You are on page 1of 8

Cycle-Tempo 5.0 (Build 481) c:\users\ridho\documents\62797_orc-r245ca-pdrop05%-m03\versi akhir.

gui

CCC Y Y CCC L EEEEE TTTTT EEEEE M M PPPP OOOO


C C Y Y C C L E T E MM MM P P O O
C Y Y C L E T E M M M M P P O O
C Y C L EEEEE === T EEEEE M M M PPPP O O
C Y C L E T E M M P O O
C C Y C C L E T E M M P O O
CCC Y CCC LLLLL EEEEE T EEEEE M M P OOOO

Cycle-Tempo : Thermodynamic Energysystems, Massflow calculation for POwerprocesses

Delft University of Technology (TU Delft)

Mechanical, Maritime and Materials Engineering (3mE) Faculty

Energy Technolgy Section

Leeghwaterstraat 44

2628 CA Delft, The Netherlands

Release 5.0 (Build 481) (Intel Fortran 9.1.037)

Problem name : c:\users\ridho\documents\62797_orc-r245ca-pdrop05%-m03\versi akhir

Problem description : Description

System time : 16:54:55

System date : 29/05/2020

May 29, 2020 17:00:46 Page 1 of 8


Cycle-Tempo 5.0 (Build 481) c:\users\ridho\documents\62797_orc-r245ca-pdrop05%-m03\versi akhir.gui

CONFIGURATION OF THE INSTALLATION


=================================

NUMBER OF APPARATUS NAPP = 10


NUMBER OF PIPES (LINKS) NLIN = 14
NUMBER OF THERMAL CYCLES NCYCLE = 3
TOTAL NUMBER OF TURBINES NTURB = 1
NUMBER OF TURBINE DRIVEN PUMPS NTDP = 0
NUMBER OF ABSORTION CYCLES NABSOR = 0
NUMBER OF GENERATORS NUMGEN = 1
NUMBER OF PRODUCTION FUNCTIONS NPRODF = 2
LOAD CONDITION CODE NDLOAD = 0 =0: DESIGN LOAD RUN
>0: PART LOAD RUN, NDLOAD=NUMBER OF PARTLOAD CONDITIONS (&PARTLD)
DESIGN LOAD FACTOR DFACTR =1.000000
OUTPUT CONTROL CODE NPRINT = 4
0=EXTENSIVE OUTPUT
1=ALSO PUNCH PARTLOAD DATA
2=COMPREHENSIVE OUTPUT
3=MORE COMPREHENSIVE OUTPUT
4=SHORTENED OUTPUT
ADDITIONAL OUTPUT CONTROL CODE NXXX = 0
NUMBER OF TRACED APPARATUS NTRACE = 10

MIN. NUMBER OF MAIN ITERATIONS MINITM = 0


MAX. NUMBER OF MAIN ITERATIONS MAXITM = 25
ADD. NUMBER OF MAIN ITERATIONS MORITM = 0
UNDERRELAXATION INHIBITED AFTER MAXUR = 25 STEPS
ACCURACY FOR ITERATION EPS =0.000100
ELECTRICAL FREQUENCY FREQ = 50.0 HZ

STORAGE USED FOR GENERAL COMMON AREA = 13466 WORDS OF 4 BYTES

State functions for water/steam calculations:


IAPWS Industrial Formulation 1997 (IAPWS-IF97)

NUMBER OF EQUATIONS
====================

NUMBER OF PRIMARY MASS EQUATIONS = 10 NUMBER OF APPARATUS 10 MINUS SINKS WITHOUT MASS EQUATION 0

NUMBER OF SECONDARY MASS EQUATIONS = 4 NUMBER OF TWO MEDIA APPARATUS TYPES 4,5,6,12,20,21,22,23

NUMBER OF PRESCRIBED MASS EQUATIONS = 0 NUMBER OF TYPES 14,21,25,26,28 AND FOR CERTAIN CONDITIONS: 13,20,22,23

NUMBER OF AUTOMATIC ENERGY EQUATIONS = 1 NUMBER OF TYPES 5,7,11,15 AND IF EEQCOD EQUALS 1: 4,20,21,22,23

NUMBER OF EXPLICIT ENERGY EQUATIONS = 2 NUMBER OF PRODUCTION FUNCTIONS

MINUS THE NUMBER OF CLOSED CYCLES = 3 (NUMBER OF OPEN CYCLES = 0)

