7150
Laboratories
Contract: C/22143
Holbrook House, Little Waldingfield,
Sudbury, Suffolk CO10 0TH Page: 1 of 1
Tel: (01787) 247595 Fax: 01787 248420
e-mail: srl@srltsl.com Date: 15 March 2012
Client: Armstrong
Test Date: 14/03/2012
Empty Room: Temperature: 17.2 °C Humidity: 57 %RH Pressure: 1028 mbar
Room with Sample: Temperature: 16.9 °C Humidity: 45 %RH Pressure: 1028 mbar
Sample Description: Dune Supreme 600x600x15mm
Test 8
Absorp Practical
Freq T1 T2 Coeff Absorp
Hz sec sec Coeff #
50* 5.07 4.06 0.18
Sound Absorption Coefficient
63* 4.84 3.82 0.21 n/a
80* 5.31 4.82 0.07 1.2
100 7.65 4.94 0.27
1.1
125 7.53 3.95 0.45 0.40
160 6.56 3.54 0.49 1
*
10000* 0.93 0.71 0.44
0.60
Class C
Calculated to EN ISO 11654:1997
NRC 0.55
Calculated to ASTM C 423-01
* Denotes frequencies outside the range covered
by BS EN ISO 354:2003
T1, empty room reverberation time
T2, room reverberation time with sample
# Practical absorption coefficient, BS EN ISO 11654:1997 v4.2