You are on page 1of 7

SANRAY LABORATORIES PVT LTD.

Plot No: 48,Sy.No: 302/3,


EC Extension, ECIL X Roads,
Kushaiguda, Hyderabad – 500062,
Telangana

Report No:STL/20070300772

SUBMITTED
TO

BY

SANRAY LABORATORIES PVT LTD


Hyderabad

july,2020

i
SANRAY LABORATORIES PVT LTD.
Plot No: 48,Sy.No: 302/3,
EC Extension, ECIL X Roads,
Kushaiguda, Hyderabad – 500062, Report No:STL/20070300772
Telangana

Table of Contents
Sl. No Title Page No
1 Introduction
2 Sample details
3 Analysis details of each sample
4 Results
SEM analysis
Analysis:II (Raw Material SEM Images)
Analysis:III (Raw Material EDAX)
Analysis:IV (Heat Treatment SEM images)
Analysis:V (Heat Treatment EDAX)
Analysis:VI (Failed Chisel SEM IMAGES)
Analysis:VII (Failed Chisel EDAX)
5 Conclusion
6 Reference

2|Page
SANRAY LABORATORIES PVT LTD.
Plot No: 48,Sy.No: 302/3,
EC Extension, ECIL X Roads,
Kushaiguda, Hyderabad – 500062, Report No:STL/20070300772
Telangana

1. Introduction:

2. Sample Details:
The powder sample collected on the Solar pannels are investigated By Using SEM &
EDAX analysis
The corrosion studies on Solar pannels and Aluminium alloys by using Salt Spray As per
ASTM B117

3. Analysis details of each sample:


I) The Powder Morphology and Powder compoistion of the Dust Particels which are collected on the solar pannel can
be analyzed By using SEM with EDAX.
II) The Corrosion Studies of Solar Pannel and aluminum alloys whether the alloys and solar pannels were corroded or / Not
can be studies by Using Salt spray

3|Page
SANRAY LABORATORIES PVT LTD.
Plot No: 48,Sy.No: 302/3,
EC Extension, ECIL X Roads,
Kushaiguda, Hyderabad – 500062, Report No:STL/20070300772
Telangana

4. Results:
i) Chemical composition:

Chemical Composition in % By mass as per ASM Vol 9

ii. SEM analysis:

S.NoTest Test Method Results


Parameters
Mechanical Testing

Metallography Test

1 ASM Vol 9

2 ASM Vol 9

3 ASM Vol 9

4|Page
SANRAY LABORATORIES PVT LTD.
Plot No: 48,Sy.No: 302/3,
EC Extension, ECIL X Roads,
Kushaiguda, Hyderabad – 500062, Report No:STL/20070300772
Telangana

SEM Images And EDAX analysis

5|Page
SANRAY LABORATORIES PVT LTD.
Plot No: 48,Sy.No: 302/3,
EC Extension, ECIL X Roads,
Kushaiguda, Hyderabad – 500062, Report No:STL/20070300772
Telangana

ii) Salt Spray Analysis

S.
Sample Description Test Parameter Test Method Results
No.

I.Mechanical Testing
1.Salt Spray Test

There is no pits or rust formation


CONNECTORS-
1. Salt Spray Test (48 Hrs) ASTM B117-18 observed after exposure to salt spray
INV019/02-01-2020
(fog) for 48 hrs
There is no pits or rust formation
YOKE PLATED-IMI
2. Salt Spray Test (48 Hrs) ASTM B117-18 observed after exposure to salt spray
67855/29-10-19
(fog) for 48 hrs
Rust formation observed on rivets part
ARMATURE PLATED-
3. Salt Spray Test (48 Hrs) ASTM B117-18 after exposure to salt spray (fog) for
IMI 67855/29-10-19
48 hrs
There is no pits or rust formation
CORE PLATED- IMI
4. Salt Spray Test (48 Hrs) ASTM B117-18 observed after exposure to salt spray
67604/30-09-19
(fog) for 48 hrs
Observation: Image(Photo) is attached with test Report
Note: Before testing specimens to be cleaned with soft cloth.
After testing specimens to be washed with running water dried with soft cloth.
1.Salt Solution type: 5% Nacl,
2. Chamber Temperature 35 00C,
3.Saturation Temperature: 45 C,
4.Concentration/specificgravity: 1.030486 @270C,
5.Test Time: 48 Hrs,
6.Position of specimen
0
200 from the Verticle.
7. pH 6.9@35 C
8. Date of Test Start on: 29.01.2020, Time: 6:00 PM
9. Date of Test Completion on: 31.01.2020, Time: 6:00 PM
10 Flow rate at Fog collection 1: 27mL/hr/80cm22 @ every 16Hrs
11. Flow rate at Fog collection 2: 25mL/hr/80cm @ every 16Hrs

6|Page
SANRAY LABORATORIES PVT LTD.
Plot No: 48,Sy.No: 302/3,
EC Extension, ECIL X Roads,
Kushaiguda, Hyderabad – 500062, Report No:STL/20070300772
Telangana

Corrosion Test Procedures

7|Page