Calculation Notes

PROJECT : ONE & ONLY LE SAINT GERAN


LUXURY VILLAS DEVELOPMENT

DATE: 19-Jun-19
Project: ONE & ONLY LE SAINT GERAN
Date: 19-Jun-2019
Page No. i

Introduction
All design calculations are based on relevant codes of practice. References were made to:
A. Wind Loading
Chapter V CP3 Code of Practice For Wind Loading
B. Aluminium

Design Notes
BS 8118 Part 1: 1991 - Structural Use of Aluminium BSI

Part 1: Code Of Practice For Design


Part 2: Specification For Materials, Workmanship And Protection
C. Glazing
BS 6262 - 3:2005: Glazing For Building

Material
The aluminium profiles are extruded profiles, extruded as per the following BS namely:
BS 3987 For Anodised Profiles
BS 3900 For Powder Coated
Basic Alloy
The basic alloy for the extruded aluminium profile is the Alloy 6063 T5 to BS 1474.

Physical Properties
Alloy (AA Designation) As Per BS 6063
Temper, T T5
Ultimate strength 131 N/mm2
Yield Strength 68 N/mm2
Modulus Of Elasticity, E 70 N/mm2
Ultimate Shear strength 110 N/mm2
Density 2700 Kg/m3 #######
Design Methodology
The Extruded aluminium profile sections will be checked for the permissible deflection as well as
for load carrying capacity.
An allowable deflection of span/175 (Single - Glazed) will be used.
This limiting value for deflection is critical for glazing generally, though conservative for the extruded
aluminium profiles themselves. It is therefore conservative.

The following checks will be carried out:


Permissible Deflection Of Mullion And Transom At Serviceability Limit State
Moment Capacity At Ultimate Limit State
Composite Action, where appropriate
Glazing Thickness
Fixing Frame To Concrete
PROJECT: ONE & ONLY LE SAINT GERAN
DATE: 19-Jun-2019

Page No.: 1

A.0. WIND LOAD CALCULATION - CP3


Basic Wind Speed, V = 280 Km/h
77.78 m/s
Cladding Class = A
Cladding Class A is adopted since wind actions will be checked on all units of glazings and their intermediate fixings.
The maximum horizontal dimension of building does not exceed 50m.
Height above local ground floor level = 3 m (Gfloor) Assumption 1
Ground Roughness, S2 = 0.83 (For Terrain Category 1)
Topographical Factor , S1 = 1 (Building is an inland building with no valley)
Statistical Factor , S3 = 1
Design Wind Pressure, Vs = VxS1xS2xS3 = 64.56 m/s
Dynamic Wind Pressure, Vd = 0.613 x Vs =
2
2.55 KN/m2

A.1. BUILDING GEOMETRY


Largest Plan Dimension, l = m
Shortest Plan Dimension, w = m
Building Height , h = m
Building Height Ratio, h/w = - 1/2 < h/w < 3/2
Building Plan Ratio, l /w = - 1 < l/w < 3/2

WIND
ANGLE, Cpe Cpi Cpi-Cpe Cpe Cpi Cpi-Cpe Local, Cp
α

0 0.2 -0.3 -1 Assumption 2


90 0.2 -0.3 -1

Design Positive Pressure =(Cpi-Cpe )x Vd = 0.00 KN/m2


Design Negative Pressure = (Cpi-Cpe) x Vd = 0.00 6/19/2019
Design Local Suction = Cp x Vd = -2.55 KN/m2

A.2. SUMMARY OF DESIGN WIND LOADS:

HEIGHT DESIGN DESIGN - DESIGN


FLOOR ABOVE LGFL +VE VE LOCAL
ITEM NO
LEVEL TO TOP OF PRESSURE PRESSURE SUCTION
OPENING (m) (KN/m2) (KN/m2) (KN/m2)
1 GF 3 -2.55
1 GF 6 -3.00
PROJECT: ONE & ONLY LE SAINT GERAN
DATE: 19-Jun-2019

