ROUTINE TEST REPORT

Size of Cable : 3×10 Testing Date : 27/10/2020

Type of Cable : NYFGbY-FRLS Batch No : EM-120, 25.10.2020

Voltage Grade : 600/1000 V Color : Black

Ref. Standard : IEC 60502-1 & VDE 0271/3.69 Length : 288 Meter

Sl. Description of Test Unit Standard Obtained Remarks


No.

01 No. & Diameter of wire no/mm 7/1.35 7/1.35 (avg.) Satisfactory

02 Thickness of insulation mm Nom.- 1.0 Nom.: 1.05,1.02,1.03 Satisfactory


Min.- 0.82 Min.: 0.98, 0.97, 0.99

03 Thickness of inner sheath/inner mm 1.0 (Approx.) 1.23 Satisfactory


covering

04 Thickness of sheath mm Nom.- 1.8 2.2 Satisfactory


Min.- 1.32 1.9

05 Overall diameter of sheathed cable mm 21.30 23.80 Satisfactory


(Approx.)

06 D.C. Resistance of conductor at 200C W/km Max.- 1.83 1.72 Satisfactory

07 Insulation resistance constant ki at MW.km Min.- 36.7 R-139, Y-282, B- Satisfactory


200C 238
08 High voltage test for 5 minutes kV 3.5 Withstood Satisfactory
(Withstand)

TESTED BY AUTHORISED SIGNATURE