Fullmarks 30
QNo1)
a) Give an outline to describe different types of effluent streams in a large size industrial
factory.
b) What is the necessity of conducting Industrial waste survey? How it can be
accomplished? Give suitable example. 6
Q No2. )
A food processing industry generates discharges contaminated effluent with fluctuation of flow
depending on schedule of production and demands of products.
The total flow is 0.16 m3/sec.Sampling was done for 15 consecutive days for every 3 hrs
intervals. The average BOD is 485 mg/l and maximum reaches at 760 mg/l.The effluent BOD
from equalization basin is limited to 600mg/l.Graphical analysis indicates 16% reaches
285mg/land 84% probability a value of 710 mg/l
Determine dimension of an equalization unit to meet the desired effluent standard with 95%
probability that the equalized effluent will be equal to or less than 600mg/l.Assume Z=1.65.Depth
of the tank 2.60 m.check HRT.
7
Q No 3)
a)What is a floatation tank ? How it is different from a oil skimming tank? What is API
separator? Give some design criterion on API separator. 4
b) It is decided to adopt 25kg/d-m2 solids loading rate for design of a DAF unit to concentrate
0.33% solid from a paper mill white liquor tank to about 5% solid. Determine the size of the tank
and pressure in kpa for recycled flow with following information,
Solids flow rate 400 m3/day
A/ S ratio 0.02 ml/mg
Saturation fraction 0.65
SLR 10 L/M2/MIN
Recycled flow 500 m3/day
Air solubility 0.0190 l of air/Lof liquid.