You are on page 1of 3

EXPERIMENT-4

Aim: - Study of Single Phase Digital /Electronic Energy meter and calibrate it.

Apparatus Required:- NV7025 Single Phase Energy Meter

Theory :

NV7025 Single Phase Energy Meter Demonstrator describes a high accuracy, low cost, single-phase
energy meter. The meter is designed for use in single-phase, 2-wire distribution systems. The design can
be adapted to suit specific regional requirements, e.g., in USA, power is usually distributed for
residential customers as single-phase, 3-wire.

This is a highly integrated system comprised of two ADCs, a reference circuit and a fixed DSP function
for the calculation of real power. A highly stable oscillator is integrated into the design to provide the
necessary clock for the IC. This includes direct drive capability for LCD Display and a high frequency
pulse output for Calibration.

Features:
1. Micro controller based LCD display.
2. The display acts as a counter of units consumed as well as it shows the wattage of load and the time
since the system has been ON.
3. Easy diagrammatic representation of Energy Meter.
4. Test points are provided to measure the voltages at different points.
5. Low Cost Trainer with high accuracy, demonstrating all the basic concepts of Single Phase Energy
Measurement.
6. Good quality, reliable sockets are provided at appropriate places on board for electric board supply
and load connections.

TABLE:
S.No Potentiometer Position Unit Indicate Time
1 I
2 II
3 III
4 VI
8 V
RESULT:

PRECAUTION:-
Use proper Mains cord : Use only the mains cord designed for this instrument.
Ensure that the mains cord is suitable for your
Ground the Instrument :
This instrument is grounded through the protective earth conductor of the mains cord. To
avoid electric shock the grounding conductor must be connected to the earth ground. Before
making connections to the input terminals, ensure that the instrument is properly grounded.
Observe Terminal Ratings :
To avoid fire or shock hazards, observe all ratings and marks on the instrument.
Use only the proper Fuse :
Use the fuse type and rating specified for this instrument.
Use in proper Atmosphere :
Please refer to operating conditions given in the manual.
1. Do not operate in wet / damp conditions.
2. Do not operate in an explosive atmosphere.
3. Keep the product dust free, clean and dry.

You might also like