PLUS THE NUMBER OF ABSORPTION CYCLES = 0

MAKES TOGETHER 14 AND NLIN = 14


---------------------------------

Cycle-Tempo iteration 0:
--------------------------

Cycle-Tempo iteration 1:
--------------------------

May 29, 2020 17:00:46 Page 2 of 8


Cycle-Tempo 5.0 (Build 481) c:\users\ridho\documents\62797_orc-r245ca-pdrop05%-m03\versi akhir.gui

Main iteration convergence data


===============================

--------------------------------------------------------------------
| | Massflows |
|Iter.|------------------------------------------------------------|
| no. | num. pipes maximum pipe max. maximum pipe max. |
| | no conver. abs. dev. abs. dev. rel. dev. rel. dev. |
|-----|------------------------------------------------------------|
| 1 | 0 0.00 1 0.00 1 |
--------------------------------------------------------------------

Convergence reached in 1 iterations.


--------------------------------------
Absolute deviation massflow:
Criterion absolute deviation: < .100E-02
Max absolute deviation in pipe 1: 0.00
Relative deviation in this pipe: 0.00
Relative deviation massflow:
Criterion relative deviation: < 0.100E-03
Max relative deviation in pipe 1: 0.00
Absolute deviation in this pipe: 0.00

SYSTEM EFFICIENCIES, POWER INPUT AND OUTPUT


===========================================

-----------------------------------------------------------------------
| || NO APPARATUS TYPE | ENERGY TOTALS |
| || | [kW] [kW] |
|=====================================================================|
| ABSORBED || 6 Reheater 2 | 73299.49 |
| POWER || | 73299.49 |
|---------------------------------------------------------------------|
| DELIVERED || 1 GENERATOR | 10000.00 |
| GROSS POWER || | 10000.00 |
|---------------------------------------------------------------------|
| AUX.POWER || 4 Pump 8 | 586.95 |
| CONSUMPTION || 11 Pump 8 | -12.84 |
| || 12 Pump 8 | 0.00 |
| || | 574.11 |
|---------------------------------------------------------------------|
| DELIVERED || | |
| NET POWER || | 9425.89 |
|=====================================================================|
| EFFICIENCIES|| GROSS | 13.643 % |
| || NET | 12.859 % |
-----------------------------------------------------------------------

May 29, 2020 17:00:46 Page 3 of 8


Cycle-Tempo 5.0 (Build 481) c:\users\ridho\documents\62797_orc-r245ca-pdrop05%-m03\versi akhir.gui

ENERGY BALANCE OF THE SYSTEM


============================

DEFINITION OF TOTAL ENERGY


Def. 1: Enthalpy minus enthalpy by environmental
conditions (water as LIQUID) plus HIGHER heating value
Def. 2: Enthalpy minus enthalpy by environmental
conditions (water as VAPOUR) plus LOWER heating value

POWER / HEAT TRANSMITTED FROM APPARATUS

NO APPARATUS TYPE BASED ON ENTHALPY BASED ON TOTAL ENERGY FLOWS [MW]


FLOWS [MW] DEFINITION 1 DEFINITION 2

6 Reheater 2 -73.299 -73.299 -73.299


2 Turbine 3 11.223 11.223 11.223
3 Condenser 4 0.000 0.000 0.000
5 Heat Exchgr. 6 0.000 0.000 0.000
9 Heat Exchgr. 6 0.000 0.000 0.000
4 Pump 8 -0.528 -0.528 -0.528
11 Pump 8 0.012 0.012 0.012
12 Pump 8 0.000 0.000 0.000
8 Sink/Source 10 62.593 62.593 62.593
1 Heat Exchgr. 12 0.000 0.000 0.000

