complies with necessary statutory
SD MR-1 Local Building Regulations
regulatory codes
SD MR-2 Soil Erosion Control Soil erosion control measures for pre-
construction and during construction
SD Cr-1 Natural Topography & Vegetation Retain Natural topography
Water Conservation
plumbing fixtures having flow rates 5 %
WC MR-1 Water Efficient Plumbing Fixtures
lower than the baseline flow rates
rainwater harvesting system to capture at
WC MR-2 Rainwater Harvesting least ‘one-day rainfall*’ run-off volume from
roof and non-roof areas
Energy Efficiency
Zero use of Hydro-chlorofluorocarbon
(HCFC) refrigerants in HVAC equipment and
EE MR-1 HCFC Free Equipment
Unitary Air-Conditioners. Use halon free fire
suppression equipment.
Building Envelope:Glazing
i. Equivalent Solar Heat Gain Coefficient
EE MR-2 Minimum Energy Performance (SHGCeqi)*: 0.5
ii. U value : 5.7 W/m2K
❖ Roof Assembly: U value : 1.5 W/m2K
❖ Wall Assembly: U value : 2.5 W/m2K
EE CR-3 On-site Renewable Energy – Common renewable energy systems for atleast 25%
Lighting of annual common area lighting
Low VOC Materials, Paints & Eco-label certified paints, coatings (including
RHW Cr-5 primers) for the interior walls and ceilings /
Adhesives
Eco-label certified adhesives and sealants
Required Unknown
4 0
2 0
2 0
4 0
2 1
1 0
1 0
20 3
ter Conservation
Required Achieved
Required Satisfied
3 0
2 0
1 0
4 4
23 4
nergy Efficiency
Required Satisfied
Required Satisfied
7 0
2 1
1 0
1 0
3 0
4 0
1 0
2 0
20 1
1 0
1 0
5 0
2 1
2 0
2 0
2 0
3 0
18 1
Required
Required
Required
2 2
4 3
2 0
2 1
2 0
14 6
2 0
2 0
1 0
5 0
openable
window
Spaces length width carpet area window area
area(slidi
ng)
cross
Spaces Area % of area ventilated
area %
Living 15.51 46.367713 46%
Bedroom-1 7.29 21.793722 21%
Bedroom-2 7.29 21.793722 0%
Kitchen 3.36 10.044843 10%
33.45 77% >75 3 points
Total
watts/floor
Watts Floor area area
Living 38 15.51
22
Bedroom-1 38 7.29
5
Bedroom-2 38 7.29
Kitchen 22 3.36
Toilet 9 2.4
Balcony 28 5.76
200 41.61 4.8065369 < 5 W/sq.m
Glazing
Glazing
factor to
Wn-Area VLT factor
be
achieved
achieved
2.025 50% 1.30560928 1
1.62 35% 1.55555556 1
1.62 35% 1.55555556 1
0.99 35% 2.0625 2
compliance 100% >95% 2 points
% of % of
openable openable
openable area to area to
D- height D-width
door area carpet carpet
area area
required achieved