Professional Documents
Culture Documents
DATE: 20-Dec-2022
Page No.: 1
Cladding Class A is adopted since wind actions will be checked on all units of glazings and their intermediate fixings.
The maximum horizontal dimension of building does not exceed 50m.
Height above local ground floor level = `18 m
Ground Roughness, S2 = 1.01 CAT 2
Topographical Factor , S1 = 1 (Building is an inland building with no valley)
Statistical Factor , S3 = 1
WIND
ANGLE, Cpe Cpi Cpe-Cpi Cpe Cpi Cpe-Cpi Local, Cp
α
Page No.: 1
P3 Panel P1 Panel
P1 P4
where,
hk = Thickness of plies within a laminated sheet
hm;k = distance of mid-plane of the glass plies
w= Coefficient of shear transfer of PVB (Family 2) = 0.3
hk = 8 mm
hm;k = 4.19 mm
Therefore,
hef,w = 11.86 mm
EFFECTIVE THICKNESS FOR BENDING STRESS
Using IStruE(APPENDIX 3) , effective thickness hef;j for bending stress:
hef;J = 12.60 mm
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 26-Jan-2023
Page No.: 2
CHECK DEFLECTION
Ixx = (d3hef;w)/12 840.22 cm4
Span, l = 2450.00 mm
Actual Deflection, dact = (5wl4)/(384*E*Ixx) 1.47 mm
Allowable deflection = span/60 = 40.83 mm
Allowable Bending Stress for Annealed Glass
Page No.: 3
#NAME?
SUMMARY OF RESULTS
Actual deflection, Dact = 3.097 mm
Actual moment, Mact = 7.10 KNm (Unfactored)
Reaction at ends, R1 = 6.39 KN (Unfactored)
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 20-Dec-2022
Page No.: 4
CHECK DEFLECTION
Clear Span of member M1 = 5800 mm
Allowable deflection, Dall = 5800/200 = 29.00 mm > Actual Deflection
Therefore, Deflection OK
CHECK MOMENT
Bending Strength, py 235.00 Nmm2
Moment Capacity, M0 = Py Sxx 34.78 KNm
Moment at ULS = 1.4 x 7.10 = 9.94 KN < M0
Therefore, Moment OK
Distance of Lf to centroid of weld 0.15 mm Distance of weld taken from centre of weld in compression to
Applied moment = 7.10 KNm centroid of weld in tension.
Tension at flange = M/Lf = 47 KN
Using fillet weld 6mm, a = 6 mm pw = 220 N/mm2
Throat thickness, a = 0.7a = 4.2 mm
Weld capacity, P = pw a = 924.00 N/mm
Length of weld = 570.00 mm (Double side (6mmx2) -(3x90mm int= 570mm)
Total weld capacity 526.68 KN
>47 KN
Therefore, 6mm weld is adequate.
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 28-Feb-2022
Page No.: 5
D CHECK MEMBER M1
Loading from Panel P1 on M1 = 1.84 KN/m
Point load from Member T1 & T2 = 2 x 6.39 12.78 KN
Moment from Member T1 & T 2 = 2 x 7.10 14.2 KNm
SUMMARY OF RESULTS
Actual deflection, Dact = 5.21 mm
Actual moment, Mact = 14.45 KNm (Unfactored)
Reaction at ends, R1 = 9.65 KN (Unfactored)
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 28-Feb-2022
Page No.: 6
CHECK DEFLECTION
Clear Span of member M1 = 3020 mm
Allowable deflection, Dall = 3020/200 = 15.10 mm > Actual Deflection
Therefore, Deflection OK
CHECK MOMENT
Bending Strength, py 235.00 Nmm2
Moment Capacity, M0 = Py Sxx 0.00 KNm
Moment at ULS = 1.4 x 7.10 = 9.94 KN < M0
Therefore, Moment OK
Use 2 Nos M10 FBN II Fisher Anchor Bolt each of capacity 12.0 KN into 6mm GMS plate welded to RHS
Page No.: 7
Page No.: 8
p3
T1 T2
P1 P2
p4
where,
hk = Thickness of plies within a laminated sheet
hm;k = distance of mid-plane of the glass plies
w= Coefficient of shear transfer of PVB (Family 2) = 0.3
hk = 8 mm
hm;k = 4.19 mm
Therefore,
hef,w = 11.86 mm
EFFECTIVE THICKNESS FOR BENDING STRESS
Using IStruE(APPENDIX 3) , effective thickness hef;j for bending stress:
hef;J = 12.60 mm
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 26-Jan-2023
Page No.: 9
CHECK DEFLECTION
Ixx = (d3hef;w)/12 840.22 cm4
Span, l = 2450.00 mm