8 PIPE 0.000 0.000 0.000


-------------- + -------------- + -------------- +
TOTAL TRANSMITTED : 0.000 0.000 0.000

APPLIED FLUIDS (TPSI, StanMix, RefProp 8)


=========================================

MEDIUM TYPE | APPLIED FLUID / COMPOSITION

RefProp 1 | R245fa
RefProp 2 | water

May 29, 2020 17:00:46 Page 4 of 8


Cycle-Tempo 5.0 (Build 481) c:\users\ridho\documents\62797_orc-r245ca-pdrop05%-m03\versi akhir.gui

DATA FOR ALL PIPES; SUBSEQUENTLY INLET AND OUTLET


=================================================

PIPE MEDIUM | MASS-FLOW MOLE-FLOW VOL-FLOW | PRESSURE TEMPERATURE ENTHALPY ENTROPY QUALITY MASSFR
NO TYPE | [kg/s] [kmol/s] [m3/s] | [bar] [°C] [kJ/kg] [kJ/kgK] [%-VAPOUR] [-]

1 RefProp 1 | 332.83 2.4829 2.7916 | 18.770 118.68 479.94 1.7888 96.56 1.0000
| 2.7916 | 18.770 118.68 479.94 1.7888 96.56 1.0000
2 RefProp 1 | 332.83 2.4829 30.277 | 2.0800 51.26 446.22 1.8074 100.00 1.0000
| 30.277 | 2.0800 51.26 446.22 1.8074 100.00 1.0000
3 RefProp 1 | 332.83 2.4829 28.623 | 2.0800 38.00 433.18 1.7663 100.00 1.0000
| 28.623 | 2.0800 38.00 433.18 1.7663 100.00 1.0000

4 RefProp 1 | 332.83 2.4829 0.25361 | 2.0800 34.48 245.11 1.1551 0.00 1.0000
| 0.25361 | 2.0800 34.48 245.11 1.1551 0.00 1.0000
5 RefProp 1 | 332.83 2.4829 0.25294 | 18.770 35.34 246.70 1.1561 0.00 1.0000
| 0.25294 | 18.770 35.34 246.70 1.1561 0.00 1.0000
6 RefProp 1 | 332.83 2.4829 0.28256 | 18.770 80.00 309.16 1.3450 0.00 1.0000
| 0.28256 | 18.770 80.00 309.16 1.3450 0.00 1.0000

7 RefProp 1 | 332.83 2.4829 0.25829 | 18.770 45.00 259.74 1.1977 0.00 1.0000
| 0.25829 | 18.770 45.00 259.74 1.1977 0.00 1.0000
8 RefProp 2 | 449.14 24.931 0.46218 | 18.770 81.28 341.82 1.0895 0.00 1.0000
| 0.46217 | 18.970 81.27 341.82 1.0894 0.00 1.0000
9 RefProp 2 | 449.14 24.931 0.46217 | 18.770 81.27 341.79 1.0894 0.00 1.0000
| 0.46217 | 18.770 81.27 341.79 1.0894 0.00 1.0000

10 WATERSTM | 1496.7 83.080 1.4994 | 1.0000 20.00 84.01 0.2965 0.00


| 1.4994 | 1.0000 20.00 84.01 0.2965 0.00
11 WATERSTM | 1496.7 83.080 1.4994 | 1.0000 20.00 84.01 0.2965 0.00
| 1.4994 | 1.0000 20.00 84.01 0.2965 0.00
12 WATERSTM | 1496.7 83.080 1.5032 | 1.0000 30.00 125.83 0.4368 0.00
| 1.5032 | 1.0000 30.00 125.83 0.4368 0.00