Page No.: 2

A.0. WIND LOAD CALCULATION - CP3


Basic Wind Speed, V = 280 Km/h
77.78 m/s
Cladding Class = A
Cladding Class A is adopted since wind actions will be checked on all units of glazings and their intermediate fixings.
The maximum horizontal dimension of building does not exceed 50m.
Height above local ground floor level = 6 m (FF) Assumption 1
Ground Roughness, S2 = 0.9 (For Terrain Category 1)
Topographical Factor , S1 = 1 (Building is an inland building with no valley)
Statistical Factor , S3 = 1
Design Wind Pressure, Vs = VxS1xS2xS3 = 70.00 m/s
Dynamic Wind Pressure, Vd = 0.613 x Vs =
2
3.00 KN/m2

A.1. BUILDING GEOMETRY


Largest Plan Dimension, l = m
Shortest Plan Dimension, w = m
Building Height , h = m
Building Height Ratio, h/w = - 1/2 < h/w < 3/2
Building Plan Ratio, l /w = - 1 < l/w < 3/2

WIND
ANGLE, Cpe Cpi Cpi-Cpe Cpe Cpi Cpi-Cpe Local, Cp
α

0 0.2 -0.3 -1 Assumption 2


90 0.2 -0.3 -1

Design Positive Pressure =(Cpi-Cpe )x Vd = 0.00 KN/m2


Design Negative Pressure = (Cpi-Cpe) x Vd = 0.00 6/19/2019
Design Local Suction = Cp x Vd = -3.00 KN/m2

A.2. SUMMARY OF DESIGN WIND LOADS:

HEIGHT DESIGN DESIGN - DESIGN


FLOOR ABOVE LGFL +VE VE LOCAL
ITEM NO
LEVEL TO TOP OF PRESSURE PRESSURE SUCTION
OPENING (m) (KN/m2) (KN/m2) (KN/m2)
1 GF 3 -2.55
1 FF 6 -3.00
PROJECT: ONE & ONLY LE SAINT GERAN
DATE: 19-Jun-2019

Page No: 4

A. OPENING REF: AD01 - OPTION 1 - LAMINATED GLASS

DESCRIPTION

Structural Module is a 3-leaf sliding door. Vertical member equally spaced at 1616mm c/c.

Overall width is 4820mm wide and 2565 mm high as per architect drawing.

LOCATION: GF

DESCRIPTION OF MEMBERS :
ITEM NO. MEMBER REF.OF PROFILES REMARK
1 M1 S590103 Interlocking Profiles 2Nos

B. DESIGN OF GLAZING THICKNESS


Width 1616 mm
Height a 2.565 m (clear height)
Width b 1.62 m
Glazing supported on 4 sides Yes Use Chart from BS 6262-3:2005
Glazing Supported on 3 sides No Use Chart from ASTM:E1300-12a
Glazing supported on 2 sides No Use Chart from ASTM:E1300-12a
2
Area A 4.15 m
r 1.59
F 0.948
Effective Area 3.93 m2
Design Wind Pressure -2.55 KN/m2
From Figure 6 (BS 6262-3: 2005 ), Glass Thickness, t = 12.38 mm
6/19/2019
Page No.: 5
C.0 DESIGN OF MEMBER M1
C.1. LOADING
lx 1.616 m
ly 2.565 m (Clear Span)
ly/lx 1.59 < 2 (Two - Way load Transfer)
n 2.55 KN/m2
Udl at M1 = (1/3)*n*Lx*(3-(lx/ly)2)
3.58 KN/m

Actual Moment , Mact 3.54 KNm F.0.S = 1. 2

C.2. APPARTIONMENT OF LOADING


Ixx of S590103 = 126.00 cm4 (Refer to data sheet)
Ixx of S590103 = 126.00 cm4 (Refer to data sheet)
Young Modulus, E 70000.00 N/mm2
Ixx(Stiffener) of Steel Stiffener = 0.00 cm4 (No Stiffener)
Young Modulus of Steel, E 200000.00 N/mm2

ΣEI= 1.76E+11 Nmm2


Fraction of load taken by S590103 = EIS590103/ΣEI= 0.50 F
Fraction of load taken by S590103 = EIS590103/ΣEI = 0.50 F
Fraction of load taken by Stiffener = EIxx(Stiffener) /ΣEI = 0.00 F

C.3. MOMENT AND DEFLECTION CHECK


Depth to Neutral Axis (S590103) = 60 mm
Depth to Neutral Axis (S590103) = 60 mm

Limiting Stress in Bending, Po 110 N/mm2


Material Factor of Safety F= 1.2
Moment Capacity of S590129 Mo Po x Z
Mo 1.93 kNm
Moment, M = Fraction x Load
M= 1.77 kNm < 1.93 KNm
Section Adequate