Actual Deflection, dact = (5wl4)/(384*E*Ixx) 1.32 mm
Allowable deflection = span/175 = 14.00 mm
Allowable Bending Stress for Annealed Glass
Page No.: 10
SUMMARY OF RESULTS
Actual deflection, Dact = 9.93 mm
Actual moment, Mact = 15.13 KNm (Unfactored)
Reaction at ends, R1 = 11.53 KN (Unfactored)
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 20-Dec-2022
Page No.: 11
CHECK DEFLECTION
Clear Span of member M1 = 6100 mm
Allowable deflection, Dall = 6100/200 = 30.50 mm > Actual Deflection
Therefore, Deflection OK
CHECK MOMENT
Bending Strength, py 235.00 Nmm2
Moment Capacity, M0 = Py Sxx 34.78 KNm
Moment at ULS = 1.4 x15.13= 21.18 KN < M0
Therefore, Moment OK
Distance of Lf to centroid of weld 0.15 mm Distance of weld taken from centre of weld in compression to
Applied moment = 15.13 KNm centroid of weld in tension.
Tension at flange = M/Lf = 101 KN
Using fillet weld 6mm, a = 6 mm pw = 220 N/mm2
Throat thickness, a = 0.7a = 4.2 mm
Weld capacity, P = pw a = 924.00 N/mm
Length of weld = 570.00 mm (Double side (6mmx2) -(3x90mm int= 570mm)
Total weld capacity 526.68 KN
>101 KN
Therefore, 6mm weld is adequate.
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 28-Feb-2022
Page No.: 12
D CHECK MEMBER M1
Loading from Panel P1 & P2 on M1 = (1.9*0.5*0.871) + (1.2*1.9*0.5) 1.97 KN/m
Point load from Member T1 11.53 KN
Moment from Member T1 15.13 KNm
2
Point load from MemberT2 = [(1/6 x 1.9x1.02x (3-(1.02/1.2) ) + (1/3x1.2X1.9 )] x 1.2 x 0.5 0.90 KN conservative
Udl from panel P3 = 1/3 x 1.02*1.9 = 0.37 KN/m
PROPOSED SECTION - RHS 200X100X4
BENDING PROPERTIES
Bending strength, Py = 235.00 N/mm2
Moment of inertia about major axis, Ixx = 12.00 x 10 6 mm4
Plastics modululs, Sxx = 148.00 x 103 mm3
Young Modulus of elasticity, E = 205000.00 Nmm2
SUMMARY OF RESULTS
Actual deflection, Dact = 8.034 mm
Actual moment, Mact = 21.67 KNm (Unfactored)
Reaction at ends, R1 = 11.13 KN (Unfactored)
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 28-Feb-2022
Page No.: 13
CHECK DEFLECTION
Clear Span of member M1 = 3520 mm
Allowable deflection, Dall = 3520/200 = 17.60 mm > Actual Deflection
Therefore, Deflection OK
CHECK MOMENT
Bending Strength, py 235.00 Nmm2
Moment Capacity, M0 = Py Sxx 34.78 KNm
Moment at ULS = 1.4 x21.67 = 30.34 KN < M0
Therefore, Moment OK
Use 2 Nos M10 FBN II Fisher Anchor Bolt each of capacity 12.0 KN into 6mm GMS plate welded to RHS
Page No.: 14
Page No.: 15
Page No.: 16
DESIGN OF MEMBER T1
LOADING
Point load from member M1 = 1.59 KN
Udl from panel P1 = 0.5X1.02x1.9 = 0.97 KN/m
LOADING
SUMMARY OF RESULTS
Actual deflection, Dact = 16.81 mm
Actual moment, Mact = 14.72 KNm (Unfactored)
Max Reaction at ends, R1 = 9.82 KN (Unfactored)
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 26-Jan-2023
Page No.: 17
CHECK DEFLECTION
Clear Span of member M1 = 5270 mm
Allowable deflection, Dall = 5270/200 = 26.35 mm > Actual Deflection
Therefore, Deflection OK
CHECK MOMENT
Bending Strength, py 235.00 Nmm2
Moment Capacity, M0 = Py Sxx 34.78 KNm
Moment at ULS = 1.4 x14.72 = 20.61 KNm < M0
Therefore, Moment OK
Use 2 Nos M10 FBN II Fisher Anchor Bolt each of capacity 12.0 KN into 6mm GMS plate welded to RHS
CONSIDERING PANEL P2
Height a 2.4 m
Width b 1.318 m
Glazing supported on 4 sides Yes Use Chart from BS 6262-3:2005
Glazing Supported on 3 sides No Use Chart from ASTM:E1300-12a
Glazing supported on 2 sides No Use Chart from ASTM:E1300-12a
Area A 3.16 m2
Aspect
1.82
Ratio,
Shape
Factor, 0.915
F
Effective Area 2.90 m2
Design Wind Pressure 1.90 KN/m2
From BS 6262-3: 2005 chart , Glass Thickness, t = 10.38 mm is adequate.
