www.elster.com
H4000 Woltmann
cold water meters
The H4000 is a Woltmann-type meter designed
for measuring bulk flows of cold potable water
for revenue billing in commercial or industrial
applications and distribution system monitoring.
Key features Available in ten sizes for flow rates Flexible installation
between 0.35 m3/h and 2000 m3/h,
● Inductive register for improved output Installation can be in horizontal, vertical
the H4000 operates at temperatures
performance and security and inclined pipelines. The H4000 also
up to 50°C and a maximum working
● Extended low and high achieves good performance in
pressure of 16 bar. Accuracy is
flow performance abnormal installations.
maintained in both forward and
● Suitable for forward and reverse flow, and the product offers
reverse flow metering the benefits of inductive-based Intelligent metering
pulse communications technology. Fully compatible with Elster’s Emeris
● Robust shroud and copper can register
The meter complies with all relevant range of intelligent meter reading
for long-life and clear readability
international quality standards, systems, H4000 can provide even more
● Longer wear life for optimum accuracy vital management information to assist
substantially exceeding ISO4064 BS5728
● Exceeds Class B specification in Class B specifications for forward flow with effective distribution management,
forward direction and for sizes up installations in horizontal, vertical and reduce water losses from leakage and
to 150mm in reverse direction inclined pipelines. improve customer service. When
combined with the Emeris TRC600 unit
Reverse flow metering (pictured below), a range of intelligent
features including leakage alarms,
Available in sizes up to 150mm,
datalogging and tariffs enables
reverse flow metering aids network
a complete metering system that
management and ensures accuracy in
addresses the efficiency objectives for
revenue billing applications.
water providers.
Robust construction
Like all Elster meters, the H4000 is
manufactured from the highest quality
materials for maximum resistance to
wear and corrosion. Meter body
and cover are epoxy powder
coated for protection in
all environments.
Thrust pads and
stub spindles are
manufactured in
tungsten carbide
and jewelled rotor
bearings are used
for maximum wear life.
All wetted materials are
UK WRAS approved
against health risk.
1
Reliable connectivity
The H4000 uses an inductive register
to deliver enhanced communications
performance and tamper proof security,
offering protection against fraud. The
H4000 is compatible with the Emeris PR7
inductive pulse transmitter, and offers
both high and low speed bi-directional
pulse capabilities as standard. The PR7
is fully compatible with other common
ancillary devices including dataloggers
and AMR systems.
8507D4245
H4000 Woltmann Cold Water Meters Product Specification
C
B
Accuracy Curve, Head Loss Curve and Pulse Connectivity shown overleaf
H4000 Woltmann Cold Water Meters Product Specification
0
2%
5%
qmin qt qp qs
RATE OF FLOW (m3/h)
& 1 25mm
m
mm
mm
mm
0.8 0.8
40m
50m
0m
0m
00
00
15
20
0.6 0.6
1
&3
mm
m
0m
0.4 0.4
80
25
HEADLOSS (BARS)
(bars)
0.2 0.2
HEADLOSS
0.1 0.1
0.08 0.08
0.06 0.06
0.04 0.04
0.02 0.02
0.01 0.01
2 4 6 8 2 3 4 6 8 2 4 6 8
10 100 1000 10000
x10 x10
x100 x10
x1000
RATE OF FLOW (m3/h)
Pulse Connectivity
Calculating Pulse Weights when fitted with PR7 inductive pulser
Pulse Weight is calculated by multiplying the Register ‘Pulse Factor’ (P) by the PR7 ‘K-Factor’ (K)
Pulse Weight (Litres per Pulse) = P x K 1
PR7 is an Open Collector pulse transmitter suitable for datalogging, AMR and telemetry equipment. 1 On the PR7 unit the user can identify
Check with your equipment supplier for full details of compatibility. from the label the K-Factors for each
output channel
2 Primary Output K-Factor
8507D4346
Copyright Elster Metering Limited 2008 Note: Specifications are subject to change without notice.