Deflection d = (5qsa4)/(384EI)
d= 11.4 mm
span/175
Permissible Deflection, dp (For single laminated glass )
dp 14.7 mm

Deflection check OK
Page No. 6
D.0. CHECK CONNECTION
TO CONCRETE
UDL @ top & Bottom edge = 3.28 KN/m
Capacity of 4.8mm Dia Screw = 1.60 KN
(Refer To Attached Spec)
No of screw required = 2 per metre
Use screw at a spacing of 250mm c/c along perimeter of opening
Total number of screws provided = 20 Along Top & Bot. Edges
Total number of screws provided = 9 Along Vertical Edges
PROJECT: ONE & ONLY LE SAINT GERAN
DATE: 19-Jun-2019

Page No: 7

A. OPENING REF: AD01 - OPTION 2 - DOUBLE GLAZED

DESCRIPTION

Structural Module is a 3-leaf sliding door. Vertical member equally spaced at 1616mm c/c.

Overall width is 4820mm wide and 2565 mm high as per architect drawing.

LOCATION: GF

DESCRIPTION OF MEMBERS :
ITEM NO. MEMBER REF.OF PROFILES REMARK
1 M1 NEW HD PROFILE Interlocking Profiles 2Nos

B. DESIGN OF GLAZING THICKNESS


Width 1616 mm
Height a 2.565 m (clear height)
Width b 1.62 m
Glazing supported on 4 sides Yes Use Chart from BS 6262-3:2005
Glazing Supported on 3 sides No Use Chart from ASTM:E1300-12a
Glazing supported on 2 sides No Use Chart from ASTM:E1300-12a
2
Area A 4.15 m
r 1.59
F 0.948
Effective Area 3.93 m2
Design Wind Pressure -2.55 KN/m2
From Figure 11 (BS 6262-3: 2005 ), Glass Thickness, t = 6L + 10T mm
Page No.: 8
C.0 DESIGN OF MEMBER M1
C.1. LOADING
lx 1.616 m
ly 2.565 m (Clear Span)
ly/lx 1.59 < 2 (Two - Way load Transfer)
n 2.55 KN/m2
Udl at M1 = (1/3)*n*Lx*(3-(lx/ly)2)
3.58 KN/m

Actual Moment , Mact 3.54 KNm F.0.S = 1. 2

C.2. APPARTIONMENT OF LOADING


Ixx of HD NEW = 208.00 cm4 (Refer to data sheet)
Ixx of HD NEW = 208.00 cm4 (Refer to data sheet)
Young Modulus, E 70000.00 N/mm2
Ixx(Stiffener) of Steel Stiffener = 0.00 cm4 (No Stiffener)
Young Modulus of Steel, E 200000.00 N/mm2

ΣEI= 2.91E+11 Nmm2


Fraction of load taken by S59129 = EIHD/ΣEI= 0.50 F
Fraction of load taken by S59129 = EIHD/ΣEI = 0.50 F
Fraction of load taken by Stiffener = EIxx(Stiffener) /ΣEI = 0.00 F

C.3. MOMENT AND DEFLECTION CHECK


Depth to Neutral Axis (HD NEW) = 72 mm
Depth to Neutral Axis (HD NEW) = 72 mm

Limiting Stress in Bending, Po 110 N/mm2

Material Factor of Safety F= 1.2


Moment Capacity of S590129 Mo Po x Z
Mo 2.65 kNm
Moment, M = Fraction x Load
M= 1.77 kNm < 2.65 KNm
Section Adequate

Deflection d = (5qsa4)/(384EI)
d= 6.9 mm
Permissible Deflection, dp
span/250
dp 10.3 mm

Deflection check OK
Page No. 9
D.0. CHECK CONNECTION
TO CONCRETE
UDL @ top & Bottom edge = 3.28 KN/m
Capacity of 4.8mm Dia Screw = 1.60 KN
(Refer To Attached Spec)
No of screw required = 2 per metre
Use screw at a spacing of 250mm c/c along perimeter of opening
Total number of screws provided = 20 Along Top & Bot. Edges
Total number of screws provided = 9 Along Vertical Edges
PROJECT: ONE & ONLY LE SAINT GERAN
DATE: 19-Jun-2019

Page No: 10

A. OPENING REF: AW55 - OPTION 1 - LAMINATED GLASS

DESCRIPTION

Structural Module comprises 4 fix panels with vertical member M1 equally spaced at 1442 mm c/c.