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 26-Jan-2023
Page No.: 18
Page No.: 19
P1 P1
T1
M2
P3
P2 M1
B DESIGN OF MEMBER M1
CHECK MOMENT CAPACITY AND DEFLECTION
Member M1 (door sash) is reinforced with vertical cyclonic bar GMS 80x40x3
Page No.: 20
B DESIGN OF MEMBER T1
LOADING
Point load from member M1 = 2.50 KN
Udl from panel P1 = 0.5X1.02x1.9 = 0.97 KN/m
Page No.: 21
SUMMARY OF RESULTS
Actual deflection, Dact = 4.39 mm
Actual moment, Mact = 9.26 KNm (Unfactored)
Max Reaction at ends, R1 = 8.28 KN (Unfactored)
CHECK DEFLECTION
Clear Span of member M1 = 5180 mm
Allowable deflection, Dall = 5180/200 = 25.90 mm > Actual Deflection
Therefore, Deflection OK
CHECK MOMENT
Bending Strength, py 235.00 Nmm2
Moment Capacity, M0 = Py Sxx 34.78 KNm
Moment at ULS = 1.4 x9.26 = 12.97 KNm < M0
Therefore, Moment OK
Distance of Lf to centroid of weld 0.15 mm Distance of weld taken from centre of weld in compression to
Applied moment = 9.26 KNm centroid of weld in tension.
Tension at flange = M/Lf = 62 KN
Using fillet weld 6mm, a = 6 mm pw = 220 N/mm2
Throat thickness, a = 0.7a = 4.2 mm
Weld capacity, P = pw a = 924.00 N/mm
Length of weld = 570.00 mm (Double side (6mmx2) -(3x90mm int= 570mm)
Total weld capacity 526.68 KN
>62 KN
Therefore, 6mm weld is adequate.
Use 2 Nos M10 FBN II Fisher Anchor Bolt each of capacity 12.0 KN into 6mm GMS plate welded to RHS
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 20-Dec-2022
Page No.: 22
C DESIGN OF MEMBER M1
UDL from panel P2 = 0.878 X 1.9 = 1.67 KN/m
2
UDL from panel P3 = (1/6)x2.03x1.9x(3- (2.03/2.63) 3.09 KN/m
Total Udl = 4.76 KN/m
Point load from T2 = 2.86 KN
Point load from T1 8.28 KN
Total Point load = 11.13 KN
Moment induced due to T2 = 1.16 KNm
Moment induced due to T1= 9.26 KNm
Total moment = 10.42 KNm
SUMMARY OF RESULTS
Actual deflection, Dact = 5.12 mm
Actual moment, Mact = 16.19 KNm (Unfactored)
Reaction at ends, R1 = 15.13 KN (Unfactored)
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 28-Feb-2022
Page No.: 23
CHECK DEFLECTION
Clear Span of member M1 = 3700 mm
Allowable deflection, Dall = 3700/200 = 18.50 mm > Actual Deflection
Therefore, Deflection OK
CHECK MOMENT
Bending Strength, py 235.00 Nmm2
Moment Capacity, M0 = Py Sxx 34.78 KNm
Moment at ULS = 1.4 x16.19 = 22.67 KN < M0
Therefore, Moment OK
Use 2 Nos M10 FBN II Fisher Anchor Bolt each of capacity 12.0 KN into 6mm GMS plate welded to baseplate
Page No.: 24
CONSIDERING PANEL P1
Height a 2.6 m
Width b 0.97 m
Glazing supported on 4 sides Yes Use Chart from BS 6262-3:2005
Glazing Supported on 3 sides No Use Chart from ASTM:E1300-12a
Glazing supported on 2 sides No Use Chart from ASTM:E1300-12a
2
Area A 2.51 m
Aspect Ratio, r 2.66
Shape Factor, F 0.794
Effective Area 1.99 m2
Design Wind Pressure 1.90 KN/m2
From BS 6262-3: 2005 chart , Glass Thickness, t = 8.38 mm is adequate.
