NOTE:

SCHEDULE OF COLUMN
COL. 1. THE STRUCTURAL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH
SECTION MAIN REINF. LATERAL TIES APPROVED WORKING DRAWING
SIZE 25 STANDARD NUT WITH
LOCK NUT/ WASHERS 2. STRESSES ADOPTED FOR STRUCTURAL DESIGN ARE :-
200

BASE PLATE A. fck = 25 N/mm² FOR CONCRETE GRADE M25


356
800 X 800

16 nos. B. fy = 500 N/mm² TMT BAR, CONFORMING TO IS-1786.


750

THREADED LENGTH
20 mm dia. M25 FDN. BOLTS, 12 NOS. 3. CLEAR COVER TO REINFORCEMENT SHALL BE AS FOLLOWS:-
16 nos. 700 (750MM LONG A. FOOTING [BOTTOM] = 50 mm.
4D

10 mm dia. R= 3D
B. COLUMN = 40 mm.
J - BOLTS
#8@175mm C/C 4. FOR BENDING, BINDING, CRANKING AND ANCHORAGE OF
REINFORCEMENT SHOULD BE AS PER IS 456-2000.
Y 5. PROVIDE SEPERATOR BARS, M. S. CHAIR WHEREEVER NECESSARY, TO
KEEP ADEQUATE COVER TO REINFORCEMENT.
6. DEVELOPMENT LENGTH OF REINFORCEMENT SHOULD BE AS PER IS
456[SP-16].
50MM DIA CORRUGATED PIPE 1500 7. ALL DIMENSIONS ARE IN mm. EXCEPT WHERE OTHERWISE STATED.
FOR CABLE ENTRY 8. P.C.C WORK IN SUBSTRUCTURE IS TO BE DONE WITH M15 GRADE OF
CONCRETE.
450

BASE PLATE 20mm


THICK 9. S.B.C OF SOIL = 04 T/Sqm. (AS PER GEOTECHNICAL INVESTIGATION
REPORT)
4800 10. THICKNESS OF BASE PLATE: 20 mm.
GROUND
11. LOADS CONSIDERED ARE BASED ON THEIR CORRESPONDING I.S.
LEVEL
2400

STANDARDS.

750
12. WELL COMPACTED JHAMA BRICK AGGREGATE LAYER OF 300 mm
8Ø @175C/C
X X'
BELOW FOUNDATION SHOULD BE PRESENT.
1350

10Ø @150C/C
13. SEISMIC LOADS ARE CONSIDERED BASED ON IS 1893
14. THIS DRAWING IS INTENDED FOR AS GOOD FOR CONSTRUCTION.
2000

BOTHWAYS
960 960 960 960 960
DRAWING FOR APPROVAL
250

P.C.C M15
CLIENT:
300

JHAMA BRICK LAYER


100

Y'
1500
PLAN VIEW REPRESENTING ORIENTATION OF SUPERSTRUCTURE
SECTION ALONG Y-Y'
Y AGARTALA SMART CITY LIMITED
CONTRACTOR:
HONEYWELL AUTOMATION INDIA LIMITED
1500 EARTH STRIP
(COPPER) 25X3MM ECO MAROL BUILDING, MAROL MAROSHI ROAD
50MM DIA CORRUGATED PIPE MAROL, ANDHERI (E), MUMBAI 400059
BASE PLATE
FOR CABLE ENTRY
700mm x 700mm x
20mm THICK 17.2MM COPPER
BASE PLATE 20mm STRIP SIGNATURE OF ENGINEER:

450
800 00 THICK
Ø4
GROUND

2000
2400

800

X X' LEVEL
FOUNDATION J FOUNDATION J
BOLT OF 25MM DIA BOLT OF 25MM DIA
750 LENGTH TO BE 750 LENGTH TO BE
PROVIDED ON PROVIDED ON
EACH GROVE EACH GROVE 10Ø @150C/C
800 BOTHWAYS EARTHING
NAME OF WORK: IMPLEMENTATION OF
INTEGRATED COMMAND & CONTROL CENTER &
SMART ELEMENTS IN AGARTALA CITY.
P.C.C M15
JHAMA BRICK LAYER
Y' DRAWING TITLE: REINFORCEMENT DESIGN OF
PLAN OF FOOTING COLUMN AND FOOTING CARRYING POLE MOUNTING
SECTION ALONG X-X' STRUCTURE FOR VMD OF SIZE 5m x 3m at 6m HEIGHT.