Overall width is 5765mm wide and 2565 mm high as per architect drawing.

LOCATION: FF

DESCRIPTION OF MEMBERS :
ITEM NO. MEMBER REF.OF PROFILES REMARK
1 M1 S480043 1 NOS

B. DESIGN OF GLAZING THICKNESS


Width 1442 mm
Height a 2.565 m (clear height)
Width b 1.44 m
Glazing supported on 4 sides Yes Use Chart from BS 6262-3:2005
Glazing Supported on 3 sides No Use Chart from ASTM:E1300-12a
Glazing supported on 2 sides No Use Chart from ASTM:E1300-12a
2
Area A 3.70 m
r 1.78
F 0.921
Effective Area 3.41 m2
Design Wind Pressure -3.00 KN/m2
From Figure 6 (BS 6262-3: 2005 ), Glass Thickness, t = 12.38 mm
Page No.: 11
C.0 DESIGN OF MEMBER M1
C.1. LOADING
lx 1.442 m
ly 2.565 m (Clear Span)
ly/lx 1.78 < 2 (Two - Way load Transfer)
n 3.00 KN/m2
Udl at M1 = (1/3)*n*Lx*(3-(lx/ly)2)
3.88 KN/m

Actual Moment , Mact 3.82 KNm F.0.S = 1. 2


Reaction at Ends, R1 11.93 kN F.0.S = 1. 2
C.2. APPARTIONMENT OF LOADING
Ixx of S480043 = 279.31 cm4 (Refer to data sheet)
Ixx of S5480043 = 0.00 cm4 (Refer to data sheet)
Young Modulus, E 70000.00 N/mm2
Ixx(Stiffener) of Steel Stiffener = 0.00 cm4 (No Stiffener)
Young Modulus of Steel, E 200000.00 N/mm2

ΣEI= 1.96E+11 Nmm2


Fraction of load taken by S480043 = EIS590129/ΣEI= 1.00 F
Fraction of load taken by S480043 = EIS590129/ΣEI = 1.00 F
Fraction of load taken by Stiffener = EIxx(Stiffener) /ΣEI = 0.00 F

C.3. MOMENT AND DEFLECTION CHECK


Depth to Neutral Axis (S480043) = 75 mm
Depth to Neutral Axis (S480043) = 75 mm

Limiting Stress in Bending, Po 110 N/mm2

Material Factor of Safety F= 1.2


Moment Capacity of S480043 Mo Po x Z
Mo 3.41 kNm
Moment, M = Fraction x Load
M= 3.82 kNm < 3.41 KNm
Section Adequate

Deflection d = (5qsa4)/(384EI)
d= 11.2 mm
Permissible Deflection, dp
span/175 (For single laminated glass)
dp 14.7 mm

Deflection check OK

C.4. CHECK CONNECTION @ ENDS


Reaction at Ends, R1 11.93 kN F.0.S = 1. 2
Use 2 No. M10 FBN 11 ANCHOR BOLTS each of shear capacity of 12.0KN into 4.5mm Thk GMS bracket.
Page No. 12
D.0. CHECK CONNECTION
TO CONCRETE
UDL @ left vertical edge = 1.94 KN/m
Capacity of 4.8mm Dia Screw = 1.60 KN
(Refer To Attached Spec)
No of screw required = 1 per metre
Use screw at a spacing of 250mm c/c along perimeter of opening
Total number of screws provided = 11 Along vertical Edges
Total number of screws provided = 23 Along at top & bot edge.
PROJECT: ONE & ONLY LE SAINT GERAN
DATE: 19-Jun-2019

Page No: 13

A. OPENING REF: AW55 - OPTION 2 - DOUBLE GLAZED

DESCRIPTION

Structural Module comprises 4 fix panels with vertical member M1 equally spaced at 1442 mm c/c.

Overall width is 5765mm wide and 2565 mm high as per architect drawing.