Page No.: 25
Page No.: 26
PANEL P4
P4 P3
T2 T1
P2
P1 P3
where,
hk = Thickness of plies within a laminated sheet
hm;k = distance of mid-plane of the glass plies
w= Coefficient of shear transfer of PVB (Family 2) = 0.3
hk = 8 mm
hm;k = 4.19 mm
Therefore,
hef,w = 11.86 mm
EFFECTIVE THICKNESS FOR BENDING STRESS
Using IStruE(APPENDIX 3) , effective thickness hef;j for bending stress:
hef;J = 12.60 mm
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 26-Jan-2023
Page No.: 27
CHECK DEFLECTION
Ixx = (d3hef;w)/12 840.22 cm4
Span, l = 2450.00 mm
Actual Deflection, dact = (5wl4)/(384*E*Ixx) 1.52 mm
Allowable deflection = span/175 = 14.00 mm
Allowable Bending Stress for Annealed Glass
Page No.: 28
SUMMARY OF RESULTS
Actual deflection, Dact = 0.613 mm
Actual moment, Mact = 3.75 KNm (Unfactored)
Max. Reaction at ends, R1 = 5.50 KN (Unfactored)
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 20-Dec-2022
Page No.: 29
CHECK DEFLECTION
Clear Span of member M1 = 3000 mm
Allowable deflection, Dall = 3000/200 = 15.00 mm > Actual Deflection
Therefore, Deflection OK
CHECK MOMENT
Bending Strength, py 235.00 Nmm2
Moment Capacity, M0 = Py Sxx 34.78 KNm
Moment at ULS = 1.4 x3.75= 5.25 KN < M0
Therefore, Moment OK
Distance of Lf to centroid of weld 0.15 mm Distance of weld taken from centre of weld in compression to
Applied moment = 3.75 KNm centroid of weld in tension.
Tension at flange = M/Lf = 25 KN
Using fillet weld 6mm, a = 6 mm pw = 220 N/mm2
Throat thickness, a = 0.7a = 4.2 mm
Weld capacity, P = pw a = 924.00 N/mm
Length of weld = 570.00 mm (Double side (6mmx2) -(3x90mm int= 570mm)
Total weld capacity 526.68 KN
>25 KN
Therefore, 6mm weld is adequate.
Use 2 Nos M10 FBN II Fisher Anchor Bolt each of capacity 12.0 KN into 6mm GMS plate welded to RHS
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 28-Feb-2022
Page No.: 30
D CHECK MEMBER M1
Loading from Panel P1 & P2 on M1 = (0.5*1.2*1.9)+(0.5*1.0*1.9) = 2.09 KN/m
2
Udl from Panel P3 = (1/6 x 1.2 x1.9x(3-(1.2/1.248) ) 0.81 KN/m
Point load from Member T2 =[(1/3 x 1.9x1.2x 2)]X1.2X0.5 0.91 KN
Point load from Member T1 = 5.50 KN
Udl from panel P2 on T2 = (1/3)x1.2x1.9 = 0.76 KN/m
Moment transferred from T1 = 3.75 KN/m
2
Moment transferred at T2 = (0.76x1.2 )/12 = 0.09 KNm
PROPOSED SECTION - RHS 200X100X4
BENDING PROPERTIES
Bending strength, Py = 235.00 N/mm2
Moment of inertia about major axis, Ixx = 12.00 x 10 6 mm4
Plastics modululs, Sxx = 148.00 x 103 mm3
Young Modulus of elasticity, E = 205000.00 Nmm2
SUMMARY OF RESULTS
Actual deflection, Dact = 5.366 mm
Actual moment, Mact = 10.88 KNm (Unfactored)
Reaction at ends, R1 = 7.00 KN (Unfactored)
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 28-Feb-2022
Page No.: 31
CHECK DEFLECTION
Clear Span of member M1 = 3833 mm
Allowable deflection, Dall = 3833/200 = 19.17 mm > Actual Deflection
Therefore, Deflection OK
CHECK MOMENT
Bending Strength, py 235.00 Nmm2
Moment Capacity, M0 = Py Sxx 34.78 KNm
Moment at ULS = 1.4 x10.88= 15.23 KN < M0
Therefore, Moment OK
Use 2 Nos M10 FBN II Fisher Anchor Bolt each of capacity 12.0 KN into 6mm GMS plate welded to RHS
Page No.: 32
Page No.: 33
LOADING
Design wind load = 1.90 KN/m2
Panel width = 1500 mm
Panel Height = 2500 mm (clear span)
UDL @ M2 = (1/3)x1.5x1.9x(3-(1.5/2.595)2 2.51 kN/m
A CHECK MEMBER M2
BENDING PROPERTIES - M2 - AWH150 B (2 NOS)
Ixx = 143 cm4 (refer to annexe)
Young Modulus, E = 70000 N/mm2
Limiting Stress Due to Bending, P0= 110 N/mm2
Material Factor of safety, F = 1.2
Depth to Neutral axis, d 64.81 mm (Refer to annexe)