13 RefProp 2 | 449.14 24.931 0.47581 | 18.770 120.00 504.99 1.5264 0.00 1.0000
| 0.47581 | 18.770 120.00 504.99 1.5264 0.00 1.0000
14 RefProp 2 | 449.14 24.931 0.46489 | 18.770 90.00 378.44 1.1916 0.00 1.0000
| 0.46489 | 18.770 90.00 378.44 1.1916 0.00 1.0000

LOSSES IN PIPES
===============

PIPE TOTAL PRESSURE TEMPERATURE ENTHALPY ENTROPY


NO DROP DECREASE DECREASE INCREASE
[bar] [°C] [kJ/kg] [kJ/kg.K]

8 -0.20 0.00 0.00 -0.0001

-------- +

TOTAL LOSSES IN PIPES: 0.00 [kJ/s]

May 29, 2020 17:00:46 Page 5 of 8


Cycle-Tempo 5.0 (Build 481) c:\users\ridho\documents\62797_orc-r245ca-pdrop05%-m03\versi akhir.gui

ROTATING EQUIPMENT
==================

NO APPARATUS TYPE ISENTROPIC MECHANICAL EXHAUST


EFF. [%] EFF. [%] LOSSES [kJ/kg]

2 Turbine 3 85.00 input 90.00 input


4 Pump 8 80.00 input 100.00 fixed
11 Pump 8 80.00 input 100.00 fixed
12 Pump 8 80.00 input 100.00 fixed

MOTORS AND GENERATORS


=====================

NO APPARATUS TYPE MECHANICAL ELECTRICAL BOTH


EFF. [%] EFF. [%] [%]

1 GENERATOR 99.00 input


4 Pump 8 90.00 input 100.00 default 90.00 input
11 Pump 8 90.00 input 100.00 default 90.00 input
12 Pump 8 90.00 input 100.00 default 90.00 input

HEAT EXCHANGING EQUIPMENT


=========================

HEAT TRANSMITTED HIGH TERMINAL LOW TERMINAL FLOW-


NO APPARATUS TYPE IN APPARATUS TEMP DIFFERENCE TEMP DIFFERENCE DIRECTION
[kJ/s] [°C] [°C]

3 Condenser 4 62592.81 4.48 14.48 Counter


5 Heat Exchgr. 6 4339.61 6.26 2.66 Counter
9 Heat Exchgr. 6 16447.77 10.00 36.28 Counter
1 Heat Exchgr. 12 56840.16 1.32 10.00 Counter

May 29, 2020 17:00:46 Page 6 of 8


Cycle-Tempo 5.0 (Build 481) c:\users\ridho\documents\62797_orc-r245ca-pdrop05%-m03\versi akhir.gui

==========================================
= =
= APPARATUSES IN OFF-DESIGN MODE =
= =
==========================================

NO TURBINES, COMPRESSORS OR HEAT EXCHANGERS PRESENT IN OFF-DESIGN MODE


======================================================================

======================================
= =
= APPARATUSES IN DESIGN MODE =
= =
======================================

DESIGN DATA FOR TURBINES


========================

TURBINE NR. 2
===============

NUMBER OF CONNECTED PIPES = 2


INLET VOLUME-FLOW = 2.7916 m3/s

PIPE PRESSURE SPEC.VOLUME TURBINE MASSFLOW


NR [bar] [m3/kg] [kg/s]

2 2.0800 0.09097 332.8275 OUTLET


1 18.7700 0.00839 332.8275 INLET

DESIGN DATA FOR HEAT EXCHANGERS


===============================

NUMBER OF TERMINAL TEMP. DIFFERENCE FACTOR MASS FLOW


APPARATUS HIGH LOW U*A RATE

3 4.48 14.48 7338.95 1496.69


5 6.26 2.66 1031.76 332.827
9 10.00 36.28 806.604 332.827
1 1.32 10.00 13258.9 332.827

May 29, 2020 17:00:46 Page 7 of 8


Cycle-Tempo 5.0 (Build 481) c:\users\ridho\documents\62797_orc-r245ca-pdrop05%-m03\versi akhir.gui

May 29, 2020 17:00:46 Page 8 of 8