LOCATION: FF

DESCRIPTION OF MEMBERS :
ITEM NO. MEMBER REF.OF PROFILES REMARK
1 M1 S480045 1 NOS

B. DESIGN OF GLAZING THICKNESS


Width 1442 mm
Height a 2.565 m (clear height)
Width b 1.44 m
Glazing supported on 4 sides Yes Use Chart from BS 6262-3:2005
Glazing Supported on 3 sides No Use Chart from ASTM:E1300-12a
Glazing supported on 2 sides No Use Chart from ASTM:E1300-12a
2
Area A 3.70 m
r 1.78
F 0.921
Effective Area 3.41 m2
Design Wind Pressure -3.00 KN/m2
From Figure 110(BS 6262-3: 2005 ), Glass Thickness, t = 6L+10T mm
Page No.: 14
C.0 DESIGN OF MEMBER M1
C.1. LOADING
lx 1.442 m
ly 2.565 m (Clear Span)
ly/lx 1.78 < 2 (Two - Way load Transfer)
n 3.00 KN/m2
Udl at M1 = (1/3)*n*Lx*(3-(lx/ly)2)
3.88 KN/m

Actual Moment , Mact 3.82 KNm F.0.S = 1. 2


Reaction at Ends, R1 11.93 kN F.0.S = 1. 2
C.2. APPARTIONMENT OF LOADING
Ixx of S480045 = 501.00 cm4 (Refer to data sheet)
Ixx of S5480045 = 0.00 cm4 (Refer to data sheet)
Young Modulus, E 70000.00 N/mm2
Ixx(Stiffener) of Steel Stiffener = 0.00 cm4 (No Stiffener)
Young Modulus of Steel, E 200000.00 N/mm2

ΣEI= 3.51E+11 Nmm2


Fraction of load taken by S480043 = EIS590129/ΣEI= 1.00 F
Fraction of load taken by S480043 = EIS590129/ΣEI = 1.00 F
Fraction of load taken by Stiffener = EIxx(Stiffener) /ΣEI = 0.00 F

C.3. MOMENT AND DEFLECTION CHECK


Depth to Neutral Axis (S480045) = 100 mm
Depth to Neutral Axis (S480045) = 100 mm

Limiting Stress in Bending, Po 110 N/mm2

Material Factor of Safety F= 1.2


Moment Capacity of S480045 Mo Po x Z
Mo 4.59 kNm
Moment, M = Fraction x Load
M= 3.82 kNm < 4.59 KNm
Section Adequate

Deflection d = (5qsa4)/(384EI)
d= 6.2 mm
Permissible Deflection, dp
span/250 (For Double Glazed)
dp 10.3 mm

Deflection check OK

C.4. CHECK CONNECTION @ ENDS


Reaction at Ends, R1 11.93 kN F.0.S = 1. 2
Use 2 No. M10 FBN 11 ANCHOR BOLTS each of shear capacity of 12.0KN into 4.5mm Thk GMS bracket.
Page No. 15
D.0. CHECK CONNECTION
TO CONCRETE
UDL @ left vertical edge = 1.94 KN/m
Capacity of 4.8mm Dia Screw = 1.60 KN
(Refer To Attached Spec)
No of screw required = 1 per metre
Use screw at a spacing of 250mm c/c along perimeter of opening
Total number of screws provided = 11 Along vertical Edges
Total number of screws provided = 23 Along at top & bot edge.
PROJECT: ONE & ONLY LE SAINT GERAN
DATE: 19-Jun-2019

Page No: 16

A. OPENING REF: AD10 - OPTION 1 - LAMINATED GLASS

DESCRIPTION

Structural module comprises with 4 fix glazed panels and 1 single leaf wooden door 1.4m wide.

Overall width is 5765mm wide and 2565 mm high as per architect drawing.