Moment capacity, M0 = (P0 x Z)/F = 2.02 KNm
CHECK MOMENT
Actual moment, M = 1.2 x wl2 / 8 = 2.35 KNm
2 Nos of AWH 150B provided.
Actual moment per AWH150B = M/2 = 1.18 KNm
< Mo
Therefore, Moment capacity OK
CHECK DEFLECTION
Actual Deflection of AWH 150B, dact = 0.5 x (5wl4)/(384*E*Ixx) 12.74 mm
Allowable deflection, span/175 = 14.29 mm
Therefore, deflection OK
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 26-Jan-2023
Page No.: 34
CONSIDERING PANEL P3
Design Wind pressure = 1.90 KN/m2
Exposed Glass Height , H 2.595 m
Exposed Glass Width, W 1.500 m
Glazing supported on 4 sides Yes Use Chart from BS 6262-3:2005
Glazing Supported on 3 sides No Use Chart from ASTM:E1300-12a
Glazing supported on 2 sides No Use Chart from ASTM:E1300-12a
2
Area A 3.89 m
Aspect Ratio, r 1.73
Shape Factor F 0.93
Effective Area Ae 3.61 m2
Page No.: 35
T1 T2
FS01 and FS01 are at corner connected to with a vertical GMS SHS 200x200x4
Page No.: 36
DESIGN OF MEMBER T1
LOADING 2.88
Point load from member M1 = 2.49 KN
Udl from panel P1 & P2 = (1/3X1.18x1.9) + (1/6)x1.18x1.9x(3-(1.18/2.4)2 = 2.56 KN/m
Point load from M2 = (1/3) x 1.112 x 1.9x1.115 x0.5 = 0.39 KN
SUMMARY OF RESULTS
Actual deflection, Dact = 19.72 mm
Actual moment, Mact = 31.22 KNm (Unfactored)
Max Reaction at ends, R1 = 20.70 KN (Unfactored)
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 26-Jan-2023
Page No.: 37
CHECK DEFLECTION
Clear Span of member M1 = 7125 mm
Allowable deflection, Dall = 7125/200 = 35.63 mm > Actual Deflection
Therefore, Deflection OK
CHECK MOMENT
Bending Strength, py 235.00 Nmm2
Moment Capacity, M0 = Py Sxx 50.06 KNm
Moment at ULS = 1.4 x31.22 = 43.71 KNm < M0
Therefore, Moment OK
D DESIGN OF MEMBER M1
LOADING
Point load from T1 20.7 KN
Udl from Panel P1 = 1.03 KN/m (Applied along full height, therefore conservative)
Moment from T1 = 31.22 KNm
SUMMARY OF RESULTS
Actual deflection, Dact = 7.56 mm
Actual moment, Mact = 38.96 KNm (Unfactored)
Reaction at ends, R1 = 17.16 KN (Unfactored)
CHECK DEFLECTION
Clear Span of member M1 = 3612 mm
Allowable deflection, Dall = 3612/200 = 18.06 mm > Actual Deflection
CHECK MOMENT
Bending Strength, py 235.00 Nmm2
Moment Capacity, M0 = Py Sxx 77.55 KNm
Moment at ULS = 1.4 x10.88= 54.54 KN < M0
Therefore, Moment OK
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 20-Dec-2022
Page No.: 40
Page No.: 41
SUMMARY OF RESULTS
Actual deflection, Dact = 11.62 mm
Actual moment, Mact = 3.91 KNm unfactored
Shear Force at extremities, F 10.80 KN unfactored
DESIGN CHECKS
CHECK DEFLECTION
Clear Span of member M1 = 3125 mm Clear span
Allowable deflection, Dall = 3125/250 = 12.50 mm < Actual deflection =11.62mm
Page No.: 42
CHECK MOMENT
Ixx = 68 cm4 (refer to annexe)
Young Modulus, E = 70000 N/mm2
Limiting Stress Due to Bending, P0= 110 N/mm2
Material Factor of safety, F = 1.2
Depth to Neutral axis, d 50.00 mm
Moment capacity, M0 = (P0 x Z)/F = 1.26 KNm
CHECK DEFLECTION
Actual deflection = 5wL4 / 384 EI = 2.83 mm
Allowable deflection = Span /250 = 5.26 mm
Since actual < allowable deflection, Deflection OK
CHECK CONNECTION OF T3 TO M1
Design Shear Force, Fv = 3.49X1.315X0.5 = 2.29 KN
T1 is connected to M1 via 3mm Thk Alu. Shear Block.
