm relay output setting. 0:alarm 2. When alarm protection occurs, the display page of the alarm
Alarm 0:Disabled 0-120s
P00 outputs are forbidden if it is set as P15 output output disabled, 120:alarm output parameter is automatically displayed. The alarm parameter value is
function 1:Available (120s)
0. delay all the time. locked and flickers. Pressing the "RESET" key can clear the alarm.
Used for setting genset CT primary User 0000-9999 Password to enter parameter 3. All rights reserved. No part of this duplication may be reproduced
5-6000A/5A P16
P01 CT rate current, secondary rated current password (0000) setting interface in any material form(including photocopying or storing in any medium
(500A/5A)
5A. Options Parameters by electronic means or others) without the written permission of the
When the Freq is higher than the  Operation Voltage:DC8~36V Continuous copyright holder.
Over freq 20.0-75.0Hz value and comes into over freq  Power Consumption:MAX1.5W 4. MEBAY Technology reserves the rights to change the contents of
P02
alarm (57.0Hz) delay but still higher (emergency  AC Voltage Input:3 phase 4 wire 30-276VAC(ph-N),10-75Hz this document without prior notice.
faults delay), then over frequency  AC Current Input:Secondary input of current transformer MAX 5A