LOCATION: GF

DESCRIPTION OF MEMBERS :
ITEM NO. MEMBER REF.OF PROFILES REMARK
1 M1 S480045 1 NOS
M2 GMS RHS 120X40X4.5 1 NOS

B. DESIGN OF GLAZING THICKNESS


Width 1332 mm
Height a 2.565 m (clear height)
Width b 1.33 m
Glazing supported on 4 sides Yes Use Chart from BS 6262-3:2005
Glazing Supported on 3 sides No Use Chart from ASTM:E1300-12a
Glazing supported on 2 sides No Use Chart from ASTM:E1300-12a
2
Area A 3.42 m
r 1.93
F 0.900
Effective Area 3.07 m2
Design Wind Pressure -2.55 KN/m2
From Figure 6 (BS 6262-3: 2005 ), Glass Thickness, t = 12.38 mm
Page No.: 17
C.0 DESIGN OF MEMBER M1
C.1. LOADING
lx 1.322 m
ly 2.565 m (Clear Span)
ly/lx 1.94 < 2 (Two - Way load Transfer)
n 2.55 KN/m2
Udl at M1 = (1/3)*n*Lx*(3-(lx/ly)2)
3.07 KN/m

Actual Moment , Mact 3.03 KNm F.0.S = 1. 2


Reaction at Ends, R1 9.46 kN F.0.S = 1. 2
C.2. APPARTIONMENT OF LOADING
Ixx of S480043 = 279.31 cm4 (Refer to data sheet)
Ixx of S5480043 = 0.00 cm4 (Refer to data sheet)
Young Modulus, E 70000.00 N/mm2
Ixx(Stiffener) of Steel Stiffener = 0.00 cm4 (No Stiffener)
Young Modulus of Steel, E 200000.00 N/mm2

ΣEI= 1.96E+11 Nmm2


Fraction of load taken by S480043 = EIS590129/ΣEI= 1.00 F
Fraction of load taken by S480043 = EIS590129/ΣEI = 1.00 F
Fraction of load taken by Stiffener = EIxx(Stiffener) /ΣEI = 0.00 F

C.3. MOMENT AND DEFLECTION CHECK


Depth to Neutral Axis (S480043) = 75 mm
Depth to Neutral Axis (S480043) = 75 mm

Limiting Stress in Bending, Po 110 N/mm2

Material Factor of Safety F= 1.2


Moment Capacity of S480043 Mo Po x Z
Mo 3.41 kNm
Moment, M = Fraction x Load
M= 3.03 kNm < 3.41 KNm
Section Adequate

Deflection d = (5qsa4)/(384EI)
d= 8.9 mm
Permissible Deflection, dp
span/175 (For single laminated glass)
dp 14.7 mm

Deflection check OK

C.4. CHECK CONNECTION @ ENDS


Reaction at Ends, R1 9.46 kN F.0.S = 1. 2
Use 2 No. M10 FBN 11 ANCHOR BOLTS each of shear capacity of 12.0KN into 4.5mm Thk GMS bracket.
Page No. 18
D.0. DESIGN OF MEMBER M2 - GMS RHS 120X40X4.5
D.1. LOADING
lx 1.322 m
ly 2.565 m (Clear Span)
ly/lx 1.94 < 2 (Two - Way load Transfer)
n 2.55 KN/m2
Udl at M1 = (1/3)*n*Lx*(3-(lx/ly)2)
3.07 KN/m

Actual Moment , Mact 3.03 KNm F.0.S = 1. 2


Reaction at Ends, R1 9.46 kN F.0.S = 1. 2

D.2. MOMENT AND DEFLECTION CHECK


Second Moment of Inertia , Ixx = 1.82E+06 mm4
Plastic Modulus of Elasticity, Sxx = 4.04E+04 mm3
Allowable bending stress of Steel , Py = 275 N/mm2
F 1.2
Mo = Py Sxx
Mo = 11.11 kNm

< Mact 3.03 KNm


Moment Capacity OK
4
Actual Deflection, d = (5qsa )/(384EI)
d= 4.6 mm

Permissible Deflection, dp = span/200


dp 12.8 mm
Deflection OK

C.4. CHECK CONNECTION @ ENDS


Reaction at Ends, R1 9.46 kN F.0.S = 1. 2
Use 2 No. M10 FBN 11 ANCHOR BOLTS each of shear capacity of 12.0KN into 6mm Thk Baseplate.
PROJECT: ONE & ONLY LE SAINT GERAN
DATE: 19-Jun-2019

Page No: 18

A. OPENING REF: AD10 - OPTION 2 - DOUBLE GLAZED

DESCRIPTION

Structural module comprises with 4 fix glazed panels and 1 single leaf wooden door 1.4m wide.

Overall width is 5765mm wide and 2565 mm high as per architect drawing.