Shear capacity of 4.8mm Self tapping screw fixing shear block to T1 = 1.32 KN (FOS = 2) Refer to Annexe
2 Nos 4.2mm dia screw provided = 2.63 KN
> Shear Force, Therefore OK
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 20-Dec-2022
Page No.: 43
E CHECK CONNECTION
CONNECTION OF MEMBER M1
Maximum Reaction, R1 = 10.8 KN
Design shear force, Fv = 1.2 * 10 = 12.0 KN
CONNECTION AT TOP
Use 1 Nos M10 FBN II Fisher Anchor Bolt each of capacity 12.0 KN into 4.5mm THk GMS Bracket
CONNECTION AT BOTTOM
Use 2 Nos M10 FBN II Fisher Anchor Bolt each of capacity 12.0 KN into 4.5mm THk GMS Bracket
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 28-Feb-2022
Page No.: 44
Page No.: 45
Page No.: 46
SUMMARY OF RESULTS
Actual deflection, Dact = 8.23 mm
Actual moment, Mact = 2.82 KNm unfactored
Shear Force at extremities, F 5.67 KN unfactored
DESIGN CHECKS
CHECK DEFLECTION
Clear Span of member M1 = 3125 mm Clear span
Allowable deflection, Dall = 3125/250 = 12.50 mm < Actual deflection =11.62mm
Page No.: 47
CHECK MOMENT
Ixx = 68 cm4 (refer to annexe)
Young Modulus, E = 70000 N/mm2
Limiting Stress Due to Bending, P0= 110 N/mm2
Material Factor of safety, F = 1.2
Depth to Neutral axis, d 50.00 mm
Moment capacity, M0 = (P0 x Z)/F = 1.26 KNm
CHECK DEFLECTION
Actual deflection = 5wL4 / 384 EI = 1.68 mm
Allowable deflection = Span /250 = 5.26 mm
Since actual < allowable deflection, Deflection OK
CHECK CONNECTION OF T3 TO M1
Design Shear Force, Fv = 2.07X1.315X0.5 = 1.36 KN
T1 is connected to M1 via 3mm Thk Alu. Shear Block.
