You are on page 1of 12

6/13/2016 TLanal Program

TLanal, TolAnal
 

TLanal : TL Glow Curve Deconvolution Program

TolAnal : TL/OSL Glow Curve Deconvolution Program (2009/07/07)

beta  TolAnal : TL/OSL Glow Curve Deconvolution Program ­ Including Interaction Model (2011/06/30)

 
TLanal 

download TLanal program [ver 1.0.0] (2004/05/31)

Operation System : Windows 2000 or Windows XP with Microsoft .net framwork 1.0

download TLanal program [ver 1.0.2] (2008/04/20)

Operation System : Windows 2000, Windows XP or Windows Vista with Microsoft .net framwork 2.0

download TLanal program [ver 1.0.3] (2008/09/17) 
Include MOK(mixed order kinetics) and GA+(general approximation plus)

Operation System : Windows 2000, Windows XP or Windows Vista with Microsoft .net framwork 3.5

Install Procedure

 1  Extract
([ver 1.0.0] files contained :  SetUp.Exe, SetUp.Ini, TLAnal Installer.msi, InstMsiA.Exe,  InstMsiW.Exe)

([ver 1.0.2] files contained :  SetUp.Exe, TLAnal Installer.msi)

([ver 1.0.3] files contained :  SetUp.Exe, TLAnal Installer.msi)
http://physica.gsnu.ac.kr/TLanal/ 1/12
6/13/2016 TLanal Program

 2  Run SetUp.Exe
 

Sample Data (TLD­100, 100mGy)

(press right button of mouse on 'download' and save)

1. TL glow data (text format) : download  

2. TL glow data (tld format) : download

3. TL material data (tlm format) : download

4. TL project data1 (tlp format) : download   ­­ deconvoluted by General Approximation with 5 peak

5. TL project data2 (tlp format) : download   ­­ deconvoluted by First Order Kinetics with 6 peak

Tiny Manual

This program can be used for one kind of TL
material, for one kind of TL reader, for various
exposure by radiation, and for various heating
profile.

step 1 Introducing Glow Data

Text File Format (*.txt or *.dat)

type 1 (heating ratio will be asked with dialog)
temperature(in Kelvin)   intensity
300.0  0.0
302.0  5.7
304.2  8.6
306.2  10,3
...
type 2
heating ratio
temperature(in Kelvin)    intensity
10.0
http://physica.gsnu.ac.kr/TLanal/ 2/12
6/13/2016 TLanal Program

300.0  0.0
302.0  5.7
304.2  8.6
306.2  10,3
...  

type 3 (can be used in arbitrary temperature profile)
time(in sec)   temperature(in Kelvin)   intensity
0.0     300.0      0.0
0.2     302.0      5.7
0.4     304.2      8.6
0.6     306.2      10,3
...

step 1­1 Add Glow Data

File menu ­ Add Glow Data... ­ choose TL Glow Data Files (*.txt; *.dat) ­ Select data file introducing.

When data is linear heating profile and do not containe heating ratio at first line, dialog will appear as follows.
http://physica.gsnu.ac.kr/TLanal/ 3/12
6/13/2016 TLanal Program

(You shoud respond the edit box appeared as red.)
 

 
In above dialog, if "Use Fixed Temperature Range" check box is checked, 
the range of temperature to analyze is restricted within "From" ~ "To".  
It is efficient when more than one raw data set is used.  

step 2 Introducing The Model

When the glow data have been introduced, main windows appear as follows.

http://physica.gsnu.ac.kr/TLanal/ 4/12
6/13/2016 TLanal Program

Left Pane : Graph of measured Data (If "List TL Data" is checked in View menu, leftmost pane is sheet of raw data)

Right Pane : The TL model (Material, Exposure, Instrument)
    Material : Traps information
    Exposure : n0 value of each trap
    Instrument : Noise(Background), Acceptance(magnification factor ­ fixed in this version), Back Radiation(Blackbody radiation)

http://physica.gsnu.ac.kr/TLanal/ 5/12
6/13/2016 TLanal Program

step 2­1 Press "Add Trap" in the right­top part of right pane (Introducing one trap)

step 2­2 

http://physica.gsnu.ac.kr/TLanal/ 6/12
6/13/2016 TLanal Program

When "Add Trap" dialog appear, choose trap mode (in the above sample dailog, "Mixed Order Kinetics" is selected)
Adjust parameter sliders to fit one peak of raw data which is indicated by cross.
(Peak height is adjusted by n0 and position is adjusted by E and s, and so on)

http://physica.gsnu.ac.kr/TLanal/ 7/12
6/13/2016 TLanal Program

Repeat above step by "Add Trap" for other peaks as follows.

If all traps have been tntroduced, the main form is as follows.

http://physica.gsnu.ac.kr/TLanal/ 8/12
6/13/2016 TLanal Program

step 3 Deconvolution

http://physica.gsnu.ac.kr/TLanal/ 9/12
6/13/2016 TLanal Program

Analysis menu ­ Deconvolution...
"Deconvolution Status" dialog box will be appeared as follows.

step 3­1 Press "Iterate" button in the middle­bottom part of the form.

When satisfied result is acquired, press "OK" button to keep the traps information.
Then the traps parameters will display in the right pane.
http://physica.gsnu.ac.kr/TLanal/ 10/12
6/13/2016 TLanal Program

Final shot (TLD­100, fitted by MOK for five peaks)

Reference
http://physica.gsnu.ac.kr/TLanal/ 11/12
6/13/2016 TLanal Program

1. "A computer program for the deconvolution of thermoluminescence glow curves", Radiation Protection Dosimetry 115, 1­4, pp. 345­349 (2005).[2005/12/20]
2. "A new method for the numerical analysis of thermoluminescence glow curve", Radiation Measurements, 42, pp. 731­734 (2007) [2007/April­May]
3. "A new computer program for thermoluminescence glow curve deconvolution by the general approximation", LED2008, presentation [2008/09/21]

http://physica.gsnu.ac.kr/TLanal/ 12/12