LOCATION: GF

DESCRIPTION OF MEMBERS :
ITEM NO. MEMBER REF.OF PROFILES REMARK
1 M1 S480045 1 NOS
M2 GMS RHS 120X40X4.5 1 NOS

B. DESIGN OF GLAZING THICKNESS


Width 1332 mm
Height a 2.565 m (clear height)
Width b 1.33 m
Glazing supported on 4 sides Yes Use Chart from BS 6262-3:2005
Glazing Supported on 3 sides No Use Chart from ASTM:E1300-12a
Glazing supported on 2 sides No Use Chart from ASTM:E1300-12a
2
Area A 3.42 m
r 1.93
F 0.900
Effective Area 3.07 m2
Design Wind Pressure -2.55 KN/m2
From Figure 11 (BS 6262-3: 2005 ), Glass Thickness, t = 6L+10T mm
Page No.: 19
C.0 DESIGN OF MEMBER M1
C.1. LOADING
lx 1.322 m
ly 2.565 m (Clear Span)
ly/lx 1.94 < 2 (Two - Way load Transfer)
n 2.55 KN/m2
Udl at M1 = (1/3)*n*Lx*(3-(lx/ly)2)
3.07 KN/m

Actual Moment , Mact 3.03 KNm F.0.S = 1. 2


Reaction at Ends, R1 9.46 kN F.0.S = 1. 2
C.2. APPARTIONMENT OF LOADING
Ixx of S480045 = 501.00 cm4 (Refer to data sheet)
Ixx of S5480043 = 0.00 cm4 (Refer to data sheet)
Young Modulus, E 70000.00 N/mm2
Ixx(Stiffener) of Steel Stiffener = 0.00 cm4 (No Stiffener)
Young Modulus of Steel, E 200000.00 N/mm2

ΣEI= 3.51E+11 Nmm2


Fraction of load taken by S480043 = EIS590129/ΣEI= 1.00 F
Fraction of load taken by S480043 = EIS590129/ΣEI = 1.00 F
Fraction of load taken by Stiffener = EIxx(Stiffener) /ΣEI = 0.00 F

C.3. MOMENT AND DEFLECTION CHECK


Depth to Neutral Axis (S480045) = 100 mm
Depth to Neutral Axis (S480045) = 100 mm

Limiting Stress in Bending, Po 110 N/mm2

Material Factor of Safety F= 1.2


Moment Capacity of S480045 Mo Po x Z
Mo 4.59 kNm
Moment, M = Fraction x Load
M= 3.03 kNm < 4.59 KNm
Section Adequate

Deflection d = (5qsa4)/(384EI)
d= 4.9 mm
Permissible Deflection, dp
span/250 (For Double Glazed )
dp 10.3 mm

Deflection check OK

C.4. CHECK CONNECTION @ ENDS


Reaction at Ends, R1 9.46 kN F.0.S = 1. 2
Use 2 No. M10 FBN 11 ANCHOR BOLTS each of shear capacity of 12.0KN into 4.5mm Thk GMS bracket.
Page No. 20
D.0. DESIGN OF MEMBER M2 - GMS RHS 120X40X4.5
D.1. LOADING
lx 1.322 m
ly 2.565 m (Clear Span)
ly/lx 1.94 < 2 (Two - Way load Transfer)
n 2.55 KN/m2
Udl at M1 = (1/3)*n*Lx*(3-(lx/ly)2)
3.07 KN/m

Actual Moment , Mact 3.03 KNm F.0.S = 1. 2


Reaction at Ends, R1 9.46 kN F.0.S = 1. 2

D.2. MOMENT AND DEFLECTION CHECK


Second Moment of Inertia , Ixx = 1.82E+06 mm4
Plastic Modulus of Elasticity, Sxx = 4.04E+04 mm3
Allowable bending stress of Steel , Py = 275 N/mm2
F 1.2
Mo = Py Sxx
Mo = 11.11 kNm

< Mact 3.03 KNm


Moment Capacity OK
4
Actual Deflection, d = (5qsa )/(384EI)
d= 4.6 mm

Permissible Deflection, dp = span/200


dp 12.8 mm
Deflection OK

C.4. CHECK CONNECTION @ ENDS


Reaction at Ends, R1 9.46 kN F.0.S = 1. 2
Use 2 No. M10 FBN 11 ANCHOR BOLTS each of shear capacity of 12.0KN into 6mm Thk Baseplate.