Shear capacity of 4.8mm Self tapping screw fixing shear block to T1 = 1.32 KN (FOS = 2) Refer to Annexe
2 Nos 4.2mm dia screw provided = 2.63 KN
> Shear Force, Therefore OK
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 20-Dec-2022
Page No.: 48
E CHECK CONNECTION
CONNECTION OF MEMBER M1
Maximum Reaction, R1 = 5.7 KN
Design shear force, Fv = 1.2 * 10 = 12.0 KN
CONNECTION AT TOP
Use 1 Nos M10 FBN II Fisher Anchor Bolt each of capacity 12.0 KN into 4.5mm THk GMS Bracket
CONNECTION AT BOTTOM
Use 2 Nos M10 FBN II Fisher Anchor Bolt each of capacity 12.0 KN into 4.5mm THk GMS Bracket
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 28-Feb-2022
Page No.: 48
By inspection on the above, calculation note also caters for the followings openings:
STEEL GLASS TYPE/
ITEM FLOOR VERTICAL HORIZONTAL OVERALL NO OF WIDTH PER HEIGHT
PLOT REFEREENCE INSERT IN GLASS
NO LEVEL MEMBER MEMBER WIDTH (MM) PANEL PANEL (MM) (MM)
MULLION THICKNESS
1 55 W01 FF - AWT60 - 10TL+ AG + 8T 1200 1 1200 3145
Page No.: 49
P4
P3
M1
P1 P2
Page No.: 50
SUMMARY OF RESULTS
Actual deflection, Dact = 3.03 mm
Actual moment, Mact = 3.14 KNm unfactored
Shear Force at extremities, F 8.89 KN unfactored
DESIGN CHECKS
CHECK DEFLECTION
Clear Span of member M1 = 3020 mm
Allowable deflection, Dall = 3020/250 = 12.08 mm < Actual deflection =3.03mm
Page No.: 51
CHECK DEFLECTION
Actual deflection = 5wL4 / 384 EI = 1.76 mm
Allowable deflection = Span /250 = 4.80 mm
Since actual < allowable deflection, Deflection OK
E CHECK CONNECTION
CHECK CONNECTION OF T1 TO M1
Design Shear Force, Fv = 1.83*1.35*0.5*1.2 = 2.12 KN
T1 is connected to M1 via 3mm Thk Alu. Shear Block.
Shear capacity of 4.8mm Self tapping screw fixing shear block to T1 = 1.32 KN (FOS = 2) Refer to Annexe
2 Nos 4.2mm dia screw provided = 2.63 KN
> Shear Force, Therefore OK
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 20-Dec-2022
Page No.: 52
CONNECTION OF MEMBER M1
Maximum Reaction, R1 = 8.9 KN
Design shear force, Fv = 1.2 * 8.9 = 10.7 KN
CONNECTION AT TOP
Use 1 Nos M10 FBN II Fisher Anchor Bolt each of capacity 12.0 KN into 4.5mm THk GMS Bracket
CONNECTION AT BOTTOM
Use 2 Nos M10 FBN II Fisher Anchor Bolt each of capacity 12.0 KN into 4.5mm THk GMS Bracket
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 28-Feb-2022
Page No.: 53
By inspection on the above notes, calculation also caters for following openings as per table below:
GLASS TYPE/ OVERALL
ITEM VERTICAL HORIZONTAL STEEL INSERT NO OF WIDTH PER HEIGHT
PLOT REFEREENCE FLOOR LEVEL GLASS WIDTH
NO MEMBER MEMBER IN MULLION PANEL PANEL (MM) (MM)
THICKNESS (MM)
1 55 W13 SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 2400 2 1200 3020
2 55 W14 SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 3380 3 1127 3020
3 55 W15 SF - AWT60 - 10TL+ AG + 8T 1200 1 1200 3020
4 55 W15A SF - AWT60 - 10TL+ AG + 8T 1200 1 1200 3020
6 55 W17 SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 3600 3 1200 3020
6 55 W17a SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 3856 3 1285 2920
6 55 w17b SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 2916 2 1458 2920
6 55 W18 SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 4415 4 1104 2920
6 55 SF18 SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 8806 7 1258 3145
6 56 W05 SF - AWT60 - 10TL+ AG + 8T 1200 1 1200 2570
6 56 W06 SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 2475 2 1238 2945
6 56 w06a SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 5000 4 1250 2945
6 56 W06b SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 2500 2 1250 2946
6 56 W06c SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 5000 4 1250 2945
6 56 W06d SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 2475 2 1238 2945
6 56 W07 SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 2475 2 1238 2945
6 56 W03d SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 5000 4 1250 3145
6 56 W03c SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 5000 4 1250 3145
6 56 W03d SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 5000 4 1250 3145
6 56 W04 SF - AWT60 - 10TL+ AG + 8T 1200 1 1200 3145
6 56 SF03 SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 6970 4 1743 3145
6 56 W01 SF - AWT60 - 10TL+ AG + 8T 1200 1 1200 2720
6 56 w02 SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 2475 2 1238 3145
6 56 w02a SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 2475 2 1238 3145
6 56 w02b SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 2500 2 1250 3145
6 56 w02c SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 2475 2 1238 3145
6 56 W03 SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 2475 2 1238 3145
