Remsdaq Callisto NX System Scada Brochure PDF
Remsdaq Callisto NX System Scada Brochure PDF
FEATURES
Flexibility & Re
2
...Full Computerised Substation Control System
LAN Protocols
• DNP3
energy edition energy edition • IEC60870-5-104
• IEC61850
• Modbus
FEATURES
Bay Control Units Typically Feature:
• Transducerless AC connections • Redundant gateways and time sources
• High accuracy measurements (0.1% fsd) • I/O optimised to bay requirements
• Integrated protection functions • Supports both Station and Process buses
• Fault data measurements up to 50 times over current • Support of serial and IEC 61850 IEDs
• Fault data in Comtrade format • Open connectivity using industry standard protocols
• Secure controls • Local HMI option
• Local autonomous automation
• High accuracy SOE (1ms system wide)
• Integration of serial IEDs into an
IEC61850 environment
Power Supply:
• Integrated power supply unit (non-isolated: 24V DC,
isolated: 12V, 24V, 48V, 110V, 125V and 220V DC options)
LCD:
• High contrast 128x64 pixel display
Dimensions:
• 286mm x 255mm x 149mm
Options
1
12V (8–18V), 24V (16–36V), 48V (30–72V), 110V (75–170V) and 220V (150–300V). 2Unipolar 0 to 20mA. 3Unipolar or bipolar, 0 to ±5V or 0 to ±20mA.
4
Engineers Tool Kit
nx
nx
nx
Web Server
Viewnx, an integrated web server, makes it possible to browse Callistonx
locally or remotely to access performance and operation. Access is
achieved using secure user and password identification on platform
independent browsers such as Explorer 7, Firefox and Netscape. Viewnx
enables the secure modification of the unit’s configuration parameters
and supports comprehensive diagnostic facilities for monitoring,
exercising controls and viewing communications activities.
5
Compliances
EMC Environmental
General Conducted Immunity General
• IEC 60870-2-1 • IEC 61000-4-6 (Level 3) • IEC 60870-2-2 (Class C3)
• IEC 61000-4-16 (Level 4)
Fast Transient Bursts Temperature
• IEC 61000-4-4 Harmonic Emissions/Flicker • IEC 60068-2-1 (–40°C)
(Level 4, PSU: Level X, 4kV) • IEC 61000-3-2 • IEC 60068-2-2 (+70°C)
• IEC 801-4 (Level 4) • IEC 60068-2-14 (1°C/min)
Magnetic Field Immunity
• IEC 60255-22-4 (Class 4)
• IEC 61000-4-8 (Level 4) Relative Humidity (non-condensing)
• ANSI/IEEE C37.90.1
• IEC 60068-2-3 (95% at 40°C, 10 days)
Pulse Magnetic Field
Oscillatory Transient IEC 60068-2-30 (55°C, 6 days)
• IEC 61000-4-9 (Level 5)
• IEC61000-4-12 (ring wave:
Level 4, oscillatory wave: Level 3) Composite Temperature/Humidity
Damped Oscillatory Magnetic Field
• ANSI/IEEE C37.90.1 • IEC 60068-2-38
• IEC 61000-4-10 (Level 4)
• IEC 60255-22-1 (Class 3) Air Pressure
Operating Voltage • IEC 60068-2-13 (55kPa and 110kPa)
Surge Immunity • IEC60255-6
• IEC 61000-4-5 (Level 4, AC Vibration
voltage inputs: Level 4 & Class 5) Voltage Dips/Fluctuations • IEC 60068-2-6 (2g)
• IEC 61000-4-11 • EC 60255-21-1 (Class 2)
High Voltage Impulse • IEC 61000-3-3
• IEC 60060-1 (5kV, 0.5J) Shock
DC Supply Interruption • IEC 60068-2-27 (15g)
Insulation and Isolation • IEC 60255-11 • IEC 60068-2-29 (15g)
• IEC 60255-5 (rated insulation 500V, • IEC 61000-4-29 • IEC 60255-21-2 (Class 2)
2.5kV dielectric, 5kV impulse)
AC Ripple on DC Supply Seismic
Electrical Disturbances • IEC 60255-11 (12%) • IEC 60255-21-3 (Class 2)
• IEC 60255-22-1 (Class 3) • IEC 61000-4-17 (Level 4)
Free Fall Test (non-operational)
Electrostatic Discharge Generic Immunity • IEC 60068-2-32
• IEC 61000-4-2 (Level 4) • EN 50082-1
• IEC 60255-22-2 (Class 4)
Generic Immunity Industrial Environment
Radiated Immunity • IEC 61000-6-2
• IEC 61000-4-3 (Level X, 35V/m)
• IEC 60255-22-3 (Class 3) Radio Disturbance Conducted & Radiated
• IEC 801-3 (Class 3) • EN 55022 (Class B) installed in
• ENV 50204 (Level X, 35V/m) typical enclosure
• IEEE C37.90.2 Low Voltage Directive
• 93/68/EEC