You are on page 1of 7

FERROSCAN TEST REPORT

PROJECT NAME : PRELIMINARY ENGINEERING ANALYSIS (PEA)


FIELD WORKS (WP4) of mmConsultancy
Services for Vulnerability Assessment a nd
Priorit iz ed In ve st me n t P la n f or Crit ica l
As set s in D ha ka mm f or Urban Resilience Unit
(URU) (Contract Group No.: URP/RAJUK/S-4;
Credit No.:55990)

CLIENT: RAJDHANI UNNAYAN KARTRIPAKKHA (RAJUK)

STRUCTURE NAME:
BUILDING ID:

PREPARED BY:

2ND FLOOR, MAMUN PLAZA,

31, HATKHOLA ROAD, DHAKA-1203.


E- ma il :sa f et yco n sul t an t s .b d@ gm all. com, c eo . scbd @g ma d. co m

Cell: +8801720173132
Table of Contents
1 EXECUTIVE SUMMARY OF THE TEST RESULTS (NDT)...................................1
2 REBAR SCAN USING FERRO-SCANNER...................................................................2
2.1 FERRO-SCAN LOCATIONS................................................................................................... 3
2.2FINDINGS BY DETAILED FERRO SCANNING IN COLUMNS............................4
1 Executive Summary of the Test Results (NDT)

 We have inspected the building visually at 20 September, 2020 for the first time. We have
performed NDT Ferro-scan in columns.

 We have performed detailed rebar scanning using Ferro-Scan at six (6) locations to find the
reinforcement used in structural members. All scans were done for column. Also a lot of
quick scan were performed to verify the reinforcement in columns, beams and slab.
2 REBAR SCAN USING FERRO-SCANNER
2.1 Ferro-Scan Locations

Figure 2- 1: Locations of detailed Ferro-scanning


2.1 Findings by Detailed Ferro Scanning In Columns.
Sampl
Sl. Member Reinforcement
e Location Remarks
No Type Details
Id
Along 300mm Side:
Main Reinforcement: 3-Ø16mm
Tie Bar: Ø10 mm @200mm-250mm-
Ground Column, C2 200mm c/c
01 D-1 Floor (300mm X
Grid=B-08 500mm) Another 500mm Side:
Main Reinforcement: 3-Ø16mm
Tie Bar: Ø10 mm @200mm-250mm-
200mm c/c

Scanning Images from Ferro-Scanner Quick scan

Along 300mm Side Along 300mm Side

Scanning Images from Ferro-Scanner Quick scan


Along 500mm Side Along 500mm Side

Sl. Sample Member Reinforcement


Location Remarks
No Id Type Details
Ferro scan was
Column, Along 300mm Side: not possible along
Ground Main Reinforcement: 2-Ø16mm
C2 500 mm of
05 D-5 Floor
(300mm X Tie Bar: Ø10 mm @200mm- another side of
Grid=A-07
500mm) 250mm-200mm c/c column due to
brick wall

Scanning Images from Ferro-Scanner Quick scan

Along 300mm Side Along 300mm Side