You are on page 1of 2

Job Number Sheet

5\1
Job Title
Re Evaluation of Wall Plate
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
Calcs by Checked by Date
E-Mail : mail@prokon.com 2020/10/23

CALCULATION OF WIND LOAD


As per "Design of Buildings for Higher Wind- Sri Lanka, 1980" Anuradhapura is located in Zone 3.
The Building is to be designed as a Post Disaster Structure considering its archiological value.

Basic Wind Speed, V;

Design of Buildings for High Winds:Table 3.1

V = 38 m/s

Design Wind Speed, Vs;

With in a 1Km radious from the site, topography is having some barriears. Hence,

CP3:Chapter V-2:Cl5.4

S1 = 1.1

The Building is located in a fully open land with scattered obstructions.

Length of the Building is almost 50m

CP3:Chapter V-2:Cl5.5\T3

S2 = 0.7

CP3:Chapter V-2:Cl5.6\Annexure C

S3 = 1.1

CP3:Chapter V-2:Cl5

Vs = S1. S2. S3. V


= 1.100 ×0.7000 ×1.100 ×38.000
= 32.186

Hence, Design wind Speed will be taken as 33ms-1.

For SI unites, factor "k" is given in the code.

k = 0.613

CP3:Chapter V-2:Cl6

q = k . Vs 2
= 0.6130 ×33 2
= 667.557

Hence, Dynamic Pressure will be considered as 0.7KNm-2.


Job Number Sheet
5\2
Job Title
Re Evaluation of Wall Plate
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
Calcs by Checked by Date
E-Mail : mail@prokon.com 2020/10/23

Consider wind applied on Roof;


CP3:Chapter V-2:Cl7.2\T8

Roof Angle, '

 = 60

Height/Width, ,

h
=
w
6.5
=
26
= 0.2500

 from table 8.

Cpe = - 0.7

With the arrangement of the Building,

It can be considered with two oppasit equally permiable faces & other faces impermiable

CP3:Chapter V-2:Appendix E

Cpi1 = 0.2

Cpi2 = - 0.3

F1 = (Cpe - Cpi1). q
= (-0.7000 - 0.2000 )×1.36
= -1.2240

F2 = (Cpe - Cpi2). q
= (-0.7000 - -0.3000 )×1.36
= -0.5440

Hence, there is a Maximum upword wind force of 1.25KN/m2 & Minimum of 0.55N/m2.

LOAD COMBINATIONS

Following load combinations considered for the analysis of the structure.

Combination 01 => All spans fully loaded.


1.4Gk + 1.6Qk

Combination 02 => Possitive Wind Load


1.2Gk + 1.2Qk + 1.2Wk

Combination 03 => Negative Wind Load


0.9Gk + 1.4Wk

You might also like