6 56 W03a SF AWT 140 AWT60 37X130X30X3 10TL+ AG + 8T 2500 2 1250 3145
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 1-Feb-2023
Page No.: 54
A OPENING REFERENCE: SF 26
Page No.: 55
SUMMARY OF RESULTS
Actual deflection, Dact = 12.57 mm
Actual moment, Mact = 3.85 KNm unfactored
Shear Force at extremities, F 12.61 KN unfactored
DESIGN CHECKS
CHECK DEFLECTION
Clear Span of member M1 = 3245 mm
Allowable deflection, Dall = 3245/250 = 12.98 mm < Actual deflection =12.57mm
Page No.: 56
CHECK DEFLECTION
Actual deflection = 5wL4 / 384 EI = 0.93 mm
Allowable deflection = Span /250 = 5.72 mm
Since actual < allowable deflection, Deflection OK
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 20-Dec-2022
Page No.: 57
E CHECK CONNECTION
CONNECTION OF MEMBER M1 & M2
Maximum Reaction, R1 = 12.6 KN
Design shear force, Fv = 1.2 * 12.6 = 15.1 KN
CONNECTION AT TOP
Use 1 Nos M12 FBN II Fisher Anchor Bolt each of capacity 17.8 KN into 4.5mm THk GMS Bracket
CONNECTION AT BOTTOM
Use 2 Nos M10 FBN II Fisher Anchor Bolt each of capacity 12.0 KN into 4.5mm THk GMS Bracket
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 28-Feb-2022
Page No.: 58
CHECK CONNECTION OF T2 TO M1
Design shear Force , Fv = 1.2 x 3.22 = 3.86 KN
Shear capacity of 4.8mm Self tapping screw = 1.78 KN (FOS = 2) Refer to Annexe
Capacity of 3 Nos. 4.8mm self tapping screw = 5.34 KN
> Fv
Therefore use 3 Nos Self tapping screw into 3mm thick Tight Fit Bracket
Page No.: 59
Page No.: 60
Deflection Check
Aspect Ratio = A/B= 1.53
Area of glass = A*B = 3.77 m2
Maximum wind load in single glass LITE 2 = W/LS = 1.61 KN/m2
Load x Area2 22.82 KNm2
Maximum wind load in single glass LITE 1 = W/LS = 2.88 KN/m2 Deflection on Lite 1 =
Load x Area2 40.96 KNm2 18 mm
PROJECT: MIXED USE DEVELOPMENT AT TELFAIR, MOKA
DATE: 20-Dec-2022
Page No.: 61
Deflection on Lite 2 = 22 mm
Allowable deflection = 1570 / 60 = 26 mm
Ratio of deflection limit = 0.84 < 1
Therefore, deflection OK
By inspection on the above notes, calculation also for following openins as per table below:
1 55 S28 TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 7650 7 1093 3245
2 55 S28a TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 7650 7 1093 3245
4 55 w23 TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 1143 1 1143 3245
5 55 W24 TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 4415 3 1472 3245
7 55 SF23 TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 5207 5 1041 3245
8 55 SF24 TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 5346 5 1069 3245
9 55 SF25 TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 4580 4 1145 3245
10 55 SF26 TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 10019 7 1431 3245
11 55 SF27 TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 6505 6 1084 3245
12 55 SF18 TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 8806 6 1468 3145
13 55 sf19 TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 15723 12 1310 3145
14 56 SF19 TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 15725 12 1310 3245
15 56 W19 TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 4175 3 1392 3245
16 56 SF21 TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 4580 4 1145 3245
17 56 SF21A TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 32226 3 10742 3245
18 56 W21 TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 1986 2 993 3245
19 56 SF22 TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 5309 5 1062 3245
20 56 SF22a TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 3406 3 1135 3245
21 56 w07 TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 2500 2 1250 3245
22 56 w07b TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 5000 4 1250 3245
23 56 w07c TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 5000 4 1250 3245
24 56 w07a TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 2475 2 1238 3245
25 56 w08 TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 1200 1 1200 3245
26 56 sf05 TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 5745 4 1436 3245
27 56 sf06 TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 6680 6 1113 3245
28 56 sf06a TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 6665 6 1111 3245
29 56 sf07 TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 3565 3 1188 3245
30 56 sf08 TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 6475 6 1079 3245
31 56 sf09 TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 7650 6 1275 3245
32 56 sf09a TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 7650 6 1275 3245
33 56 sf09b TF AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 7650 6 1275 3245
34 56 SF10 AWT 140 AWT 140 AWT 110 37X130X30X6 10TL+ AG + 8T 7245 7 1035 3245